SCADALink RIO900

I/O Telemetry Controller / Integrated Radio RTU


FEATURES
• 915-928 MHz.
• LOS Range >20 miles
• RS232/RS485 interface
• Modbus RTU Slave Addressable
• Interoperates with I/O Expansion Modules
(AI4 / AO4 / DI8 / DO8 / A8D4 / COMBO-I/O)
• DIN Rail mount Package
• Class I Div 2 Certified for Hazardous locations

OVERVIEW APPLICATIONS
The SCADALink RIO900 is a license-free 915-928 MHz radio / RTU designed for • High Tank Level Shutdown
general serial communications to smart devices such as Electronic Flow Meters • Water Tank Level Control
(EFM) and Industrial I/O signals such as 4-20mA signals and Dry Contact Digital • Pipeline Inlet Shutdown
I/O. The
RIO900 provides wireless RTU and I/O capabilities, failsafe mode and scheduled or
Sleep Mode for low power operation.
SYSTEM DIAGRAM

The RIO900 features license-free 915-928 MHz radio technology providing a range of up to 20 miles.
The longer range can be achieved with RIO900 nodes configured as Repeaters.

#315 - 3750 46th Ave. S.E. Calgary, Alberta Canada. T2B 0L1
Ph: (403) 243-5135 Fax: (403) 243-5165
www.scadalink.com
rev 1.1
SPECIFICATIONS

Radio Communications Power Consumption*


Band Peak Tx Current(@24VDC) 105mA
915-928 MHz (Intl version) Rx Current (@24VDC) 6mA
Tx Power 1 mW – 1 Watt Operating Mode Scheduled or Periodic Sleep for Low Power
Rx Sensitivity -110 dBm (@9600 bps) Operation
RF Data Rate 9.6 or 115.2 Kbps (* – Does not include power consumption of I/O modules)
Range (LOS) >20 miles DIMENSIONS L: 9mm x W: 23mm W x H: 116mm
Antenna Connector MCX
Environmental
Interface Operating Temperature -40 to 85 Deg. C
Input / Outputs 1 RS232, 1 RS232 / RS485
Serial 1200 – 115,200 Baud Certification
Electrical Regulatory FCC, IC , ETSI
Input Voltage +10 to 30VDC Hazardous Location Class 1 Div 2, Group C, D T3C
Suitable for use in: Class 1 Zone 2, IIB, T3

I/O TELEMETRY

RS232 & RS485 Interface

RS485 Multidrop RS485 and RS232

Point to Point I/O Telemetry Virtual I/O Mode

MODULAR I/O EXPANSION ORDERING INFORMATION

I/O Expansion bus allows interfacing up to 10 SCADALink I/O Modules. Part Number: SCADALINK-RIO900
AI4: 4 Analog Inputs (4-20mA)
AO4: 4 Analog Outputs (4-20mA) INCLUIDING:
DI8: 8 Digital Inputs
DO8: 8 Digital Outputs (Relay)
A8D4: 4 Analog/ Digital Inputs,
4 Analog/ Digital/
Pulse Inputs /
4 Digital Outputs
COMBO I/O

#315 - 3750 46th Ave. S.E. Calgary, Alberta Canada. T2B 0L1
Ph: (403) 243-5135 Fax: (403) 243-5165
www.scadalink.com