Hubbell Model BW
Hubbell Model BW
Hubbell Model BW
Features
■ Reliable
� Only high grade materials used in
construction to ensure long operating life
� Hydrastone cement lining provides
superior protection and tank longevity
� Heavy duty construction withstands
demanding commercial/industrial use
■ Packaged System
� Factory selected and sized boiler water
control valve simplifies installation and
ensures reliable operation
■ Versatile
� Full range of styles, sizes, and optional
features to meet your exact heating needs
Applications
■ Schools
■ Office Buildings
Sports Venues NO
GLASS
■
Hotels
LINING
■
■ Industrial Facilities
■ Nursing Homes
■ Hospitals Model BW - Storage Tank Type
The Model BW is equipped with all operating controls and ready for ASME
immediate installation
U
A Heavy Duty Indirect Fired Water Heater
The Model BW is a fully packaged indirect fired water heater Whether you are heating potable water in a commercial
which utilizes boiler water or high temperature hot water (HTHW) building or process water in an industrial application, you can
as the energy source for heating potable water. The entire select a Hubbell BW model to do the job. When you specify
package is designed to be a reliable and long lasting source for and install a Hubbell water heater, you will be provided with a
hot water. Each component is carefully selected to ensure high quality product that is a long lasting and trouble free source for
performance in even the most demanding application. hot water.
Q?
What is the most common reason why a
water heater fails?
Unlined TaNks
An Unlined tank does not require a lining because the pressure vessel itself is
constructed from material which is impervious to the corrosive effects of hot water. This
type of tank will provide a significantly longer service life than all lined steel tanks, but is
initially more costly.
2
Model BW Storage Type Standard Equipment
Vessel Construction Boiler Water
Operating Controls
1. All welded carbon steel pressure vessel
designed and built in strict accordance with 1. Operating controls are factory selected, sized,
the ASME Code Section VIII and stamped, piped and tested to ensure reliable operation
certified, and registered with the National 2. All components are factory piped and ready for
Board of Boiler and Pressure Vessel boiler water in and out connections
Inspectors
3. Modulating control valve (Specify: 2-way or
2. All internal tank surfaces are lined with a 3-way) to regulate the flow of boiler water
minimum of 5⁄8" thick Hydrastone cement for through the coil. Modulating control valve to
superior protection and tank longevity be (Specify: electric or pneumatic) powered.
3. Designed for 125 psi working pressure and
hydrostatically tested
3
Overall Dimensions, Models BW and BWH
Actual Overall Dimensions (Inches) Storage Nominal Inlet Approx.
Storage Vertical Horizontal Tank Storage Outlet Shipping
Capacity Diameter Height Length Width Height Diameter Capacity Sizing Weight
(Gallons) “A” “B” “C” “D” “E” x Length (Gallons) (NPT) (Lbs.)
Note: All dimensions are approximate and subject to change. Please reference the submittal drawing for actual
dimensions. The tank selections above are shown for convenience. A full selection of storage capacities is available by
entering the desired capacity into the model number.
* 80, 120 and 150 gallon tanks do not come equipped with a manway. Please consult factory if desired on these sizes.
4
Outline Dimensions
Model BW (Vertical)
Convection Model Shown
Protective
Jacket
Pressure
Vessel
Insulation
12" x 16" B
Manway
Temperature
Probe
Boiler Water
Control Valve
Boiler Water
Entering
Heating
Coil 6"
Combination Cold Water
24" Inlet and Drain A
24" C
Temperature T&P Relief Lifting Hot Water
Probe Valve Lug Outlet
Withdrawal Protective
Space Jacket
Manway
Drain
Skid Base
(optional)
Heating Cold Water Inlet Side View
Coil
Modulating 3-Way
Diverting Valve
Style A
This is the most commonly selected method for regulat-
ing the boiler water. A 3-Way control valve allows only
Boiler Water Outlet
the required amount of boiler water into the heating coil
in order to satisfy the demand. Any excess boiler water
is diverted back to the boiler water circulating loop. This
valve type can be selected as either electric or pneu-
By-pass matic powered.
Option Note
Any and all optional equipment for a water heater must be called out in the written specifications. A model number in and of
itself does not reflect any optional equipment selected.
6
Master Specification: Model BW
Job Name engineer
Representative contractor
GENERAL
Provide a quantity of packaged type indirect fired storage heater(s) Model No. as manufactured
by HUBBELL Electric Heater Co., Stratford, CT. The pressure vessel shall be mounted on structural supports and be suitably insulated,
jacketed, painted and provided with lifting lugs. The entire unit is to be packaged ready for service connections.
PRESSURE VESSEL
The pressure vessel shall be all welded construction and ASME Code Section VIII stamped for a working pressure of 125 psi
( Optional Specification: psi ) and contain a minimum of gallons of storage. The storage vessel shall
be carbon steel and lined with seamless Hydrastone cement to a minimum thickness of 5/8" on 100% of all interior tank surfaces
( Optional Specifications: Phenolic lined steel tank, Hot dipped galvanized steel tank, Type 304 or 316L stainless steel tank, 90/10
Copper-nickel tank ). The pressure vessel is to be insulated with 3" thick energy conservation fiberglass blanket insulation and enclosed
in a heavy gauge galvanized steel metal jacket finished in gray hammertone enamel. The vessel shall be protected by an ASME approved
automatic reseating combination temperature and pressure relief valve set at the tank working pressure and 210oF.
HEATING SECTION
The heating coil shall be rated to heat GPH from oF to oF when supplied with GPM of boiler
o o
water ( Optional Specification: HTHW ) from F to F. The single wall ( Optional Specification: double wall )
heating coil shall be constructed from copper tubes ( Optional Specifications: 90/10 Copper-nickel, admiralty, stainless steel ) with all
non-ferrous wetted parts and designed for a maximum allowable working pressure of 150 psi at 275oF ( Optional Specification: 400
psi at 450oF ) maximum temperature. The coil head shall be fabricated steel ( Optional Specification: Stainless steel, copper alloy ).
CONTROLS
The water heater shall (shall not) be factory assembled and piped with a boiler water control valve. The boiler water control valve shall be
(Specify: Electric or Pneumatic) powered modulating 3-way diverting valve that will regulate the flow of boiler water to the heating coil
and will divert unused boiler water back to the loop ( Optional Specification: ON/OFF modulating 2-way valve will regulate the flow of
boiler water to the heating coil without diverting back to the boiler, factory wired thermostat to provide ON/OFF control of a (supplied, not
supplied) boiler water pump.
In addition, the water heater may be supplied with the following optional features:
Option Domestic water dial temperature and pressure gauge shall be factory installed in the tank.
Option The water heater shall be equipped with a factory packaged intra-tank circulator to continuously circulate water within
the tank to reduce stratification.
Option The heating coil shall be wrapped and baffled and piped with an integral pump package to force circulate water over
the heating coil in order to reduce the coil size.
Option Single solenoid safety system to close the boiler water supply to the heating coil should the water temperature in the
tank reach the hi-limit set point. Requires 5 Amp, 120 Volt service.
Option Double solenoid safety system dumps over heated water in the storage tank to drain in addition to closing the boiler
water supply to the control valve. Requires 5 Amp, 120 Volt service.
WARRANTY
HUBBELL shall warranty all components against defects in workmanship and material for a period of one (1) year from date of start-up
and the pressure vessel for a full five (5) years Non Pro-Rated ( Optional Specification: full ten (10) years Non Pro-Rated ) from date of
start-up, provided that the unit is started within three (3) months of date of shipment and installed and operated within the scope of the tank
design and operating capability. Each water heater shall be shipped with a complete set of installation and operating instructions including a
spare parts list and approved drawing.
The Electric Heater Company ■ P.O. Box 288 ■ Stratford, CT 06615-0288 ■ Phone: 203-378-2659 ■ Fax: 203-378-3593
info@hubbellheaters.com ■ www.hubbellheaters.com
7