MAINTENANCE MANUAL
Electric rotating machines have dangerous parts: when operating, they have live and rotating components. Therefore:
- improper use
- the removal of protective covers and the disconnection of protection devices
- inadequate inspection and maintenance
can result in severe personal injury or property damage.
The person responsible for safety must therefore ensure that the machine is transported, installed, operated, maintained and repaired by
qualified personnel only, that must have:
- specific training and experience
- knowledge of applicable standards and laws
- knowledge of the general safety regulations, national and local codes and plant requirements
- the skill to recognize and avoid possible danger.
All maintenance and inspection operations must be carried out only with the authorization of the person responsible for safety, with the
machine at a standstill, disconnected from the supply (including auxiliary circuits such as the anti-condensation heaters).
As the electric machine is a product to be installed in industrial areas, additional protection measures must be taken and assured by the
person responsible for the installation, if stricter protection conditions are required.
As the electric generator is a component to be coupled to another machine, it is the responsibility of the installing engineer to ensure, during
operation, proper protection against the risk of contact with bare rotating parts and to prevent people or things from approaching the
machine.
If the machine shows deviations from the normal performance (excessive or too low voltage, increase in temperature, noise and vibrations)
Here enclosed with the “instructions manual” there are self-adhesive leaflets which are reporting symbols for security: the self-adhesive
leaflets are to be applied to the generator surface, at the customer’s charge, according the instruction presented on the sheet of the
self-adhesive.
CONTENTS
1. INTRODUCTION
1.1 Standard 1.2 Generator Designation
1.3 Products Serial-number Position 1.4 Rating Plate
2. GENERATOR APPLICATION
2.1 Operating Environment 2.2 De-rating Table
3. GENERATOR PRINCIPLES
3.1 Self-excited Generators with AVR Control 3.2 PMG Excited Generators with AVR Control
3.3 Other Description of the AVR
5. INSTALLATION
5.1 Lifting 5.2 Operating Conditions
5.3 Installation 5.4 Direction of Rotation
5.5 Electrical Connection 5.6 Protection
7. MAINTENANCE
7.1 General Maintenance 7.2 Inspection and Maintenance
7.3 Assembling and Disassembling 7.4 Troubleshooting
7.5 AVR Troubleshooting
10. SERVICE
1. INTRODUCTION
The instructions refer to three-phase synchronous generators series TCU. Technical data and constructive details are given in the catalogue.
In order to obtain the proper working of the generator it is necessary to read carefully all included instructions.
1.1. Standard
The generators TCU are synchronous generators, brushless type, self excited and self regulated, manufactured according to the standards
and in compliance to IEC34-1; EN60034-1; GB755; VDE 0530; BS5000 and NEMA MG21.
EvoTec is well recognized in Europe, Middle East, Africa and Asian continents as the leading supplier to the industrial, petrochemical, marine,
on-shore and off-shore and any places where dependable electrical power is highly needed.
Frequency
The generators are suitable for operation at 50Hz and 60Hz, according to the data reported on the name-plate: for correct operation for 50Hz
and 60Hz, it is necessary to verify that the settings of the voltage regulator are proper for the required operation and that the use of the
generator is in accordance with the value of the name-plate.
Accessories
According to the customer’s order the generators can be equipped with accessories, such as anti-condensation heaters, thermistors, etc.
2. GENERATOR APPLICATION
1
EXPANTANCY OF THE MACHINES
2.2. De-rating table
Following de-rating table must be considered if generator needs to be operated under conditions below :
Altitude(m.a.s.l) Revise coefficient Temperature(ºC) Revise coefficient
1500 0.97 45 0.97
2000 0.94 50 0.94
2500 0.91 55 0.91
Operating attitude and temperature above the standard, revise coefficient should be calculated together.
All the generator ratings are specified in the rating-plate. The manufacturer holds no responsibility if
any damage occurred to the machine caused by misuse.
3. GENERATOR PRINCIPLES
The ETC-1(ETC-2)AVR senses average voltage on two phases ensuring close regulation. In addition, it detects engine speed and provides
voltage fall off with speed, below a pre-selected speed (Hz) setting, preventing over-excitation at low engine speeds and soften the effect of
load switching to relieve the burden on the engine. The detailed function of the AVR circuits and their adjustment are covered in the load
testing section.
2
3.2. PMG Excited Generators with AVR Control
The Permanent Magnet Generator (PMG) provides power for the excitation of the exciter field via the AVR which is the controlling device
governing the level of excitation provided to the exciter field. The AVR responds to a voltage-sensing signal derived, via an isolating
transformer, from the main stator winding. By controlling the low power of the exciter field, control of the high power requirement of the main
field is achieved through the rectified output of the exciter armature.
ETC-2 and ETC-3 AVR provides the function of paralleling. ETC-1, ETC-2 and ETC-3 AVR provides the function of short-circuit current limit
control. ETC-3 AVR is used for PMG excitation system.
3
4. THE ESSENTIAL COMPONENTS OF GENERATOR
4
Figure 4 The wiring diagram of AVR ETC-N0/N1 (ETC-1/0A) in 400Vac system
5
The wiring diagram of AVR ETC-N2(ETC-2) in 400Vac system (Figure 5)
6
Figure 5 The wiring diagram of AVR ETC-N2(ETC-2) in 400Vac system
The wiring diagram of AVR ETC-N3(ETC-3) with PMG in 400Vac system (Figure 6)
7
8
Figure 6 The wiring diagram of AVR ETC-N3(ETC-3) with PMG in 400Vac system
Parallel Requirements
When it is required to operate the regulator in parallel with an isolated or utility bus, in addition to the regulator provisions, a 5 VA current
transformer (CT) is required (see Figure 5 & 6). This CT is connected in a generator W line and should deliver from S1 to S2 amperes
secondary current at rated load. The phase relationship of CT signal to the regulator sensing voltage must be correct or the system will not
parallel properly. The CT device need to be supplied by customer self. Figure 5 & 6 show the correct CT polarity for A-B-C phase rotation
sequence. If the phase rotation sequence is A-C-B, the CT’s secondary leads must be interchanged.
Voltage Adjustment
The voltage adjustment possibility depends on the characteristics of the generator. Normally the internal potentiometer VOLT allows
possibility of adjusting the voltage from the control panel, or in order to limit the voltage range, an external potentiometer can connect a finer
possibility of voltage to the terminal “R1” and “R2” (minimum 1 Watt, resistance 1KΩ).
Stability
The STABILITY control potentiometer is pre-set and should not normally require adjustment. If adjustment is necessary proceed as follow:
Run the generating set on no-load and check that speed is correct and stable.
Turn the STABILITY control potentiometer anti-clockwise to the end, and then turn slowly clockwise until the generator voltage
starts to become unstable. The correct setting is slightly anti-clockwise from this position (i.e. where the machine volts are stable
but close to the unstable region).
9
Figure 7
The AVR incorporates an under-speed protection circuit which gives a voltage/speed (Hz) characteristic as shown (Figure 7): The UFRO
control potentiometer sets the “knee point”.
[2] Adjustment Method :Clockwise adjustment lowers the frequency setting of the “knee point” and extinguishes the LED. For Optimum
setting the LED should illuminate as the frequency falls just below nominal frequency, i.e.47Hz on a 50Hz generator or 57HZ on a 60HZ
generator.
Droop
The device is included in the voltage, to allow parallel operation between similar generators: the device permits to share correctly the total
reactive required by the load among all generators operating in parallel. The device is composed by an external CT (which is sensing the
current in phase U) and by a “droop” circuit internal in the regulator. The voltage regulator is provided with input terminals(terminals S1 and
S2)for easy connection to CT. Such terminals are normally short circuit by a connection, when the generator is used in single operation. If the
voltage is increase as load increases, It is necessary to reverse the leads of current transformer at terminals S1-S2.
Excitation Tripping
An AVR supplied from a permanent magnet generator inherently delivers maximum excitation power on a line to line or line to neutral short
circuit. In order to protect the generator windings, the AVR incorporates an over excitation circuit. When it detects high excitation after a
pre-determined time (8-10 seconds), the excitation will be cut-off. Symptoms of incorrect setting are the generator output collapses on load
10
5. INSTALLATION
5.1. Lifting
When moving the generator, always keep it in the horizontal position. The generator lifting points are designed to lift the generator only. Do
not lift the complete generating set by the generator lifting points.
It is also important to have a good airflow position, away from any hot or exhaust system. It is also recommended that if the generator were
to install in an area with high condensation, a space heater shall be added as an extra protection. If installed in an area of heavy laden of fine
dust or sand, an inlet air filter shall be added on but due to these, a certain output deration is required.
5.3. Installation
During assembling of the generator and the engine, it is important to have a solid and rigid base-frame to ensure no frame deformation or
frame twisting arises. We recommended to use Grade 8.8 bolts and nuts to assemble the generator set and to also make sure the base-frame
is sitting firmly to the ground surface.
During installation, it is also important not to harm the bearing and shall always keep the rotor assembly in alignment. During the lifting of the
generator, it is important to ensure the lifting slings or wires rope are in good condition and also ensure the lifting block are able to sustain the
generator weight. We recommended the lifting method shown above.
11
supplied.
dismantle the flange cover, position the generator in-line with the engine and then aligned the generator flange to the engine
housing. After that, align the generator coupling to the engine flywheel. This is to make sure all the surface is vertically in-line with
each other. Should it is not aligned, it can be adjusted by adding several shim to the base-frame.
bolt the coupling disc to the flywheel housing using recommended number of bolts and size. We recommended to use Grade 8.8 or
above bolt type.
it is recommended to turn the rotor to check there is no touching between the rotor and the stator assembly.
after assembling the generator footing to the base-frame, install back the flange cover.
voltage requested. The output cables have to be fixed to the terminal board as indicated in Figure 9.
12
L1 T1
L1 T1 T7
SERIESS STAR T4 PARALLEL STAR
T7
T4 T10
LEA D V T10 LEA D V T12 T5
T12 T11
L1-L2 -L3 400 T9 T8 L1-L2 -L3 20 0 T9 T2
T6 T5
L1 L2 400 L3 T3 T2 L1 L2 20 0 T6 T11
L3 T3 T8
L1 L3 400 N L2 L1 L3 20 0 L2
N
L2 L3 400 4 7 5 8 6 9 L2 L3 20 0 8 4 6
7 9 5
L1 N 230 L1 N 11 5
L2 N 230 10 12
L2 N 11 5
10 11
L3 N 230 1 2 3 11 L3 N 11 5 1 2 3 12
400VOLT.3PHAES L1 L2 L3 200VOLT.3PHASE L1 L2 L3
230VOLT.1 PHASE U V W N 115VOLT.1 PHASE U V W N
L1
PARALLEL DELTA
DOUBLE DELTA T11 T9
T5
T3
T6 T1 T8 T12 T6
T12 T2
T3 T7 T4
T9 T10 T7 T4 T1
LEA D V T10
T11 T8
L1-L2 -L3 115 L3 L2 LEA D V N
L1 L2 23 0 L2 L1
L1 L2 115 T5 T2
L1 L3 115 6 7 4 8 5 9 L1 N 11 5 6 5 9 11 4 7
L2 L3 115 L2 N 11 5
1 3 8 10 2 12
1 12 2 10 3 11
115VOLT.3PHASE L1 L2 L3 L1 L2
115VOLT.1 PHASE U V W 115/230VOLT.1 PHASE U W N
L1
T1
STAR L1
SERIES DELTA T12
T1
T9
T4 LEAD V T4
LEAD V N
T6 T7
L1-L2-L3 400 T6 T5
T3 T2
L1-L2-L3 230 L1 L2 400 L3
T10
L1 L2 230 L3
T3
L1 L3 L2
L2 400 N
L1 L3 230 T11 T8 T5 T2 L2 L3 400
L2 L3 230 L1 N 230 4 5 6
L1 N 115 4 7 5 8 6 9 L2 N 230
L2 N 115 L3 N 230
1 2 3
1 12 2 10 3 11
230VOLT.3PHASE L1 L2 L3 400VOLT.3PHASE
L1 L2 L3
115/230VOLT.1 PHASE U V W N 230VOLT.1 PHASE U V W N
1 PHASE ZIG- L1
DELTA
ZAG T5
T11
T9
T6 T1
T2 T3 T12 LEAD V T4
T4 T1 T3
T8 T6 L1-L2-L3 230 L3 L2
LEAD V N T10 T7 L1 L2 230 T5 T2
L1 L2 230 L2 L1 L1 L3 230
L1 N 115 L2 L3 230 6 4 5
7 8 5 9 4 6
L2 N 115
1 2 3
1 2 3 11 10 12
230VOLT.3PHASE L1 L2 L1 L2 L3
230VOLT.3PHASE
115/230VOLT.1 PHASE N U V W
Figure 10
13
SERIESS STAR L1 T1 PARALLEL STAR L1 T1 T7
T4
LEAD V T7 LEAD V T4 T10
T10
L1-L2-L3 380 T12 T11 L1-L2-L3 190 T12 T5
T9 T8 T9 T2
L1 L2 380 T6 T5 L1 L2 190
T3 T2 T6 T11
L1 L3 380 L3 L1 L3 190 L3 T3
N T8
L2 L3 380 L2 L2 L3 190 N L2
L1 N 220 4 7 5 8 6 9 L1 N 110 4 6
7 8 9 5
L2 N 220 L2 N 110
L3 N 220 10 12 L3 N 110 10 11
1 2 3 11 1 2 3 12
380VOLT.3PHASE
220VOLT.1 PHASE L1 L2 L3 190VOLT.3PHASE L1 L2 L3
U V W N 110VOLT.1 PHASE U V W N
L1
PARALLEL DELTA
DOUBLE DELTA T11 T9
T5
T3
T6 T1 T8 T12 T6
T12 T2
T7 T4
T3
T9 T10 T7 T4 T1
LEAD V T10
L3 T11 T8
L1-L2-L3 110 L2 LEAD V N
L2 L1
L1 L2 110 T5 T2 L1 L2 220
L1 L3 110 6 7 4 8 5 9 L1 N 110 6 5 9 11 4 7
L2 L3 110 L2 N 110
1 3 2 12
1 12 2 10 3 11 8 10
110VOLT.3PHASE L1 L2 L3 L1 L2
110VOLT.1 PHASE U V W 110/220VOLT.1 PHASE U W N
L1 STAR L1
SERIES DELTA T12 T1
T1
T9 T4 LEAD V T4
LEAD V N
T6 T7
L1-L2-L3 380 T6 T5
T3 T2
L1-L2-L3 220 L1 L2 380 L3
T10
L1 L2 220 L3
T3 L2
L2 L1 L3 380 N
L1 L3 220 T11 T8 T5 T2 L2 L3 380
L2 L3 220 L1 N 220 4 5 6
L1 N 110 4 7 5 8 6 9 L2 N 220
L2 N 110 L3 N 220 1 2 3
1 12 2 10 3 11
220VOLT.3PHASE L1 L2 L3 380VOLT.3PHASE L1 L2 L3
110/220VOLT.1 PHASE 220VOLT.1 PHASE U V W N
U V W N
220VOLT.3PHASE L1 L2 220VOLT.3PHASE L1 L2 L3
110VOLT.1 PHASE N 220VOLT.1 PHASE U V W
Figure 11
5.6. Protection
The generator supplied neutral cable is not connected to the frame. Should it is required, it can be connected. Inside the terminal box, there
14
is an earth terminal provided. There is a possibility during the complete generator set in operation, over-speed, over-voltage, short-circuit and
other possibilities can be occurred. Reliable protections are required. If running on parallel operation, reverse power protection is also
required.
During operation, it is required to followed strictly to the local regulations, laws and technical standard in force
15
6.2. Pre-running Testing
All generators are fully tested at the factory prior to delivery. All generators are factory set at star series connection, 400V at 1500rpm.
No load adjustment
When the prime mover reaches the rated speed, the generator should have also reaches the rated voltage. If there is a difference in the
voltage level, it can be corrected by adjusting the AVR. All three-phase voltage should also be stable and balance.
Load adjustment
To ensure the generator is in good condition, applied the load by increasing and decreasing the load to check the voltage stability level, check
all the control panel metering is functioning in proper condition and also check on the generator of any abnormal condition. After the above
steps, the generator is safe to operate.
Please note that it is required to unplug the AVR when the prime mover is running at low speed for a long time, otherwise, it will damage the
AVR and the excitation windings.
6.3. Starting Up
- Make sure the switch, which is on the Generator set control panel, is off.
- Start up the engine, gradually increase to the rated speed. The acceleration process should not be too long.
NOTE: After the diesel generator set is installed, it cannot immediately add load for first use. Make sure it runs on NO LOAD for several hours.
Observe the situation and dehumidify and others. It can add load from 30%~50%~70% if it has been in a stable and reliable conditions. Each
load should run about 1 hour.
If no abnormal behaviour is discovered, test run can be conducted. It can be in a long-term operation if the temperature rise, vibration and etc.
are in good conditions during test run.
- Switch on, add load, run as normal.
7. MAINTENANCE
Improper setting of speed governor will result in rotating parts damage by over speed.
The generator will function in good condition if there is a routine maintenance and checking program. It is important to ensure safe and
trouble-free conditions throughout the operation period. It is recommended to follow every maintenance measures highlighted in this manual.
Generator should always be kept dry. In order to keep out of the humidity, please cover with cloth if not used.
Generator must be free from metal leftovers, drops, dust, acid-base steam or other harmful gases.
During operation, the ventilation must be sufficient. Please ensure all openings are free and not be block by any machinery or panel.
16
Do not put anything on top of the alternator for it is bad for ventilation and heat elimination. Please don't remove the top terminal
box cover.
Please check the generator load from time to time. The load current should not over the rated current of generator. When the load
power factor is low, the excitation current should not over the rated value mentioned on the nameplate. When the three-phase load
is not balance, the biggest phase current of that phase should not over the rated current.
Please note the temperature of the alternator bearing. The bearing temperature rise should not over 55K in general.
During operation, the generator shall not over the rated speed, voltage and ampere. Once abnormal smells, strange sound audible
and excessive vibration detected, please stop the machine immediately and a thorough check-up is required before restart the
machine.
- If the generator is not in use for some time, check the windings insulation. If it is lower than 5Mohm, then it is necessary to dry the
generator and then repeat the test. If the grounding insulation still remains the same, then the insulation has already aged and
you should change the wire and insulation.
- Check the bearing and housing position to ensure there is no loose or wear and tear.
- check the airflow and internal condition. If inside the terminal box is too dusty, its required to be cleaned.
- Check the alignment of the generator to the engine to make sure it is not out of alignment and also check the fan assembly to
ensure it is not deform.
- Check all cable connections especially the AVR side to make sure it is not loose.
Bearing checking
There are two types of bearing in generator:
a) Pre-lubricated sealed for life bearing which do not need to lubricate again.
b) Lubricable bearing which need to lubricate periodically during the operation procedure.
Generator Range Bearing position Lubrication weight (g) Lubrication cycle (hour)
The lubrication cycle above is in the condition of operation temperature below 70°C. Each 15°C temperature rise will decrease half lubrication
cycle.
17
- for double bearing generator, take off the outer bearing cover of the front bearing, take out the bolt of the front shied, then lifting
out the rotor from the stator with professional lifting device.
- for the large capacity generator with very heavy rotor, using professional lifting device as Figure 12.
- Generator to engine not in-line - Check the alignment and rectify the problem
Vibration - Rotor balancing problem after repair - Rebalancing required
- Bearing damage - Check and change bearing immediately
- Engine problem - Check and service the engine
- Operation exceed bearing recommended - Change bearing
Bearing heating running hours - Change bearing or lubricate grease
- Insufficient of grease - Check the alignment and rectify the problem
- Generator to engine not in-line
- Overload - Adjust to the nominal rate
Generator heating - Power factor too low - Adjust the load and the ampere to nominal level
- Airflow problem - Ensure the fan assembly not obstruct
Voltage unstable - AVR problem - Check, adjust or change a new AVR
18
7.5. AVR Troubleshooting
Trouble Possible cause Measures
- Insufficient of residual voltage - Apply 12V battery to recharge
- Sensing cable not connected - Reconnect again
No power supply
- Generator set under-speed - Adjust to rated speed
- AVR damage - Change new AVR
Voltage fluctuation between - generator set speed too low - Adjust generator set speed
300V~400V - Wrong FREQ setting - Adjust the setting
After the generator set is arrival, customer should check if it is accordance with the order by the rating-plate. Meanwhile, check if there is any
Documents with the goods include Maintenance Manual, Certificate of Quality, Structural Drawing, Products List, Contract and etc.
For lifting and handling the purpose made eyebolts must be used. The lifting eyes are designed to support only the
weight of the generator and they are not to be used for lifting the complete gen-set that incorporates the generator. Check that the lifting
means available are suitable for the movement of all parts which have to be handled. Check also that the working conditions are suitable to
If the generator is not used immediately, customer should pack it again. And put it in a dry and clean surrounding free of contaminations such
as gases and various chemicals, salt water spray, dust and rainfall. Keep the generator alignment in delivery and upright in storage. It is not
19
10. SERVICE
Service engineers of the company are available to give technical support and advice.
20
Anhui EvoTec Power Generation Co., Ltd
No.9, Su He Road, Lujiang Economic Development Zone,