ACERINOX, S. A.

FABRICA DEL CAMPO DE


GIBRALTAR
INSPECTION CERTIFICATE
PALMONES (LOS BARRIOS)
TENO. (34) -956-62 93 00
ISO 9001
CERTIFICAT D' INSPECTION 3.1
FAX (34) -956-62 93 11 ISO 14001
P. O. BOX 83 ACCORDING TO CERTIFICATE N0
Certified systems of management
11370 LOS BARRIOS (CADIZ) SUIVANT EN 10204 CERTIFICAT N0 89 2021 3940 10001 1
in astm current and quality

CUSTOMER Our order N 0 Your order N 0


CLIENT n/commande v/commande
TAD LOGISTICS YE 97412 UMI 01-21
P.O. BOX 111095 TRADE MARK INSPECTOR’S STAMP STEELMAKING PROCESS
EMIRATOS ARABES SIGLE DU PRODUCTEUR CACHET DE L’AGENT DE CONTROLE PROCEDE D’ELABORATION

A.O.D
REQUIREMENTS INTERGRANULAR CORROSION TEST GRADE FINISH
EXICENCES CORROSION INTERGRANULAIRE TEST NUANCE FINI

ASTM-A240 Ed15: A 480 Ed15; ASTM-A240 secll-AEd15; SA480Ed15 ASTM-A-262 PRACTICA E Acx 240 TP-304 NO1

DIMENSIONS
DIMENSIONS

COIL / BOX CONTENT THICKNESS WIDTH LENGTH MARKS QUANTITY TEST N O


BOBINE/CAISSE CONTENU EPAISSEUR LORGEUR LONGUEUR MARQUE QUANTITY ECHANTILLON

T50446 06K5E7 A 16,00 1250,00 2500,00 8000 kg 20 06K5E7 C


T52068 06L1W8 A 45,00 1250,00 2500,00 5630 kg 5 06L1W8 C
T52068 06K3W9 A 52,00 1260,00 2500,00 5200 kg 4 06K3W9 C
T52068 06L8W6 A 75,00 1250,00 2500,00 5630 kg 3 06L8W6 C

CHEMICAL ANALYSIS / COMPOSITION CHIMIQUE ( % )


HEAT N O

COULEE C CR MN NI P S SI
REQUIREMENTS 18,000 8,000
EXIGENCES 0,080 20,000 2,000 12,000 0,045 0,030 1,000
06K5E7 0,042 18,719 1,328 8,165 0,023 0,010 0,498
06L1W8 0,045 18,766 1,265 8,122 0,026 0,012 0,437
06K3W9 0,048 18,778 1,267 8,177 0,024 0,009 0,498
06L8W6 0,040 18,790 1,298 8,124 0,022 0,008 0,442

M E C H AN I CAL P R O P E R T I E S / CARACTERISTIQUES MECANIQUES


PROBE
TEST N O Rm. Rp 0.2 A50 HV10
TYPE
SIT

ITILLION N/MM 2 N/MM 2 %


REQUIREMENTS 515,00 205,00 40,0
EXIGENCES 90,00
06K5E7 C T 619,85 271,74 51,76 83,00
06L1W8 C T 629,72 270,92 52,57 85,00
06K3W9 C T 611,63 277,30 53,89 82,00
06L8W6 C T 625,49 274,42 50,73 84,00

REMARKS / REMARQUES SURFACE AND DIMENSIONAL CONTROL


INSPECTION DIMENSIONELLE ET VISUELLE
Temperatura de hipertemple entre 1050 y 1100 0 C.
The delivery is in accordance with the order
UT TEST AS PER ASTM A 578/A 578M CARRIED OUT AND FOUND SATISFACTORY
SATISFACTORY
Satisfaisant

WORK INSPECTOR
AGENT DE CONTROLE

A. Heredia

Palmones, 12 JANUARY 2021