C400D6 Nueva
C400D6 Nueva
C400D6 Nueva
Model: C400D6
Frequency: 60 Hz
Fuel type: Diesel
Standby Prime
Engine rating rating
Engine manufacturer Cummins
Engine model QSG12-G4
Configuration Cast iron, 6 cylinder
Aspiration Turbocharged and after cooled
Gross engine power output, kWm 466 424
BMEP at set rated load, kPa 2634 2393
Bore, mm 132
Stroke, mm 144
Rated speed, rpm 1800
Piston speed, m/s 8.64
Compression ratio 17:1
Lube oil capacity, L 34.1
Overspeed limit, rpm 2070
Regenerative power, kW 56
Governor type Electronic
Starting voltage 24V Volts DC
Fuel flow
Maximum fuel flow, L/hr 182
Maximum fuel inlet restriction, mm Hg (clean filter) 152.4
Maximum fuel inlet temperature, °C 71
Standby Prime
Air rating rating
Combustion air, L/sec 518 500
Maximum air cleaner restriction, kPa 6.2(Dirty HD AC)
Exhaust
Exhaust gas flow at set rated load, L/sec 1274 1160
Exhaust gas temperature, °C 533 485
Maximum exhaust back pressure, kPa 10.2
power.cummins.com
©2018 Cummins Power Generation Inc. D-6339-EN (2018)
Standard set-mounted radiator cooling
Ambient design, °C 50
Fan load, kWm 19
Coolant capacity (with radiator), L 34
Cooling system air flow, m3/sec @ 12.7 mmH2O 8.4
Total heat rejection, kW 246 121
Maximum cooling air flow static restriction kPa 0.249
* Weights represent a set with standard features. See outline drawing for weights of other configurations.
Genset outline
Open set
Enclosed set
Outlines are for illustrative purposes only. Please refer to the genset outline drawing for an exact representation of this model.
Alternator data
Connection Temp rise ºC Duty Alternator Voltage
Wye, 3-phase 150/125/105 C S/P S4G 208-240V & 416-480V
power.cummins.com
©2018 Cummins Power Generation Inc. D-6339-EN (2018)
Ratings definitions
Emergency standby Limited-time running Base load (continuous)
Prime power (PRP):
power (ESP): power (LTP): power (COP):
Applicable for supplying power Applicable for supplying power Applicable for supplying power Applicable for supplying power
to varying electrical load for to a constant electrical load for to varying electrical load for continuously to a constant
the duration of power limited hours. Limited Time unlimited hours. Prime Power electrical load for unlimited
interruption of a reliable utility Running Power (LTP) is in (PRP) is in accordance with hours. Continuous Power
source. Emergency Standby accordance with ISO 8528. ISO 8528. Ten percent (COP) is in accordance with
Power (ESP) is in accordance overload capability is available ISO 8528, ISO 3046,
with ISO 8528. Fuel Stop in accordance with ISO 3046, AS 2789, DIN 6271 and
power in accordance with ISO AS 2789, DIN 6271 and BS 5514.
3046, AS 2789, DIN 6271 and BS 5514.
BS 5514.