MMIHT-001B HEAT TRANSFER LAB

HEAT TRANSFER - FORCED CONVECTION APPARATUS

BLOWER

ATS
Mild steel tube VALUE
T2

CAFICE
T3

T4

T6

HEATER

h-07
MMI-HT-001B HEAT TRANSFER LAB

INTRODäCTION

Forced convection is a mechanism, or type of transport in which fluid motion is


generated by anexternal source (like apump, fan, suction device, etc.). It should be
onsidered as one of the main methodsof useful heat transfer as significant amounts of
heat energy canbe transported very cfficiently.
THEORY
The experimental setup consistsof atube through which air is sent in by a
blower. The test section consists of a long electrical surface heater on the tube which
ser es as a constant heat flux source on the flowing medium. The inlet and outlet
temperatures of theflowing air aremeasured by thermocouples and also the
temperatures at several locations along the surface heater from which on average
temperature can be obtained. An orifice meter in the tube is used to measure the air
flow rate with a 'Utube water manometer. An ammeter and a voltmeter are provided to
measure the power input to the heater. A power regulator is provided to vary the
power input to heater. A multipointdigital temperature indicator is provided to
measure the above thermocouples input.
SPECIFICATION
Tube with band heaters (400W,5Omm Diameter,300mm Length) on the surface of
the tube.
v Dimmer-Stat to conduct the experiments at different
temperatures
Thermocouples (K-type.)8 channels are provided on the surface of the Tube at
suitable positions and in the line of airflow for measurement of
temperatures.
Digital temperature indicator with channel selector is provided for the
temperature indication.
Digital Volt1neter and Ammeter for Power
Blower (industrial) measurement.
600W,Speed controller to blowthe air inside heated tube.
slasS manometer with oriiice assembles for measurement of
tube. airflow across the
Also consists of other instrumentation and Accessories required for the panel.
MMI-HT-001B HEAT TRANSFER LAB

EXPERIMENT

AIM
Convection inside
To determine the heat transfer coefficient on the given Forced
tube Apparatus.
APPARATUS REQUIRED
Apparatus
ó Forced Convection inside tube
SPECIMENUSED
Length
Mild steel tube 50mm Diameter, 300
FORCED CONVECTION

1. EXPERIMENTAL METHOD:
VXI=hAAt
T,- Ta
Where,
of air [0C].
At= Average temperature of heater - Average temperature
A =ndl
A = Area of heat transfer.
d= diameter of the tube =0.05m
l= length of the tube =0.3m.
h = heat transfer co-efficient [W/m2 C|
VI =Power input to heater.

2. THEORITICAL METHOD:
Q=Cdxal x a2 V2gho/ Na12 -a22 m3/ sec.
ho head of air causing theflow.
-{h) - h2]x(pw/pa]
pw =Density of water = 1000kg/m3.
pa = Density of air = 1.16 kg/m3.
h1, h2 = Manometer reading in m.
al = Area of the tube.
a2 = Area of the orifice.
Q= Volume of air flowing through the tube.
Cd =0.6
VELOCITY OF AIR:
V=Q/a m/sec.
HEAT TRANSFER LAB
MMI-HT-001B

REYNOLDS NUMBER:
Re VD/ D.
V- Velocity of air
D- Dia. of the pipe.
D-Kineatic viscosity of air.
Nu = hD/K air.
K= Thermal conductivity of
Nu0,023 x Re0.8 x Pr0.4
Re = ReynoldsNumber.
Pr= Prandtl Number.

PROCEDURE
1. Switch on the main.
2.Switch on the blower.
Adjust the regulator to any desired power into input to heater.
3. valve to any desired flow rate of
air.
4. Adjust the position of the reached.
5. Wait till steady state temperature is and h2.
6. Note Down the manometer reading hl tube, also air inlet and outlet
along the
7. Note Down the terperatures
temperature.
8. Note down the voltneter and ammeter reading.
and repeat the
9. Adjust the position of the valve and vary the flow rate of air
experiment.
10. For various valve openings and for various power inputs the readings may
Be taken to repeat the experiments.
TABULATION

Inlet Manometer
Temp. Outlet Temp.of Duct Reading
Voltmeter mmeter Of Temp. Position(°C) (mm)
SI.No.
Reading Rezding Air, of Air,
T4 T5 T6 hl h2
{volts) (amps) T1 T7 T2 T3

Ex no: 9
Micro Mech Instruments, ch-97
MMIHT 0018

RESULT
Thus the experiment of the forced convection is conducted and heat transter
Co-efficient are calculated.