Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

DS JetLink1102 V1.0

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

JETLINK

Industrial Fieldbus Gateway

JetLink 1102 Modbus RTU/TCP to Ethernet/IP


Feature:
• 2-port 10/100 RJ-45 for Modbus TCP Master
• 2-port 10/100 RJ-45 for Ethernet/IP Adapter
• 2-port DB9 for Modbus RTU
• Modbus function support 1,2,3,4,5,6,15,16,23
• EDS file ready for device and network integration
• Max. 64 Connections for Modbus RTU/TCP
• Dual Image
• Support MicroSD Card Configuration backup and
restore
• Wide Temperature design -10~60oC
• Redundant Power Input DC 12-48V
• IP 30 Metal Case Protection

Factory

Overview
JetLink 1102 is an Industrial Fieldbus gateway providing seamless communication between
Fieldbus and Industrial Ethernet and supports different protocol devices and integrates new and
existing Modbus RTU/TCP devices to the EtherNet/IP network.
To collect data and exchange data between Modbus RTU/TCP to EtherNet/IP. JetLink 1102 is a
simple and cost-effective way to bring the advantages of fast data transmissions between
different devices.

JetLink

Korenix Technology Datasheet V1.0 7/3/2018 www.korenix.com 1


Dimension

Interface

Korenix Technology www.korenix.com 2


Specification
Interface
Ethernet Port – RJ-45 2 x 10/100 EtherNet/IP
2 x 10/100 Modbus TCP
Serial Port 2 x Serial Ports
RS-232: TxD, RxD, CTS, RTS, DCD, RI, GND
RS-422: TxD+, TxD-, RxD+, RxD-, GND
RS-485: Data+, Data-, GND
Connectors 10/100Base-TX: RJ-45
Terminal block: 4-Pin for redundant power input; 2-Pin for alarm relay output.
Cables RJ-45 Connector: 4 pairs of Cat-5e UTP/STP cable (Maximum link distance is 100meters.)
DB9 male

Diagnostic LEDs System:


- 2 x Power: On (Power On), Off (Power Off)
- 1 x Status: On (Loop), Off (Non-Loop)
Protocol Status:
- 1 x EI: On (Active), Off (Non-link)
- 1 x MS: On (Active), Off (Non-link)
- 2 x TX: On (Active), Off (Non-link)
- 2 x RX: On (Active), Off (Non-link)
Power Connector Removable Terminal Block: 12-48V power Input
Software Feature
Modbus RTU/TCP Mode: Master
Functions Support: 1, 2, 3, 4, 5, 6, 15, 16, 23
Max. 64 connections
EtherNet/IP Class Adapter
Max. 32 explicit messaging Connections, 5 implicit messaging
Max. 496 bytes I/O Data Size Input
Power Requirement
Power Removable Terminal Block: 12-48V power Input
Power input with polarity reverse correction and over current protection.
Power Consumption 5 Watts / DC 24V
Mechanical

Enclosure Protection Ingress Protection code – 30


Case Slim metal case
Mounting DIN Rail
Dimension 95(D) X 42(W)x 140(H) mm (Without Din-rail kit)
Weight 0.6 kg without package

Environmental
Operating Temperature -10℃~60℃
Operating Humidity 10% ~ 95% non-condensing
Storage Temperature -40℃~85℃
Storage Humidity 10%~ 95% non-condensing
Approvals
EMI CE/EN 55032 class A, FCC Class A, EN 61000-3-2 :2014, EN 61000-3-3, EN 61000-6-4
EMS CE/ EN 55024, EN 61000-6-2, IEC 61000-4-2,IEC 61000-4-3, IEC 61000-4-4,
IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11
Shock IEC60068-2-27 (Compliance)
Vibration IEC60068-2-6 (Compliance)
Free Fall IEC60068-2-32 (Compliance)
Warranty 2 years
Ordering Information
JetLink 1102 Industrial Modbus RTU/TCP to EtherNet/IP Fieldbus Gateway
Includes 1 x JetLink 1102
1 x DIN Rail Kit

Korenix Technology www.korenix.com 3