Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Installation External Accessories: Plug-In Mccbs Terminal Covers

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

912

Circuit Breakers > TemBreakPRO MCCBs > XM30PB Accessories > Installation External Accessories

Installation External Accessories


Plug-in MCCBs Terminal Covers
Allows an MCCBs line side to be plugged onto vertically Provides front, side and internal isolation between poles in the
arranged 60 mm 3 phase busbar MCCB power terminal area.
MCCBs

Item Description Catalogue No. Item Description Catalogue No.

TemPlug Vertical 3P Type XM30PB AF UPX330PB Front Connect Terminal Cover T1CF033SLNG
XM30PB AF (2 pcs)

Tunnel Clamp Terminals


Allows cable to be terminated directly to the MCCB and
clamped for good connectivity.

Item Description Catalogue No.

XM30PB LineSide Screw XM30TSC


Terminal Cover

Item Description Catalogue No.

Tunnel Terminals XM30PB AF TXBD0009A


913

Circuit Breakers > TemBreakPRO MCCBs > ZS125_TF

ZS125_TF
Earth Leakage Circuit Breaker

MCCBs
✔ Earth leakage protection ELCB for Power distribution General
or motor start applications
Thermal Magnetic CB with Residual
✔ Current limiting, lowers fault let through energy Trip Unit Protection Type
Current trip (ELCB)

✔ Direct opening main contact / toggle mechanism Trip Unit Ratings 20, 32, 50, 63, 100, 125 A

✔ Complies to AS / NZ 60947-2, IEC 60947-2, AS / NZS


Number of Poles 3 or 4
2081 and CE

✔ Panel mount standard, with other mounting options Switching Poles 3P or 4P (Unswitched N option)

✔ Full range of accessories for application flexibility


Short Circuit
✔ 3 or 4 pole ELCBs have switched poles, an
unswitched N pole is optional Short-Circuit Fault
65 kA @ 415 V AC
Interruption Capacity (Icu)
✔ Suits XAP chassis, with panelboard options

✔ Compact 155 mm H, 68 mm D, 30 mm pole centres


Voltage
✔ Fault interruption rating; 65 kA Icu @ 415 V AC Utilisation Voltages 240 V AC to 550 V AC, 50 / 60 Hz

✔ Utilisation voltage ratings from 160 to 525 / 550 V AC


Earth Leakage settings and functions
✔ Thermal magnetic trip unit: adj. thermal / fixed mag.
I∆N (A) setting selection 30 mA, 100 mA, 300 mA, 0.5 A, 1 A, 3 A
✔ ELCB detail: 30mA to 3A, trip time selection, type A
INST, 60 ms, 200 ms, 400 ms, 700 ms,
✔ 30mA setting; fixed trip time for personnel safety ∆t (ms) setting selection
NT
✔ Remote trip function std, cause of trip module option
Testing Grey test button
✔ Trip units; 20, 32, 50, 63, 100, 125 A
EL Trip Indication Pop-out yellow, EL trip indication

Accessories and Connections


Accepts most standard MCCB accessories
Options
Chassis, mounting and connection options
914

Circuit Breakers > TemBreakPRO MCCBs > ZS125_TF

Quick Reference Dimensions – Front Connect


MCCBs
915

Circuit Breakers > TemBreakPRO MCCBs > ZS125_TF

125 A Frame 3 Pole 65 kA TM (Thermal Magnetic ELCB)


In Ir, Adjustable Im, Fixed Icu, 400 / 415 V Poles Catalogue No.
(A @ 50 °C) (A) (A) (kA)

20 12.5 - 20 240 65 3 ZS125M320TF


32 20 - 32 384 65 3 ZS125M332TF

50 32 - 50 600 65 3 ZS125M350TF

63 40 - 63 756 65 3 ZS125M363TF

MCCBs
100 63 - 100 1200 65 3 ZS125M3100TF

125 80 - 125 1250 65 3 ZS125M3125TF

125 A Frame 4 Pole 65 kA TM (Thermal Magnetic ELCB)


In Ir, Adjustable Im, Fixed Icu, 400 / 415 V Poles Catalogue No.
(A @ 50 °C) (A) (A) (kA)

20 12.5 - 20 240 65 4 ZS125M420TF


32 20 - 32 384 65 4 ZS125M432TF

50 32 - 50 600 65 4 ZS125M450TF

63 40 - 63 756 65 4 ZS125M463TF

100 63 - 100 1200 65 4 ZS125M4100TF

125 80 - 125 1250 65 4 ZS125M4125TF

125 A Frame 4 Pole 65 kA TM (Thermal Magnetic ELCB - Unswitched


Neutral)
In Ir, Adjustable Im, Fixed Icu, 400 / 415 V Poles Catalogue No.
(A @ 50 °C) (A) (A) (kA)

20 12.5 - 20 240 65 4 ZS125M420TFSN


32 20 - 32 384 65 4 ZS125M432TFSN

50 32 - 50 600 65 4 ZS125M450TFSN

63 40 - 63 756 65 4 ZS125M463TFSN

100 63 - 100 1200 65 4 ZS125M4100TFSN

125 80 - 125 1250 65 4 ZS125M4125TFSN


916

Circuit Breakers > TemBreakPRO MCCBs > ZS125_TF

Ratings Environmental
Vibration Frequency, Operational
Component Type Earth Leakage CB 16.7 Hz
(Max.)

Selectivity Category A Vibration Acceleration (Max.) 19 m/s²

Number of Poles 3/4 Vibration Duration (Max.) 12 min

Altitude, Operating
Switching Poles 3P + N / 3P 2000 m
(No Derating)
MCCBs

Frame Size 125 AF Storage Temperature -10 to +70 min/max °C

20 / 32 / 50 / 63 / 100
Trip Unit Rating Operating Temperature -5 to +70 min/max °C
/ 125 A

In, Rated Current (A) Relative Humidity, Max 85 %RH

Contact NHP
Connection
Ue, Rated Operational Voltage,
525 V AC
AC, max Cable Cross Section 1.5 - 50 mm² (Min - Max)

Ui, Rated Insulation Voltage 525 V (rms) Front Connection


Extension Bar (Option)
Uimp, Impulse Withstand Voltage 8 kV Cable Tunnel Clamp
Connection Mode
(Option)
Supply Voltage Type AC Rear Connection (Option)
Plug-in UPX (Option)
Rated Frequency 50 / 60 Hz
Terminal Type Bolt-Terminal

Pollution Degree 3
Connection Torque 4.9 - 6.9 Nm

Trip Unit Rating (A) - Power Loss Per Pole (W)

Contact NHP Installation Types


Dielectric Strength 1890 V AC Suitable for Panel Mounting Yes

DIN rail mounting


Yes
with optional adapter
Standards Suitable for mounting on chassis
XAP Chassis
XCP Chassis
IEC 60947-2 Suitable for Distribution
Standards Compliance Yes
AS - NZS 2081 Switchboard or MCC

RCM (Regulatory Compliance Mark) Compliant Withdrawable No

CE Mark Compliant Plug-in PM Base No

Shipping Approvals Contact NHP Plug-in UPX Type No

Contact NHP for standards compliance and approvals not


Mounting -
listed here
917

Circuit Breakers > TemBreakPRO MCCBs > ZS125_TF

Physical Trip Unit


Height 155 mm Over Current Protection Function Yes

Thermal Magnetic
3P 90 mm
CB with Type AC
Width Trip Unit Protection Type
Residual Current Trip
4P 120 mm (ELCB)

Depth (less toggle) 68 mm Rated Temperature 50 °C

MCCBs
Depth (toggle included) 92 mm

3P 1.1 kg
General Accessories
Weight
4P 1.4 kg Auxiliary Switches Yes

Electrical Life 10000 cycles Alarm Switch Yes

Mechanical Life 30000 cycles Shunt Trip Yes

Under Voltage Trip Yes

Handle Operators Yes


Short-Circuit Capacity
kA Rating Motor Operator Yes

MCCB Type
Mechanical Interlock No
Voltage M
Mechanical Interlock -
220 / 240 V AC 85 No
rear walking beam
Icu (Ultimate Breaking Capacity)

380 / 400 V AC 65
Locking Devices Yes
415 V AC 65
Terminal Covers Yes
440 V AC 50
Based On AS/NZS 60947.2 and IEC 60947-2

690 V AC - Interpole Barriers Yes


1000 V AC -
External Panel Display No
1100 V AC -

125 V DC -
250 DC -

220 / 240 V AC 85
Ics (Service Breaking Capacity)

380 / 400 V AC 36

415 V AC 33

440V AC 25

690 V AC -

1000 V AC -

1100 V AC -

125 V DC -
250 V DC -
918

Circuit Breakers > TemBreakPRO MCCBs > ZS125_TF

ELCB Operating Characteristics –


ZS Earth Leakage Circuit Breakers ZS125 or ZS250
showing remote trip
leads RT1 and RT2

Circuit Breakers with Integral Residual Current


Protection (CBRs) are the ultimate safeguards
against the hazards of earth leakage.
MCCBs

The TemBreak PRO, ZS ELCB range is available in 2 frame si-

TBPro(ELCB-ZS)_dOPCH-S01
zes, 125 A and 250 A. Interrupting capacities of 50 kA and 65 kA
are offered in 3 and 4 poles versions with adjustable thermal and
fixed magnetic protection characteristics. Model sizes range from
20 A to 250 A versions.

ZS 125 A and 250 A Models Earth Leakage Features

■ Switching utilisation up to 550 V AC


The ZS earth leakage MCCB from Terasaki offers machine or
personnel protection within a standard 125 A, 160 / 250 A MCCB ■ Suitable for use at 40 / 50 / 60 Hz (except 3 A @ 40 Hz)
frame size.
■ 3 or 4 pole types
The full functionality of a standard thermal-magnetic overload /
■ Yellow ground fault TRIP indication flag
short circuit protection MCCB is maintained.
■ Grey TEST button
Standard Features ■ Green ’Power ON’ LED
■ Thermal / Magnetic MCCB
■ Adjustable thermal characteristic dial setting from
■ 125 A or 250 A frame 63 - 100 % of I R

■ Trip unit ratings: 12.5 A – 125 A (125 AF), 100 A – 250 A ■ Adjustable earth leakage ranges: 30 mA, 100 mA, 300 mA,
(250 AF). Fixed magnetic setting 500 mA, 1 A, 3 A

■ 65 kA fault interruption rating @ 415 AC ■ Trip time selection: 0, 60, 200, 400, 700 mS or NT (No Trip)

■ Built-in dielectric disconnection test plug ■ 30 mS time setting defaults to a less than 300mS trip time
as per AS/NZS standard requirements.
■ Harmonics inhibition
■ Type “A” - suitable for AC and residual pulsating DC
■ Remote trip function via external wire dry contact closure currents
(standard on ZS125GJ / ZS250GJ) 1)

Options and Fitting

■ T2M1166CBA: Trip control module with: Pre-trip alarm


and Cause of trip output, remote trip function

■ Accepts T2AX / T2AL aux/alarm switches

Notes ■ Fits to XAP, XAB, XCP chassis


1) The remote trip function includes two 700 mm wires (RT1 and RT2) coming from
the side of the ELCB. The ELCB will trip via dry contact closure of the two wires ■ Seal available for sealing the E / L dial setting area of the
using a pushbutton or relay etc. The tripping of the ELCB is performed by the earth
leakage module trip function being activated, which trips the ZS ELCB. Where
MCCB. E.g. @ 30 mA
remote trip and the associiated wires are not required, the wires can be either coiled
safety for future use, or cut off, by lifting the ELCB cover and cutting the wires where ■ Captive padlock attachment that includes a dial
they are connected to the EL electronic module. sealing feature
919

Circuit Breakers > TemBreakPRO MCCBs > ZS125_TF

ELCB Operating Characteristics –


ZS125 / ZS250 Earth Leakage CB

Voltage presence LED

Trip indicator. The yellow


button pops up to the indicate
tripping due to residual current.
When the breaker is reset, the

MCCBs
button will retract

Type A. Tripping is ensured


for residual sinusoidal AC in
the presence of residual
pulsating DC

Test button. Press the button


to test the residual current
detection and tripping system

Adjustable time delay for


residual current protection.
Setting include zero and
non-trip (NT)

Adjustable residual current


tripping thresholds. 30 mA,
100 mA, 300 mA, 500 mA,
1000 mA and 3000 mA

TBPro(ELCB-ZS)_dOPCH-S02

Adjustable overload protection


IR can be set between 63% and
100% of IN

Switched or unswitched Neutral


pole types stocked

Dielectric test device. Remove


the plug to allow dielectric
testing to be done with the
ELCB closed (ON)
920

Circuit Breakers > TemBreakPRO MCCBs > ZS125_TF

Remote trip feature: standard for


125 / 250 A ELCBs

Remote Trip operation

The RT (2-wire) standard feature on ZS 125 / 250 ELCBs is an


easy to use means of remote tripping the ELCB, via dry contact
closure, of the 2 wires. The RT feature uses the EL module
in the ZS ELCB to trip the ELCB.
MCCBs

Connecting Diagram

RT1

RT2

Remote Trip
Terminal No. RT1 RT2

Note
TBPro(ELCB-ZS)_dOPCH-S03

The RT feature is not considered a “test” of the ZS ELCB, as the RT does not test the
ELCBs internal ZCTs. Only by pressing the ELCBs “TEST” button is a complete test
performed, as this tests the full current path within the ELCB.

Refer next page for the option of using an external pushbutton and resistor to perform a
remote test of a ZS ELCB.

If the remote trip feature is not required, the user can leave the wires unconnected and
coiled for possible future use, or they can be cut off if the feature will never be required.
921

Circuit Breakers > TemBreakPRO MCCBs > ZS125_TF

MCCB Operating Characteristics –


Thermal Magnetic and Electronic

TCU - Trip Control Unit

T2M1166CBA
Earth Leakage Pre Trip Alarm with cause of trip output, and
Remote Trip

MCCBs
The optional TCU attaches to the right side of a ZS ELCB.
Power to the TCU unit is supplied by connecting directly to the
EL MCCB line side terminals.

TCU Features

■ Can be retrofitted to older and newer ZS ELCBs on-site by


qualified personel.

■ A Normally Open (N/O) maintained contact (2 A – 250 V


AC) switches as a result of an earth fault, which also acts
as a Pre Trip Alarm.

■ The pre-trip alarm N/O contact activates at a selectable


50 % or 70 % of the selectable earth leakage setting.

■ A red LED on the front of the EL MCCB, also indicates an


earth leakage within the system.

TBPro(ELCB-ZS)_dOPCH-S04
■ A tamper-free transparent cover is available for sealing the
setting area of the TCU.

■ Remote trip facility (RT), to allow remote tripping of the EL


MCCB.

■ Down Voltage Trip function which is similar to a UVT. Above


Unlike a UVT, the ELCB can be switched back to ON Trip control unit
T2M1166CBA
without power restoration.

Below
Close-up of the TCU setting facia

Notes
3 and 4 pole ZS ELCBs are same width as standard MCCBs. If the optional TCU module is
added, the overall width of the ELCB + TCU combination is increased by 25 mm.

For outline dimensions of MCCBs with a TCU fitted, refer to the previous
ordering pages.
922

Circuit Breakers > TemBreakPRO MCCBs > ZS125_TF

ELCB Operating Characteristics –


ZS125 / ZS250 Earth Leakage CB
MCCBs

TBPro(ELCB-ZS)_dOPCH-S05
IΔn is the adjustable tripping The dial 'Δt (ms)' is a time delay IR is the adjustable tripping IR is the tripping threshold
threshold for residual current which is introduced to the threshold for overload for short-circuit protection.
(earth leakage) protection. It residual current (earth leakage) protection. It can be set It is fixed at the values
can be set between 30 mA protection characteristic. between 0.63 and 1.0 times shown below.
and 3 A. Available settings Available settings are shown In ratings are shown below.
are shown below. below. The dial can also be set
to INST (max. actual tripping
time is 40 ms) or NT (No Trip -
tripping time = ∞). The
maximum breaking time at each
setting is shown in brackets in
the table below. Note that when
IΔn (A) is set at 30 mA, Δt (ms)
defaults to tripping within
300 ms or less.

Model IΔn (A) Δt (ms) In (A) Ii

0 (40), 60 (195), 200 (365), 400 (620), 700


ZS125 0.3, 0.1, 0.3, 0.5, 1, 3 20, 32, 50, 63, 100 12 x In (+/- 20 %)
(950), NT (∞ )

0 (40), 60 (195), 200 (365), 400 (620), 700


ZS125 0.3, 0.1, 0.3, 0.5, 1, 3 125 10 x In (+/- 20 %)
(950), NT ( ∞)

0 (40), 60 (195), 200 (365), 400 (620), 700


ZS250 0.3, 0.1, 0.3, 0.5, 1, 3 160 13 x In (+/- 20 %)
(950), NT ( ∞)

0 (40), 60 (195), 200 (365), 400 (620), 700


ZS250 0.3, 0.1, 0.3, 0.5, 1, 3 250 10 x In (+/- 20 %)
(950), NT (∞ )
923

Circuit Breakers > TemBreakPRO MCCBs > ZS125_TF

Time Current Characteristic Curve, ZS125M, Thermal Magnetic ELCB

4
3 f-f-

2 f--f--

MCCBs
1 f-f-
50
l
f-f-

40
l
f-f-

30 f-f-

�\
20

10 f-f- �\ \
8
\ \
6 ...
"
5 50 -125A(max)

'
\ I\ '

,,
4
3 \ '\. I
\' .J

\
2

1 �
.....

'
50
40 f- 50 - 125A(minl -f. -� '-

"'
20 - 32A(max)
30
\ I'\..
\. /
20
I/
\
.,
10
8 1,
·a. I\.
'
6

"
I\,
5 I ' "
� 4
20 - 32A(minl I\ \.
3
\ � \
2
l'\r\. 1,

'
1
0.8
0.6

:,
0.5
0.4
0.3
0.2

-----
0.1
0.08

......
0.06
0.05 I
0.04
0.03 !?.� f-�

I
0.02
I
I
0.01
0.008
0.006
0.005 � § � �
g

Percentage of Rated Current, In I


924

Circuit Breakers > TemBreakPRO MCCBs > ZS125_TF

Time Current Characteristic Curve, ZS125M/ZS250M,


Thermal Magnetic ELCB
Residual Current Characteristic
MCCBs
925

Circuit Breakers > TemBreakPRO MCCBs > ZS125_TF

Let-Through Peak Current Characteristics, ZS125M, Thermal Magnetic



MCCBs
   
926

Circuit Breakers > TemBreakPRO MCCBs > ZS125_TF

Let-Through Energy I²t Curve, ZS125M, Thermal Magnetic


MCCBs

  
927

Circuit Breakers > TemBreakPRO MCCBs > ZS125_TF

Dimensions ZS125M (mm)


Front connected With extension bars
(optional)

MCCBs
Rear Connected

48
Panel cutout dimensions shown give an
allowance of 1.0mm or more around the
handle escutcheon.

Front Connected With Motor Operator


3P 4P Preparation of conductor Drilling plan Panel hinge position (hatching area)
bottom view
ø9
Interpole barrier
8.5(max.)

(removable) Mounting hole 154 3P 4P


Front panel t2
24
HL HL M8 screw HL HL
47

17(max.) HL
max.t5
8.5
17

Operating knob
154±1

CL
134
155

132

100 100
150 150
45 8 M4x0.7 200 200
60 M4x0.7
10

14.5 21.5 Connector plug Mounting screw 30 30


90 61 Tapped hole
90 45 106
30 30 30 5.5 164.5
45 75 28(max.)

Rear Connected With Motor Operator


90 Drilling plan Panel cutout
86 (Front view)
HL
154
Mounting plate 3P 4P 4P
Front panel t2
103.5

Operating knob (max. t3.2) 3P


HL HL
HL
5

R1
61
148

CL CL CL
155
134

132
134

15 Conductor
155

overlap max.
16

45
Pad lock ø8.5 15 M4X0.7
15 30 30 30 30 30 ø18 90
61 52 Mounting
Connector plug Stud can be screw 60 30 30 30 M4X0.7
45 106 102 Tapped hole Panel cutout dimensions shown
5.5 164.5 give an allowance of 1.5mm
around the handle escutcheon.
28(max.)