DATA HANDBOOK Engine data

Power generation engines 13-series

Technical data

DC13 072A, 438-487 kW / 503-553 kVA (engine ref. 02-14)

Emission compliance Fuel injection system


Fuel optimized, non-compliant Unit injectors, PDE

1500 rpm (50 Hz) 1800 rpm (60 Hz)


Unit
PRP ESP PRP ESP
Gross power 438 480 445 487 kW
503 553 503 553 kVA
Gross torque 2788 3056 2361 2584
Spec. fuel consumption
full load 192 196 195 199 g/kWh
3/4 load 183 183 187 188 g/kWh
1/2 load 184 183 190 187 g/kWh
Heat rejection
to coolant 134 158 142 166 kW
to exhaust gas 309 344 320 358 kW
to charge air 89 104 96 112 kW
to surrounding air 35 39 36 41 kW
Air consumption 32 34 35 36 kg/min
Air temperature
before charge air cooler 211 227 213 231 °C
after charge air cooler 50 50 50 50 °C
Pressure in intake manifold 2.4 2.6 2.1 2.2 Bar
Fall of pressure, charge air cooler 0.10 0.10 0.15 0.15 Bar
Exhaust flow 34 36 36 38 kg/min
Exhaust temperature 536 563 521 557 °C
Step load performance
(According to class G2. 57 52 72 66 %
See section 2 for more information.)
257 257 328 328 kW

Cooling performance
Cooling package 1.3 m2, fan Ø914, ratio 1:0.9

1500 rpm (50 Hz) 1800 rpm (60 Hz)


PRP ESP PRP ESP
Air-on Airflow Rest- Air-on Airflow Rest- Air-on Airflow Rest- Air-on Airflow Rest-
temp* riction temp* riction temp* riction temp* riction
(°C) (kg/s) (Pa) (°C) (kg/s) (Pa) (°C) (kg/s) (Pa) (°C) (kg/s) (Pa)
N/A N/A 500 N/A N/A 500 55 5.5 500 49 5.5 500
52 6 300 47 6 300 60 8.5 400 56 8.5 400
60 8.5 200 55 8.5 200 66 11 300 64 11 300
64 11.5 150 59 11.5 150 68 14 220 66 14 220
*Based on engine coolant temperature 105°C
Fan power losses (kW)
10 17