Kidde Catalog u Power Supplies and Accessories

Technology that saves lives

Electromagnetic
Door Holders

R6291

Overview Standard Features


Electromagnetic Door Holders are ruggedly constructed and • Floor and wall mounted styles
attractively designed. The housing is finished with an aluminum
• Low power consumption
color, durable baked polyester powder paint. The floor or wall sec-
tion houses the electromagnet while the contact plate attaches to • AC/DC models
the door. The contact plate has a shock absorbing nylon (swivel) • Completely silent operation
ball which allows the plate to adjust to any door angle. Floor units
are available in single-door or double-door (back to back) versions. • 25 Lbf (111N) nominal holding force
Wall units are available in flush or surface mounted versions. • Adjustable, swivel contact plate
Door releases should be installed wherever doors may be effec-
tively used to confine smoke and fire, or where the release of a self-
closing door from a remote location is desirable for other reasons. Basic Models
Fail-safe operation is an inherent feature of Kidde door holder-re- Floor Mounted:
leases. If power fails, doors are released automatically but may be The electromagnet portion consists of a floor plate and a floor
opened or closed manually at any time. All units are free of moving housing which when installed with gaskets provided, form a
parts, are self-contained and require no maintenance. weatherproof electrical junction box. Incoming conduit connects
directly into floor plate.
These door holder-releases have a holding force of approximately
15 to 25 Lbf (66 to 111N). The device holds a door open while en- Floor mounted units are available with one (Cat. No. 1501) or two
ergized. When de-energized by a relay controlled by the fire alarm (Cat. No. 1502) magnet faces for holding a single door or two
system or other switch, the door is released to a closed position, doors back to back.
checking the spread of smoke and flames. Electromagnetic door Wall Mounted:
holders should be used and installed in accordance with local Wall mounted models are available in flush, semi-flush and surface
Building Codes and Standards. mounting configurations. Flush and semi-flush models are de-
signed for concealed wiring applications and mount on standard
single gang (2 x 4 inch) outlet boxes. Surface mounted models
mount on a surface adaptor housing (junction box), which is
provided.

Page 1 of 4 D ATA S H E E T K85001-0421


Not to be used for installation purposes. Issue 1
Dimensions

1504-AQN5 Flush Wall Mounted (Long Catch Plate) 1505-AQN5 Flush Wall Mounted (Short Catch Plate)

1501-AQN5 Floor Mounted (Single Door) 1508-AQN5 Surface Wall Mounted

8" max. / 6.37" min.


(203.2 mm max. / 161.8 mm min.)

1502-AQN5 Floor Mounted (Double Door) 1509-AQN5 Completely Flush Wall Mounted
12" max. / 8.37" min.
(304.8 mm max. / 212.6 mm min.)

Catch Plate Extensions


Only the extension rods are included. The end pieces are included
with the doorholders or can be ordered separately. 2.342"
(59.5 mm)
2.0"
1.5" (50.8 mm)
(38 mm) 1.68"
8" max. / 6.37" min. (47.7 mm)
(203.2 mm max. / 161.8 mm min.)
1500-1 1500-2

1500-7
4.125" 4.625"
3.125" 3.625" (104.8 mm) (117.5 mm)
12" max. / 8.37" min. (79.4 mm) (92 mm)
(304.8 mm max. / 212.6 mm min.)

1500-1 1500-2 1500-1 1500-2


1500-12

2.342"
(59.5 mm)
2.0"
1.5" (50.8 mm)
(38 mm) 1.68"
(47.7 mm)

4.125" 4.625"
3.125" 3.625" (104.8 mm) (117.5 mm)
(79.4 mm) (92 mm)

Page 2 of 4 D ATA S H E E T K85001-0421


Not to be used for installation purposes. Issue 1
Specifications
Model No. Style Volts Amps*
1501-AQN5 Floor Mounted (Single Door)
1502-AQN5 Floor Mounted (Double Door)
1504-AQN5 Flush Wall Mounted (Long Catch Plate) 24 Vac 60 Hz
.015
1505-AQN5 Flush Wall Mounted (Short Catch Plate) 24 Vdc 120 Vac 60 Hz
1508-AQN5 Surface Wall Mounted
1509-AQN5 Completely Flush Wall Mounted
*1502-AQN5 is a double unit which draws .015 per side

Ordering Information
Ship. Wt.
Model No. Description
lb (kg)
1501-AQN5 Floor Mounted (Single Door) 5.4 (2.45)
1502-AQN5 Floor Mounted (Double Door) 5.0 (2.27)
1504-AQN5 Flush Wall Mounted (Long Catch Plate) 2.0 (0.91)
1505-AQN5 Flush Wall Mounted (Short Catch Plate) 2.0 (0.91)
1508-AQN5 Surface Wall Mounted 3.0 (1.36)
1509-AQN5 Completely Flush Wall Mounted 2.0 (0.91)

Accessories
1500-1 Catch plate extension assembly, 1.5” 0.25 (0.11)
1500-2 Catch plate extension assembly, 2.5” 0.25 (0.11)
1500-7 Catch plate extension assembly (5.25 to 7.5 inches) 0.5 (0.23)
1500-12 Catch plate extension assembly (7.5 to 12 inches) 1.0 (0.45)
CS2595-5 Replacement armature - short (for use with 1501, 1502, 1505, 1508 and 1509 door holders) 0.25 (0.11)
CS2598-5 Replacement armature - long (for use with 1504 door holder) 0.25 (0.11)

CAUTION: These Door Holder units will not operate without electrical power.

Page 3 of 4 D ATA S H E E T K85001-0421


Not to be used for installation purposes. Issue 1
Technology that saves lives

Contact us...
Email: kidde.fire@fs.utc.com
Web: Kidde.com/EngineeredSystems

Kidde is a UTC brand.


1016 Corporate Park Drive
Mebane, NC 27302

© 2016 United Technologies Corporation.


All rights reserved.

10-11-16

Page 4 of 4 D ATA S H E E T K85001-0421


Not to be used for installation purposes. Issue 1

You might also like