Quick Scope: Non-Contact Vision Measuring Machine Offers High Accuracy, Real Affordability and Powerful Functionality!
Quick Scope: Non-Contact Vision Measuring Machine Offers High Accuracy, Real Affordability and Powerful Functionality!
Quick Scope: Non-Contact Vision Measuring Machine Offers High Accuracy, Real Affordability and Powerful Functionality!
QUICK SCOPE
In industry, where the need for high-accuracy non-contact measurement currently increases,
high-speed and high-accuracy vision systems are becoming the mainstream in non-contact precision
measurement.
Mitutoyo Quick Scope Series are vision measuring microscopes that anyone can easily use
to perform not only image observation and single part measurement, but also automatic multiple
part measurement.
Quick Scope powerfully supports your vision measurement applications in most diverse environments.
Software
Basic software to control Quick Scope
The vision measuring software,
QSPAK, continues to evolve.
QSPAK and various application
Traceability
software provide multifunctional Mitutoyo offers calibration services of various kinds from a
analysis, high speed image unique company that is home to nationally accredited calibration
processing, and ease of operation. laboratories in three fields - laser sources for length measurement,
end standards, and line standards. Also, as a comprehensive
manufacturer of precision instruments, Mitutoyo provides a number
Research & Development Division
of measuring instruments traceable to national standards, such as
Optical system coordinate measuring machines, optical measuring instruments, and
form measuring instruments as well as vision measuring systems.
The optical system used in Quick
Scope machine is manufactured
based on leading-edge optical
technologies that Mitutoyo has
developed over the years. This
is an ideal optical system that
provides an even and flare-free
image over the entire visual field.
Lens design and manufacture Linear Scale manufacture Iodine absorption stabilized He-Ne laser
(633nm, for length standards)
2
The Quick Scope Series can be used for measurement in various industries for such products as
molded-plastic parts, machined parts, cutting tools, medical devices and electronic components.
The vision measuring software QSPAK, which combines excellent operability with high functionality,
aids customers in meeting measurement challenges. The additional use of the application software
FORMPAK-QV can extend QSPAK capabilities to enable form assessment and analysis.
QS Series Lineup
QS-200Z QS-LZB
Drive method Focus Optical system Image detecting unit Drive method Focus Optical system Image detecting unit
Fixed/zoom lens Contrast-level
CNC all axes AF Color CCD camera Manual all axes Zoom CMOS color camera
selectable function
QS-EB
Workpiece examples
3
Drastic Improvement in Working Efficiency
Thanks to Functions Focused on Operability
4
■ Programmable power zoom
Applicable models: Zoom lens models of QS-200Z and QS-LZB
Zooming from low to high magnifications can support either observation to high-magnification measurement without changing lenses.
Additionally, the automatic light control function associated with a zooming operation and automatic correction functions, such as image displacement
and pixel calibration, is installed in these models.
■ Control box
Applicable models: QS-200Z, QS-LZB
Frequently-used operations such as illuminating, data entry, zooming, and auto-focusing* can be performed with a single touch of individual buttons
conveniently positioned on the control box.
The CNC QS system allows remote operation with a jog shuttle. The manual QS system can be operated with a single touch of a button when repeating
measurement.
* Function available only in QS and QS-L/AFB
1X 2X 4X
5
CNC Vision Measuring System
QS-200Z
QS-200Z
■ Specifications
Model QS200Z QS250Z
Zoom lens system
Order No. 359-504-9A 359-508-9A ■ Dimensions Unit: Inch (mm)
Drive method CNC
Range (X×Y×Z) Inch/mm 8”× 8”×4” (200×200×100) 8”×10”×4” (200×250×100) 18”(465) 32”(815)
Resolution/Length standard 0.5µm/Linear encoder
Image detecting unit 1/3" Color CCD camera
26”(663)
Measuring XY (2.5+6L/1000)µm
accuracy*1 Z (5+6L/1000)µm
6”(160)
Drive speed Max 80mm/s
55”(1403)
Acceleration and deceleration Max.250mm/s2
Stage glass size 11”×10” (269×261) 11”×12” (269×311)
Maximum stage loading 22lbs (10kg) 29”(740)
Contour Illumination: 12V/30W Halogen
Illumination Reflected Illumination: 12V/50W Halogen
Fiber-optic ring light: 12V/100W Halogen
Dimensions (W×D×H) Inch/mm 18”×32”×26” (465×815×663)
71”(1800) 35”(900)
Mass 169lbs (76kg)
Power consumption*2 970W at max *Shown on optional table
*1 Company standard (fixed lens system: 2.5X, zoom lens system: 2.5X at the time of zooming in) under an
installation environment of 20°C and during use of the standard lens
*2 Value in the case of selecting the color ink-jet printer (12AAC761)
■ System diagram
Objective lenses*2 QS
QV-SL0.5X QV-1X Fixed lens system Selectable Zoom lens system Control box 2
(02AKT199) (02ALA400) QS200/QS250 QS200Z/QS250Z *1 (02APW610)
QV-2.5X QV-5X Illumination Unit Joystick box
(02ALA410) (02ALA420) Color CCD camera (02ATD415)
QS controller Contour Illumination
Optional accessories (QSC-10) Surface (coaxial) illumination Foot Switch
(937179T)
Calibration chart Dedicated table Stop switch Fiber-optic ring light
(02AKN020) (02ATE760)
PC set Software
6
Manual Vision Measuring Systems
QS-LZB, QS-EB
QS-L2010ZB
■ System diagram
Objective lenses*2 Main unit Stage options
QV-SL0.5X QV-1X QS-EB QS-LZB
For model 2010
(02AKT199) (02ALA400) QS-L2010EB Selectable QS-L2010ZB
QS-L3017EB QS-L3017ZB Rotary table with fine-feed knob (A)
QV-2.5X QV-5X
QS-L4020EB QS-L4020ZB (176-305)
(02ALA410) (02ALA420)
Foot switch Stage adapter (B)
Illumination unit
Common options (937179T) (176-310)
*1
CMOS color camera Contour Illumination
Calibration chart Dedicated table Industrial-type foot switch
(02AKN020) (02ATE760) Surface illumination (12AAJ088) For model 3017/4020
Power Unit
Fiber-optic ring light
Stop switch (Option for QS-EB) Rotary table with fine-feed knob (B)
(176-306)
7
Manual Vision
Measuring Systems
QS-E2010B
■ Specifications
Model QS-L2010ZB QS-L3017ZB QS-L4020ZB QS-E2010B QS-E3017B QS-E4020B
Order No. 359-710-1A 359-711-1A 359-712-1A 359-720-1A 359-721-1A 359-722-1A
Feed mechanism Manual
Observation unit Zoom: 0.75X – 5.25X (8X in 7 steps) Interchangeable lens:, 0.5X, 1X, 2.5X, 5X
Range (X×Y×Z) Inch/mm 8"×4”×6” (200×100×150) 12"×7”x6” (300×170×150) 16"×8”×6” (400×200×150) 8"×4”×6” (200×100×150) 12"×7”×6” (300×170×150) 16"×8”×6” (400×200×150)
Resolution/Length standard 0.1µm / Linear encoder
Image detecting unit 1/2-inch color CMOS camera 3 mega-pixels
Digital zoom 1X - 2X - 4X
Measuring XY (2.5+20L/1000)µm (3+20L/1000)µm
accuracy*1 Z (5+40L/1000)µm
Stage glass size Inch/mm 10"×6” (250×150) 15"×9” (370×240) 17"×9” (440×240) 10"×6” (250×150) 15"×9” (370×240) 17"×9” (440×240)
Maximum stage loading 22lbs (10kg) 44lbs (20kg) 33lbs (15kg) 22lbs (10kg) 44lbs (20kg) 33lbs (15kg)
Contour illumination: 12V/50W halogen, Surface illumination: 12V/50W halogen
Illumination Fiber-optic ring light (optional for QS-EB): 12V/100W halogen
Dimensions*2 Main unit 25"×30”×28” (624×769×722) 27"×36”×33” (682×916×837) 30"×37”×33” (757×930×837) 25"×30”×28” (624×769×722) 27"×36”×33” (682×916×837) 30"×37”×33” (757×930×837)
(W×D×H)mm Control unit 12"×13”×4” (310×330×103)
Main unit 160lbs (72kg) 311lbs (140kg) 321lbs (146kg) 147lbs (66kg) 298lbs (134kg) 311lbs (140kg)
Mass
Power unit 11lbs (5kg) 10lbs (4.5kg)
Power consumption 160W at max
*1 Company standard (zoom magnification: 3X for QS-LZB, 2.5X for QS-EB) under an installation environment of 20°C and during use of the standard lens
*2 The width and height increase by a maximum of X-axis stroke and Z-axis stroke, respectively. The depth increases by one half of the Y-axis stroke at most.
33”(837)
8”(205) 10”(247)*
58”(1462) 62”(1577)*
10”(247)
62”(1577)
37”(945) 39” (987)*
39”(987)
29”(740)
29”(740)
71”(1800) 35”(900)
71”(1800) 35”(900)
33”(837)
8”(205) 10”(247)*
58”(1462) 62”(1577)*
10”(247)
62”(1577)
37”(945) 39” (987)*
39”(987)
29”(740)
29”(740)
Counter window
Tools window
Functions window
Video window
Graphics window
Illumination/stage
window
Measurement window
* Item names are not actually displayed, but displayed as on-line help.
9
Tools that Reduce Operation Error and Improve Repeatability
One-click tools l Patent pending (Japan) Smart tool l Patent pending (Japan)
A single click in the vicinity of a workpiece edge allows automatic The Smart tool automatically detects the clearest edge within the range
processing from tool setting to edge detection/calculation. Additionally, this enclosed with a circle, thus allowing speedy edge detection compared with
function does not need stage movement for any workpiece measurement edge alignment using the cross hairs of a microscope or profile projector.
within a screen, drastically reducing measurement time.
10
Convenient Tools Effective for Visual Measurement
Template tools
■ Extension templates ■ CAD user template function
Extension templates are provided based on four types of pattern: cross-hair; This function allows a template to be created using a form (CAD data) in
circle; rectangle; and angle. A diameter, distance, angle, and other value the Graphics window.
can freely be set by key entry in the same manner as used in comparison * To create a template, CAD data needs to be imported and exported.
measurement with a profile projector.
Smart editor
This function allows an XY-stage travel position, lens magnification, illumination condition, etc., to be separately displayed as icons or labels in the list of part
programs (auto-measurement procedure programs), thereby simplifying program editing.
11
Navigation Function Contributes to Reduction in Measurement Time
Stage navigation (QS) l Patent pending (Japan)
This stage navigation function enables pinpoint positioning when the stage needs to be moved significantly. To move the stage, click the point in the
Graphics window to which the stage is to be repositioned. Then, the stage directly moves to the point. This can suppress wasted stage motion such as
overrun or deficient run to the minimum. To accurately move the stage, click a point to move to the center of the Video window with the mouse. Then, the
stage accurately moves to the center of the Video window. The use of this function will significantly reduce the setup time needed for a part program.
This is a navigation function that concurrently uses the Learn/Repeat function for storing and reproducing a series of measuring procedures. This function
navigates the operator to the next measuring point in accordance with the measuring procedure stored. Move the stage until the red cross-hairs indicating
the next measuring point to coincide with the green cross-hairs at the center of the monitor screen. Then, the view at the next measuring point will appear
on the screen. This function also allows zero approach using the digital counter. The operator does not need to check a measuring point while looking at a
workpiece and can perform measurement while concentrating on the screen.
(1) The next measuring point is (2) As the stage approaches the next (3) When the two cross-hairs coincide
indicated with the red cross-hairs. measuring point, the red cross-hairs and the target view appears, press
and green cross-hairs get closer to the Enter button to complete the
one another. measurement.
12
Enhanced Capabilities Supporting Tasks from Operator Management to
Inspection Report Creation
Graphics window Icon editor
Measuring features and The layouts of measurement item icons,
measurement results are displayed tool icons, etc., can freely be rearranged.
in real time on the Graphics The operator can apply custom icon
window. This allows the operator configuration in which, for example,
to verify measurement points frequently-used icons are grouped on the
with visual images. Measuring first page.
features can also be selected from
graphics, thus allowing speedier
measurement. Calculation
between features is possible using
the Graphics window.
13
Optional Accessories
Application Software Lineup that Meets the Needs for Advanced Measurements
Form assessment and analysis software
l FORMPAK-QV (Optional Software)
This software can perform contour analysis and tolerancing with design values from multi-point data acquired with the Auto-trace tool, etc.
* The Auto-trace tool for the QS-L/AFB, QS-LZB, or QS-EB only functions within a screen.
Feature
• The design value of each measurement item is automatically entered.
• The stage can quickly be moved to a given point in the CAD data.
• Graphics data can be output in a specified CAD format.
14
■ Objective Lenses (QS-E model only) ■ Calibration chart
Options for fixed-lens systems • Calibration chart
This chart is used for correcting the pixel size
of image detection.
In zoom lens systems, it is also used for zoom
NEW offset calibration that corrects an optical axis
offset.
02AKN020
Magnification Working
Objective lens Order No. View field (mm)
on Monitor*1 distance (mm)
QV-SL0.5X 02AKT199 28X (20X) 9.5×7.1 (13.2×9.8) 30.5
QV-1X 02ALA400 55X (40X) 4.7×3.5 (6.6×4.9) 34
QV-2.5X 02ALA410 138X (99X) 1.9×1.4 (2.6×2.0) 34
QV-5X 02ALA420 276X (198X) 0.9×0.7 (1.3×0.9) 33.5
Applicable model: QS200, QS250, QS-EB
*1 Magnification in the case of using a 19-inch LCD monitor. Joystick box V-block with clamp
Each numeric value in parentheses indicates that for QB-EB. Order No. 02ATD415 Order No. 172-378
Applicable model QS-200Z Maximum holding diameter:
0.984” (25 mm)
Center height from mounting
face: 38 to 48mm
5” x 4” x 2”
Dimensions (117 (H) × 90 (W) × 45 (D)mm)
Mass 2lb (0.8kg)
Rotary table with fine-feed knob (A) Rotary table with fine-feed knob (B) Applicable model QS-LZB, QS-EB
Order No. 176-305 Order No. 176-306 * Used in combination with stage adapter B (176-310) or
rotary table A (176-305).
11” x 11” x 0.945” 13” x 13” x 0.905”
(280 (W) ×280 (D) × 24 (H)mm) (342 (W) × 342 (D) × 23 (H)mm)
Dimensions Table-top surface Dimensions Table-top surface
No reading scale of 360° No reading scale of 360°
rotation angle rotation angle
Mass 12lb (5.5kg) Mass 14lb (6.5kg)
Stage-glass Stage-glass Dedicated table
effective diameter 7”(178mm) effective diameter 9” (235mm)
Applicable model QS-LZB, QS-EB Applicable model QS-LZB, QS-EB Order No. 02ATE760
Dimensions 71” x 35” x 29”
NOTE: V-block with clamp, swivel center support, and holder NOTE: V-block with clamp, swivel center support, and holder
with clamp can be secured on the table. with clamp can be secured on the table. (1800 (W) × 900 (D) × 740 (H)mm)
Mass 132lb (60kg)
342 Applicable model QS, QS-200Z, QS-LZB, QS-EB
ø188 (stage-glass outside diameter) 220
280
Clamp screw (2 pieces) ø241 (Table inside diameter) Clamp screw (2 pieces) Swivel center support
30 220
31 2-ø7 hole, ø4 countersunk, Order No. 172-197
depth 4
29˚ 37˚
70 Variable inclined posture within
±10°, minimum reading of
120 angle: 1°
24
2-M6
(Table inside diameter)
˚
220
342
282
ø240
Maximum possible holding
(103.945)
(96.361)
dimensions: ø80×140mm in
ø50
Rotating knob
Foot switch 10° inclined posture
58
(0.7) 9.5 13
4-
ø238 (stage-glass effective diameter) Rotating knob Applicable model QS, QS-L/AFB, QS-LZB Applicable model QS-LZB, QS-EB
ø28
22.5
13
Rotary table with fine-feed knob (A) Fiber-optic ring light unit Industrial-type foot switch Holder with clamp
Order No. 176-304 / B: 176-310 Order No. 359-643* Order No. 12AAJ088
3” x 9” x 5” Order No. 176-107
Dimensions 2” x 13” x1” Dimensions Applicable model QS-L/AFB, QS-LZB, QS-EB Maximum length 1.378” (35mm)
(50 (W) × 340 (D) × 15 (H)mm) (76 (W) × 235 (D) × 120 (H)mm)
1 piece NOTE: 280 (D) mm for adapter B Overall length 59” (1500mm) of clamp
Mass 3lb (1.5kg) / B: 3lb (1.2kg) Applicable model QS-EB 2” x 6” x 1.496”
Dimensions (62 (H) × 152 (W) × 38 (D)mm)
Applicable model QS-LZB, QS-EB * Combined use of external light source control cable Mass 1lb (0.4kg)
(12AAD128) is required.
NOTE: 2 pieces per set * Suffix code according to AC line voltage: C for 110V AC, A Applicable model QS-LZB, QS-EB
for 120V AC, D for 120V AC, E for 240V AC, no suffix for
100V AC * Used in combination with stage adapter B (176-310) or
rotary table A (176-305).
15
Coordinate Measuring Machines
Vision Measuring Systems
Form Measurement
Optical Measuring
One
Sensor Number to Serve You Better
Systems
1-888-MITUTOYO (1-888-648-8869)
Test Equipment and
Seismometers
Aurora, Illinois
Digital Scale and DRO Systems
(Corporate Headquarters)
SmallWestford, Massachusetts
Tool Instruments and
Data Huntersville,
Management North Carolina
Note: All information regarding our products, and in particular the illustrations, drawings, dimensional and performance data Mason, Ohio
contained in this printed matter as well as other technical data are to be regarded as approximate average values. We therefore
reserve the right to make changes to the corresponding designs. The stated standards, similar technical regulations, descriptions
Plymouth, Michigan
and illustrations of the products were valid at the time of printing. In addition, the latest applicable version of our General Trading City of Industry, California
Conditions will apply. Only quotations submitted by ourselves may be regarded as definitive.
Mitutoyo products are subject to US Export Administration Regulations (EAR). Re-export or relocation of our products may require
prior approval by an appropriate governing authority.
© 2011 Mitutoyo America Corporation, Aurora IL 0111-05 Printed in USA, March 2011 Precision is our Profession