Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

FlowCERT Pulsar Open Chanel Flow Meter

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

FlowCERT

Open Channel Flow Meter

The FlowCERT open channel flow meter provides comprehensive flow monitoring with data logging and
control functions for a complete range of flumes and weirs. It is compatible with a range of sensors in
order to create a flow metering system to suit your application.

Technical Specification:
PHYSICAL:
Sensor body dimensions: 235 x 184 x 120mm (9.25 x 7.24 x 4.72in)
Sensor body weight: Nominal 1kg (2.2lbs)
Enclosure material/description: Polycarbonate, flame resistant to UL91
Cable entry detail: 10 cable entry knock outs, 1 x M16, 5 x M20 underside, 4 x 18mm dia (PG11) at rear
Transducer cable extensions: 2-core screened
Maximum separation: Up to 1000m (3280ft)
ENVIRONMENTAL:
Enclosure protection: IP65 / NEMA 4X
Max. and min. temperature (electronics): -20°C to +50°C (-4°F to +120°F)
APPROVALS:
CE approval: Listed in the Certificate of Conformity within the manual
Flammable atmosphere approval: Safe area: compatible with approved dB transducers
PERFORMANCE:
Accuracy/Repeability: Dependent on application and sensor used. See sensor specification.
Resolution: Dependent on application and sensor used. See sensor specification.
Min. & max. range: 0 - 15m (49ft). Dependent on sensor used.
Rate response: Fully adjustable
Echo processing: DATEM (Digital Adaptive Tracking of Echo Movement)
OUTPUTS:
Analogue outputs: 2x Isolated (floating) output (to 150V) of 4-20mA or 0-20mA into 500Ω (user programmable and
adjustable) 1μa resolution
Digital output: Full Duplex RS232
Volt free contacts, number & rating: 5 form “C” (SPDT) rated at 5A at 115V/240Vac
Display: 6 digits plus 12 charact text, plus bargraph with direction indicators, remote communicator identifier and
program/run/test mode indicators
INPUTS:
Analogue inputs: Isolated (floating) input (to 150V) of 4-20mA or 0-20mA source or sink, open circuit voltage (source) 33V,
22V at 4mA, 14V at 20mA (user programmable and adjustable) 0.1% resolution
Velocity input: Via RS485 digital communications interface
PROGRAMMING:
On-board programming By integral keypad
PC programming: Via RS232
Programming security: Via passcode (user selectable and adjustable)
Programmed data integrity: Via non-volatile RAM, plus backup
SUPPLY:
Power supply: 115Vac +5% / -10% 50/60Hz, 230Vac +5% / -10% 50/60Hz, 22-28Vdc, 10W maximum power
(typically 6W)
Fuses: 100mA at 230Vac, 200mA at 115Vac

Pulsar Process Pulsar Process


Measurement Ltd. Measurement Inc.
Pulsar Process Measurement Ltd. operates a policy of
constant development and improvement and reserves the
Malvern, WR14 1JJ, UK Niceville, FL 32578, USA
right to amend technical details as necessary. Tel: +44 (0) 1684 891371 Tel: +1 850 279 4882
Email: info@pulsar-pm.com Email: info.usa@pulsar-pm.com
Literature No. FP-D-0717
Copyright © 2017 Pulsar Process Measurement Ltd. www.pulsar-pm.com