Spot Welding Instructions

1. CONTROL PANEL LAYOUT

1
633 Coronation Drive
Scarborough, ON
M1E 2K4
Digital Shovel Holdings Inc.

P 647 607 9729


www.digitalshovel.com

CYCLE MODE
Each of the 50 possible schedules has a cycle mode parameter that dictates the sequence of events that will
follow in an initiation.

CYCLE MODE MODE Description

The control can be initiated for only one sequence


00 NON REPEAT

After initiation, the control internally re-initiates as long as the initiation


01 REPEAT
switch is maintained closed

02 CHAINED Several schedules can be chained together so that several consecutive


schedules can be sequenced from one initiation

Several schedules can be sequenced successively upon separate initiations


03 SUCCESSIVE

04 CONDITIONAL Valves remain active at the end of HOLD (this is indicated by blinking HOLD
SUCCESSIVE indicator LED ) until control is re- initiated and next schedule will be
sequenced

05 WAIT HERE After FS3 initiation, wait either in SQUEEZE or WELD COOL or HOLD part of
the sequence until control is re- initiated with FS7 or FS11 and schedule 10 or
20 will be sequenced

SLOPE MODE
Slope mode provides a way to change the current gradually, either Increasing or decreasing. The gradual
increase or decrease is determined by the Slope current and the number of slope cycles in the SLOPE COUNT

SLOPE MODE MODE Description

Slope is disabled
00 NO SLOPE

Causes current to start from a low level and increase for a predetermined
01 UPSLOPE
number of cycles

02 DOWNSLOPE Causes current to start from a high level and reduce for a predetermined
number of cycles

2
633 Coronation Drive
Scarborough, ON
M1E 2K4
Digital Shovel Holdings Inc.

P 647 607 9729


www.digitalshovel.com

VALVE MODE
The three solenoid valves are activates based on the code shown below

VALVE DESCRIPTION Valve Outputs on TS1


CODE VALVE Indicator LEDs

VALVE3 VALVE2 VALVE1

00 OFF OFF OFF All valves off None

01 OFF OFF ON Valve 1 active SV1 SV2

02 OFF ON OFF Valve 2 active SV3 SV4

03 OFF ON ON Valves 1 & 2 active SV1 SV2 & SV3 SV4

04 ON OFF OFF Valve 3 active SV5 SV6

05 ON OFF ON Valves 1 & 3 active SV1 SV2 & SV5 SV6

06 ON ON OFF Valves 2 & 3 active SV3 SV4 & SV5 SV6

07 ON ON ON Valves 1, 2 & 3 active SV1 SV2, SV3 SV4 & SV5 SV6