NA Actuator
NA Actuator
NA Actuator
FEATURES
The NA electric actuator is intended for motorising industrial ¼ turn valves. The torque is 2500 Nm maximum.
With a robust construction and IP67 epoxy-coated aluminium housing, the NA actuator is especially well suited
for motorising ball valves and butterfly valves installed in workshops or outdoors. It has handle override and
torque limiters (part for NA06 and NA09). Many available options. The NA-X version can be used in the 1 and 2
explosive atmospheres. Compliant with the EN 15714-2 standard.
AVAILABLE MODELS IP
NA06: 60 Nm to NA250: 2500 Nm
67
Supply voltages: 230 Vac, 400 Vac, 24 Vac, 24 Vdc
LIMITS OF USE
IP Code IP 67
MECHANICAL FEATURES
Gear box treated steel pinions
Angle of rotation angle 90° +/- 5°
Declutching by lever
Override control by wheel
Torque limiter Apart from NA06 and NA09
Actuator NA06 NA09 NA15 NA28 NA38 NA60 NA100 NA150 NA200 NA250
Torque (Nm) 60 90 150 280 380 600 1000 1500 2000 2500
Manoeuvring time (s) 17 17 20 24 24 29 29 87 87 87
ISO 5211 F07 F07 F07/F10 F10/F12 F10/F12 F12/F14 F12/F14 F14/F16 F14/F16 F14/F16
Drive star 17 17 17 22 27 27 27 36 36 46
MANUFACTURING
1 Position indicator Polycarbonate
2 Condenser
3 Wiring terminal box
4 Limit switches
5 Body Aluminium alloy
6 Base Aluminium alloy
7 Drive bushing Steel
8 Dome Polycarbonate
9 Electrical motor
10 Anti-condensation heater
11 Wheel Steel
12 Handle override Steel
13 Declutching lever Steel
14 Worm drive Steel
ELECTRICAL FEATURES
Actuator NA06 NA09 NA15 NA28 NA38 NA60 NA100 NA150 NA200 NA250
Power (W) 15 25 40 40 60 90 180 98 180 180
Voltage 380V – 50Hz
Holding current (A) 00:13 00:18 0.3 0.3 00:33 00:52 0.73 00:52 0.73 0.73
Inrush current (A) 00:23 00:36 00:59 0.74 0.78 01:24 1.68 0.78 1.68 1.68
Voltage 220V – 50Hz
Holding current (A) 00:45 00:58 0.95 0.95 1.3 1.5 02:15 1.5 02:15 02:15
Inrush current (A) 0.63 0.89 01:12 01:37 1.85 02:34 3.4 02:34 3.4 3.4
Voltage 24V – 50 Hz
Holding current (A) 3.2 4.3 6.5 8.1
Inrush current (A) 6 8 12 14
Voltage 24V DC
Holding current (A) 2.2 3.5 4.5 6.5
Inrush current (A) 4.1 4.1 6.6 13.8
DIMENSIONS (mm)
NA 06 to NA 100
NA 150 to NA 250
NA A B C D E F G H
WIRING DIAGRAM
Wiring for 230V 50Hz voltage (NA06-NA09)
1 Do not use
2 Do not use
3 Common
4 phase
5 Closing command
6 Opening command
7 Opening indicator light (suggestion)
8 Closing indicator light (suggestion)
9 Closing auxiliary
10 Closing auxiliary
11 Opening auxiliary
12 Opening auxiliary .
1 Do not use
2 Do not use
3 Common
7 Overheating indicator light (suggestion)
8 Closing indicator light (suggestion)
9 Opening indicator light (suggestion)
10 Opening command
11 Closing command
12 phase
13 Closing auxiliary
14 Closing auxiliary
15 Opening auxiliary
16 Opening auxiliary
1 U phase
2 V phase
3 W phase
4 Heater power supply
5 Connected to the closing 11
6 Connected to the opening 10
7 Not used
8 Closing indicator light (suggestion)
9 Opening indicator light (suggestion)
10 Opening command
11 Closing command
12 Heater power supply
13 Closing auxiliary
14 Closing auxiliary
15 Opening auxiliary
16 Opening auxiliary
1 U phase
2 V phase
3 W phase
4 Heater power supply
5 Connected to the closing 11
6 Connected to the opening 10
7 Overheating indicator light (suggestion)
8 Closing indicator light (suggestion)
9 Opening indicator light (suggestion)
10 Opening command
11 Closing command
12 Heater power supply
13 Closing auxiliary
14 Closing auxiliary
15 Opening auxiliary
16 Opening auxiliary
1 Do not use
2 Do not use
3 Common
4 phase
5 Closing command
6 Opening command
7 Opening indicator light (suggestion)
8 Closing indicator light (suggestion)
9 Closing auxiliary
10 Closing auxiliary
11 Opening auxiliary
12 Opening auxiliary
1 Common
2 phase
3 Not used
4 Closing command
5 Opening command
6 Opening indicator light (suggestion)
7 Closing indicator light (suggestion)
8 Not used
9 Closing auxiliary
10 Closing auxiliary
11 Opening auxiliary
12 Opening auxiliary
OPTIONS
1 NA PIU: version with feedback potentiometer
2 NA CPT: version with position transmitter 4-20 mA
3 NA PCU: version with adjustment card 0-10V, 2-10V, 2-20 mA, 4-20 mA
4 NA LCU: version with local control
5 NA RBP: version with in-built fail safe/security
6 Anti-seismic test
7 Low temperature version -40
8 IP 68 version
9 120°, 135°, 180°, 270° rotation angles
AVAILABLE MODELS
NA09 LCU : 90 Nm
NA15 LCU : 150 Nm
NA28 LCU : 280 Nm
Supply voltages : 230 Vac, 400 Vac
SPECIFICATION
1 IP code : IP67
2 Housing : aluminium
3 Remote, Off, local selector switch
4 Open, stop, close selector switch
5 Remote, local, open, over torque, close LED Lamp
6 Pad lockable
DIMENSIONS (mm)
SPECIFICATION
1 IP rating : IP67
2 Housing : aluminium
3 Return to position due to lack of power
4 Power supply : 230V - 50 / 60Hz
5 Built-in battery safety unit
Battery size : 89 x 111 x 44
Charging volt : DC 32V 1A
Charging time : 3 heures
6
Battery type : Ni-Cd 1,2V 20EA
Emergency (time) : 15 minutes (Max)
Battery weight : 1,1 kg
DIMENSIONS (mm)
Rep A B C D E F G H H1 ØJ