South Mara Hydro Power Project: Kenya Tea Development Agency, KTDA Base MKN 29-Aug-2016
South Mara Hydro Power Project: Kenya Tea Development Agency, KTDA Base MKN 29-Aug-2016
INPUT
fcu=
25 N/mm2
fy=
460 N/mm2
2
Area of reinforcement " As " =
1005 mm
b=
1000 mm
h= 600 mm
d= 540 mm
Minimum cover to tension reinforcement " CO " = 50 mm
Maxmum bar spacing " S " = 200 mm
Bar dia " DIA " = 16 mm
" acr " =(((S/2)^2+(CO+DIA/2)^2)^(1/2)-DIA/2) as default or enter other value = 107.60 mm
"acr " is distance from the point considered to the surface of the nearest longitudinal bar
Applied service moment " Ms "= 100.0 KNm
CALCULATIONS
moduli of elasticity of concrete " Ec" = (1/2)*(20+0.2*fcu) = 12.5 KN/mm2
moduli of elasticity of steel " Es " = 200.0 KN/mm2
Modular ratio " a " = (Es/Ec) = 16.00
" r " = As/bd = 0.002
depth to neutral axis, "x" = (-a.r +((a.r)2 + 2.a.r)0.5.d = 117 mm