M.I.C.

-BuildingWorks®
PROJECT REPORT
Prepared For:

Project: ADANI GREEN ENERGY LTD

Location: RAJASTHAN

Recipients Of Design Products Provided By M.I.C. Industries Shall Be Solely Responsible For Consulting With A Structural
Engineer To Conduct A Review And Validation Of The Analysis. In No Event Shall M.I.C. Industries, Inc. Be Liable For Any
Damages Whatsoever (Including, Without Limitation, Damages For Loss Of Business Profits, Business Interruption, Loss Of
Business Information, Or Other Pecuniary Loss) Arising Out Of The Mathematical Results From The Software Analysis Even If
M.I.C. Industries, Inc. Has Been Advised Of The Possibility Of Such Damages.
Prepared For: ADANI GREEN ENERGY LTD

BUILDINGWORKS_1.XBM

DATE: 04-06-2023 Page 2 of 14

Project Summary Page Building Geometry

Building Summary Panel Segment Details:


Building Length 80.00 m Step No. Length (m) Cal Radius (m)
End Wall Area 110.5 Sq m
1 .90
Total Volume 8760.7 cu m
2 5.44 4.37
Floor Area 1544.0 Sq m
3 5.47
Interior Width 18.89 m
4 3.47 4.37
Interior Height 7.30 m
5 5.47
Interior Surface Area 3121.21 Sq m
6 5.44 4.37
Steel Summary * 7 .90
Panel Weight 309.0 kg
Total Panel Length 27.09 m
Superstructure Steel Quantity 40.79 tonne
Superstructure Steel Thickness 1.60 mm
End Wall Steel Quantity 2.75 tonne
End Wall Steel Thickness 0.80 mm

Loading Summary
Snow Load 0 kg/m2
Wind Load 170 km/h
* Values do not include scrap factors

M.I.C. - BuildingWorks® M.I.C. Industries, Inc. Copyright © 2016-2017 M.I.C. Industries, Inc.
Reston, VA 20190 USA All Rights Reserved
Prepared For: ADANI GREEN ENERGY LTD

BUILDINGWORKS_1.XBM

DATE: 04-06-2023 Page 3 of 14

INPUT DATA: BuildingType MIC-240 Unit System: Metric


End Wall Type MIC-120
Building Shape Gable
Wall Height 0.90 m
Total Height 7.50 m
Total Width 19.30 m
Crown Radius 4.57 m
Eave Radius 4.57 m
Total Length 80.00 m
Wall Type Normal Panel
Base Type Fixed (Concrete)

LOAD DATA: Dead Load 0.00 kg/m2


Live Load 58.59 kg/m2
Insulation Load 0.00 kg/m2
Snow Load 0.00 kg/m2
Thermal Factor Unheated, Factor 1.2
Snow Exposure Fully Exposed, Factor 0.9
Obstructed Roof No
Enclosure Clasification Enclosed Building
Wind Velocity 170.00 km/h
Wind Exposure Exposure C, Open Terrain
Elevated Base Height 0.00 m
Near Hurricane Coastline No
Building Category Catagory II, Other
Adjacent Roof No

CONCENTRATED LOADS:
None

M.I.C. - BuildingWorks® M.I.C. Industries, Inc. Copyright © 2016-2017 M.I.C. Industries, Inc.
Reston, VA 20190 USA All Rights Reserved
ADANI GREEN ENERGY LTD
Geometry Plot
BUILDINGWORKS_1.XBM

DATE: 04-06-2023 Page 4 of 14

M.I.C. - BuildingWorks® M.I.C. Industries, Inc. Copyright © 2016-2017 M.I.C. Industries, Inc.
Reston, VA 20190 USA All Rights Reserved
Prepared For: ADANI GREEN ENERGY LTD

BUILDINGWORKS_1.XBM

DATE: 04-06-2023 Page 5 of 14

Figure 1

LOADING CONDITIONS
CODE: IBC 2006 International Building Code
STANDARD: ACSE-7-05 Minimum Design Loads for Buildings and Other Structures
Building Category (Table 1-1) Catagory II, Other
Wind Exposure (6.5.6.3) Exposure C, Open Terrain
Snow Exposure (Table 7-2) Fully Exposed, Factor 0.9
Snow Thermal Factor (Table 7-3) Unheated, Factor 1.2
Importance Factor (Table 7-4) Catagory II, Factor 1.0
Wind Speed 170.00 km/h Enclosed Building
Ground Snow Load 0.00 kg/m2
Roof Minimum Live Load (4.9.1) 58.59 kg/m2
Design Wind Pressure (6.5.12.2.2) 100.67 kg/m2
Design Snow Roof Load (7.3) 58.59 kg/m2
Building Panel MIC-240 1.60 mm ASTM-A653 Grade 50

Prepared By: M & B Engineering Ltd.


Proflex Systems
51, MB House
Naranpura
Ahmedabad

The undersigned hearby


certifies that the
engineering calculations
meet the current codes. Signature Date

M.I.C. - BuildingWorks® M.I.C. Industries, Inc. Copyright © 2016-2017 M.I.C. Industries, Inc.
Reston, VA 20190 USA All Rights Reserved
Prepared For: ADANI GREEN ENERGY LTD

BUILDINGWORKS_1.XBM

DATE: 04-06-2023 Page 6 of 14

Load Cases (Span Loads) Evaluated


1 - Structure Dead & Conc. Loads
2 - Wind Normal to Ridge 1
3 - Wind Normal to Ridge 2
4 - Wind Parallel to Ridge
5 - Wind Internal Pressure
6 - Live or Snow-Uniform
7 - Live or 1/2 Snow-OuterQuarters
8 - Live or 1/2 Snow-Middle Half
9 - Live on Left Half
10 - Live on Right Half

Load Combinations Evaluated


1 - +1.00 x Structure Dead & Conc. Loads
2 - +1.00 x Structure Dead & Conc. Loads +1.00 x Live or Snow-Uniform
3 - +1.00 x Structure Dead & Conc. Loads +1.00 x Live or 1/2 Snow-OuterQuarters
4 - +1.00 x Structure Dead & Conc. Loads +1.00 x Live or 1/2 Snow-Middle Half
5 - +1.00 x Structure Dead & Conc. Loads +1.00 x Live on Left Half
6 - +0.60 x Structure Dead & Conc. Loads +1.00 x Wind Normal to Ridge 1 +1.00 x Wind Internal Pressure
7 - +0.60 x Structure Dead & Conc. Loads +1.00 x Wind Normal to Ridge 1 -1.00 x Wind Internal Pressure
8 - +0.60 x Structure Dead & Conc. Loads +1.00 x Wind Normal to Ridge 2 +1.00 x Wind Internal Pressure
9 - +0.60 x Structure Dead & Conc. Loads +1.00 x Wind Normal to Ridge 2 -1.00 x Wind Internal Pressure
10 - +0.60 x Structure Dead & Conc. Loads +1.00 x Wind Parallel to Ridge +1.00 x Wind Internal Pressure
11 - +1.00 x Structure Dead & Conc. Loads +0.75 x Live or Snow-Uniform +0.75 x Wind Normal to Ridge 1 +0.75 x Wind Internal Pressure
12 - +1.00 x Structure Dead & Conc. Loads +0.75 x Live or 1/2 Snow-OuterQuarters +0.75 x Wind Normal to Ridge 1 +0.75 x Wind Internal Pressure
13 - +1.00 x Structure Dead & Conc. Loads +0.75 x Live or 1/2 Snow-Middle Half +0.75 x Wind Normal to Ridge 1 +0.75 x Wind Internal Pressure
14 - +1.00 x Structure Dead & Conc. Loads +0.75 x Live on Left Half +0.75 x Wind Normal to Ridge 1 +0.75 x Wind Internal Pressure
15 - +1.00 x Structure Dead & Conc. Loads +0.75 x Live on Right Half +0.75 x Wind Normal to Ridge 1 +0.75 x Wind Internal Pressure
16 - +1.00 x Structure Dead & Conc. Loads +0.75 x Live or Snow-Uniform +0.75 x Wind Normal to Ridge 1 -0.75 x Wind Internal Pressure
17 - +1.00 x Structure Dead & Conc. Loads +0.75 x Live or 1/2 Snow-OuterQuarters +0.75 x Wind Normal to Ridge 1 -0.75 x Wind Internal Pressure
18 - +1.00 x Structure Dead & Conc. Loads +0.75 x Live or 1/2 Snow-Middle Half +0.75 x Wind Normal to Ridge 1 -0.75 x Wind Internal Pressure
19 - +1.00 x Structure Dead & Conc. Loads +0.75 x Live on Left Half +0.75 x Wind Normal to Ridge 1 -0.75 x Wind Internal Pressure
20 - +1.00 x Structure Dead & Conc. Loads +0.75 x Live on Right Half +0.75 x Wind Normal to Ridge 1 -0.75 x Wind Internal Pressure
21 - +1.00 x Structure Dead & Conc. Loads +0.75 x Live or Snow-Uniform +0.75 x Wind Normal to Ridge 2 +0.75 x Wind Internal Pressure
22 - +1.00 x Structure Dead & Conc. Loads +0.75 x Live or 1/2 Snow-OuterQuarters +0.75 x Wind Normal to Ridge 2 +0.75 x Wind Internal Pressure
23 - +1.00 x Structure Dead & Conc. Loads +0.75 x Live or 1/2 Snow-Middle Half +0.75 x Wind Normal to Ridge 2 +0.75 x Wind Internal Pressure
24 - +1.00 x Structure Dead & Conc. Loads +0.75 x Live on Left Half +0.75 x Wind Normal to Ridge 2 +0.75 x Wind Internal Pressure
25 - +1.00 x Structure Dead & Conc. Loads +0.75 x Live on Right Half +0.75 x Wind Normal to Ridge 2 +0.75 x Wind Internal Pressure
26 - +1.00 x Structure Dead & Conc. Loads +0.75 x Live or Snow-Uniform +0.75 x Wind Normal to Ridge 2 -0.75 x Wind Internal Pressure
27 - +1.00 x Structure Dead & Conc. Loads +0.75 x Live or 1/2 Snow-OuterQuarters +0.75 x Wind Normal to Ridge 2 -0.75 x Wind Internal Pressure
28 - +1.00 x Structure Dead & Conc. Loads +0.75 x Live or 1/2 Snow-Middle Half +0.75 x Wind Normal to Ridge 2 -0.75 x Wind Internal Pressure
29 - +1.00 x Structure Dead & Conc. Loads +0.75 x Live on Left Half +0.75 x Wind Normal to Ridge 2 -0.75 x Wind Internal Pressure
30 - +1.00 x Structure Dead & Conc. Loads +0.75 x Live on Right Half +0.75 x Wind Normal to Ridge 2 -0.75 x Wind Internal Pressure
31 - +1.00 x Structure Dead & Conc. Loads +0.75 x Live or Snow-Uniform +0.75 x Wind Parallel to Ridge +0.75 x Wind Internal Pressure
32 - +1.00 x Structure Dead & Conc. Loads +0.75 x Live or 1/2 Snow-OuterQuarters +0.75 x Wind Parallel to Ridge +0.75 x Wind Internal Pressure
33 - +1.00 x Structure Dead & Conc. Loads +0.75 x Live or 1/2 Snow-Middle Half +0.75 x Wind Parallel to Ridge +0.75 x Wind Internal Pressure
34 - +1.00 x Structure Dead & Conc. Loads +0.75 x Live on Left Half +0.75 x Wind Parallel to Ridge +0.75 x Wind Internal Pressure

M.I.C. - BuildingWorks® M.I.C. Industries, Inc. Copyright © 2016-2017 M.I.C. Industries, Inc.
Reston, VA 20190 USA All Rights Reserved
Prepared For: ADANI GREEN ENERGY LTD

BUILDINGWORKS_1.XBM

DATE: 04-06-2023 Page 7 of 14

Critical Load Case/Combination

8 +0.60 x Structure Dead & Conc. Loads +1.00 x Wind Normal to Ridge 2 +1.00 x Wind Internal Pressure

Figure 2

TYPICAL LOADING DIAGRAM

Prepared By: M & B Engineering Ltd.


Proflex Systems
51, MB House
Naranpura
Ahmedabad

The undersigned hereby


certifies that the
engineering calculations
meet the current codes. Signature Date

M.I.C. - BuildingWorks® M.I.C. Industries, Inc. Copyright © 2016-2017 M.I.C. Industries, Inc.
Reston, VA 20190 USA All Rights Reserved
Prepared For: ADANI GREEN ENERGY LTD

BUILDINGWORKS_1.XBM

DATE: 04-06-2023 Page 8 of 14

Interaction Equations
Specification: AISI North American Specification for the Design of Cold-formed
Steel Structural Members 2007 Edition
Node Location of Maximum Loading = 1 of 46

Critical Case as shown in Figure 2 (Critical Load Case Page)

Section 3.2 Shear (Shear Strength Ratio)

1.67 * 0.47
= = 0.19 <= 1.00 OK!
4.22 Load Case = 26, Element = 46

Equation C 3.3.1-1 (Shear + Bending Strength Ratio)

1.67 * 49.52 1.67 * 0.23


83.15 4.22
= 1.00 <= 1.00 OK!
Load Case = 8, Element = 1
Equation C 5.1.1-1 (Axial + Bending Strength Ratio) Shear = 206.8 kg
Axial = 11.02 kg
1.67 * 49.52 1.80 * 0.03 Moment = -570.57 kg-m
= +
83.15 112.10
= 1.00 <= 1.00 OK!
Load Case = 8, Element = 1
Where: Figure 3
Ωv = Factor of Safety for Shear
Ωb = Factor of Safety for Bending
Ωt = Factor of Safety for Axial
V = Shear Strength
M = Moment
P or T = Axial Strength
Vn = Nominal Shear Strength
Mn = Nominal Moment
Pn or Tn = Nominal Axial Strength

Prepared By: M & B Engineering Ltd.


Proflex Systems
51, MB House
Naranpura
Ahmedabad

The undersigned hereby


certifies that the
engineering calculations
meet the current codes. Signature Date

M.I.C. - BuildingWorks® M.I.C. Industries, Inc. Copyright © 2016-2017 M.I.C. Industries, Inc.
Reston, VA 20190 USA All Rights Reserved
Prepared For: ADANI GREEN ENERGY LTD

BUILDINGWORKS_1.XBM

DATE: 04-06-2023 Page 9 of 14

STRUCTURAL RESULTS:

COMPUTED DESIGN ROOF LOADS:

Wind Pressure 100.67 kg/m2


Snow/Live Pressure 58.59 kg/m2

COMPUTED STRUCTURAL RESULTS:

Machine Type MIC-240


End Wall Type MIC-120

Roof Side Wall End Wall


Required Thickness 1.60 1.60 0.80 mm
Required Strength 35 35 35 kg/mm2

MAXIMUM STRENGTH RATIOS:


Note - OVERSTRESS conditions exist.

Shear 0.17 0.19 0.18


Shear & Bending 0.89 1.00 1.58
Axial & Bending 0.94 0.99 1.24
Strengthened Wall 0.00

Notes: A Normal Panel Type Wall With A Fixed (Concrete) Base Type Was Used To Determine Strength Ratios!
Seismic loadings are not checked in the analysis.
Supporting structures should be checked separately if applicable.

M.I.C. - BuildingWorks® M.I.C. Industries, Inc. Copyright © 2016-2017 M.I.C. Industries, Inc.
Reston, VA 20190 USA All Rights Reserved
Prepared For: ADANI GREEN ENERGY LTD

BUILDINGWORKS_1.XBM

DATE: 04-06-2023 Page 10 of 14

SUMMARY OF RESULTS FOR COMPONENT LOAD CASES:


Notes: 1. Reactions are given per unit m
2. Positive forces on footing are down and to the left
3. Positive moment on footing is clockwise
4. Forces are kg, Moments are kg-m

COMPONENT LOAD CASE DESCRIPTIONS:


1 - Structure Dead & Conc. Loads
2 - Wind Normal to Ridge 1
3 - Wind Normal to Ridge 2
4 - Wind Parallel to Ridge
5 - Wind Internal Pressure
6 - Live or Snow-Uniform
7 - Live or 1/2 Snow-OuterQuarters
8 - Live or 1/2 Snow-Middle Half
9 - Live on Left Half
10 - Live on Right Half

REACTION MAGNITUDES AT GROUND LEVEL:


Left Side Right Side
Load Case Horizontal Force (kg) Vertical Force (kg) Moment (kg-m) Horizontal Force (kg) Vertical Force (kg) Moment (kg-m)
1 157 253.42 -255.54 -156.96 253.42 255.42
2 -323.29 -294.73 626.25 33.91 -419.31 78.47

3 -367.72 4.74 963.78 -203.7 -305.88 727.2


4 -217.28 -578.09 414.98 217.21 -578.09 -414.8
5 -65.73 -174.89 125.54 65.71 -174.88 -125.48
6 454.55 565.49 -759.99 -454.43 565.48 759.64

7 346.06 297.76 -649.32 -345.93 297.75 648.95


8 108.49 267.73 -110.67 -108.49 267.73 110.68
9 227.34 444.84 -180.59 -227.07 120.62 579.06
10 227.21 120.64 -579.4 -227.35 444.86 180.58

Note: These values are for load cases only. Add individual values to create load
combinations per your local ordinance. All loads are service (un-factored) loads.

M.I.C. - BuildingWorks® M.I.C. Industries, Inc. Copyright © 2016-2017 M.I.C. Industries, Inc.
Reston, VA 20190 USA All Rights Reserved
Prepared For: ADANI GREEN ENERGY LTD

BUILDINGWORKS_1.XBM

DATE: 04-06-2023 Page 11 of 14

Construction Summary Page Building Geometry

Building Information: Panel Segment Details:


Building Shape Gable Step No. Length (m) Cal Radius (m)
UBM Building Type Gable Type 3
1 .90
Building Length 80.00 m
2 5.44 4.37
3 5.47
Superstructure Panels:
4 3.47 4.37
Panel Type MIC-240
5 5.47
Steel Thickness 1.60 mm
6 5.44 4.37
Number of Picks 44
7 .90
Panel Weight 309.03 kg
Total Panel Length 27.09 m
Number of Carriers 14
Quantity of Steel 40.79 tonne

Endwall Panels: Prepared By: M & B Engineering Ltd.


Panel Type MIC-120 Proflex Systems
Steel Thickness 0.80 mm 51, MB House
Number of Panels 124 Naranpura
Quantity of Steel 2.75 tonne Ahmedabad

M.I.C. - BuildingWorks® M.I.C. Industries, Inc. Copyright © 2016-2017 M.I.C. Industries, Inc.
Reston, VA 20190 USA All Rights Reserved
ADANI GREEN ENERGY LTD
Lifting Planner
BUILDINGWORKS_1.XBM

DATE: 04-06-2023 Page 12 of 14

Lifting Configuration: Lifting Locations:


Location Arc Length from End (m) Arc Length from Center (m)
A .00 -13.55
B 8.17 -5.38
C 10.85 -2.69
D 13.55 .00
E 16.24 2.69
F 18.92 5.38
G 27.09 13.55

Panel Type MIC-240


Number of Spreader Bars 3
Pick Weight (3 Panels) 927 kg
Total Lifting Weight 1591.8 kg
Total Panel Length 27.09 m
Minimum Boom Length 21.64 m

Required Item Part Number Qty Weight (kg)


Center Spreader Bar 105-4951-A 1 256.4
End Spreader Bar 105-4960-A 2 286.2
18 ft (5.5 m) Pear Link Cable 105-4652 1 18.3
Snatch Block 105-4657 4 8
3/4 in (19 mm) Shackle 105-4654 2 2.2
1/2 in (12 mm) Shackle 101-4909 12 3.6
35 ft (10.7 m) Suspension Cable 105-4659 2 10
Lifting Bracket 105-4470-A 4 80
Total Weight = 664.7

M.I.C. - BuildingWorks® M.I.C. Industries, Inc. Copyright © 2016-2017 M.I.C. Industries, Inc.
Reston, VA 20190 USA All Rights Reserved
ADANI GREEN ENERGY LTD
Panel Inspection Plot
BUILDINGWORKS_1.XBM

DATE: 04-06-2023 Page 13 of 14

M.I.C. - BuildingWorks® M.I.C. Industries, Inc. Copyright © 2016-2017 M.I.C. Industries, Inc.
Reston, VA 20190 USA All Rights Reserved
ADANI GREEN ENERGY LTD
Site Plan
BUILDINGWORKS_1.XBM

DATE: 04-06-2023 Page 14 of 14

M.I.C. - BuildingWorks® M.I.C. Industries, Inc. Copyright © 2016-2017 M.I.C. Industries, Inc.