SPECIFICATIONS OPERATION

Voltage: 6 VDC 1.) Invisible light rays are continually emitted from the faucet
(4 “AA” Alkaline) sensor.
Sensor Range: 7.5" Approximate 2.) When the user’s hands come into range of the sensor’s detection
Operating Water zone (8" approximate), the beam is reflected back to the
Pressure: 20-80 psi sensor’s receiver and converted to a low voltage electrical
signal activating a solenoid valve.
Ambient
Temperature: 32°F to 122°F (0°C to 50°C) 3.) After the user removes their hands, the absence of reflected
Operational Water light stops the low voltage electrical signal, closing the valve.
Temperature: 35°F to 140°F (2°C to 60°C) The circuit automatically resets for the next user.
Aerator: 2.0 GPM Vandal-Resistant (Standard) 4.) If an object is in view continuously for thirty seconds, the
faucet will automatically shut off. The faucet will remain off
CARE AND CLEANING INSTRUCTIONS until the object is removed. After the object is removed, the
DO NOT use abrasive or chemical cleaners to clean faucets as they faucet functions normally.
will dull the luster and attack the chrome or special decorative
finishes. Use only mild soap and water, then wipe dry with a clean
cloth or towel. While cleaning the bathroom tile and floor, the faucet
Battery-Powered Faucets

and electronics should be protected from splattering of water, cleaner,


AquaSense ‘A’

acids, and cleaning fluids that can damage the sensor faucet.

TROUBLESHOOTING GUIDE
PROBLEM POSSIBLE CAUSE TO DIAGNOSE REMEDY
FAUCET WILL NOT Water supply not turned on. Check supply stops. Turn on water.
FLOW WATER
Batteries not connected. Check connections. Reconnect batteries.

Cable connection is not Check cable connection. Remove battery, and disengage the cable
fully engaged. connection. Check cable connection for broken
pins and reconnect cable. Check battery for
voltage level and reinstall.

Low battery. Flashing red light in sensor eye Remove batteries and replace with
indicates low battery. four (4) new alkaline batteries.

Solenoid valve inoperative. Move hand in front of faucet to If clicking, open solenoid valve
see if solenoid valve is clicking. and clean it.

If not clicking, replace solenoid valve.

Sensor/electronics are Move hand in front of faucet to Remove the battery and short circuit the
inoperative. see if solenoid valve is clicking. battery terminals with Allen wrench. This will
See note in Step 4. reset the electronics. Replace battery.

Filter is plugged. Shut off water supply. Remove Clean the filter and reassemble.
clean out cap.

FAUCET CONTINUES Solenoid valve is dirty. Open the solenoid valve and check for Shut off water supply. Disassemble solenoid
TO RUN FOR MORE debris. Carefully observe the way and remove debris from diaphragm and/or
THAN 30 SECONDS valve goes together for reassembly. plunger tip. Reassemble solenoid.
OR DRIPS

ZURN INDUSTRIES, INC. COMMERCIAL BRASS OPERATION, 5900 ELWIN BUCHANAN DRIVE, SANFORD, NC, U.S.A. 27330
PHONE: 1-800-997-3876 FAX: 919/775-3541 WEBSITE: www.zurn.com
ZURN INDUSTRIES LIMITED 3544 NASHUA DRIVE, MISSISSAUGA, ONTARIO L4V 1L2 PHONE: 905/405-8272 FAX: 905/405-1292

© 2003 Zurn Industries, Inc. Printed in the U.S.A. Form No. FV254, 1/03

You might also like