Aps12 320
Aps12 320
Aps12 320
Output
DC Output 21.5V – 32V / 43-57.5V In the interests of continual product improvement all specifications are
Voltage Range subject to change without notice.
DC Output APS3-300 48V: 6.00kW
Power 24V: 4.32kW
(maximum)* APS6-300 48V: 8.90kW
APS6-500 48V: 12.0kW
24V: 8.64kW
* Ratings are stated without LVD’s fitted. In some
cases lower ratings may result when LVDs are
used. Refer to installation guide for detailed load
specs and MCB derating factors.
Environmental
Operating -40°C to +70°C [-40°F to +158°F]
Temperature
Range* * Refer to rectifier data sheet for more information.
Output current is derated above 50°C [122°F] and
below -10°C [14°F]
Mechanical
Dimensions APS3-300: 3U, 19” mounting, 315mm [12.4”]*
H,W,D APS6-300: 6U, 19” mounting, 335mm [13.2”]*
APS6-500: 6U, 19” mounting, 335mm [13.2”]*
System
System SC200 or SC100
Controller
DC Distribution APS3-300: 12-way circuit breakers
Module (2 x battery, 10 x load)
APS6-300: 20-way circuit breakers
(4 x battery, 16 x load)
APS6-500: 20-way circuit breakers
(4 x battery, 16 x load)
Communication USB direct*
Features 10BaseT Ethernet*, TCP/IP*, SNMP*, Modbus-
TCP*, Modbus-RTU* and on board web server*
RS232 to external PSTN or GSM modem (modem
not included)
*SC200 only
Low Voltage APS3-300: optional battery LVD
Disconnect APS6-300: optional 200A LVD’s for battery
(LVD) or load, or both.
APS6-500: optional 400A LVD’s for battery
or load, or both.
Rectifier Blank For unused rectifier positions
Panels
Options External Surge Protection
Environmental
Temperature Rated: -10°C – +50°C [14°F – +122°F]
Range* Extended: -40°C – +65°C [-40°F – 149°F]
Mechanical
Dimensions 3U [5.25”, 133mm], 19” [483mm] mounting,
H,W,D 14” [356mm]*
System
System SC200 as standard.
Controller SC100 optional.
DC Distribution 10-way circuit breakers (2 x Battery, 8 x Load).
Module Load circuit breakers: Heinemann AMIR Series
5A,10A, 20A, 30A, 40A, 50A, 70A, 80A, 100A.
Battery circuit breakers: Heinemann AMIR 100A or
AMIP 120A.
Communication USB direct*
Features 10BaseT Ethernet*, TCP/IP*, SNMP*, Modbus-
TCP*, Modbus-RTU* and on board web server*
RS232 to external PSTN or GSM modem (modem
not included)
*SC200 only
Low Voltage Battery disconnect: 200A internal.
Disconnect
(LVD)
Rectifier Blank For unused rectifier positions.
Panels
Options Relay Rack
Batteries.
Output
DC Output 43 – 57.5V
Voltage Range
DC Output Rectifier type: APR48-3G APR48-ES
Power 110/120V AC: 6.6kW @ 48V 6.9kW @ 48V
(maximum) 208-240V AC: 10.8kW @ 48V 12kW @ 48V
Environmental
Temperature
Range Rated: -10°C to +45°C [14°F to +122°F]
Mechanical
Dimensions 6U [10.5”, 267mm], 19” [483mm] mounting,
H,W,D 15.3” [390mm]*
System
System SC200 as standard.
Controller SC100 optional.
DC Distribution 26-way circuit breakers (6 x Battery, 20 x Load).
Module Load circuit breakers: Heinemann AMIR Series
5A,10A, 20A, 30A, 40A, 50A, 70A, 80A, 100A, 120A
(2-pole).
Battery circuit breakers:
6 x Heinemann AMIR 80A, 100A
or 3 x Heinemann AMIP 120A, 150A, 200A.
Communication USB direct.
Features of 10BaseT Ethernet, TCP/IP, SNMP, On board web
SC200 server.
RS232 to external PSTN or GSM modem (modem
not included).
Low Voltage Battery disconnect: 400A internal.
Disconnect Non priority load: 200A internal.
(LVD) (Optional)
Rectifier Blank For unused rectifier positions.
Panels
Options Relay Rack
Batteries.
Output Europe CE
DC Output 43 – 57.5V Australia / C-tick
Voltage Range New Zealand
DC Output APR48-3G : 17.2kW @ 48V
Power APR48-ES : 17.2kW @ 48V In the interests of continual product improvement all specifications are
(maximum) * * Ratings are stated without LVD’s fitted. In some subject to change without notice.
cases lower ratings may result when LVDs are
used. Refer to installation guide for detailed load
specs and MCB de-rating factors.
Environmental
Operating -40°C to +70°C [-40°F to +158°F]
Temperature Output current is derated above 40°C [104°F] and
Range below -10°C [14°F]
Mechanical
Dimensions 9U, 19” mounting, 335mm [12.4”]*
H,W,D
* Additional clear space is required for exhaust air.
System
System SC200 or SC100
Controller
DC Distribution 20-way circuit breakers (4 x Battery, 16 x Load)
Module
Communication USB direct*
Features 10BaseT Ethernet*, TCP/IP*, SNMP*, Modbus-
TCP*, Modbus-RTU* and on board web server*
RS232 to external PSTN or GSM modem (modem
not included)
*SC200 only
Low Voltage Optional battery LVD, or non priority LVD, or battery
Disconnect and non priority LVD’s. (Contactors 400A
(LVD) rated)
Rectifier Blank For unused rectifier positions
Panels
Options External Surge Protection