Equipment category
High performance pumping mechanism
For equipment category 1 (gas) consult BOC Edwards.
The EH has a high quality, oil-free pumping mechanism. This offers:
• Quiet, vibration free operation Gas auto-ignition temperature
• Rugged and corrosion resistant The temperature classifications applied to the chemical EH pumps relate to
• Advanced shaft-seal technology – no oil contamination of process the auto-ignition temperature of flammable materials that can be pumped:
chamber • The EH1200C, EH2600C, EH4200C and chemical EH pumps that have
The corrosion resistant pumping mechanism is manufactured from high a T3 classification are suitable for pumping flammable materials that have
grade cast iron. The proven shaft-seal arrangement ensures that no oil an auto-ignition temperature greater than 200 °C.
enters the pumping stator, and the absence of internal and external by-pass • Chemical EH pumps that have a T160 classification are suitable for
lines and valves which may corrode or stick minimizes maintenance pumping flammable materials that have an auto-ignition temperature
requirements. greater than 160 °C.
The design of the shaft seals is optimized to ensure that no lubricants can Explosion proof
migrate into the pumping mechanism. This maintains booster pump Explosion proof boosters are annotated with the suffix "C".
performance in applications which demand the highest standard of • EH boosters may be ordered with explosion proof motors either
cleanliness. In addition, this prevents the build-up of trapped particles on
the rotor lobes and end-faces which have very close tolerances.
individually, or as part of an explosion proof system.
• Explosion proof is generally applicable in N. America and the rest of the
9
The dynamically balanced rotors and precision ground gears contribute to PAGE
world (excluding Europe). 61
the smooth, quiet operation of the pumps, as demanded by manufacturers Explosion-proof boosters will be supplied fitted with an explosion-proof
of advanced technology equipment. motor (suitable for 60 Hz operation) approved to CSA, Division 1 area, Gas
Class I Group C & D and Dust Class II Group F & G, Temperature Class T3C.
BROAD APPLICATION COVERAGE
EH pumps with hydrokinetic drive
EH mechanical boosters are available to cover a broad range of industrial
EH booster pumps have a unique and patented hydrokinetic fluid drive,
and chemical process applications.
which couples the motor to the pumping mechanism. The hydrokinetic
Industrial drive offers the following advantages:
Industrial EH boosters are safe to handle non-flammable gases and vapors • Pump down times cut by up to 50%
within the normal operating parameters of the booster. • Reduced capital and operating costs
• No pressure sensors, by-pass lines or valves
• Can operate continuously at all pressures – when used with a backing
pump
with effective pumping speeds of up to 4140 m3h-1 / 2440 ft3min-1. The pump
bodies of the EH1200, EH2600 and EH4200 pumps are water-cooled.
Two versions of each EH booster pump are available, with different oils
2
used for the lubrication of the seals and gears. The standard version uses 10
mineral oils, such as Ultragrade 20. The alternative version has PFPE
(perfluoropolyether) oils and is suitable for applications where oxygen or C
Tor r
1
10
Pump-down times cut by up to 50% The hydrokinetic drive allows
the booster pump to be started at the same time as the backing pump
(at atmospheric pressure) as it prevents motor overload. The EH booster A
pump therefore assists the pumping process from the start of pump-down. 10
0
B
In comparison pumping systems with conventional, direct drive mechanical
booster pumps (where the booster pump is switched on when the
chamber pressure has been reduced to, typically, less than 10 mbar /
-1
7.5 Torr), the total evacuation time can be reduced by as much as 50%. 10
0 200 400 600
The graph below shows data for a 2.8 m3 / 100 ft3 chamber, with a s
2600 m3h-1 / 2600 ft3min-1 mechanical booster pump and a A With backing pump and EH mechanical booster pump switched on together
255 m3h-1 / 150 ft3min-1 backing pump. B With mechanical booster pump switched on at 5 mbar
C With backing pump only (pumping through booster pump)
Pa mbar
5 3
10 10
Automatic overload protection The hydrokinetic drive automatically
varies the rotational speed of the pump. This protects the motor from
overload, prevents over-heating, and allows the pump to operate with high
4 2
10 10
pressure differentials. Consequently, EH booster pumps are not damaged
C
by sudden increases of inlet pressure and even by the entry of solid debris
into the pump.
10
3
10
1 Important cost savings When you use EH mechanical booster pumps,
you save money on installation and operation. Your capital costs are
reduced as you do not need valves, by-pass lines and pressure switches,
A
and you can use a smaller backing pump than with conventional drive
2 0
10 10
booster pumps. Operation costs are reduced because EH booster pumps
B
have smaller motors than direct drive pumps and, when operating at full
speed, they use only a fraction of the rated power.
1 -1
10 10
0 200 400 600
s
2 Depends on pressure.
TECHNICAL DATA
Rotational speed2
50 Hz supply 0 – 2900 rpm
60 Hz supply 0 – 3500 rpm
Operating continuous inlet pressure 0 – 1000 mbar (0 – 760 Torr)
Maximum outlet pressure 1000 mbar (760 Torr)
Recommended backing pumps GV160, GV250,
E2M80, E2M175
Electrical supply voltage, 3-phase
50Hz 220 – 240 V / 380 – 415 V
60 Hz 208 – 230 V / 460 V
Motor power
Hydrocarbon 3 kW (4 hp)
PFPE 3 kW (4 hp)
ATEX 3 kW
Explosion proof 4 hp
Ambient temperature range
Operating 5 to 40 °C (40 to 104 °F)
Storage -10 to 80 °C (14 to 176 °F)
Maximum operating humidity 90% RH
Recommended cooling water flow 120 l h-1 (0.53 gal min-1)
(inlet temperature 20 °C)**
Recommended cooling water supply 2 – 6 bar
pressure**
Cooling water connections** £/8 inch BSP male
Recommended oil
Standard version Ultragrade 20
PFPE version Fomblin® YVAC 16/6
Oil capacity
Gear case 1.25 liter (1.3 qt)
Coupling cover 2.4 liter (2.5 qt)
Shaft seal reservoir 0.125 liter (0.25 qt)
Weight 149 kg (329 lb)
11 Under many circumstances, pumps may operate without cooling water. Apply to BOC Edwards for
more information.
2 Depends on pressure.
ORDERING INFORMATION
9 PRODUCT DESCRIPTION ORDERING NUMBER
PAGE EH1200 Industrial
64
EH1200IND 220-240 V or 380-415 V, 3-ph, 50 Hz, 3 kW A30590935
EH1200IND 200 V, 3-ph, 50 Hz, 3 kW NRC218000
EH1200IND 208-230 V or 460 V, 3-ph, 60 Hz, 4 hp A30591936
EH1200IND 200 V, 3-ph, 60 Hz, 4 hp NRC217000
EH1200 PFPE*
EH1200FX 220-240 V or 380-415 V, 3-ph, 50 Hz, 3 kW A30592935
EH1200FX 208-230 V or 460 V, 3-ph, 60 Hz, 4 hp A30593936
EH1200 Chemical**
EH1200C 230 V or 460 V, 3-ph, 60 Hz, 4 hp A30556982
EH1200T160 380-415 V, 3-ph, 50 Hz, 3 kW A30557900
* BOC Edwards does not recommend continuous running of PFPE boosters at >10 mbar.
** Chemical boosters may be supplied with ATEX classification either as part of a pump system or stand-
alone, on application. Please consult BOC Edwards.
2 Depends on pressure.
Fit the OLM500 in place of the oil sight-glass on the EH250 and EH500 oil
seal reservoirs, and on the EH1200, EH2600 and EH4200 oil seal
reservoirs and gear boxes. The OLM500 provides a switched output for
remote activation or warning devices. Technical data: 24 V a.c. or d.c.,
maximum current 0.5 A.
ORDERING INFORMATION
PRODUCT DESCRIPTION ORDERING NUMBER
OLM500 oil level monitor* A50434000
* Not suitable for ATEX boosters
ORDERING INFORMATION
PRODUCT DESCRIPTION ORDERING NUMBER
Inlet seal with mesh screen
ISO63 C10521085
ISO100 C10523085
ISO160 C10524085
9
PAGE