PARAMETROS ABB BEAM1xlsx

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

[DRIVEWINDOW 2.

0 Report File]
12/3/13 9:55

ROD PUMP CTRL {0}{1}

Parameters, 01: SENALES ACTUALES

NAME VALUE MINIMUM MAXIMUM


01.01: VELOCIDAD [rpm] 650,22339
01.02: VELOC ESTIMADA [rpm] 652,37036
01.03: FRECUENCIA [Hz] 33,199432 -500 499,999939
01.04: CORRIENTE [A] 93,983093 -1289,761475 1289,76123
01.05: TORQUE [%] 75,36438 -1877,860107 1877,859863
01.06: TORQUE ESTIM [%] 80,12204
01.07: POTENCIA [%] 41,326523 -1000 999,9998779
01.08: TENSION BUS CC V [V] 639,84399 -4051,418945 4051,418457
01.09: TENSION DE RED [V] 452,21448 0 9999,998047
01.10: TENSION DE SALIDA [V] 265,73303 249,9997559 999,9990234
01.11: TEMP DEL ACS800 [C] 69,972046 -1000 999,9998779
01.12: HORAS OPER [h] 19538,18
01.13: TEMP AUTO-REAJST [min] 1 0 100000000
01.14: KILOWATIOS HORA [kWh] 231251,28 0 16609382
01.15: TEMP MOTOR 1 [C] 0 -5000 5000
01.16: TEMP MOT EST [C] 53,266289 -1000 999,9998779
01.17: TEMP1 BMB [C] 0 -10000 10000
01.18: TEMP2 BMB [C] 0 -10000 10000
01.19: ESTADO ED6 - 1 0X45
01.20: ESTADO SR3 - 1 0X3
01.21: EA1 (V) 0,0040400103 0 10
01.22: EA2 (mA) 0 0 22
01.23: EA3 (mA) 0 0 22
01.24: SA1 (mA) 4,0534124 0 22
01.25: SA2 (mA) 19,99955 0 22
01.26: ESTADO XT ED6-1 0X0
01.27: ESTADO XT SR6-1 0X0
01.28: XT EA1 [%] 0 0 150
01.29: XT EA2 [%] 0 0 150
01.30: XT EA3 [%] 0 0 150
01.31: XT EA4 [%] 0 0 150
01.32: XT EA5 [%] 0 0 150
01.33: XT EA6 [%] 0 0 150
01.34: XT SA1 [mA] 0 0 22
01.35: XT SA2 [mA] 0 0 22
01.36: XT SA3 [mA] 0 0 22
01.37: XT SA4 [mA] 0 0 22
01.38: TEN MIN ARRANQUE [lb] 0 0 100000000
01.39: TEN MAX ARRANQUE [lb] 0 0 100000000
01.40: TEN MIN PARO [lb] 0 0 100000000
01.41: TEN MAX PARO [lb] 0 0 100000000
01.42: TEN MIN OPERAC [lb] 0 0 100000000
01.43: TEN MAX OPERAC [lb] 0 0 100000000
01.44: TEN MIN CICLO [lb] 0 0 100000000
01.45: TEN MAX CICLO [lb] 0 0 100000000
01.46: TIEMPO CICLO VACIO [min] 0 0 100000000
01.47: CONT CICLO BOMB 0X0
01.48: TMPO FALLA VACIO [min] 607 0 100000000
01.49: CONT FALLA BOMBA 0X0
01.50: LUGAR DE CONTROL EXT1

Parameters, 02: SENALES ACTUALES

NAME VALUE MINIMUM MAXIMUM


02.01: REF VELOCIDAD 2 [rpm] 656,45081 525,3981934 1050,554199
02.02: REF VELOCIDAD 3 [rpm] 656,45081 525,3981934 1050,554199
02.03: REF VELOCIDAD 4 [rpm] 656,45081 525,3981934 1050,554199
02.04: REF TORQUE 1 [%] 0 -300 300
02.05: REF TORQUE 2 [%] 13,253983 -1877,860107 1877,859863
02.06: REF TORQUE 3 [%] 9,7884312 -1877,860107 1877,859863
02.07: REF TORQUE 4 [%] 10,851088 -1877,860107 1877,859863
02.08: REF TORQUE 5 [%] 13,900261 -1877,860107 1877,859863
02.09: REF TORQUE USUDA [%] 14,884119 -1408,39502 1408,39502
02.10: REF VELO USADA [rpm] 656,45081 525,3981934 1050,554199
02.11: CORRIENTE MTR IA [A] 96,991592 0 10000
02.12: CORRIENTE MTR IB [A] 95,586075 0 10000
02.13: CORRIENTE MTR IC [A] 99,510605 0 10000
02.14: CODIG DE EST 0X1F37
02.15: PUMP STATUS WRD1 0X8000
02.16: PUMP STATUS WRD2 0X4000
02.17: CODIGO FALLO 1 0X0
02.18: CODIGO FALLO 2 0X0
02.19: CODIGO ALARMA 1 0X0
02.20: CODIGO LIMITE 0X0

Parameters, 03: ACTUALES BALANCIN

NAME VALUE MINIMUM MAXIMUM


03.01: POTENCIA [Hp] 42,357193 0 10000
03.02: TORQUE BOMBA [lbft] 242,84082 -10000 10000
03.03: TENSION CABL [lb] 0 0 100000000
03.04: POSICION CALC [%] 100 -100 100
03.05: VELOC CALC BOMB [spm] 4,9925385 -10000 10000
03.06: CAMB VEL BOMB [rpm] 0 -10000 10000
03.07: TIEMPO OPER [min] 524 0 100000000
03.08: 24H TMP OPER [min] 1357 0 100000000
03.09: TMP REMA OPER [min] 15 0 100000000
03.10: TMP REMA LLENA [min] 30 0 100000000
03.11: POSICION STROKE [%] 100 0 100
03.12: STROCK BOMB UPSTROKE
03.13: CONT STROCK [stk] 0,5 0 100000000
03.14: APC SPD INC COUNT 0X0
03.15: PEAK TORQUE [%] 76,787903 0 500
03.16: ENERGY PER STRK [KWS] 2102,3486 0 100000000
03.17: CONT ALTO CARGA 0X0
03.18: CONT MIN CARGA 0X0
03.19: FLUJO PRODUCCION [Brl] 0,14042872 0 100000000
03.20: 24H PRODUCCION [Brl] 0,14042872 0 100000000
03.21: RATA PRODUCCION [Bpd] 2019,3035 0 10000
03.22: PRESION CASING [psi] 0 0 10000
03.23: PRESION TUBING [psi] 0 0 10000
03.24: PRESION INTAKE [psi] 0 0 10000
03.25: VELOC MED SPM [spm] 23,076923 -10000 10000

Parameters, 04: INFORMACION APLIC

NAME VALUE MINIMUM MAXIMUM


04.01: SW PACKAGE VER BRXR3300
04.07: APPL NAME BRAR3300
04.09: APPL RELEASE DATE APR 23, 2008
04.10: BOARD TYPE RMIO - 0X

Parameters, 06: ENTRADA FIELDBUS

NAME VALUE MINIMUM MAXIMUM


06.01: PALB COMAND 0X0
06.02: REF VELOC 1 0X0
06.03: REF VELOC 2 0X0
06.04: COMAND BOMBA 0X0
06.05: INPUT DATA WORD5 0X0
06.06: INPUT DATA WORD6 0X0
06.07: INPUT DATA WORD7 0X0
06.08: INPUT DATA WORD8 0X0
06.09: INPUT DATA WORD9 0X0

Parameters, 09: SEÐALES ACTUALES

NAME VALUE MINIMUM MAXIMUM


09.01: EA1 ESCALADA 0X8
09.02: EA2 ESCALADA 0X0
09.03: EA3 ESCALADA 0X0
09.04: XT EA1 ESCALADA 0X0
09.05: XT EA2 ESCALADA 0X0
09.06: LCU ACT SIGNAL1 0XB8E
09.07: LCU ACT SIGNAL2 0X158
09.08: XT EA3 ESCALADA 0X0
09.09: XT EA4 ESCALADA 0X0
09.10: XT EA5 ESCALADA 0X0
09.11: XT EA6 ESCALADA 0X0

Parameters, 10: MARCHA/PARO/DIR

NAME VALUE MINIMUM MAXIMUM


10.01: EXT1 MAR/PARO ED1
10.02: EXT2 MAR/PARO ED1
10.03: DIRECCION AVANCE
10.04: PERMISO DE MARCHA YES

Parameters, 11: SELEC REFERENCIA

NAME VALUE MINIMUM MAXIMUM


11.01: SELEC EXT1/EXT2 SIN SEL
11.02: SELEC REF EXT1 PANEL PARA ARRANQUE PANEL-PARA SAM AI1
11.03: REF EXT1 MINIMO [spm] 3,9994993 0 18000
11.04: REF EXT1 MAXIMO [spm] 7,997159 0 18000
11.05: SELEC REF EXT2 PANEL
11.06: REF EXT2 MINIMO [spm] 3,9994993 0 18000
11.07: REF EXT2 MAXIMO [spm] 7,997159 0 18000

Parameters, 12: VELOC CONSTANTES

NAME VALUE MINIMUM MAXIMUM


12.01: SEL VELOC CONST SIN SEL
12.02: VELOC CONST 1 [rpm] 500 -500 500
12.03: VELOC CONST 2 [rpm] -500 -500 500

Parameters, 13: ENTRADAS ANALOG

NAME VALUE MINIMUM MAXIMUM


13.01: MINIMO EA1 0V
13.02: ESCALA EA1 100 50 500
13.03: FILTRO EA1 10 1 10000
13.04: MINIMO EA2 4 mA
13.05: ESCALA EA2 100 50 500
13.06: FILTRO EA2 100 1 10000
13.07: MINIMO EA3 4 mA
13.08: ESCALA EA3 100 50 500
13.09: FILTRO EA3 100 1 10000
13.10: MINIMO XT EA1 20%
13.11: ESCALA XT EA1 100 50 500
13.12: FILTRO XT EA1 100 1 10000
13.13: MINIMO XT EA2 20%
13.14: ESCALA XT EA2 100 50 500
13.15: FILTRO XT EA2 100 1 10000
13.16: MINIMO XT EA3 20%
13.17: ESCALA XT EA3 100 50 500
13.18: FILTRO XT EA3 100 1 10000
13.19: MINIMO XT EA4 20%
13.20: ESCALA XT EA4 100 50 500
13.21: FILTRO XT EA4 100 1 10000
13.22: MINIMO XT EA5 20%
13.23: ESCALA XT EA5 100 50 500
13.24: FILTRO XT EA5 100 1 10000
13.25: MINIMO XT EA6 20%
13.26: ESCALA XT EA6 100 50 500
13.27: FILTRO XT EA6 100 1 10000

Parameters, 14: SALIDAS DE RELE

NAME VALUE MINIMUM MAXIMUM


14.01: DO1 GROUP+INDEX 214 0 2000
14.02: DO1 BIT NUMBER 1 0 23
14.03: DO2 GROUP+INDEX 214 0 2000
14.04: DO2 BIT NUMBER 2 0 23
14.05: DO3 GROUP+INDEX 216 0 2000
14.06: DO3 BIT NUMBER 13 0 23
14.07: XTDO1 GROUP+INDEX 215 0 2000
14.08: XTDO1 BIT NUMBER 0 0 15
14.09: XTDO2 GROUP+INDEX 215 0 2000
14.10: XTDO2 BIT NUMBER 2 0 15

Parameters, 15: SALIDAS ANALOG

NAME VALUE MINIMUM MAXIMUM


15.01: SALIDA ANALOG 1 304 0 10000
15.02: INVERTIR EA1 NO
15.03: MINIMO SA1 4 mA
15.04: FILTRO SA1 10 0 10000
15.05: ESCALA SA1 30000 0 1000000
15.06: SALIDA ANALOG 2 311 0 10000
15.07: INVERTIR SA2 NO
15.08: MINIMO SA2 4 mA
15.09: FILTRO SA2 10 0 10000
15.10: ESCALA SA2 100 0 1000000
15.11: XT SALIDA ANALO1 303 0 10000
15.12: INVER XTSA1 NO
15.13: MINIM XTSA1 4 mA
15.14: FILTRO XTSA1 300 0 10000
15.15: ESCAL XTSA1 30000 0 1000000
15.16: XT SALIDA ANALO2 305 0 10000
15.17: INVER XTSA2 NO
15.18: MINIM XTSA2 4 mA
15.19: FILTRO XTSA2 500 0 10000
15.20: ESCAL XTSA2 18 0 1000000
15.21: XT SALIDA ANALO3 311 0 10000
15.22: INVER XTSA3 NO
15.23: MINIM XTSA3 4 mA
15.24: FILTRO XTSA3 300 0 10000
15.25: ESCAL XTSA3 100 0 1000000
15.26: XT SALIDA ANALO4 323 0 10000
15.27: INVER XTSA4 NO
15.28: MINIM XTSA4 4 mA
15.29: FILTRO XTSA4 300 0 10000
15.30: ESCAL XTSA4 500 0 1000000

Parameters, 16: ENTR CONTR SIST

NAME VALUE MINIMUM MAXIMUM


16.01: SEL RESTAUR FALLO MODULO COMUN
16.02: BLOQUEO PARAMETRO ABIERTO
16.03: CODIGO ACCESO 0 0 30000
16.04: BLOQUEO LOCAL NO
16.05: SALVAR PARAMETROS DONE

Parameters, 20: LIMITES

NAME VALUE MINIMUM MAXIMUM


20.01: VELOCIDAD MINIMA [rpm] 525,39819 -5999,999023 1050,554199
20.02: VELOCIDAD MAXIMA [rpm] 1050,5542 525,3981934 5999,999023
20.04: CORRIENTE MAXIMA [%Ihd] 180 0 204,9994812
20.05: RUN SPC TRQMAX [%] 300 0 300
20.06: SPC TORQMIN [%] -300 -600 0
20.07: FREQ TRIP MARGIN [Hz] 54 0 499,9949951
20.08: CTRL SOBRETENSION SI

Parameters, 21: MARCHA/PARO

NAME VALUE MINIMUM MAXIMUM


21.01: FUNCION MARCHA MAGN CC CNST
21.02: TIEMPO MAGN CONST [ms] 1000 30 10000
21.03: FUNCION PARO PARO LIBRE

Parameters, 22: ACEL/DECEL

NAME VALUE MINIMUM MAXIMUM


22.01: TIEMPO ACELER 1 [s] 5 0 1800
22.02: TIEMPO DECELER 1 [s] 0 0 1800
22.03: TIPO RAMPA ACE/DE [s] 0 0 1000

Parameters, 23: REF VELOCIDAD


NAME VALUE MINIMUM MAXIMUM
23.01: REF VELOCID [rpm] 656,45081 525,3981934 1050,554199
23.02: MULTIPLI VEL [%] 100 0 500
23.03: CORREC VEL [rpm] 0 -5999,999023 5999,999023
23.04: REF SPD ADD [rpm] 0 -5999,999023 5999,999023

Parameters, 24: CTRL VELOCIDAD

NAME VALUE MINIMUM MAXIMUM


24.01: MARCHA AUTOAJUSTE NO
24.02: DAMPENING COEF 2 0,0160007477 8
24.03: GANANCIA 11,999966 0 250
24.09: TIEMP INTEGRACION [s] 0,29993057 0,0100135803 999,9990234
24.10: INTEG INIT VALUE [%] 0 -300 300
24.11: DROOP RATE [%] 0 0 100
24.12: TIEMPO DERIVACION [ms] 0 0 9999,990234
24.13: DERIV FILT TIME [ms] 7,9870224 0 100000,0312
24.14: COMPENSACION ACE [s] 0 0 999,9998779
24.15: ACC COMP FILT [ms] 7,9870224 0 999999
24.16: GANANCIA DESLZMTO [%] 100 0 399,999939
24.21: TIEMP FILT VELACT [ms] 7,9870224 0 999999

Parameters, 27: CHOPPER

NAME VALUE MINIMUM MAXIMUM


27.01: CTRL CHOPPER OFF
27.02: FUNC SOBREC RESIS NO
27.03: VALOR RESIST [Ohm] 99,999908 0 99,99990845
27.04: CONST TERM RESIS [s] 0 0 9999,998047
27.05: POT FREN CONT MAX [HP] 0 0 9999,998047
27.06: MODO CTRL CHOPPER COMMON DC

Parameters, 30: FUNCIONES FALLOS

NAME VALUE MINIMUM MAXIMUM


30.01: MODO PROT TERM MO DTC/KLIXON DI6 DTC SIN TERMISTOR INSTALADO/KLIXON DI6 SI EL TERMISTOR SE CONECTO
30.02: PROT TERMICA MOT FALLO
30.03: M1 TEMP AI1 KEUZE SIN USAR
30.04: MOT1 TEMP ALM L [C] 90 -10 10000
30.05: MOT 1 TEMP FT L [C] 120 -10 10000
30.09: TIEMPO TERM MOTOR [s] 3359,9854 255,9995728 9999,900391
30.10: CURVA CARGA MOTOR [%] 100 50 150
30.11: CARGA VELOC CERO [%] 74 25 150
30.12: PUNTO RUPTURA [Hz] 53,999962 0,999987125 300
30.16: FUNC BAJA CARGA NO
30.17: TIEMPO BAJA CARGA [s] 20 0 600
30.18: CURVA BAJA CARGA 4
30.19: FALLO FASE MOTOR NO
30.20: FALLO A TIERRA FALLO
30.21: LVL FALLA TIERRA 3 0 8
30.22: EA<FUNCION MINIMA NO
30.23: FALLO PANEL ULTIMA VELOC
30.24: FALLO EXTERNO SIN SEL

Parameters, 34: AUT RESET FALLA

NAME VALUE MINIMUM MAXIMUM


34.01: SOBRETENSION OFF
34.02: SUBTENSION SI
34.03: OVRFREQ_SPD RESET OFF
34.04: CTRL HCASE PRES OFF
34.05: CTRL HTUBE PRES OFF
34.06: SENAL EA<MIN OFF
34.07: CTRL TEMP OFF
34.08: NUM REARRANQ 3 0 20
34.09: RETR TMP FUERA [min] 1 0 100000
34.10: TMP RETRAZO [min] 4 0 100000
34.11: PRESS SW RESET SI
34.12: LINE CONV RESET SI

Parameters, 52: MODBUS ESTANDAR


NAME VALUE MINIMUM MAXIMUM
52.01: NUM ESTACION 1 1 247
52.02: VEL TRANSM 9600
52.03: PARIDAD 1 STOP BIT

Parameters, 70: CONTROL DDCS

NAME VALUE MINIMUM MAXIMUM


70.01: DIREC CANAL 0 1 0 254
70.02: VEL TRANSM CH 0 1 Mbit/s
70.03: CH0 TIMEOUT [ms] 3000 0 60000
70.04: CH0 COM LOSS CTRL NO ERR CHK
70.12: DIREC CANAL 3 1 1 254

Parameters, 71: CONTROL BOMBA

NAME VALUE MINIMUM MAXIMUM


71.01: RANGO CELDCARGA [lb] 30000 0 1000000
71.02: MAX CARG CAB [lb] 15000 0 1000000
71.03: MIN CARG CAB [lb] 4000 0 1000000
71.04: VEL MAX BOMBA [spm] 8 0 100 PARA EL ARRANQUE INICIAL OPCIONAL DEPENDE DEL MONTAGE
71.05: VEL MIN BOMBA [spm] 4 0 100 PARA EL ARRANQUE INICIAL OPCIONAL DEPENDE DEL MONTAGE
71.06: VEL ARRANQUE [spm] 5 0 100 PARA EL ARRANQUE INICIAL
71.07: TMP VEL ARR [s] 4 0 100 PARA EL ARRANQUE INICIAL
71.08: DIAM POL MOTOR [inch] 11 0 1000000 PARA EL ARRANQUE INICIAL MEDIR LA POLEA DEL MOTOR
71.09: DIAM POL UNID [inch] 52 0 1000000 PARA EL ARRANQUE INICIAL SEGÚN UNIDAD
71.10: RATA CAJAREDUC [ :1] 28 0 100 PARA EL ARRANQUE INICIAL SEGÚN PLACA CAJA REDUCTORA UNIDAD
71.11: EFICIENCIA BOMBA [%] 80 0 100
71.12: DIAMETRO BOMBA [inch] 5,4880457 0 1000000
71.13: LARGO STROKE [inch] 143,99991 0 1000000
71.14: CONT MAX CARGCAB 4 0 10
71.15: TMP MIN CARG CAB [s] 5 1 100
71.16: LIM MINCARG SPAN [lb] 4000 0 1000000
71.17: CNT MINCARG SPAN 3 0 12
71.18: FNC FALL CELCARGA NO FALLO
71.19: SL PERD CARG/INCL CTRL ON/OFF
71.20: SEL ENT INCLINO NO INCLINE
71.21: PUMPING UNIT TYPE MARK 2
71.22: SEL EA CELCARG SIN SEL
71.23: HABILITAR BOMBA NO HABILITAD PARA EL ARRANQUE INICIAL
71.24: VALID RUN CNT LIM 5 0 100
71.25: TMP OPERAC BOMB [min] 15 1 1440
71.26: TMP LLENADO BMB [min] 30 1 1440
71.27: SEL REF CTRL SENO 0 10000
71.28: VAL NOM CTRL SENO 0 1000000
71.29: FLT REF CTRL SENO [ms] 0 1000000
71.31: START DELAY [s] 2 0 100 PARA EL ARRANQUE INICIAL
71.32: START TORQ LIM [%] 300 0 300

Parameters, 72: ON/OFF & CTRL SENO

NAME VALUE MINIMUM MAXIMUM


72.01: POS VEL UPSTROKE [%] 75 0 99
72.02: POS VE1 DWNSTROKE [%] 70 0 99
72.03: AJT VEL DWNSTROKE [%] 2,9999757 -100 100
72.04: LIM MIN CARGA [lb] 1000 0 100000
72.05: HYST MIN CARGA [lb] 4000 0 100000
72.06: CONT MIN CARGA 3 1 100
72.07: VEL C MINCARGA [spm] 1,999999 0 100

Parameters, 74: SUPERVISION BOMB

NAME VALUE MINIMUM MAXIMUM


74.03: FUNC TEMP KLIXON NO
74.04: SEL TEMP KLOXON1 SIN SEL
74.05: CMB VEL TEMP MTR [spm] 1 0 20
74.06: SEL TIPO TEMP1 TEMP BEARING
74.07: FUNC TEMP1 BMB NO
74.08: SEL EA TEMP1 BMB EA5
74.09: ALM TEMP1 BMB [C] 170 0 500
74.10: LIM ALT TEMP1 BMB [C] 190 0 500
74.11: CMB VEL TEMP1 BMB [s] 1800 0 86400
74.12: MAX TEMP1 BMB [C] 302 0 500
74.13: SEL TIPO TEMP2 TEMP BEARING
74.14: FUNC TEMP2 BMB NO
74.15: SEL EA TEMP2 BMB EA6
74.16: ALM TEMP2 BMB [C] 170 0 500
74.17: LIM ALT TEMP2 BMB [C] 190 0 500

74.18: CMB VEL TEMP2 BMB [s] 1800 0 86400


74.19: MAX TEMP2 BMB [C] 302 0 500
74.20: CMB VEL TEMP BMB [spm] 1 0 20
74.21: FUNCION PRESION FAULT PARA EL ARRANQUE INICIAL
74.22: SEL PRES CASING SIN SEL
74.23: MAX PRES CASING [psi] 50 0 1000
74.24: LIM PRES CASING [psi] 40 0 1000
74.25: SEL PRES TUBING SIN SEL
74.26: MAX PRES TUBING [psi] 500 0 1000
74.27: LIM ALT P TUBING [psi] 300 0 1000
74.28: LIM BAJ P TUBING [psi] 20 0 1000
74.29: TMP LIM PRESION [s] 1 1 1000 PARA EL ARRANQUE INICIAL
74.30: SEL PRES INTAKE SIN SEL
74.31: MAX PRES INTAKE [psi] 500 0 5000
74.32: HIGH PRES SWITCH DI5 PARA EL ARRANQUE INICIAL
74.33: PACKING SWITCH SIN SEL

Parameters, 75: VAL REAJUSTES

NAME VALUE MINIMUM MAXIMUM


75.01: REAJST 24Hor ACT NO REAJUSTAR
75.02: REAJST TEN ARRAQ NO REAJUSTAR
75.03: REAJST TEN PARO NO REAJUSTAR
75.04: RAJT CIC TMP/CNT NO REAJUSTAR
75.05: RAJUT TMP/CNT NO REAJUSTAR
75.06: RST TMP PRODCC SIN SEL

Parameters, 76: LIMIT TORQ

NAME VALUE MINIMUM MAXIMUM


76.01: FUNC TORQ MOTOR SIN SEL
76.02: LIM ALT TORQ MTR [lbft] 445,11554 0 10000
76.03: TMP ALT TORQ MTR [s] 30 0 86400
76.04: VEL ALT TRQ MTR [spm] 4 0 20
76.05: CONT ALTO TORQ 5 0 100
76.06: LIM BAJO TRQ MTR [lbft] 80,117432 0 10000
76.07: TMPO BAJ TRQ MTR [s] 60 0 86400

Parameters, 90: ENTRAD FIELDBUS

NAME VALUE MINIMUM MAXIMUM


90.01: INPUT DATA WORD5 0 0 10000
90.02: INPUT DATA WORD6 0 0 10000
90.03: INPUT DATA WORD7 0 0 10000
90.04: INPUT DATA WORD8 0 0 10000
90.05: INPUT DATA WORD9 0 0 10000

Parameters, 92: SALIDAS FIELDBUS

NAME VALUE MINIMUM MAXIMUM


92.01: OUTPUT DATA WORD1 214 0 10000
92.02: OUTPUT DATA WORD2 215 0 10000
92.03: OUTPUT DATA WORD3 216 0 10000
92.04: OUTPUT DATA WORD4 305 0 10000
92.05: OUTPUT DATA WORD5 303 0 10000
92.06: OUTPUT DATA WORD6 307 0 10000

Parameters, 95: HARDWARE SPECIF

NAME VALUE MINIMUM MAXIMUM


95.01: MODO CTRL VENT CONTROLADO
95.05: PERM INC FREQ CON NO
95.06: LCU Q PW REF 0 -10000 10000
95.07: LCU DC REF 0 0 1100
95.08: LCU PAR1 SEL 116 0 10000
95.09: LCU PAR2 SEL 117 0 10000
95.10: TEMP INV AMBIENT [C] 39,999962 0 49,99995422

Parameters, 98: MODULOS OPCIONAL

NAME VALUE MINIMUM MAXIMUM


98.02: MODULO COMUNIC MODBUS ESTAN

98.03: MOD EXT 1 E/S NO


98.04: MOD EXT 2 E/S NO
98.06: MODULO EXT1 E/S A NO
98.07: MODULO EXT2 E/S A NO
98.08: MODULO EXT3 E/S A NO
98.10: DI DEBOUNCE FILT 50 50 1000

Parameters, 99: DATOS DE PARTIDA

NAME VALUE MINIMUM MAXIMUM


99.01: IDIOMA ESPANOL
99.02: MACRO APLICACION DUAL SPD CTR
99.03: RESTAURAR APLIC SI PRIMER PASO ANTES DE PROGRAMAR
99.04: MODO CTRL MOTOR DTC
99.05: TENSION NOM MOTOR [V] 459,9762 249,9997559 999,9990234 VOLTAGE DE PLACA MOTOR
99.06: INTENS NOM MOTOR [A] 115,9799 0 341,9995117 CORRIENTE DE PLACAMOTOR
99.07: FREC NOM MOTOR [Hz] 60 8,000015259 300 FRECUENCIA DE PLACA MOTOR
99.08: VELOC NOM MOTOR [rpm] 1179,9336 1,001358032 17999,99609 VELOCIDAD RPM PLACA MOTOR
99.09: POTENCIA NOM MOT [HP] 74,599976 0 9000 POTENCIA PLACA NOMINAL MOTOR ( KW - HP )
99.10: MARCHA IDENT MOT ID MAGN
99.11: TORQUE MOTOR CALC [lbft] 332,05182 0 10000
99.12: COMPL/CORTO MENU FULL MENU