Svan 958 A
Svan 958 A
Svan 958 A
Features
Four-channel, 20 kHz real-time, simultaneous sound and vibration
measurements
Analyser options:
FFT analysis up to 1600 lines in 20 kHz band
Sound intensity
RT 60 reverberation time
continuous innovation
SVAN 958A
Technical Specification
Vibration Level Meter & Analyser
Standards ISO 8041:2005, ISO 10816-1
Meter Mode RMS, VDV, MTVV or Max, Peak, Peak-Peak
Simultaneous measurement in up to four channels with independent set of filters and detector constants
Analyser (option) 1/1 octave real-time analysis, 15 filters with centre frequencies from 1 Hz to 16 kHz (class 1, IEC 61260)
1/3 octave real-time analysis, 45 filters with centre frequencies from 0.8 Hz to 20 kHz (class 1, IEC 61260)
FFT analysis up to 1600 lines with Hanning, Kaiser-Bessel or Flat Top window
FFT cross spectra measurements
RPM rotation speed measurements parallel to the vibration measurement (1 ÷ 99999)
and more…
Filters Wd, Wk, Wc, Wj, Wm, Wb, Wg (ISO 2631), Wh (ISO 5349), HP1, HP3, HP10, Vel1, Vel3, Vel10,
VelMF, Dil1, Dil3, Dil10, KB (DIN 4150)
RMS & RMQ Detectors Digital true RMS & RMQ detectors with Peak detection, resolution 0.1 dB
Time constants: from 100 ms to 10 s
Accelerometer (option) SV 84 triaxial high sensitivity accelerometer for ground or building vibration measurements (1 V/g)
SV 38 low-cost triaxial accelerometers for whole-body measurements (1 V/g MEMS type)
Measurement Range Accelerometer dependent (with SV 84: 0.0005 ms-2 RMS ÷ 50 ms-2 PEAK)
Frequency Range 0.5 Hz ÷ 20 kHz; accelerometer dependent
Basic Data
Input IEPE type (channels 1, 2, 3 - LEMO 4-pin & channel 4 - TNC connector)
Dynamic Range 100 dB, 4 x 20 bits A/D converters
Frequency Range 0.5 Hz ÷ 20 kHz, sampling rate 48 kHz
Data Logger Time-history logging to internal memory or USB memory stick
Time-domain signal recording on USB memory stick (option)
Display Super contrast (10000:1) OLED 2.4” colour display (320 x 240 pixels)
Memory 32 MB non-volatile flash type, external USB memory stick (not included)
Interfaces USB 1.1 Client, USB 1.1 Host, RS 232 (option: SV 55 required)
Extended I/O - AC output (1 V Peak) or Digital Input/Output (Trigger / Pulse)
Power Supply Four AA batteries (alkaline) operation time > 10 h (6.0 V / 1.6 Ah)
Four AA rechargeable batteries (not included) operation time > 14 h (4.8 V / 2.6 Ah)
SA 17A external battery pack (option) operation time > 24 h
External power supply 6 V DC ÷ 24 V DC (1.5 W)
USB interface 500 mA HUB
Environmental Conditions Temperature from -10 oC to 50 oC
Humidity up to 90 % RH, non-condensed
Dimensions 140 x 82 x 42 mm
Weight 510 grams with batteries
each function parallel to the meter mode with USB 1.1 Host function not active and backlight off
Continuous product development and innovation are the policy of our company. Therefore, we reserve the right to change the specifications without prior notice.
DISTRIBUTOR:
SVANTEK Sp. z o. o.
ul. Strzyg³owska 81, 04-872 WARSAW, POLAND
phone/fax (+48) 22 51 88 320, (+48) 22 51 88 312
http://www.svantek.com e-mail: office@svantek.com.pl