1 DESIGN CALCULATION COVER ACCESS

1a DESIGN OF HORIZONTAL MEMBER

Due Live Load

A 20.11 kN/m B

1.8 m

0.3 m
6.75 kN/m
A B

1.8 m

Span = 1.8 m
Loaded width = 1.125 m
Live Load = 5 kN/m2
Finishes = 1.25 kN/m2
Slab Selfweight 65mm thk = 1.625 kN/m2
Wheel Load = 6.75 kN
Factored Load = 11.38125 kN/m2
Udl 1 = 12.80 kN/m
Udl 2 = 10.13 kN/m

Page 1 of 5
Project title : PROPOSED CONDOMINIUM HOUSING 04/05/2023
DEVELOPMENT COMPRISING 12 BLOCKS OF 11/12/13 STOREY

Moment max 1, MEd = 5.19 kNm


Shear max 1 = 11.52 kN

Moment max 2, MEd = 4.25 kNm


Shear max 2 = 9.28 kN

Total moment = 9.44 kNm


Total Shear = 20.80 kN

Using Py Steel = 275 N/mm2

Required Sx = M/Py = 34.325 cm3

USE PROFILE 150X100X9mm-SHS


A = 39.67 cm2
D = 150 mm
t(w) = 10 mm
B = 100 mm
Zx = 150.5 cm3
ry = 3.87 cm
rX = 5.33 cm
T(f) = 10 mm
E = 210000 N/mm2
Ix = 1129 cm4
fy = 275 N/mm2

Shear Capacity
VPL, Rd = AV (fy/√3)γM0
AV = 2967 mm2

VPL, Rd = 471.07 kN > 20.80 kN OK

Bending capacity of section


MPL,Rd = WPL,yfy/γMo
= 41.388 kNm > 9.439 kNm OK

Check for deflection Under Service Load

Service Live Load Deflection in the beam


D = 5wl4/384EI = 0.079 mm
Permissible deflection

L/250 = 7.200 mm OK

Page 2 of 5
Project title : PROPOSED CONDOMINIUM HOUSING 04/05/2023
DEVELOPMENT COMPRISING 12 BLOCKS OF 11/12/13 STOREY

DESIGN OF CONNECTION ANCHOR BOLTS

USE 4M20 HILTI ANCHOR HIT C 5.8


Moment at the connection = 9.439 kN-m
Shear at connection = 20.805 kN
Nos of tension bolts = 2 Nos
Nos of shear bolts = 2 Nos

Section width = 30 mm
spacing bolts = 190 mm
Actual tensions on bolts, Ft,Sd = 24.841 kN

Tension capacity of bolts, F t,Rd = 38.0 kN OK

Direct shear per bolt, Fv,Sd = 10.402 kN

shear resistance of anchor bolt, F v,Rd = 35 kN OK

Fv,Sd/Fv,Rd + Ft,Sd/1.4Ft,Rd < 1 = 0.764 <  1 OK

Check for Base Plate


Moment at base plate = 1.987 kN-m
Yeild strength of Mild steel = 275 N/mm2
Plate width = 25 cm

Required Elastic Modulus


M/py = 7.226 cm3

Use thickness of plate 14mm = 1.4 cm


Zx = bd /6 2
= 8.167 cm3 OK

Page 3 of 5
Project title : PROPOSED CONDOMINIUM HOUSING 04/05/2023
DEVELOPMENT COMPRISING 12 BLOCKS OF 11/12/13 STOREY

Check Connection welding

applied force = 20.80 kN


length of weld = 60.00 mm
Ultimate tensile strength of S275 steel, f u = 430.00 N/mm2
Correlation factor, βw = 0.85
Throat thickness of weld, ɑ = 6.00 mm
Effective length of weld, l-2ɑ = 48.00 mm
Partial safety factor for weld, ɼM2 = 1.25 N/mm2
Design resistance of weld, F w,RD = fvw,dɑ
fvw,d = (fu/√3)/(βwɼM2)
fvw,d = 233.66 N/mm2
Fw,RD = 1401.9 N/mm
Vw,RD = 67.29 kN OK

Page 4 of 5
Project title : PROPOSED CONDOMINIUM HOUSING 04/05/2023
DEVELOPMENT COMPRISING 12 BLOCKS OF 11/12/13 STOREY

Page 5 of 5

You might also like