ISSUE RECORD

GOOD FOR CONST PRELIMINARY DESIGN


DESIGN DEVELOPMENT TENDER DRAWINGS

REFERENCE DESIGN DOCUMENT :-


1. FOR PSC PRE-TENSIONED GIRDER DESIGN REFER NO:
BEARING/ BEARING/
MEGA-STAA-STN-EW-R2-GJUV-STR-DN-211
DIAPHRAGM DIAPHRAGM
OF GIRDER
REFERENCE DRAWING :-
1. FOR GENERAL NOTES:
MEGA-STAA-STN-EW-R2-GJUV-STR-GFC-0404 & 0405

A
2. FOR CONCOURSE LEVEL FRAMING PLAN:
MEGA-STAA-STN-EW-R2-GJUV-STR-GFC-0106
3. FOR DETAILS OF PSC PRE-STRESSING:
MEGA-STAA-STN-EW-R2-GJUV-STR-GFC-0348 & 0349 .
4. FOR DETAILS OF REINFORCEMENT FOR PSC PRE-TENSION:
MEGA-STAA-STN-EW-R2-GJUV-STR-GFC-0294

LEGENDS :- ABBREVIATIONS :-
CL - CENTER LINE
TYP. - TYPICAL
CB - CONCOURSE LEVEL PRECAST BEAM

NOTE :-
1. ALL DIMENSIONS ARE IN MILLIMETERS
2. DO NOT SCALE THE DRAWING. FOLLOW THE FIGURED
DIMENSIONS ONLY.
3. GRADE OF CONCRETE:

LONGITUDINAL ELEVATION M35 - DECK SLAB


M50 - PSC I GIRDER
SCALE: 1:25 4. THIS DRAWING MUST BE READ IN CONJUNCTION WITH CONCOURSE
LEVEL FRAMING PLAN:MEGA-STAA-STN-EW-R2-GJUV-STR-GFC-0106
5. ALL PRECAUTIONS ARE TO BE TAKEN AS PER IRC.SP-71-2006 &
OTHER RELEVANT LITERATURES DURING CASTING & ERECTIONS.
BEARING/ BEARING/
DIAPHRAGM DIAPHRAGM

OF GIRDER
OF GIRDER

GOOD FOR CONSTRUCTION

REVISION CONTROL

PLAN
SCALE 1:25
R0 ISSUED FOR CONSTRUCTION
REV. NO. DATE DESCRIPTION OF CHANGES /CLOUDING

NO OBJECTION FOR CONSTRUCTION

MANAGER (DC)

ONLY FOR CB6


*# , # ONLY FOR CB5
GM/SYS GM/S&T GM (P&D)

ONLY FOR CB5a


GENERAL ENGINEERING CONSULTANT
* CONSORTIUM OF SYSTRA-RITES-OCG-AECOM
SCHEDULE OF DIMENSION FOR GIRDER THE DESIGN AND DRAWING AS CERTIFIED AND SUBMITTED BY THE DETAILED DESIGNER CONSULTANT HAVE BEEN PROOF CHECKED BY
GENERAL ENGINEERING CONSULTANTS AND IS RECOMMENDED FOR NO OBJECTION BY MEGA

SR.No. L* L** REMARKS


CSE CTE CTRAE CIE

1 15050 10150 CB5, CB6 & CB5a


CDA CSDE CDE (E & M) PD (DY. P.D.)
CLIENT :
METROLINK EXPRESS GANDHINAGAR AND AHMEDABAD
DETAILED DESIGN CONSULTANT (DDC) : OFFICE OF ORIGIN
STUP Consultants Pvt. Ltd
Plot No: 22A, Sector 19-C, Palm Beach Marg,
Vashi, Navi Mumbai - 400705. IN CONSORTIUM WITH
Tel: 022-40887777, Fax: 022-27836240
E-mail: navimumbai@stupmail.com

THE RESPONSIBILITY OF CONTROL, CHECK AND VERIFICATION OF ACCURACY


CORRECTNESS,COMPLETENESS,INTEGRATION AND FULL COMPLIANCE OF CONTRACT PROVISIONS
IN RESPECT OF DESIGN ANALYSIS AND DRAWING RESTS WITH THE DESIGNER
DETAILED DESIGN CONSULTANCY SERVICES FOR CIVIL ARCHITECTURAL AND BUILDING
PROJECT NAME : SERVICES INCLUDING E&M WORKS FOR ELEVATED METRO-RAIL STATIONS-SEVEN (7) NUMBERS
FROM (THALTEJ GAM, THALTEJ, DOORDARSHAN KENDRA, GURUKUL ROAD, GUJARAT UNIVERSITY,
COMMERCE SIX ROAD, STADIUM ON EAST WEST CORRIDOR ON REACH-2 (WESTERN REACH) OF
AHMEDABAD METRO RAIL PROJECT FOR THE METRO LINK EXPRESS FOR GANDHINAGAR &
AHMEDABAD (MEGA) COMPANY LTD.
CONTRACT ID : MEGA/DDC/ELEV-STNS/E-W/R-2/2016/LoA/Date: 27-01-2016
DRAWING NAME/TITLE :
SECTION A SECTION B SECTION C
SCALE: 1:10 - SCALE: 1:10 - SCALE: 1:10 - DRAWING NO. : SHEET NO. : 1 OF 1
MEGA-STAA-STN-EW-R2-GJUV-STR-GFC-0184
SCALE : AS SHOWN DATE : 07.10.17
IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM & CONDITION OF
CONTRACT AND WE OWN FULL RESPONSIBILITY FOR DESIGN, ADEQUACY & MEETING FUNCTIONAL,
PERFORMANCE AND OPERATIONAL REQUIREMENTS INCLUDING CONSIDERATION FOR INTERFACE
REQUIREMENT OF OTHER CONCERNED DESIGNER/ CONTRACTOR AND COMPLIANCE TO STANDARDS,
NORMS, SAFETY AND STATUTORY RULES & REGULATIONS.

SANTHOSH SHEHBAZ VV RAMAYYA VV RAMAYYA


PREPARED BY CHECKED BY APPROVED BY ISSUED BY
FILE NAME: Y:\PROJECTS\1858-MEGA DDC - 5 STATIONS\ MEGA-STAA-STN-EW-R2-GJUV-STR-GFC-0184-R0-(GAD)- (07.10.17).DWG SHEET SIZE: A1 PLOTTING SCALE 1:1
Xref Z:\1961-MEGA EW 7 stations\30- Generated Documents\32 - Drawings\Template\R0-11.03.216\XREF EW-MEGA NAME PLATE-A1-R0(without key plan).dwg