RE18302-06 VS161-165 Nlo
RE18302-06 VS161-165 Nlo
RE18302-06 VS161-165 Nlo
Size 6
Series 00
Maximum operating pressure 310 bar (4500 psi)
Maximum flow 60 l/min (15.85 gpm)
Ports G 3/8 - SAE8
01 02 03 04 05 06 07 08 Drain type I
L 7 25 0 C2 C3
C1 C4
Family
01 Compact directional valve L
a 1 0
Type
02 Flow diverters 7
P1 P2
Ports
03 G 3/8 DIN 3852 3 Drain type E
3/4-16 UNF (SAE8) C C2 C3
C1 C4
Control type
04 Solenoid (coil C48) without manual override 11
Solenoid (coil C48) with push-button type manual
1P a 1 0
override
Solenoid (coil C48) with screw type manual override 1F P1 P2
Hydraulic / pneumatic control 1) P1
Manual push and twist control H1 Spool variants
Spool variants
05 6 way / 2 position P1 side 6_ 6A
Drain type 6A 6B 6E 6F 6G
06 Internal drain ● ● – ● ● I
External drain ● ● ● – – E 6B
Voltage supply 31 07 03 01 00
07 Manual push and
– – – – – SG 6E
twist control
Without coil – – – – ● 00
12 V DC ● ● ● ● – OB
6F
13 V DC – ● – ● – AD
24 V DC ● ● ● ● – OC
27 V DC – ● – ● – AC
6G
48 V DC – – – ● – OD
Electric connections
08 Without coils 00
With coils, without mating connector
01
DIN EN 175301-803 2)
With coils, with bi-directional diode, without mating
03
connector vertical Amp-Junior
With coils, with bi-directional diode, without mating
07
connector DT04-2P
With coils and bipolar sheathed lead
31
350mm (13,8 in) long
Functional description
C1 P1 C2 C4 P2 C3
6 5 4 1 2 3
A valve basically consists of a housing (1), a control spool back the spool (2) and holds it in position “0”
(2), a return spring (3) and a solenoid (5). It is designed to The coil (4) is fastened to the tube by the ring nut (5).
connect two inlet lines P1 – P2 (normally a set of hoses) The manual override (6) allows to shift the spool (2) also in
and divert them to either the outlet ports (C1 – C4) with case of voltage shortage.
spool in position “0”, when the solenoid is de-energized, or An external drain, to be connected to tank, ensures shifting
to the outlet ports (C2 – C3) with spool in position “1”, operations also at higher working pressure.
when the solenoid is energized. Hydraulic / pneumatic pilot control, or manual push and
With the coil de-energized, the return spring (3) pushes twist control for spool shifting are available upon request.
Technical data
General
Valve weight kg (lbs) 3.0 (6.6)
Mounting position unrestricted
Ambient Temperature °C (°F) –20....+50 (-4....+122) (NBR seals)
Hydraulic
Maximum pressure with external drain (“E” type) bar (psi) 310 (4500)
Maximum pressure with internal drain (“I” type) bar (psi) 250 (3625)
Maximum pressure with internal drain and bar (psi) 310 (4500)
6F or 6G scheme
Maximum inlet flow l/min (gpm) 60 (15.85)
Hydraulic fluid
General properties: it must have physical lubricating Mineral oil based hydraulic fluids HL (DIN 51524 part 1).
and chemical properties suitable for use in hydraulic Mineral oil based hydraulic fluids HLP (DIN 51524 part 2).
systems such as, for example: For use of environmentally acceptable fluids (vegetable or
polyglycol base) please consult us.
Fluid Temperature °C (°F) –20....+80 (-4....+176) (NBR seals)
Permissible degree of fluid contamination ISO 4572: βx ≥ 75 X = 12...15
ISO 4406: class 20/18/15
NAS 1638: class 9
Viscosity range mm2/s 5....420
Internal leakage with 100 bar (1450 psi) cc/min min. 10 (0.61) - max. 20 (1.2)
secondary pressure at C (in3/min)
Electrical
Voltage type DC
Voltage tolerance (nominal voltage) % -10 .... +10
Duty Continuous, with ambient temperature ≤ 50°C (122°F)
Coil wire temperature not to be exceeded °C (°F) 150 (302)
Insulation class H
Compliance with Low Voltage Directive LVD 73/23/EC (2006/95/EC), 2004/108/EC
Coil weight with DIN 43650 – ISO 4400 connector kg (lbs) 0.5 (1.1)
Voltage V 12 13 24 27 48
Voltage type DC DC DC DC DC
Power consumption W 36 36 36 36 36
Current (nominal at 20 °C (68 °F)) A 3.0 2.77 1.53 1.32 0.75
Resistance (nominal at 20 °C (68 °F)) Ω 3.97 4.68 15.67 20.42 63.60
Note
For applications with different specifications consult us
Code Voltage [V] Connector type Coil description Marking Coil Mat no.
OB 01 12 DC EN 175301-803 C4801 12DC 12 DC R933000063
(Ex. DIN 43650)
OB 03 12 DC AMP JUNIOR C4803 12DC 12 DC R933000065
OB 07 12 DC DEUTSCH DT 04-2P C4807 12DC 12 DC R933000068
OB 31 12 DC Cable 350 mm long C4831 12DC 12 DC R933000064
AD 01 13 DC EN 175301-803 C4801 13DC 13 DC R933000069
(Ex. DIN 43650)
AD 07 13 DC DEUTSCH DT 04-2P C4807 13DC 13 DC R933000073
OC 01 24 DC EN 175301-803 C4801 24DC 24 DC R933000076
(Ex. DIN 43650)
OC 03 24 DC AMP JUNIOR C4803 24DC 24 DC R933000071
OC 07 24 DC DEUTSCH DT 04-2P C4807 24DC 24 DC R933000075
OC 31 24 DC Cable 350 mm long C4831 24DC 24 DC R933000070
AC 01 27 DC EN 175301-803 C4801 27DC 27 DC R933000077
(Ex. DIN 43650)
AC 07 27 DC DEUTSCH DT 04-2P C4807 27DC 27 DC R933000074
OD 01 48 DC DIN EN 175301-803 ISO C4801 48DC 48 DC R933000078
4400
Characteristic curves
psi bar 1 2
200 7
6
150 5
Pressure Δp
4
100
3
2
50
1
0 0
0 10 20 30 40 50 60 l/min
0 3 6 9 12 15 15.8 gpm
Flow Q
DI
psi bar
5000 350
300
4000
3000 1
Pressure p
200
2000 2
100
1000
0 0
0 10 20 30 40 50 60 l/min
0 3 6 9 12 15 15.8 gpm
Flow Q
) ( ) ( )
) ( ) ( )
(
(
)
)
(
(
(
)
( ) ( ) ( )
( ) ( )
(
( )
)
)
)
)
(
(
(
(
)
( ) ( ) ( ) ( )
)
)
( )
(
( )
(
(
( ) ( )
( )
)
( )
)
)
)
(
)
(
(
(
(
( ) ( ) )
(
( ) ( ) ( )
( )
)
(
)
(
)
( )
)
(
( )
(
)
(
( )
( )
( )
)
(
Electric connection
00 01
)
(
)
(
)
)
(
( ) ( )
(
03 Protection class: IP 65 with female connector 07 Protection class: IP 69 K with female connector
properly fitted (see drawing). properly fitted (see drawing).
)
( )
) (
)
)
)
(
)
(
(
)
(
)
)
(
(
( ) ( ) ( ) ( )
(
(
( )
31
( )
)
)
(
(
)
)
(
(
( )
( ) ( )
Bosch Rexroth Oil Control S.p.A. © This document, as well as the data, specifications and other information
Oleodinamica LC Division set forth in it, are the exclusive property of Bosch Rexroth Oil Control S.p.a..
Via Artigianale Sedrio, 12 It may not be reproduced or given to third parties without its consent.
42030 Vezzano sul Crostolo The data specified above only serve to describe the product. No statements
Reggio Emilia - Italy concerning a certain condition or suitability for a certain application can be
Tel. +39 0522 601 801 derived from our information. The information given does not release the
Fax +39 0522 606 226 / 601 802 user from the obligation of own judgment and verification. It must be
compact-hydraulics-cdv@boschrexroth.com remembered that our products are subject to a natural process of wear and
www.boschrexroth.com/compacthydraulics aging.
Subject to change.