HON-FIN4000xxK-10K - User Guide V1.3 (EN)
HON-FIN4000xxK-10K - User Guide V1.3 (EN)
HON-FIN4000xxK-10K - User Guide V1.3 (EN)
HON-FIN4000xxK-10K
Honeywell
15:02:55
(1/5000) U
V1.3
This manual is provided for information purpose only. All information included
herein is subject to change without notice. Honeywell is not responsible for any
changes, direct or indirect, arising from or related to us of this manual.
2
Contents
4
Safety Instructions
Installation
In Use
5
1. Before Use
1.1 Components
6
1.2 Body HON-FIN4000xxK-10K
LCD Display
Key Pad
LED Lamp
7
1.3 Methods for Fingerprint Input
HON-FIN4000xxK-10K can easily recognize fingerprints even though the
angle and location of the pattern change. However, it is recommended to
properly input fingerprints for more precise recognition.
When enrolling your fingerprint, the first finger input window prompts.
Then register the desired finger on the terminal as shown in the figure
below.
When the re-entry window appears with a “tick” sound, re-enter the
previously enrolled finger. The fingerprint input is made twice.
(Gently push your finger on the sensor to have a full fingerprint.)
8
HON-FIN4000xxK-10K
9
1.4 System Setup Procedure
Register users
Step 5 - Use the system after user registration (see 2.1).
10
1.4.1 Registering the Initial Administrator
HON-FIN4000xxK-10K
There is no administrator set for the product in the initial status. So register an
administrator to manage the device.
Enroll
Completed
11
1.4.2 Network Configuration
The network configuration is required to connect HON-FIN4000-SW or other devices
via network. Configure the settings according to the communication environment in your
place.
2. Configure the settings for TCP/IP port and server according to the installation
environment.
※ The following example explains how to directly connect the server PC without
using DHCP.
Item
TCP/IP
Device In/Out In/Out
Use ◀ /▶ buttons to set Enter the IP address Enter the Gateway using
whether or not to use and press OK. numeric and arrow
DHCP and press OK. buttons and press OK.
12
100Base-T support HON-FIN4000xxK-10K
When you exit from the menu before completing the TCP/IP
setting, the data is not stored so please finish the remaining
steps until the setting completion message appears.
13
[In case of configuring the network via RS-485]
1. Connect the terminal to the computer that has HON-FIN4000-SW.
Item
Serial Conn.
Baudrate Termination
115200 Not Use Completed
Serial Conn. Serial Conn.
14
1.5 Authorization Methods HON-FIN4000xxK-10K
For changing the terminal authorization method, see the operation mode selection case
in “4.1 Authorization”.
To separately set the authorization method for each user, see “2.2 Editing a user”.
1. Fingerprint recognition
2. Fingerprint recognition after entering ID
3. Fingerprint recognition after identifying user card
Fingerprint recognition
Enter ID
Honeywell
2
10:33:02
Access Granted
ID : 2
The authentication
result will appear.
15
Fingerprint recognition after identifying user card
Honeywell
10:33:02
Access Granted
ID : 2
The authentication
result will appear.
1. Fingerprint recognition
2. Fingerprint recognition after entering ID
3. Password entry after entering ID
4. Fingerprint recognition after identifying the user card
5. PIN entry after identifying the user card
Fingerprint recognition
16
Fingerprint recognition after entering ID
HON-FIN4000xxK-10K
Enter ID
Honeywell
2
10:33:02
The authentication
result will appear.
Honeywell
10:33:02
The authentication
result will appear.
17
PIN entry after identifying the user card
Access Granted
ID : 2
The authentication
result will appear.
18
1.5.3 Finger and PIN
HON-FIN4000xxK-10K
When the user authorization method is set to “Finger and PIN,” you can authenticate
using three different methods:
Enter PIN
Honeywell ****
10:33:02
Input the fingerprint Enter the password
of the user. of the user and
press OK.
Access Granted
ID : 2
The authentication
result will appear.
Enter ID
Honeywell
2
10:33:02
Enter PIN
Access Granted
****
ID : 2
19
PIN entry after entering user card and fingerprint
Honeywell
10:33:02
Enter PIN
Access Granted
****
ID : 2
Access Granted
ID : 2
The authentication
result will appear.
20
HON-FIN4000xxK-10K
Access Granted
ID : 2
The authentication
Place the user card on result will appear.
the Honeywell logo.
21
2. User Management
The user management and other environment settings can be updated after authorizing
the registered administrator (see 1.4.1 “Registering the Initial Administrator”).
User
Enroll
22
5. Use ◀ /▶ buttons to select a card ID entry type Card
and press OK. Not Use
※Not Use/Read Card/Manual Input/User ID Enroll
terminal.
- Manual Input: The card ID (maximum 10 digits) must be directly entered.
- User ID: The selected User ID is used as Card ID (Card ID=User ID)
Card ID
Card
2691057484
Read Card Place the Card Facility Code
Enroll 0
Use ◀ /▶ buttons to Directly enter the card Enter the Facility Code.
select Manual Input ID through the keypad.
and press OK.
23
7. Enter the finger or PIN depending on the operation mode.
st st nd
(Password: 4–8 digit number, Fingerprint: 1 finger or 1 + 2 fingers)
Place the first finger Place the same finger Place the second
on the sensor. on the sensor again. finger in the same
manner.
※In order to skip the second fingerprint enrollment after enrolling the first
fingerprint, press ESC.
※The user can enroll one or two fingerprints.
24
2.1.2 Registration on a Card
The information of a new user can be saved on a card.
User HON-FIN4000xxK-10K
Enroll
25
6. Use ◀ /▶ button to select Card Type and press
Card Type
OK.
Bypass Card
※Bypass Card/Use Template
Enroll
Card Type
Enroll
When the user enrollment
Use ◀ /▶ buttons to Place the user card on
is successfully done,
select Bypass Card the divice’s logo area.
the completion message
and press OK. window appears.
※In case of Mifare card, the 1K card can save up to 2 fingerprint data but the 4K
card up to 4. The card layout information can be set using the PC software.
26
2.2 Editing a User
You can modify the data of the previously enrolled user.
User HON-FIN4000xxK-10K
Edit
Edit
Item Level
Level General
Edit Edit
※The settings for user, screen/sound, device, and such can be configured
only by the administrator level.
27
Changing the authorization method
Edit Edit
This authorization method setting for each user has higher priority than
the terminal setting that has been defined in Device > Authorization
> Operation Mode > Auth Mode. Note that this function is applied to
the case when the user enters ID or card and when Use is set in
Device > Authorization > Operation Mode > Private Auth Mode.
Edit Edit
28
Changing the fingerprint of the user
Item
Fingerprint Place the first Place the first
finger finger again
Edit
Use ◀ /▶ buttons to Place the first finger on Place the same finger
select Fingerprint and the sensor. on the sensor again.
press OK.
HON-FIN4000xxK-10K
Place the second
finger
Enroll the second fingerprint
(Skip=ESC) in the same manner.
Item Card
Card Read Card
Edit Edit
29
2.3 Deleting a User
You can delete unnecessary user data.
User
Delete
Delete
- If all the users including the administrator are deleted, you must
register the initial administrator again (see 1.4.1).
- When an administrator is deleted by mistake except normal users,
the initial administrator registration step does not require registering
normal users.
30
3. Configuration for Screen and
Sound
3.1 Date, Time
You need to set the current system date and time.
After setting the date and time, the log data can store correct information.
HON-FIN4000xxK-10K
Date, Time
31
3.2 Backlight
1. Use ◀ /▶ buttons to select the Screen, Sound
( ) icon and press OK.
Screen, Sound
Backlight
All On At Use
※ When no input is made
on the menu window, it
Mode Timeout(sec) sets the time to
automatically turn off the
All On At Use 20
LCD/Keypad backlight.
Backlight Backlight
Mode Timeout(sec)
Always On 20
32
On at Use ※When no input is made on the menu window, it sets
the time to automatically turn off the backlight.
Mode Timeout(sec)
On at Use 20
Backlight Backlight
HON-FIN4000xxK-10K
33
3.3 Sound
Sound
3. Use ◀ /▶ buttons to select the sound operation status and press OK.
Mode Mode
Off Or On
Sound Sound
34
4. Device Configuration
4.1 Authorization
1. Use ◀ /▶ buttons to select the Device ( ) icon
and press OK.
Device
Authorization
Authorization
In case of Fingerprint
HON-FIN4000xxK-10K
Fingerprint Fingerprint
Cont.
35
Item Sensitivity
Sensitivity 7
Fingerprint Fingerprint
Fingerprint Fingerprint
Cont.
36
Item Template Type
Template Type HON-FIN4000
Fingerprint Fingerprint
※ Security Level: The higher the security level, the more sensitive the fingerprint
recognition. But the authorization failure rate can increase.
※ Image Quality: It is the image quality level used when entering the fingerprint data.
In case of Low, the fingerprint can be easily input but the correct
authorization is not guaranteed.
※ Sensitivity: The higher the value, the more sensitive the sensor.
※ Check Duplicate: When enrolling a user, it determines whether or not to check the
fingerprint data is already enrolled.
※ Fast Mode: You can set the fingerprint recognition speed. If it is set to Fast,
the recognition accuracy may decrease.
※ Scan Timeout: You can set the terminal standby time for entering fingerprint.
If entry is not made within the specified time, the message,
‘Entry time is over” appears.
※ Matching Timeout: You can set the maximum authorization time after entering fingerprint.
If this time limit expires, matching stops and the authorization fails.
※ Template Type: Format used in the terminal when identifying fingerprints (HON-FIN4000/SIF)
- HON-FIN4000: HON-FIN4000’s own template format, SIF: ISO/IEC compatible template format
(To change the template format, there must be no fingerprint data stored on the terminal.) HON-FIN4000xxK-10K
37
In case of Operation Mode
Cont.
38
Item Private Auth Mode
Private Auth Mode Use
Operation Mode Operation Mode
39
4.2 In/Out
1. Use ◀ /▶ buttons to select the Device ( ) icon
and press OK.
Device
In case of Tamper On
Item Tamper On
Tamper On Ignore
In/Out In/Out
Use ◀ /▶ buttons to Use ◀ /▶ buttons Press OK.
select Tamper On and to select a tamper
press OK. method.
※ Tamper: *Ignore/Locked
- Locked: When the device is forcibly removed, the Device is locked.
(To release the lock, the administrator must perform authorization.)
40
In case of Wiegand
※Standard 26Bit Format is used for Wiegand In/Out format. The setting
can be changed using HON-FIN4000-SW.
Item Type
Wiegand Card ID In
In/Out Wiegand
Use ◀ /▶ buttons to Use ◀/▶ buttons to select
select Wiegand and Wiegand and press OK.
press OK. *Card ID In/ Card ID Out/User ID
In/ User ID Out/Not Use
41
※It directly connects to the server for HON-FIN4000-
In case of TCP/IP
SW without using DHCP.
Enter Gateway using Enter IP address using Enter Port and press
numeric and arrow numeric and arrow OK.
button and press OK. button and press OK.
100Base-T Support
Not Support
When you exit before
Completed
finishing the TCP/IP
TCP/IP setting, the change is
not stored so proceed
Use ◀ /▶ buttons to set The completion with the settings until
whether or not to message window
the message
support 100Base-T and appears.
press OK.
“Completed” appears.
42
4.3 System
1. Use ◀ /▶ buttons to select the Device ( ) icon
and press OK.
Device
System
In case of Information
Item
Use ◀ /▶ buttons to
Log select Log and press OK.
Information
Set Time
Not Use
6/18 14:20(3)
Log Delete OK
Use ◀ /▶ buttons to The entire logs appear.
select Not Use and (Use ◀ /▶ buttons to see
press OK. the previous/next logs.)
43
In case of Information — Continued
Item User
4/5000
Num. Of User Templates
Information 6/10000
Information Information
Information Information
Item Initialize?
※In case of Initialize, the settings are deleted but the log data and user DB are not
deleted.
44
In case of Delete All Log
Item Delete?
※In this case, all users’ in/out data are deleted and they cannot be recovered.
Item Delete?
※In this case, the users’ DB is completely deleted so you must immediately
register the initial administrator (see 1.4.1).
※When the user DB is deleted, it cannot be recovered.
In case of Language
Item Item
Language English
System Language
Use ◀ /▶ buttons to Use ◀ /▶ buttons Press OK.
select Language and to select the
press OK. language.
* English/ Chinese
45
In case of Wallpaper
Item Wallpaper
Wallpaper Type1
System System
Honeywell
Honeywell
10:33:02
10:33:02 (8/5000) U
Type1 Type2
Characters on the Type2 wallpaper
- U: Unlinked (LAN is not connected.)
- D: Disconnected (LAN is connected but TCP/IP communication is not active.)
- C: Connected (LAN is connected and TCP/IP communication is active.)
In case of Contrast
Item Contrast ※Contrast
Contrast value on the
Contrast 17
screen (Range: 10 to 30)
System System
Item
Format Card
Format Card Place the Card
Completed
System
※ After formatting a card, the data on a rewritable card such as Mifare card
is removed. (The card format can be set using HON-FIN4000-SW.)
46
5. Attendance Management
5.1 Operating environment
When a T&A event (attendance, leaving, return, and outside duty) occurs on the
terminal, it will be saved within its internal DB.
HON-FIN4000-SW can define/modify T&A events and input them into the device.
Event
HON-FIN4000-SW HON-FIN4000xxK-10K
HON-FIN4000xxK-10K
47
5.2 Setup for attendance management
Attendance Mgmt
you can select the attendance status. When a user authorization is successful,
the selected attendance log is recorded.
- Fixed: A specific attendance status continues. When a user authorization is successful,
the corresponding log is recorded.
- Manual: The active attendance status appears on the screen and it can be changed
using ◀/▶ buttons. Once it is changed, the status continues until another
selection is made. Every authorization success makes the log recorded.
- Auto: The active attendance status appears on the screen. Fore each time zone,
the active attendance statuses are fixed.
- Not Use: The function is not available.
48
5.3 Operation modes
Select
Honeywell In
10:33:02 Type
Successful T&A
Authentication
Message
HON-FIN4000xxK-10K
5.3.2 Manual
When the operation mode is set to “Manual”, this mode is used.
In case of Manual
In
Honeywell 08:30:43
10:33:02 12/01/2008
49
In case of Manual
In
ID: 8
08:30:43
In
12/01/2008
Successful T&A
Authentication
Message
The Users identify the card
or fingerprint according to
the authorization method.
5.3.2 Auto
When the operation mode is set to “Auto,” this mode is used.
This mode can set the corresponding time zone for each attendance event through
HON-FIN4000-SW. Then the fixed event is set for the corresponding time zone.
In case of Auto
Out
ID: 8
18:35:55
Attendance Mgmt
Out
12/01/2008
※Aut o: While the event type and time zone are set through HON-FIN4000-SW, you
can totally use this mode for all the users who are entering or leaving.
50
5.3.3 Fixed
When the operation mode is set to “Fixed,” this mode is used.
This mode is used after fixing the event through HON-FIN4000-SW if required.
In this case, the setting can be changed only through HON-FIN4000-SW and you
cannot change the attendance event through the terminal.
Out
ID: 8
18:35:55
Out
12/01/2008
※ Fixed: This mode is available only when the desired event is set for all the users
who are entering or leaving.
HON-FIN4000xxK-10K
51
6. FAQ
6.1 Error messages
Error Message Description
!Cannot Change A template already exists when you want to change the template format.
!Cannot Format The card is not formatted due to improper card touch.
!Cannot Write The user information is not saved due to improper card touch.
!Device Locked The device is locked because the case has been open.
When enrolling a user fingerprint, the fingerprint that has been input
!Duplicate Finger
already exists in the device (when checking the duplicated case).
!Failed The number of users exceeds 5000, so you cannot enroll more users.
The fingerprint authentication for the administrator fails when entering the
!Not Authorized
menu.
!Not Recognizable The fingerprint data cannot be extracted due to wrong finger input.
!Time Out The fingerprint data is not entered while the sensor is active.
!Unknown ID The user ID that does not exist in the device is entered.
!Wrong PIN The entered password for authentication is not matched the enrolled one.
52
6.2 Troubleshooting
Category Trouble Solution
The power is - When the device is disconnected from the bracket, it
supplied but the may not work when using the tamper switch.
Power device does not - Check the adapter or power cable.
operate.
The password is lost. - Enter the queried password after contacting the
administrator in case of a normal user.
Password - When the administrator password is lost, contact with the
installation agency.
The fingerprint has - HON-FIN4000xxK-10K has the technology of Honeywell
been enrolled but its that won the first award in FVC2004 and FVC2006
recognition because it has world number one quality in recognition.
encounters an error. - For better performance in fingerprint recognition, correct
registration is a must.
- Enroll the fingerprint again after seeing
“1.4 Methods for Fingerprint Input”
- The recognition rate may vary due to the characteristic of
Fingerprint each finger so enroll the fingerprint of another finger.
It was good at - Check whether the finger or the sensor is covered with
recognizing sweat, moisture, or dust.
fingerprints but - In case the fingerprint has any damage, the device may
suddenly it fails in consider it as the one of wrong person.
recognition. - Wipe the finger or sensor with a dry cloth and retry.
- When the fingerprint is so dry, blow your steam of breath
into it and retry.
The time is not - HON-FIN4000xxK-10K has an embedded battery but it
correct. can be discharged by a long time use. Accordingly the
Time time may not be correct. Correct the time after seeing
“3.1 Date, Time.”
The terminal data is - Check the connection status after setting on the terminal
not found by HON- like Terminal > System > Wallpaper > Type2.
FIN4000-SW. - When U is displayed: Check the LAN connection status.
- When D is displayed: Check the IP address. If you set
TCP/IP like Terminal > In/Out -> TCP/IP -> DHCP Not Use, the
current IP address appears. If you use DHCP, the actual
address received from the DHCP server appears. If the
IP address is set correctly, check the port number. HON-FIN4000xxK-10K
53
6.3 Usage summary
※ It provides the mainly used functions.
※ button: Used to select the desired function.
54
6.4 System Installation
6.4.1 Cable specifications
HON-FIN4000xxK-10K
2 GND Gray
3 SWIN1 Brown
Switch
& 4 GND Gray
Wiegand
5 W-DATA0 Green
6 W-DATA1 White
7 W-GND Black
8 ERX - Yellow
9 ERX + Blue
Network
10 ETX - Orange HON-FIN4000xxK-10K
11 ETX + Pink
55
6.4.2 Installing the bracket
56
6.4.3 Connecting Power & RS-485
HON-FIN4000xxK-10K
※RS-485 can be used as an option to connect to the PC.
For power supply, use a product of DC 12V (± 10%) and minimum 500mA.
To share the power adapter with another device, the required current sum of terminal (500mA)
and another device must not exceed the current capacity.
HON-FIN4000xxK-10K
HON-FIN4000xxK-10K
57
6.4.7 Connecting to a Controller
7 Wiegand IN
6 Ground
D1
5
D0
4 Output (Optional)
3
Ground
Green LED
2
Ground
1 Red LED
58
6.4.8 Electrical specifications
Switching - - 30W DC
power 37.5VA AC
(resistive)
Switching - - 110 DC
voltage (V) 125 AC
HON-FIN4000xxK-10K
59
6.5 Specifications
Item Specification
60
Mechanical Specifications
HON-FIN4000xxK-10K
61
6.6 FCC Notice
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures: ·
62
HONEYWELL