W4gled W4pled
W4gled W4pled
W4gled W4pled
Notes Type
DIMENSIONAL DATA
Button Style
Photocontrol
Window
ORDERING INFORMATION Italicized and Blue INDICATES OPTIONS ONLY AVAILABLE WITH W4GLED Example: W4GLED 30C1000 40K T3S MVOLT SPD PR7 BZSDP
Notes
1 Not available with 10C1000
2 Not available with 480V
3 Available Only with W4G
4 Not available with 10C1000
5 Available with T3M only
6 Not Available 30C Performance Package. Not Available 347, 480 Voltage. Not Available PE, P3, P7 Control.
7 Not available with LVG option. Casting is pre-drilled for guard. Vandal guard ships separately.
8 Not available with LWG option. Casting is pre-drilled for guard. Vandal guard ships separately.
9 Only available with PR3 control option (ships separately)
10 Not available with PCB option
OPTIONS MATRIX
Voltage Options by LED Package SELECTED OPTION
Parameters
10Cxxxx 20Cxxxx 30Cxxxx AO PCB PR3 PR7 SF DF TPS NOM ELSW ELCW LWG LVG
10Cxxxx N Y W4G W4G Y Y Y T3M W4GM W4GM Y W4G
LED Package 20Cxxxx Y Y W4G W4G Y Y Y T3M W4GM W4GM Y W4G
30Cxxxx Y Y W4G W4G Y Y Y T3M N N Y W4G
MVOLT Y Y Y Y Y W4G W4G Y N Y T3M W4GM W4GM Y W4G
120 Y Y Y Y Y W4G W4G Y Y Y T3M W4GM W4GM Y W4G
208 Y Y Y Y Y W4G W4G Y Y Y T3M W4GM W4GM Y W4G
Voltage 240 Y Y Y Y Y W4G W4G Y Y Y T3M W4GM W4GM Y W4G
277 Y Y Y Y Y W4G W4G Y Y Y T3M W4GM W4GM Y W4G
347 N Y Y Y Y W4G W4G Y Y Y T3M N N Y W4G
480 N Y Y Y N W4G W4G Y Y Y T3M N N Y W4G
T3M Y Y W4G W4G Y Y Y T3M W4GM W4GM Y W4G
Optic
T3S W4G Y W4G W4G Y Y Y N N N Y W4G
AO Y W4G W4G Y Y Y T3M W4GM W4GM Y W4G
PCB Y N N Y N Y T3M N N Y W4G
Controls
PR3 W4G N N W4G W4G W4G W4GM N N W4G W4G
PR7 W4G N N W4G W4G W4G W4GM N N W4G W4G
SF Y Y W4G W4G N Y T3M W4GM W4GM Y W4G
DF Y Y W4G W4G N Y T3M W4GM W4GM Y W4G
TPS Y Y W4G W4G Y Y T3M W4GM W4GM Y W4G
NOM Y W4G W4G W4G Y Y Y W4GM W4GM N W4G
Options
ELSW Y N N N W4G W4G W4G T3M W4G W4G
ELCW Y N N N W4G W4G W4G T3M W4G W4G
LWG Y Y Y Y Y Y Y T3M W4GM W4GM N
LVG W4G W4G W4G W4G W4G W4G W4G W4GM W4GM W4GM N
LEGEND
N = Not available with W4GLED & W4PLED
Y = Valid combination with W4GLED & W4PLED
T3M = Only available on W4GLED & W4PLED with T3M distribution
W4G = Only available with W4GLED
W4GM = Only available on W4GLED with T3M distribution
OPERATIONAL DATA
Operating Characteristics
30K (3000K, 70 CRI) 40K (4000K, 70 CRI) 50K (5000K, 70 CRI)
Series LED Package System Watts Distribution Tyoe
Lumens LPW B U G Lumens LPW B U G Lumens LPW B U G
10C1000 39 3140 81 0 3 3 3377 87 0 3 3 3398 87 0 3 3
W4G 20C1000 72 6495 90 1 3 4 6983 97 1 3 4 7027 98 1 3 4
30C1000 104 7789 75 1 3 4 8375 81 1 3 5 8427 81 1 3 5
T3M
10C700 26 2030 78 0 3 2 2183 84 0 3 2 2197 85 0 3 2
W4P 20C700 45 3912 87 0 3 3 4207 93 1 3 3 4233 94 1 3 3
30C700 67 4813 72 1 3 3 5176 77 1 3 4 5208 78 1 3 4
10C1000 28 3206 115 0 3 2 3485 124 0 3 2 3485 124 0 3 2
W4G 20C1000 57 6507 114 1 3 2 7073 124 1 3 3 7073 124 1 3 3
30C1000 77 8477 110 1 3 3 9214 120 1 3 3 9214 120 1 3 3
T3S
10C700 27 2709 100 0 3 2 2944 109 0 3 3 2944 109 0 3 3
W4P 20C700 38 3299 87 0 3 3 4017 106 1 3 3 4017 106 1 3 3
30C700 49 4203 86 1 3 3 5173 106 1 3 3 5173 106 1 3 3
PHOTOMETRIC DISTRIBUTIONS
T3M T3S
Glass
Polycarbonate
OPERATIONAL DATA
Lumen Maintenance
Data references the extrapolated performance projections for the platforms noted in a 25o C To calculate LLF, use the lumen maintenance factor that corresponds to the desired number of
ambient, based on 10,000 hours of LED testing (tested per IESNA LM-80-08 and projected per operating hours below. For other lumen maintenance values, contact factory.
IESNA TM-21-11).