Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Your Search For Proximity Sensors Starts With The World-Leading Performance and Quality of The E2E

Download as pdf or txt
Download as pdf or txt
You are on page 1of 29

Standard Proximity Sensor

E2E
(DC 2/3-Wire)

Your Search for Proximity Sensors


Starts with the World-leading (Standards do not apply to all models.)

Performance and Quality of the E2E


• Standard Sensors for detecting ferrous metals.
• Wide array of variations. Ideal for a variety of applications.
• Models with different frequencies are also available to prevent
mutual interference.
• Superior environment resistance with standard cable made of
oil-resistant PVC and sensing surface made of material that
resists cutting oil.
• Useful to help prevent disconnection.
Cable protector provided as a standard feature.

For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Be sure to read Safety Precautions on
Note: DC 2-Wire Models have been integrated into the E2E NEXT Series
page 18. at the end of october 2022.
DC 3-Wire Models have been discontinued at the end of March 2022.
Refer to the catalog (Cat. No. D120) for details.
Features
Lineup includes models with Smartclick pre-wired connectors for fast connection.
XS5 Smartclick connectors used to
enable checking connector mating

Jacket: Polyester elastomer


Clic
k
Insert all
the way.
1/8 turn
Insulation: Oil-resistant grade PUR (polyurethane)

UL-recognized Models Available

1
E2E
E2E Model Number Legend

E2E- (1) (2) (3) (4) (5) (6) (7) - (8) (9) - (10) - (11) - (12) (13)
No. Classification Code Meaning Remarks
(1) Appearance X Cylindrical (threaded)
Number Sensing distance (Unit: mm) Example:
(2) Sensing distance
R Indication of decimal point 1R5: 1.5 mm
Blank Shielded Model
(3) Shielding
M Unshielded Model
B DC 3-wire PNP open-collector output
C DC 3-wire NPN open-collector output
D DC 2-wire polarity/no polarity Whether D models have
Power supply and output
(4) E DC 3-wire NPN collector load built-in output polarity is defined by num-
specifications
F DC 3-wire PNP collector load built-in output ber 10.
T AC/DC 2-wire
Y AC 2-wire
Form of output switching el- 1 Normally open (NO)
(5)
ement 2 Normally closed (NC)
Blank Standard frequency Used to prevent mutual in-
(6) Oscillation frequency type
5 Different frequency terference.
Blank No
(7) Self-diagnosis
5 Yes
Blank Pre-wired

(8) Connection method M1 M12-size metal connector

M3 M8-size metal connector


Connector Model
Blank DC 3-wire and AC 2-wire, DC 2-wire with self-diagnosis output,
DC 2-wire with old pin arrangement
Connector Model
G
DC 2-wire with IEC pin arrangement
Pre-wired Connector Model
J
(9) Connector specifications DC 3-wire and AC 2-wire, DC 2-wire with old pin arrangement
Pre-wired Connector Model
GJ
DC 2-wire with IEC pin arrangement
Pre-wired Smartclick Connector Model
TJ
DC 2-wire
Pre-wired Smartclick Connector Model
TGJ
DC 2-wire with IEC pin arrangement
Blank Polarity
(10) DC 2-wire polarity
T No polarity
Blank Standard PVC cable (oil resistant)
(11) Cable specifications R Flexible PVC cable (oil resistant)
U Polyurethane cable (oil resistant and reinforced)
This is blank if the cable
New model (Applies only to DC 2-wire pre-wired and shielded
New model N specification in number 11
models.)
(12) is R or U.
UL-recognized model (Applies to DC 2-wire pre-wired models
Standard-certified model US
and pre-wired connector models.)
Example:
Cable length (Unit: m) (Applicable to Pre-wired Models and Pre-
(13) Cable length Letter M 2M
wired Connector Models.)
0.3M
Note: The purpose of this model number legend is to provide understanding of the meaning of specifications from the model number.
Models are not available for all combinations of code numbers.

2
E2E
Note: DC 2-Wire Models have been integrated into the E2E NEXT Series at the end of october 2022.
Ordering Information Refer to the catalog (Cat. No. D120) for details.

2-Wire Models

Shielded DC 2-wire Models with No Self-diagnostic Output [Refer to Dimensions on page 20.]

Appear- Connection Cable Polar- Opera- Pin Applicable


Sensing distance tion connector Model
ance method specifications ity arrangement
mode code *2
M12 Pre-wired Smart-
click Connector Mod- PVC (oil-resistant) NO 1: +V, 4: 0 V E E2E-X2D1-M1TGJ 0.3M
els (0.3m)
Pre-wired Models NO E2E-X2D1-N 2M
(2 m) PVC (oil-resistant) --- ---
NC E2E-X2D2-N 2M
M8 2 mm Yes
M12 Connector Mod- NO 1: +V, 4: 0 V A E2E-X2D1-M1G
els ---
NC 1: +V, 2: 0 V D E2E-X2D2-M1G
NO 1: +V, 4: 0 V E2E-X2D1-M3G
M8 Connector Models --- F
NC 1: +V, 2: 0 V E2E-X2D2-M3G
M12 Pre-wired Smart-
click Connector Mod- PVC (oil-resistant) NO 1: +V, 4: 0 V E E2E-X3D1-M1TGJ 0.3M
els (0.3m)
Pre-wired Models NO E2E-X3D1-N 2M *1
PVC (oil-resistant) Yes --- ---
(2 m) NC E2E-X3D2-N 2M
M12 Connector Mod- NO 1: +V, 4: 0 V A E2E-X3D1-M1G *1
M12 3 mm ---
els NC 1: +V, 2: 0 V D E2E-X3D2-M1G
NO 1: +V, 4: 0 V A E2E-X3D1-M1GJ 0.3M
Yes
M12 Standard Pre- NC 1: +V, 2: 0 V D E2E-X3D2-M1GJ 0.3M
wired Connector Mod- PVC (oil-resistant)
els (0.3 m) NO (3, 4): (+V, 0 V) C E2E-X3D1-M1J-T 0.3M
No *3
NC (1, 2): (+V, 0 V) D ---
M12 Pre-wired Smart-
click Connector Mod- PVC (oil-resistant) NO 1: +V, 4: 0 V E E2E-X7D1-M1TGJ 0.3M
els (0.3m)
Pre-wired Models NO E2E-X7D1-N 2M *1
PVC (oil-resistant) Yes --- ---
(2 m) NC E2E-X7D2-N 2M
M12 Connector Mod- NO 1: +V, 4: 0 V A E2E-X7D1-M1G *1
M18 7 mm ---
els NC 1: +V, 2: 0 V D E2E-X7D2-M1G
NO 1: +V, 4: 0 V A E2E-X7D1-M1GJ 0.3M
Yes
M12 Standard Pre- NC 1: +V, 2: 0 V D E2E-X7D2-M1GJ 0.3M
wired Connector Mod- PVC (oil-resistant)
els (0.3 m) NO (3, 4): (+V, 0 V) C E2E-X7D1-M1J-T 0.3M
No *3
NC (1, 2): (+V, 0 V) D E2E-X7D2-M1J-T 0.3M
M12 Pre-wired Smart-
click Connector Mod- PVC (oil-resistant) NO 1: +V, 4: 0 V E E2E-X10D1-M1TGJ 0.3M
els (0.3m)
Pre-wired Models NO E2E-X10D1-N 2M *1
PVC (oil-resistant) Yes --- ---
(2 m) NC E2E-X10D2-N 2M
M12 Connector Mod- NO 1: +V, 4: 0 V A E2E-X10D1-M1G *1
M30 10 mm ---
els NC 1: +V, 2: 0 V D E2E-X10D2-M1G
NO 1: +V, 4: 0 V A E2E-X10D1-M1GJ 0.3M
Yes
M12 Standard Pre- NC 1: +V, 2: 0 V D E2E-X10D2-M1GJ 0.3M
wired Connector Mod- PVC (oil-resistant)
els (0.3 m) NO (3, 4): (+V, 0 V) C E2E-X10D1-M1J-T 0.3M
No *3
NC (1, 2): (+V, 0 V) D E2E-X10D2-M1J-T 0.3M

*1. Models with different frequencies are also available. The model number is E2E-X @D15 (example: E2E-X3D15-N 2M).
*2. Refer to page 15 for details.
*3. The residual voltage for models without polarity is 5 V, so use caution concerning the connection load interface conditions (e.g., PLC ON voltage).
Refer to page 19

3
E2E
Note: DC 2-Wire Models have been integrated into the E2E NEXT Series at the end of october 2022.
Refer to the catalog (Cat. No. D120) for details.

2-Wire Models

Shielded DC 2-Wire UL-recognized Models with No Self-diagnostic Output [Refer to Dimensions on page 20.]

Opera- Applicable
Appear- Connection Cable Polar- Pin
Sensing distance tion connector Model
ance method specifications ity mode arrangement code *
M12 Pre-wired Smart- NO 1: +V, 4: 0 V E2E-X2D1-M1TGJ-US 0.3M
click Connector Models E
(0.3 m) NC 1: +V, 2: 0 V E2E-X2D2-M1TGJ-US 0.3M
M8 2 mm
NO E2E-X2D1-US 2M
Pre-wired Models (2 m) --- ---
NC E2E-X2D2-US 2M
M12 Pre-wired Smart- NO 1: +V, 4: 0 V E2E-X3D1-M1TGJ-US 0.3M
click Connector Models E
(0.3 m) NC 1: +V, 2: 0 V E2E-X3D2-M1TGJ-US 0.3M
M12 3 mm
NO E2E-X3D1-US 2M
Pre-wired Models (2 m) --- ---
NC E2E-X3D2-US 2M
PVC (oil-resistant) Yes
M12 Pre-wired Smart- NO 1: +V, 4: 0 V E2E-X7D1-M1TGJ-US 0.3M
click Connector Models E
(0.3 m) NC 1: +V, 2: 0 V E2E-X7D2-M1TGJ-US 0.3M
M18 7 mm
NO E2E-X7D1-US 2M
Pre-wired Models (2 m) --- ---
NC E2E-X7D2-US 2M
M12 Pre-wired Smart- NO 1: +V, 4: 0 V E2E-X10D1-M1TGJ-US 0.3M
click Connector Models E
(0.3 m) NC 1: +V, 2: 0 V E2E-X10D2-M1TGJ-US 0.3M
M30 10 mm
NO E2E-X10D1-US 2M
Pre-wired Models (2 m) --- ---
NC E2E-X10D2-US 2M

* Refer to page 15 for details.

4
E2E
Note: DC 2-Wire Models have been integrated into the E2E NEXT Series at the end of october 2022.
Refer to the catalog (Cat. No. D120) for details.

2-Wire Models

Unshielded DC 2-Wire Models with No Self-diagnosis Output [Refer to Dimensions on page 20.]

Opera- Applicable
Appear- Connection Cable Polar- Pin
Sensing distance tion connector Model
ance method specifications ity mode arrangement code *2
NO E2E-X4MD1 2M
Pre-wired Models (2 m) PVC (oil-resistant) --- ---
NC E2E-X4MD2 2M
NO 1: +V, 4: 0 V A E2E-X4MD1-M1G
M8 4 mm M12 Connector Models ---
NC 1: +V, 2: 0 V D E2E-X4MD2-M1G
NO 1: +V, 4: 0 V E2E-X4MD1-M3G
M8 Connector Models --- F
NC 1: +V, 2: 0 V E2E-X4MD2-M3G
M12 Pre-wired Smart-
click Connector Models PVC (oil-resistant) NO 1: +V, 4: 0 V E E2E-X8MD1-M1TGJ 0.3M
(0.3m)
NO E2E-X8MD1 2M *1
Pre-wired Models (2 m) PVC (oil-resistant) --- ---
NC E2E-X8MD2 2M
M12 8 mm
NO 1: +V, 4: 0 V A E2E-X8MD1-M1G *1
M12 Connector Models ---
NC 1: +V, 2: 0 V D E2E-X8MD2-M1G
M12 Standard Pre- NO 1: +V, 4: 0 V A E2E-X8MD1-M1GJ 0.3M
wired Connector Mod- PVC (oil-resistant)
els (0.3 m) NC 1: +V, 2: 0 V D ---
M12 Pre-wired Smart-
click Connector Models PVC (oil-resistant) Yes NO 1: +V, 4: 0 V E E2E-X14MD1-M1TGJ 0.3M
(0.3m)
NO E2E-X14MD1 2M *1
Pre-wired Models (2 m) PVC (oil-resistant) --- ---
NC E2E-X14MD2 2M
M18 14 mm
NO 1: +V, 4: 0 V A E2E-X14MD1-M1G *1
M12 Connector Models ---
NC 1: +V, 2: 0 V D E2E-X14MD2-M1G
M12 Standard Pre- NO 1: +V, 4: 0 V A E2E-X14MD1-M1GJ 0.3M
wired Connector Mod- PVC (oil-resistant)
els (0.3 m) NC 1: +V, 2: 0 V D E2E-X14MD2-M1GJ 0.3M
M12 Pre-wired Smart-
click Connector Models PVC (oil-resistant) NO 1: +V, 4: 0 V E E2E-X20MD1-M1TGJ 0.3M
(0.3m)
NO E2E-X20MD1 2M *1
Pre-wired Models (2 m) PVC (oil-resistant) --- ---
NC E2E-X20MD2 2M
M30 20 mm
NO 1: +V, 4: 0 V A E2E-X20MD1-M1G *1
M12 Connector Models ---
NC 1: +V, 2: 0 V D E2E-X20MD2-M1G
M12 Standard Pre- NO 1: +V, 4: 0 V A E2E-X20MD1-M1GJ 0.3M
wired Connector Mod- PVC (oil-resistant)
els (0.3 m) NC 1: +V, 2: 0 V D ---

*1. Models with different frequencies are also available. The model number is E2E-X @D15 (example: E2E-X8MD15 2M).
*2. Refer to page 15 for details.

5
E2E
Note: DC 2-Wire Models have been integrated into the E2E NEXT Series at the end of october 2022.
Refer to the catalog (Cat. No. D120) for details.

2-Wire Models

Unshielded DC 2-Wire UL-recognized Models with No Self-diagnostic Output [Refer to Dimensions on page 20.]

Opera- Applicable
Appear- Connection Cable Polar- Pin
Sensing distance tion connector Model
ance method specifications ity mode arrangement code *
M12 Pre-wired Smart- NO 1: +V, 4: 0 V E2E-X4MD1-M1TGJ-US 0.3M
click Connector Models E
(0.3 m) NC 1: +V, 2: 0 V E2E-X4MD2-M1TGJ-US 0.3M
M8 4 mm
NO E2E-X4MD1-US 2M
Pre-wired Models (2 m) --- ---
NC E2E-X4MD2-US 2M
M12 Pre-wired Smart- NO 1: +V, 4: 0 V E2E-X8MD1-M1TGJ-US 0.3M
click Connector Models E
(0.3 m) NC 1: +V, 2: 0 V E2E-X8MD2-M1TGJ-US 0.3M
M12 8 mm
NO E2E-X8MD1-US 2M
Pre-wired Models (2 m) --- ---
NC E2E-X8MD2-US 2M
PVC (oil-resistant) Yes
M12 Pre-wired Smart- NO 1: +V, 4: 0 V E2E-X14MD1-M1TGJ-US 0.3M
click Connector Models E
(0.3 m) NC 1: +V, 2: 0 V E2E-X14MD2-M1TGJ-US 0.3M
M18 14 mm
NO E2E-X14MD1-US 2M
Pre-wired Models (2 m) --- ---
NC E2E-X14MD2-US 2M
M12 Pre-wired Smart- NO 1: +V, 4: 0 V E2E-X20MD1-M1TGJ-US 0.3M
click Connector Models E
(0.3 m) NC 1: +V, 2: 0 V E2E-X20MD2-M1TGJ-US 0.3M
M30 20 mm
NO E2E-X20MD1-US 2M
Pre-wired Models (2 m) --- ---
NC E2E-X20MD2-US 2M
* Refer to page 15 for details.

Connector Pin Assignments of DC 2-Wire Models


• The connector pin assignments of each New E2E DC 2-Wire Model
conform to IEC 947-5-2 Table III. (Only DC 2-Wire Models have Cable length Model
been changed in comparison to the previous models.) 500 mm XS2W-D421-BY1
• The following models with conventional connector pin assignments
are available as well. (Only NO Models can be used.) Internal Wiring
The cable at the right should also be used if the XW3D-P@55-G11/ (Proximity Sensor end) (Wired end)
XW3B-P@55-G11 Connector Junction Box is already being used.
1 4
4 3

Models with conventional connector pin assignments are available as well.


Model
Appearance
NO Applicable connector code * NC Applicable connector code *
M8 E2E-X2D1-M1 C E2E-X2D2-M1 D
Shielded M12 E2E-X3D1-M1 C E2E-X3D2-M1 D
M18 E2E-X7D1-M1 C E2E-X7D2-M1 D
M30 E2E-X10D1-M1 C E2E-X10D2-M1 D
M8 E2E-X4MD1-M1 C E2E-X4MD2-M1 D
Unshielded M12 E2E-X8MD1-M1 C E2E-X8MD2-M1 D
M18 E2E-X14MD1-M1 C E2E-X14MD2-M1 D
M30 E2E-X20MD1-M1 C E2E-X20MD2-M1 D
* Refer to page 15 for details.

6
E2E
Note: DC 3-Wire Models have been discontinued at the end of March 2022.
Refer to the catalog (Cat. No. D120) for details.

3-Wire Models

Shielded DC 3-Wire Models [Refer to Dimensions on page 20.]

Appli- Model
Appear- Connection Cable Opera- Pin cable
Sensing distance specifica- tion connec-
ance method arrangement NPN output PNP output
tions mode tor code
*2
PVC (oil-re-
NO E2E-X1R5E1 2M E2E-X1R5F1 2M
Pre-wired Models sistant)
--- ---
(2 m) PVC (oil-re-
NC E2E-X1R5E2 2M E2E-X1R5F2 2M
sistant)
1: +V, 3: 0 V,
NO B E2E-X1R5E1-M1 E2E-X1R5F1-M1
M12 Connector 4: Control output
M8 1.5 mm Models
---
1: +V, 3: 0 V,
NC D E2E-X1R5E2-M1 E2E-X1R5F2-M1
2: Control output
1: +V, 3: 0 V,
NO E2E-X1R5E1-M3 E2E-X1R5F1-M3
M8 Connector 4: Control output
Models --- F
1: +V, 3: 0 V,
NC E2E-X1R5E2-M3 E2E-X1R5F2-M3
2: Control output
Pre-wired Models PVC (oil-re- NO E2E-X2E1 2M *1 E2E-X2F1 2M *1
--- ---
(2 m) sistant) NC E2E-X2E2 2M E2E-X2F2 2M
M12 2 mm 1: +V, 3: 0 V,
NO B E2E-X2E1-M1 E2E-X2F1-M1
M12 Connector 4: Control output
---
Models 1: +V, 3: 0 V,
NC D E2E-X2E2-M1 E2E-X2F2-M1
2: Control output
Pre-wired Models PVC (oil-re- NO E2E-X5E1 2M *1 E2E-X5F1 2M *1
--- ---
(2 m) sistant) NC E2E-X5E2 2M E2E-X5F2 2M
M18 5 mm 1: +V, 3: 0 V,
NO B E2E-X5E1-M1 E2E-X5F1-M1
M12 Connector 4: Control output
---
Models 1: +V, 3: 0 V,
NC D E2E-X5E2-M1 E2E-X5F2-M1
2: Control output
Pre-wired Models PVC (oil-re- NO E2E-X10E1 2M *1 E2E-X10F1 2M
--- ---
(2 m) sistant) NC E2E-X10E2 2M E2E-X10F2 2M
M30 10 mm 1: +V, 3: 0 V,
NO B E2E-X10E1-M1 E2E-X10F1-M1
M12 Connector 4: Control output
---
Models 1: +V, 3: 0 V,
NC D E2E-X10E2-M1 E2E-X10F2-M1
2: Control output
*1. Models with different frequencies are also available. The model number is E2E-X@@@5 (example: E2E-X5E15 2M).
*2. Refer to page 15 for details.

7
E2E
Note: DC 3-Wire Models have been discontinued at the end of March 2022.
Refer to the catalog (Cat. No. D120) for details.

3-Wire Models

Unshielded DC 3-Wire Models [Refer to Dimensions on page 20.]

Appli- Model
Appear- Connection Cable Opera- Pin cable
Sensing distance tion connec-
ance method specifications arrangement NPN output PNP output
mode tor code
*2
Pre-wired Models PVC (oil-resis- NO E2E-X2ME1 2M E2E-X2MF1 2M
--- ---
(2 m) tant) NC E2E-X2ME2 2M E2E-X2MF2 2M
1: +V, 3: 0 V,
NO B E2E-X2ME1-M1 E2E-X2MF1-M1
M12 Connector 4: Control output
---
Models 1: +V, 3: 0 V,
M8 2 mm NC D E2E-X2ME2-M1 E2E-X2MF2-M1
2: Control output
1: +V, 3: 0 V,
NO E2E-X2ME1-M3 E2E-X2MF1-M3
M8 Connector 4: Control output
Models --- F
1: +V, 3: 0 V,
NC E2E-X2ME2-M3 E2E-X2MF2-M3
2: Control output
Pre-wired Models PVC (oil-resis- NO E2E-X5ME1 2M *1 E2E-X5MF1 2M
--- ---
(2 m) tant) NC E2E-X5ME2 2M E2E-X5MF2 2M
M12 5 mm 1: +V, 3: 0 V,
NO B E2E-X5ME1-M1 E2E-X5MF1-M1
M12 Connector 4: Control output
Models ---
1: +V, 3: 0 V,
NC D E2E-X5ME2-M1 E2E-X5MF2-M1
2: Control output
Pre-wired Models PVC (oil-resis- NO E2E-X10ME1 2M *1 E2E-X10MF1 2M
--- ---
(2 m) tant) NC E2E-X10ME2 2M E2E-X10MF2 2M
M18 10 mm 1: +V, 3: 0 V,
NO 4: Control output B E2E-X10ME1-M1 E2E-X10MF1-M1
M12 Connector
---
Models 1: +V, 3: 0 V,
NC D E2E-X10ME2-M1 E2E-X10MF2-M1
2: Control output
Pre-wired Models PVC (oil-resis- NO E2E-X18ME1 2M *1 E2E-X18MF1 2M
--- ---
(2 m) tant) NC E2E-X18ME2 2M E2E-X18MF2 2M
M30 18 mm NO
1: +V, 3: 0 V,
B E2E-X18ME1-M1 E2E-X18MF1-M1
M12 Connector 4: Control output
---
Models 1: +V, 3: 0 V,
NC D E2E-X18ME2-M1 E2E-X18MF2-M1
2: Control output
*1. Models with different frequencies are also available. The model number is E2E-X@M@@5 (example: E2E-X5ME15 2M).
*2. Refer to page 15 for details.

8
E2E
Note: DC 2-Wire Models have been integrated into the E2E NEXT Series at the end of october 2022.
Ratings and Specifications Refer to the catalog (Cat. No. D120) for details.

E2E-X@D@ DC 2-Wire Models


Size M8 M12 M18 M30
Shielded Shielded Unshielded Shielded Unshielded Shielded Unshielded Shielded Unshielded
Item Model E2E-X2D@ E2E-X4MD@ E2E-X3D@ E2E-X8MD@ E2E-X7D@ E2E-X14MD@ E2E-X10D@ E2E-X20MD@
Sensing distance 2 mm ±10% 4 mm ±10% 3 mm ±10% 8 mm ±10% 7 mm ±10% 14 mm ±10% 10 mm ±10% 20 mm ±10%
Set distance *1 0 to 1.6 mm 0 to 3.2 mm 0 to 2.4 mm 0 to 6.4 mm 0 to 5.6 mm 0 to 11.2 mm 0 to 8 mm 0 to 16 mm
Differential travel 15% max. of sensing distance 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 11 and 12.
Standard sensing Iron, Iron, Iron, Iron, Iron, Iron,
Iron, 30 × 30 × 1 mm
object 8 × 8 × 1 mm 20 × 20 × 1 mm 12 × 12 × 1 mm 30 × 30 × 1 mm 18 × 18 × 1 mm 54 × 54 × 1 mm
Response frequency
1.5 kHz 1 kHz 0.8 kHz 0.5 kHz 0.4 kHz 0.1 kHz
*2
Power supply voltage Standard Models: 12 to 24 VDC, ripple (p-p): 10% max. (10 to 30 VDC)
(operating voltage US Models and Connector Models Used as UL-certified Models:
range) 12 to 24 VDC, ripple (p-p): 10% max. (The operating voltage range is also the same.) *3
Leakage current 0.8 mA max.
Load
3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models
current
Control
output Residual
voltage 3 V max. (Load current: 100 mA, Cable length: 2 m, M1J-T Models only: 5 V max.)
*4
D1 Models: Operation indicator (red) and setting indicator (green)
Indicators
D2 Models: Operation indicator (red)
Operation mode
D1 Models: NO Refer to the timing charts under I/O Circuit Diagrams on page 13 for details.
(with sensing object D2 Models: NC
approaching)
Diagnostic output
0.3 to 1 s
delay
Protection circuits Surge suppressor, Load short-circuit protection (for control and diagnostic output)
Ambient
Operating: −25 to 70°C, Storage: −40 to 85°C (with no icing or condensation)
temperature range
Ambient
Operating/storage: 35% to 95% (with no condensation)
humidity range
±15% max. of sensing distance
Temperature
influence at 23°C in the temperature range ±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
of −25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s2
Shock resistance 10 times each in X, Y, and Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Z directions
Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant
Degree of protection
Connector Models: IEC 60529 IP67
Connection method Pre-wired Models (Standard cable length: 2 m), Connector Models, or Pre-wired Connector Models (Standard cable length: 0.3 m)
Pre-wired
Approx. 60 g Approx. 70 g Approx. 130 g Approx. 175 g
Models
Weight
Pre-wired
(pack-
ed Connector --- Approx. 40 g Approx. 70 g Approx. 110 g
state) Models
Connector
Approx. 15 g Approx. 25 g Approx. 40 g Approx. 90 g
Models
Case Stainless steel (SUS303) Nickel-plated brass
Sensing sur-
face PBT
Materi-
als Clamping
Nickel-plated brass
nuts
Toothed
Zinc-plated iron
washer
Accessories Instruction manual
*1. Use the E2E within the range in which the setting indicator (green LED) is ON (except D2 Models).
*2. The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*3. For the information on UL-certified connector models, refer to your OMRON website.
*4. The residual voltage of each M1J-T Model is 5 V. When connecting to a device, make sure that the device can withstand the residual voltage. (Refer to page 19 for
details.)

9
E2E
Note: DC 3-Wire Models have been discontinued at the end of March 2022.
Refer to the catalog (Cat. No. D120) for details.

E2E-X@E@/F@ DC 3-Wire Models


Size M8 M12 M18 M30
Shielded Shielded Unshielded Shielded Unshielded Shielded Unshielded Shielded Unshielded
E2E E2E E2E E2E E2E E2E E2E-X10E@/ E2E
Item Model
-X1R5E@/F@ -X2ME@/F@ -X2E@/F@ -X5ME@/F@ -X5E@/F@ -X10ME@/F@ F@ -X18ME@/F@
Sensing distance 1.5 mm ±10% 2 mm ±10% 5 mm ±10% 10 mm ±10% 18 mm ±10%
Set distance 0 to 1.2 mm 0 to 1.6 mm 0 to 4 mm 0 to 8 mm 0 to 14 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 12.)
Standard sensing Iron, Iron, Iron, Iron,
Iron, 12 × 12 × 1 mm Iron, 30 × 30 × 1 mm
object 8 × 8 × 1 mm 15 ×15 × 1 mm 18 × 18 × 1 mm 54 × 54 × 1 mm
Response frequency
2 kHz 0.8 kHz 1.5 kHz 0.4 kHz 0.6 kHz 0.2 kHz 0.4 kHz 0.1 kHz
*1
Power supply voltage
12 to 24 VDC, ripple(p-p): 10% max. (10 to 30 VDC)
(operating voltage Connector Models Used as UL-certified Models: 12 to 24 VDC, ripple (p-p): 10% max. (The operating voltage range is also the same.) *3
range) *2
Current consumption 13 mA max.
Load
200 mA max.
Control current *2
output Residual
2 V max. (Load current: 200 mA, Cable length: 2 m)
voltage
Indicators Operation indicator (red)
Operation mode E1/F1 Models: NO
(with sensing object E2/F2 Models: NC
approaching) Refer to the timing charts under /O Circuit Diagrams on page 14 for details.
Protection circuits Load short-circuit protection, Surge suppressor, Reverse polarity protection
Ambient
temperature range *2 Operating/Storage: −40 to 85°C (with no icing or condensation)

Ambient humidity
range Operating/Storage: 35% to 95% (with no condensation)

Temperature ±15% max. of sensing distance at 23°C in the temperature range of −40 to 85°C
influence ±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s2
Shock resistance 10 times each in X, Y, and Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Z directions
Pre-wired Models : IEC 60529 IP67, in-house standards: oil-resistant
Degree of protection
Connector Models : IEC 60529 IP67
Connection method Pre-wired Models (Standard cable length: 2 m) and Connector Models
Pre-
wired Approx. 65 g Approx. 75 g Approx. 150 g Approx. 195 g
Weight Models
(packed
state) Connec-
tor Approx. 15 g Approx. 25 g Approx. 40 g Approx. 90 g
Models
Case Stainless steel (SUS303) Nickel-plated brass
Sensing
PBT
surface
Materials Clamp-
Nickel-plated brass
ing nuts
Toothed
Zinc-plated iron
washer
Accessories Instruction manual
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
*2. When using an M8 Model at an ambient temperature between 70 and 85°C, supply 10 to 30 VDC to the Sensor and make sure that the Sensor has a control output
of 100 mA maximum.
*3. For the information on UL-certified connector models, refer to your OMRON website.

10
E2E
Note: DC 2-Wire Models have been integrated into the E2E NEXT Series at
the end of october 2022. DC 3-Wire Models have been discontinued at
Engineering Data (Reference Value) the end of March 2022. Refer to the catalog (Cat. No. D120) for details.

Sensing Area
Shielded Models
E2E-X@D@ E2E-X@E@/-X@F@
12
Distance X (mm)

12

Distance X (mm)
E2E-X10 E2E-X10
10 10

Y
8 8 X
E2E-X7

6 6
E2E-X3 E2E-X5
E2E-X2
4 Y E2E-X2
4
X
E2E
2 2 -X1R5

0 0
20 15 10 5 0 5 10 15 15 10 5 0 5 10
Distance Y (mm) Distance Y (mm)

Unshielded Models
E2E-X@MD@ E2E-X@ME@/-X@MF@
30 30
Distance X (mm)

Distance X (mm)

Y
25 25 X

20 20
E2E E2E-X18M
-X20M
15 15
E2E
-X14M
E2E-X10M
Y
10 10
X E2E E2E-X5M
-X8M
E2E-X2M
5 5
E2E
-X4M
0 0
30 20 10 0 10 20 30 20 10 0 10 20
Distance Y (mm) Distance Y (mm)

Influence of Sensing Object Size and Material


E2E-X2D@ E2E-X3D@ E2E-X7D@
3.0 4.0 8
Distance X (mm)
Distance X (mm)

Distance X (mm)

du du
du
d
t = 1 mm d
d t = 1 mm
3.5 t = 1 mm 7 X Iron
X X
2.5

3.0 Iron 6
2.0 Iron
2.5 5
Stainless Stainless
steel steel
1.5 Stainless 2.0 (SUS304) 4
(SUS304)
steel
(SUS304) Brass
1.5 Brass 3
1.0 Aluminum
Brass Aluminum
Copper
1.0 Copper 2
Aluminum
0.5 Copper
0.5 1

0 5 10 15 20 25 0 5 10 15 20 25 30 35 40 0 10 20 30 40 50
Side length of sensing object: d (mm) Side length of sensing object: d (mm) Side length of sensing object: d (mm)

E2E-X10D@ E2E-X4MD@ E2E-X8MD@


12 6
Distance X (mm)
Distance X (mm)

12
Distance X (mm)

du du du
d d d
t = 1 mm t = 1 mm t = 1 mm
X X X
10 Iron 5 10

8 4 Iron 8 Iron

Stainless
6 3 Stainless 6
steel Stainless
(SUS304) steel steel
Brass (SUS304) (SUS304)
4 Aluminum 2 4
Brass Brass
Copper Aluminum
Copper Aluminum
2 1 Copper
2

0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 0 10 15 20 30 40 50 60 70
Side length of sensing object: d (mm) Side length of sensing object: d (mm) Side length of sensing object: d (mm)

11
E2E
Note: DC 2-Wire Models have been integrated into the E2E NEXT Series at the end of october 2022. DC 3-Wire
Models have been discontinued at the end of March 2022. Refer to the catalog (Cat. No. D120) for details.

E2E-X14MD@ E2E-X20MD@ E2E-X1R5E@/-X1R5F@


25 25 2.5

Distance X (mm)
Distance X (mm)

Distance X (mm)
du du du
d d d
t = 1 mm t = 1 mm t = 1 mm
X X X
20 20 Iron 2.0

Iron
15 15 1.5
Iron Stainless
steel Stainless steel
(SUS304) (SUS304)
10 Stainless 10 1.0
Brass
steel Aluminum
(SUS304) Copper Brass
Brass
5 Aluminum 5 0.5 Aluminum
Copper

0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 80 90 100 0 5 10 15 20 25
Side length of sensing object: d (mm) Side length of sensing object: d (mm) Side length of sensing object: d (mm)

E2E-X2E@/-X2F@ E2E-X5E@/-X5F@ E2E-X10E@/-X10F@

Distance X (mm)
2.5 7 12
Distance X (mm)
Distance X (mm)

du du du
d d d
t = 1 mm t = 1 mm t = 1 mm Iron
X Iron 6 X X
10
2.0
Iron
5
Stainless steel 8
(SUS304) Stainless steel (SUS304)
1.5 Stainless steel
4 (SUS304)
6
3
1.0 Brass
Brass 4
Brass 2
Aluminum
0.5 Aluminum
Aluminum 2
1

0 5 10 15 20 25 0 10 20 30 40 50 0 10 20 30 40 50 60

Side length of sensing object: d (mm) Side length of sensing object: d (mm) Side length of sensing object: d (mm)

E2E-X2ME@/-X2MF@ E2E-X5ME@/-X5MF@ E2E-X10ME@/-X10MF@


7 12
Distance X (mm)

2.5
Distance X (mm)

Distance X (mm)

du du du
d d d
t = 1 mm t = 1 mm t = 1 mm Iron
X Iron 6 X 10 X
2.0
Iron
5
Stainless steel 8
(SUS304)
1.5 Stainless steel
4 (SUS304) Stainless steel (SUS304)
6

Brass 3
1.0
Aluminum Brass 4 Brass
2
Copper
Aluminum
0.5 Aluminum 2
1

0 5 10 15 20 25 30 0 10 20 30 40 50 0 10 20 30 40 50 60

Side length of sensing object: d (mm) Side length of sensing object: d (mm) Side length of sensing object: d (mm)

Leakage Current Residual Output Voltage


E2E-X18ME@/-X18MF@ E2E-X@D@ E2E-X@D@
1.0 5
Residual output voltage (V)
Leakage current (mA)

25
Distance X (mm)

du
d
t = 1 mm
X
20 0.8 4
Iron E2E-X@D1-M1J-T

E2E-X10D1-N
0.6 3
15 E2E-X3D1-N
Stainless steel (SUS304)
E2E-X@D@
0.4 2
10
Brass E2E-X2D1-N
E2E-X7D1-N
0.2 1
5 Aluminum

0
0 5 10 15 20 25 30 1 3 5 10 30 50 100
0 20 40 60 80 100
Power supply voltage (V) Load current (mA)
Side length of sensing object: d (mm)

12
E2E
Note: DC 2-Wire Models have been integrated into the E2E NEXT Series at the end of october 2022.
I/O Circuit Diagrams Refer to the catalog (Cat. No. D120) for details.

E2E-X@D@ DC 2-Wire Models


Operation
Model Timing Chart Output circuit
mode

Polarity: Yes
1
Load
+V
E2E-X@D1-N Prox-
Brown

E2E-X@D1-M1G(J) imity
Sensor
Unstable Set position
E2E-X@D1-M3G Non-sensing sensing main
circuit
E2E-X@D1(-M1TGJ)-US area area Stable sensing area 4
Proximity Sensor
Blue 0V
Sensing
object Note: The load can be connected to either the
Without +V or 0 V side.
self- (%) 100 80 0
diagnostic Rated
Polarity: None
sensing
output: distance ON
NO Setting indicator
OFF (green) 4
Load
ON V
Operation Prox- (0 V)
OFF indicator (red) imity
ON Sensor
Control output main
E2E-X@D1-M1J-T OFF circuit
3
0V
(+V)
Note 1. The load can be connected to either the +V or
0 V side.
2. The E2E-X@D1-M1J-T has no polarity.
Therefore, terminals 3 and 4 have no polarity.

Non-sensing
area Sensing area
Proximity Sensor
1
Sensing Load
object Brown +V
Without Prox-
E2E-X@D2-N imity
self- (%) 100 0 Sensor
E2E-X@D2-M1G
diagnostic main
E2E-X@D2-M3G Rated
circuit
output: 2
E2E-X@D2(-M1TGJ)-US sensing
NC distance Blue 0V
ON
OFF
Operation Note: The load can be connected to either the +V
indicator (red) or 0 V side.
ON
Control output
OFF

13
E2E
Note: DC 3-Wire Models have been discontinued at the end of March 2022.
Refer to the catalog (Cat. No. D120) for details.

DC 3-Wire Models
Output
Operation
specifica- Model Timing Chart Output circuit
mode
tions
Sensing Present
object Not present
Operation 1
ON +V
indicator (red) 100 : Brown
OFF
NO Control output
ON Load
(between brown Constant
Proximity
and black leads) OFF
Sensor current* 4 2
Output voltage High main
Black
(between black circuit
E2E-X@E@ and blue leads)
Low Tr
NPN output E2E-X@E@-M1
E2E-X@E@-M3 Present
3
0V
Sensing object Blue
Not present
Operation indicator
ON
*Constant current output is 1.5 to 3 mA.
(red)
OFF
Note: For Connector Models, the
NC Control output connection between pins 1, 4 and 3
(between brown and ON uses an NO contact, and the
black leads) OFF connection between pins 1, 2 and 3
Output voltage High
uses an NC contact.
(between black and
blue leads) Low

Present
Sensing object 1
Not present Brown
Operation indicator +V
(red) ON
OFF
NO Control output
(Between blue and ON Proximity * Tr
black leads) Sensor
4 2
OFF
Output voltage main
Black
(between brown High
E2E-X@F@ and black leads)
circuit
Low Load
PNP output E2E-X@F@-M1 3
Present 100 :
E2E-X@F@-M3 Sensing object Blue
0V
Not present
Operation indicator
(red) ON
*When a transistor is connected
OFF
NC Control output Note: For Connector Models, the
(Between blue and ON connection between pins 1, 4 and 3
black leads)
OFF uses an NO contact, and the
Output voltage connection between pins 1, 2 and 3
(between brown High
uses an NC contact.
and black leads) Low

14
E2E
Sensor I/O Connectors (Sockets on One Cable End)
Model for Connectors and Pre-wired Connectors: A Connector is not provided with the Sensor. Be sure to order a Connector separately.
[Refer to Dimensions for the XS2, XS3, and XS5.]
Note: DC 2-Wire Models have been integrated into the E2E NEXT Series at the end of
october 2022. DC 3-Wire Models have been discontinued at the end of March 2022.
Refer to the catalog (Cat. No. D120) for details.

Connector
Applicable Applicable Proximity Connection
Cable length 2m Cable length 5m
connector Sensor model diagram
code Screw Appearance *1 CablConnector CablConnector number No. *2
model number model number
Straight XS2F-D421-DA0-F XS2F-D421-GA0-F
A E2E-X@D1-M1G(J) 1
L-shape XS2F-D422-DA0-F XS2F-D422-GA0-F
Straight XS2F-D421-DC0-F XS2F-D421-GC0-F E2E-X@E1-M1
B 9
L-shape XS2F-D422-DC0-F XS2F-D422-GC0-F E2E-X@F1-M1
E2E-X@D1-M1J-T 3
Straight XS2F-D421-DD0 XS2F-D421-GD0
E2E-X@D1-M1 2
C
E2E-X@D1-M1J-T 3
L-shape XS2F-D422-DD0 XS2F-D422-GD0
E2E-X@D1-M1 2
E2E-X@D2-M1G(J) 5
M12 E2E-X@D2-M1J-T 7
Straight XS2F-D421-D80-F XS2F-D421-G80-F E2E-X@D2-M1 6
E2E-X@E2-M1
10
E2E-X@F2-M1
D
E2E-X@D2-M1G(J) 5
E2E-X@D2-M1J-T 7
L-shape XS2F-D422-D80-F XS2F-D422-G80-F E2E-X@D2-M1 6
E2E-X@E2-M1
10
E2E-X@F2-M1
Smartclick Connector, E2E-X@D1-M1TGJ(-US) 13
E XS5F-D421-D80-F XS5F-D421-G80-F
Straight E2E-X@D2-M1TGJ-US 14
E2E-X@D1-M3G 4
E2E-X@D2-M3G 8
Straight XS3F-M421-402-A XS3F-M421-405-A E2E-X@E1-M3
11
E2E-X@F1-M3
E2E-X@E2-M3
12
E2E-X@F2-M3
F M8
E2E-X@D1-M3G 4
E2E-X@D2-M3G 8
L-shape XS3F-M422-402-A XS3F-M422-405-A E2E-X@E1-M3
11
E2E-X@F1-M3
E2E-X@E2-M3
12
E2E-X@F2-M3
Note: Refer to Introduction to Sensor I/O Connectors/Sensor Controllers for details and for information on Cable length and Robotics Cables.
*1. Images of straight and L-shaped connectors.

M12 Straight M12 L-shape M8 Straight M8 L-shape

*2. Refer to Connection Diagrams on page 16 for information on Proximity Sensor and I/O Connector connections.

15
E2E Note: DC 2-Wire Models have been integrated into the E2E NEXT Series at
the end of october 2022. DC 3-Wire Models have been discontinued at
Connections for Sensor I/O Connectors the end of March 2022. Refer to the catalog (Cat. No. D120) for details.

Proximity Sensor
Connection Sensor I/O Connector
Operation Connections
diagram No. Type Model model number
mode
1: Straight E2E XS2F
2: L-shape

DC 2-wire 1 1 Brown (+)


1 E2E-X@D1-M1G/M1GJ XS2F-D42@-@A0-F
(IEC pin wiring)

circuit
2 2

Main
3 3
D: 2-m cable 4 4 Blue ()
G: 5-m cable

1: Straight E2E XS2F


2: L-shape
DC 2-wire 1 1
2 (previous pin E2E-X@D1-M1 XS2F-D42@-@D0

circuit
Main
2 2
wiring) 3 3 Blue ()
D: 2-m cable 4 4 Brown (+)
G: 5-m cable
NO
1: Straight E2E XS2F
2: L-shape

DC 2-wire 1 1
3 E2E-X@D1-M1J-T XS2F-D42@-@D0

circuit
(no polarity)

Main
2 2
3 3 Blue (+) ()
D: 2-m cable 4 4 Brown () (+)
G: 5-m cable

1: Straight E2E XS3F *


2: L-shape

DC 2-wire 1 1 Brown (+)


4 E2E-X@D1-M3G XS3F-M42@-40@-A

circuit
White (not connected)

Main
2 2
(M8 connector) 3 3 Blue (not connected)
2: 2-m cable 4 4 Black ()
5: 5-m cable
1: Straight E2E XS2F *
2: L-shape

5 DC 2-wire E2E-X@D2-M1G/M1GJ XS2F-D42@-@80-F


1 1 Brown (+)

circuit
Main
2 2
(IEC pin wiring) White ()
3 3 Blue (not connected)
D: 2-m cable 4 4 Black (not connected)
G: 5-m cable
1: Straight E2E XS2F *
2: L-shape
DC 2-wire 1 1 Brown (not connected)
6 (previous pin E2E-X@D2-M1 XS2F-D42@-@80-F
circuit

2 2 White (+)
Main

wiring) 3 3 Blue ()


D: 2-m cable 4 4 Black (not connected)
G: 5-m cable
NC
1: Straight E2E XS2F *
2: L-shape

DC 2-wire 1 1 Brown (+)()


7 E2E-X@D2-M1J-T XS2F-D42@-@80-F
circuit

(no polarity)
Main

2 2 White ()(+)
3 3 Blue (not connected)
D: 2-m cable 4 4 Black (not connected)
G: 5-m cable

1: Straight E2E XS3F *


2: L-shape
1 1
DC 2-wire XS3F-M42@-40@-A
Brown (+)
8 E2E-X@D2-M3G 2 2
circuit

(M8 connector) White ()


Main

3 3 Blue (not connected)


2: 2-m cable 4 4 Black (not connected)
5: 5-m cable

* Different from Proximity Sensor wire colors.

16
E2E
Note: DC 2-Wire Models have been integrated into the E2E NEXT Series at the end of october 2022. DC 3-Wire
Models have been discontinued at the end of March 2022. Refer to the catalog (Cat. No. D120) for details.

Proximity Sensor
Connection Sensor I/O Connector
Operation Connections
diagram No. Type Model model number
mode
1: Straight E2E XS2F
2: L-shape
1 1 Brown (+V)
9 NO E2E-X@E/F1-M1 XS2F-D42@-@C0-F

circuit
Main
2 2
3 3 Blue (0 V)
D: 2-m cable 4 4 Black (output)
G: 5-m cable
DC 3-wire
1: Straight E2E XS2F
2: L-shape
1 1 Brown (+V)
10 NC E2E-X@E2/F2-M1 XS2F-D42@-@80-F

circuit
2 2 White (output)

Main
3 3 Blue (0 V)
D: 2-m cable 4 4 Black (not connected)
G: 5-m cable

1: Straight E2E XS3F


2: L-shape
1 1 Brown (+V)
11 NO E2E-X@E1/F1-M3 XS3F-M42@-40@-A

circuit
2 2

Main
White (not connected)
3 3 Blue (0 V)
2: 2-m cable 4 4 Black (output)
DC 3-wire 5: 5-m cable
(M8 connector) 1: Straight E2E XS3F
2: L-shape
1 1 Brown (+V)
12 NC E2E-X@E2/F2-M3 XS3F-M42@-40@-A

circuit
2 2 White (output)

Main
3 3 Blue (0 V)
2: 2-m cable 4 4 Black (not connected)
5: 5-m cable

E2E XS5F
XS5F-D421-@80-F
13 NO E2E-X@D1- 1 1 Brown (+)

circuit
Main
2 2
M1TGJ(-US) D: 2-m cable White (not connected)
3 3 Blue (not connected)
G: 5-m cable
4 4 Black ()
DC 2-wire
(Smartclick
connector) E2E XS5F
XS5F-D421-@80-F
E2E-X@D2- 1 1 Brown ()
14 NC
circuit

M1TGJ-US
Main

2 2 White ()
D: 2-m cable
3 3 Blue (not connected)
G: 5-m cable
4 4 Black (not connected)

Refer to Introduction to Sensor I/O Connectors/Sensor Controllers for details.

17
E2E
Note: DC 2-Wire Models have been integrated into the E2E NEXT Series at the end of october 2022. DC 3-Wire
Safety Precautions Models have been discontinued at the end of March 2022. Refer to the catalog (Cat. No. D120) for details.

Refer to Warranty and Limitations of Liability.


WARNING
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.

CAUTION
• Do not short the load. Explosion or burning may
result.
• Do not supply power to the Sensor with no load,
otherwise Sensor may be damaged.

Precautions for Correct Use


Do not use this product under ambient conditions that exceed the
ratings.
Design
Influence of Surrounding Metal
When mounting the Sensor within a metal panel, ensure that the
clearances given in the following table are maintained. Failure to
maintain these distances may cause deterioration in the performance
of the Sensor.
l

Relationship between Sizes and Models


d dia. n Model Model
m
D E2E-X2D@
m l
Shielded E2E-X1R5E@
Influence of Surrounding Metal (Unit: mm) E2E-X1R5F@
M8
Model Item M8 M12 M18 M30 E2E-X4MD@
l 0 Unshielded E2E-X2ME@
d 8 12 18 30 E2E-X2MF@
Shielded D 0 E2E-X3D@
m 4.5 8 20 40 Shielded E2E-X2E@
DC 2-Wire Models n 12 18 27 45 E2E-X2F@
M12
E2E-X@D@ l 12 15 22 30 E2E-X8MD@
d 24 40 70 90 Unshielded E2E-X5ME@
Unshielded D 12 15 22 30 E2E-X5MF@
m 8 20 40 70 E2E-X7D@
n 24 40 70 90 Shielded E2E-X5E@
l 0 E2E-X5F@
M18
d 8 12 18 30 E2E-X14MD@
Shielded D 0 Unshielded E2E-X10ME@
m 4.5 8 20 40 E2E-X10MF@
DC 3-Wire Models n 12 18 27 45 E2E-X10D@
E2E-X@E@
E2E-X@F@ l 6 15 22 30 Shielded E2E-X10E@
d 24 40 55 90 E2E-X10F@
M30
Unshielded D 6 15 22 30 E2E-X20MD@
m 8 20 40 70 Unshielded E2E-X18ME@
n 24 36 54 90 E2E-X18MF@

18
E2E
Note: DC 2-Wire Models have been integrated into the E2E NEXT Series at the end of october 2022. DC 3-Wire
Models have been discontinued at the end of March 2022. Refer to the catalog (Cat. No. D120) for details.

Mutual Interference Mutual Interference (Unit: mm)


When installing Sensors face-to-face or Model Item M8 M12 M18 M30
side-by-side, ensure that the minimum A 20 30 (20) 50 (30) 100 (50)
distances given in the following table are Shielded
DC 2-Wire Models B 15 20 (12) * 35 (18) * 70 (35)
maintained. E2E-X@D@ A 80 120 (60) 200 (100) 300 (100)
Unshielded
B 60 100 (50) 110 (60) 200 (100)
A 20 30 (20) 50 (30) 100 (50)
Shielded
A DC 3-Wire Models B 15 20 (12) * 35 (18) * 70 (35)
E2E-X@E@/X@F@ A 80 120 (60) 200 (100) 300 (100)
Unshielded
B 60 100 (50) 110 (60) 200 (100)
Note: Values in parentheses apply to Sensors operating at different frequencies.
B * Mutual interference will not occur for close-proximity mounting if models with different frequencies are used together.

Mounting
Tightening Force
Do not tighten the nut with excessive force.
A washer must be used with the nut.

Shielded Models Unshielded Models

Part B Part A Part B Part A

Note: 1. The allowable tightening strength depends on the distance from the edge
of the head, as shown in the following table. (A is the distance from the
edge of the head. B includes the nut on the head side. If the edge of the
nut is in part A, the tightening torque for part A applies instead.)
2. The following strengths assume washers are being used.

Part A Part B
Model
Dimension Torque Torque
Shielded 9
M8 9 N·m 12 N·m
Unshielded 3
M12 30 N·m
M18 70 N·m
M30 180 N·m

Connecting a DC 2-Wire Proximity Sensor to a PLC (Programmable Controller)


Required Conditions Example
Connection to a PLC is possible if the specifications of the PLC and In this example, the above conditions are checked when the Proximity
the Proximity Sensor satisfy the following conditions. (The meanings Sensor is the E2E-X7D1-N and the power supply voltage is 24 V.
of the symbols are given at the right.) 1. VON (14.4 V) ≤ VCC (20.4 V) − VR (3 V) = 17.4 V: OK
1. The ON voltage of the PLC and the residual voltage of the Proximity 2. IOFF (1.3 mA) ≥ Ileak (0.8 mA): OK
Sensor must satisfy the following. 3. ION = [VCC (20.4 V) − VR (3 V) − VPC (4 V)] / RIN (3 kΩ)
VON ≤ VCC − VR = Approx. 4.5 mA
2. The OFF current of the PLC and the leakage current of the Therefore, IOUT (min.) (3 mA) ≤ ION (4.5 mA): OK
Proximity Sensor must satisfy the following. Connection is thus possible.
IOFF ≥ Ileak
(If the OFF current is not listed in the PLC’s input specifications, Connection Example (Reference)
take it to be 1.3 mA.) VON: ON voltage (14.4 V)
3. The ON current of the PLC and the control output of the Proximity ION: ON current (typically 7 mA)
Sensor must satisfy the following. PLC IOFF: OFF current (1.3 mA)
RIN: Input impedance (3 kΩ)
IOUT (min.) ≤ ION ≤ IOUT (max.)
VPC: Internal residual voltage (4 V)
The ON current of the PLC will vary, however, with the power
supply voltage and the input impedance, as shown in the following VR : Output residual voltage (3 V)
Proximity Ileak: Leakage current (0.8 mA)
equation. Sensor IOUT: Control output (3 to 100 mA)
ION = (VCC − VR − VPC) / RIN VCC: Power supply voltage (PLC: 20.4 to 26.4 V)

19
Note: DC 2-Wire Models have been integrated into the E2E NEXT Series at the end of october 2022. DC 3-Wire
E2E Models have been discontinued at the end of March 2022. Refer to the catalog (Cat. No. D120) for details.

(Unit: mm)
Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.

Main Units
Model Number-Dimensions Drawing Number Lookup Table
Model DC 2-Wire Models DC 3-Wire Models
Model Shielded Model No. Model No.
M8 E2E-X2D@(-US) 1 E2E-X1R5E@/F@ 1
M12 E2E-X3D@(-US) 3 E2E-X2E@/F@ 3
Shielded
M18 E2E-X7D@(-US) 5 E2E-X5E@/F@ 5
M30 E2E-X10D@(-US) 7 E2E-X10E@/F@ 7
Pre-wired Models
M8 E2E-X4MD@(-US) 2 E2E-X2ME@/F@ 2
M12 E2E-X8MD@(-US) 4 E2E-X5ME@/F@ 4
Unshielded
M18 E2E-X14MD@(-US) 6 E2E-X10ME@/F@ 6
M30 E2E-X20MD@(-US) 8 E2E-X18ME@/F@ 8
M8 E2E-X2D@-M1(G) 9 E2E-X1R5E/F@-M1 9
M12 E2E-X3D@-M1(G) 11 E2E-X2E/F@-M1 11
Shielded
M18 E2E-X7D@-M1(G) 13 E2E-X5E/F@-M1 13
Connector Models M30 E2E-X10D@-M1(G) 15 E2E-X10E/F@-M1 15
(M12) M8 E2E-X4MD@-M1(G) 10 E2E-X2ME/F@-M1 10
M12 E2E-X8MD@-M1(G) 12 E2E-X5ME/F@-M1 12
Unshielded
M18 E2E-X14MD@-M1(G) 14 E2E-X10ME/F@-M1 14
M30 E2E-X20MD@-M1(G) 16 E2E-X18ME/F@-M1 16
Connector Models Shielded E2E-X2D@-M3G 17 E2E-X1R5E/F@-M3 17
M8
(M8) Unshielded E2E-X4MD@-M3G 18 E2E-X2ME/F@-M3 18
E2E-X2D@-M1TGJ
M8 19
E2E-X2D@-M1TGJ-US
E2E-X3D@-M1(T)GJ
M12 20
E2E-X3D@-M1TGJ-US
Shielded ---
E2E-X7D@-M1(T)GJ
M18 21
E2E-X7D@-M1TGJ-US
E2E-X10D@-M1(T)GJ
Pre-wired Connector M30 22
E2E-X10D@-M1TGJ-US
Models
M8 E2E-X4MD@-M1TGJ-US 23
E2E-X8MD1-M1(T)GJ
M12 24
E2E-X8MD@-M1TGJ-US
Unshielded E2E-X14MD1-M1(T)GJ ---
M18 25
E2E-X14MD@-M1TGJ-US
E2E-X20MD1-M1(T)GJ
M30 26
E2E-X20MD@-M1TGJ-US

Pre-wired Connector M12 E2E-X3D1-M1J-T 20


Models Shielded M18 E2E-X7D@-M1J-T 21 ---
(no polarity) M30 E2E-X10D@-M1J-T 22
Note 1. Two clamping nuts and one toothed washer are provided with M8 to M30 Models.
2. The model numbers of M8 to M30 Pre-wired Models are laser-marked on the milled section and cable section.

20
E2E
Note: DC 2-Wire Models have been integrated into the E2E NEXT Series at the end of october 2022. DC 3-Wire
Models have been discontinued at the end of March 2022. Refer to the catalog (Cat. No. D120) for details.

Pre-wired Models (Shielded) Pre-wired Models (Unshielded)

Diagram 1 E2E-X2D@ Diagram 2 E2E-X4MD@


E2E-X1R5E@/F@ E2E-X2ME@/F@
30 7 30 7
15 dia. 15 dia.
26 26
13 3 8 13 6 3 8

6.1 dia.
*1
Indicators *2 *1
M8 u1 Two clamping nuts M8 u1 Indicators *2
Toothed washer Two clamping nuts
Toothed washer
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.3 mm), Standard length: 2 m *1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m
1.3 mm), Standard length: 2 m 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
Robotics Cable Models: 1.3 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: Robotics Cable Models:
1.27 mm), Standard length: 2 m 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27 mm), Standard length: 2 m
1.27 mm), Standard length: 2 m 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
Models with Highly Oil-resistant Cables: 1.27 mm), Standard length: 2 m
4-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator The cable can be extended up to 200 m (separate metal conduit).
diameter: 1.3 mm), Standard length: 2 m *2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)
The cable can be extended up to 200 m (separate metal conduit).
*2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)

Diagram 3 E2E-X3D@ Diagram 4 E2E-X8MD@


E2E-X2E@/F@ E2E-X5ME@/F@
21 dia. 38 9 21 dia. 38 9
33 33
17 17
4 10 7 4 10

9 dia.
*1 *1
Indicators * 2 Indicators *2
M12 u1 Two clamping nuts M12 u1 Two clamping nuts
Toothed washer Toothed washer
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: *1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.3 mm), Standard length: 2 m 1.3 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.3 mm), Standard length: 2 m 1.3 mm), Standard length: 2 m
Robotics Cable Models: Robotics Cable Models:
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.27 mm), Standard length: 2 m 1.27 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.27 mm), Standard length: 2 m 1.27 mm), Standard length: 2 m
Models with Highly Oil-resistant Cables: The cable can be extended (separate metal conduit) up to 200 m for the control output and up to 100 m for
4-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator the diagnostic output.
diameter: 1.3 mm), Standard length: 2 m *2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)
The cable can be extended (separate metal conduit) up to 200 m for the control output and up to 100 m for
the diagnostic output.
*2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)

Mounting Hole Dimensions

Dimension M8 M12
F (mm) 8.5 +0.5
0 dia. 12.5 +0.5
0 dia.
F

21
E2E
Note: DC 2-Wire Models have been integrated into the E2E NEXT Series at the end of october 2022. DC 3-Wire
Models have been discontinued at the end of March 2022. Refer to the catalog (Cat. No. D120) for details.

Pre-wired Models (Shielded) Pre-wired Models (Unshielded)

Diagram 5 E2E-X7D@/E2E-X5E@/F@ Diagram 6 E2E-X14MD@/E2E-X10ME@/F@


43 12 43 12
29 dia. 29 dia. 38
38
24 4 10 24 10 4 10

14.8 dia.
*1 *1 *1
Indicators *2 Indicators *2
M18 u1 M18 u1
Two clamping nuts Two clamping nuts
Toothed washer Toothed washer

*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, *1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m Insulator diameter: 1.9 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m Insulator diameter: 1.9 mm), Standard length: 2 m
Robotics Cable Models: Robotics Cable Models:
6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m Insulator diameter: 1.74 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m Insulator diameter: 1.74 mm), Standard length: 2 m
Models with Highly Oil-resistant Cables: The cable can be extended (separate metal conduit) up to 200 m for the control output
6-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: and up to 100 m for the diagnostic output.
0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m *2. D1 Models: Operation indicator (red), Setting indicator (green)
The cable can be extended (separate metal conduit) up to 200 m for the control output D2/E/F Models: Operation indicator (red)
and up to 100 m for the diagnostic output.
*2. D1 Models: Operation indicator (red), Setting indicator (green)
D2/E/F Models: Operation indicator (red)

Diagram 7 E2E-X10D@/E2E-X10E@/F@ Diagram 8 E2E-X20MD@/E2E-X18ME@/F@


48 12 48 12
42 dia.
43 42 dia. 43
36 5 10 36 13 5 10

26.8 dia.
*1
*1
Indicators *2
Indicators *2
M30 u1.5
Two clamping nuts M30 u1.5
Toothed washer Two clamping nuts
Toothed washer
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, *1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m Insulator diameter: 1.9 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m Insulator diameter: 1.9 mm), Standard length: 2 m
Robotics Cable Models: Robotics Cable Models:
6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m Insulator diameter: 1.74 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m Insulator diameter: 1.74 mm), Standard length: 2 m
Models with Highly Oil-resistant: The cable can be extended (separate metal conduit) up to 200 m for the control output
6-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: and up to 100 m for the diagnostic output.
0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m *2. D1 Models: Operation indicator (red), Setting indicator (green)
The cable can be extended (separate metal conduit) up to 200 m for the control output D2/E/F Models: Operation indicator (red)
and up to 100 m for the diagnostic output.
*2. D1 Models: Operation indicator (red), Setting indicator (green)
D2/E/F Models: Operation indicator (red)

Mounting Hole Dimensions

Dimension M12 M18 M30


F (mm) 12.5 +00.5 dia. 18.5 +00.5 dia. 30.5 +00.5 dia.

22
E2E
Note: DC 2-Wire Models have been integrated into the E2E NEXT Series at the end of october 2022. DC 3-Wire
Models have been discontinued at the end of March 2022. Refer to the catalog (Cat. No. D120) for details.

M8 Connector Models M8 Connector Models


(Shielded) (Unshielded)

Diagram 17 E2E-X2D@-M3G/E2E-X1R5E@-M3/X1RF@-M3 Diagram 18 E2E-X4MD@-M3G/E2E-X2ME@-M3/X2MF@-M3


39 39
31 31
15 dia. 26 15 dia.
26
13 3 8 M8 u1 13 6 3 8 M8 u1
* D Models: Operation indicator (red),
Setting indicator (green) * D Models: Operation indicator (red),
6.1 dia. Setting indicator (green)
D2/E/F Models: Operation indicator (red)
M8 u1 Indicators* D2/E/F Models: Operation indicator (red)
M8 u1 Indicators*
Two clamping nuts
Toothed washer Two clamping nuts
Toothed washer

M12 Connector Models M12 Connector Models


(Shielded) (Unshielded)

Diagram 9 E2E-X2D@-M1(G) Diagram 10 E2E-X4MD@-M1(G)


E2E-X1R5E@-M1/E2E-X1R5F@-M1 E2E-X2ME@-M1/E2E-X2MF@-M1
43 43
30 30
15 dia. 15 dia.
26 26
M12 u1
13 3 8 M12 u1 13 6 3 8

6.1 dia.

M8 u1 Indicators* M8 u1 Indicators*


Two clamping nuts Two clamping nuts
Toothed washer
Toothed washer
* D1 Models: Operation indicator (red),
* D1 Models: Operation indicator (red),
Setting indicator (green)
Setting indicator (green)
D2/E/F Models: Operation indicator (red)
D2/E/F Models: Operation indicator (red)

Diagram 11 E2E-X3D@-M1(G) Diagram 12 E2E-X8MD@-M1(G)


E2E-X2E@-M1/E2E-X2F@-M1 E2E-X5ME@-M1/E2E-X5MF@-M1
48 48
21 dia. 33 21 dia. 33
17 4 10 17 7 4 10 M12 u1
M12 u1

9 dia.

M12 u1 Indicators * Indicators*


Two clamping nuts M12 u1
Two clamping nuts
Toothed washer Toothed washer
* D1 Models: Operation indicator (red), * D1 Models: Operation indicator (red), Setting indicator (green)
Setting indicator (green) D2/E/F Models: Operation indicator (red)
D2/E/F Models: Operation indicator (red)

23
E2E
Note: DC 2-Wire Models have been integrated into the E2E NEXT Series at the end of october 2022. DC 3-Wire
Models have been discontinued at the end of March 2022. Refer to the catalog (Cat. No. D120) for details.

Diagram 13 E2E-X7D@-M1(G)/E2E-X5E@-M1/X5F@-M1 Diagram 14 E2E-X14MD@-M1(G)/E2E-X10ME@-M1


X10MF@-M1
53
53
29 dia. 29 dia. 38
38
4 10
24 4 10 24 10
M12 × 1
M12 × 1

14.8 dia.

Indicators* Indicators*
M18 × 1 M18 × 1
Two clamping nuts Two clamping nuts
Toothed washer Toothed washer
* D1 Models: Operation indicator (red), Setting indicator (green) * D1 Models: Operation indicator (red), Setting indicator (green)
D2/E/F Models: Operation indicator (red) D2/E/F Models: Operation indicator (red)

Diagram 15 E2E-X10D@-M1(G)/E2E-X10E@-M1/X10F@-M1 Diagram 16 E2E-X20MD@-M1(G)/E2E-X18ME@-M1/


X18MF@-M1
58 58
42 dia. 43 42 dia. 43
36 5 10 36 13 5 10

26.8 dia.

M12 × 1 M12 × 1
Indicators* Indicators*
M30 × 1.5 M30 × 1.5
Two clamping nuts Two clamping nuts
Toothed washer Toothed washer
* D1 Models: Operation indicator (red), Setting indicator (green) * D1 Models: Operation indicator (red), Setting indicator (green)
D2/E/F Models: Operation indicator (red) D2/E/F Models: Operation indicator (red)

Mounting Hole Dimensions

Dimensions M8 M12 M18 M30


F (mm) 8.5 +00.5 dia. 12.5 +00.5 dia. 18.5 +00.5 dia. 30.5 +00.5 dia.
F

24
E2E
Note: DC 2-Wire Models have been integrated into the E2E NEXT Series at the end of october 2022. DC 3-Wire
Models have been discontinued at the end of March 2022. Refer to the catalog (Cat. No. D120) for details.

Pre-wired Connector Models (Shielded)

Diagram 19 E2E-X2D1-M1TGJ
30 7
E2E-X2D@-M1TGJ-US 15 dia. 26
13 8
3

*1
Indicators *2
M8 u1 M12 u1
Two clamping nuts
Toothed washer *1. 4-dia. Vinyl-insulated round cable,
Standard length: 300 mm
*2. D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)

Diagram 20 E2E-X3D@-M1GJ
38 9
E2E-X3D1-M1J-T 21 dia. 33
E2E-X3D1-M1TGJ 17 4 10
E2E-X3D@-M1TGJ-US

*1

M12 u1 Indicators *2 M12 u1


Two clamping nuts
*1. 4-dia. Vinyl-insulated round cable,
Toothed washer Standard length: 300 mm
*2. D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)

Diagram 21 E2E-X7D@-M1GJ 43 12
29 dia.
E2E-X7D@-M1J-T 38

E2E-X7D1-M1TGJ 24 4 10

E2E-X7D@-M1TGJ-US

*1
Indicators *2 M12 u1
M18 u1
Two clamping nuts *1. 6-dia. Vinyl-insulated round cable,
Toothed washer Standard length: 300 mm
*2. D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)

Diagram 22 E2E-X10D@-M1GJ
48 12
E2E-X10D@-M1J-T 42 dia.
43
E2E-X10D1-M1TGJ 36 5 10
E2E-X10D@-M1TGJ-US

*1
M12 u1
Indicators *2
M30 u1.5
Two clamping nuts *1. 6-dia. Vinyl-insulated round cable,
Standard length: 300 mm
Toothed washer *2. D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)

25
E2E
Note: DC 2-Wire Models have been integrated into the E2E NEXT Series at the end of october 2022. DC 3-Wire
Models have been discontinued at the end of March 2022. Refer to the catalog (Cat. No. D120) for details.

Pre-wired Connector Models (Unshielded)

Diagram 23 E2E-X4MD@-M1TGJ-US 30 7
15 dia.
26
13 6 3 8

6.1 dia.
*1
Indicators *2
M8 u 1 M12 u 1
Two clamping nuts
Toothed washer *1. 4-dia. vinyl-insulated round cable
Standard length: 300 mm
*2. D1 Models: Operation indicator (red),
Setting indicator (green)
D2 Models: Operation indicator (red)

Diagram 24 E2E-X8MD1-M1GJ 38 9
E2E-X8MD1-M1TGJ 21 dia. 33
E2E-X8MD@-M1TGJ-US 17 7 4 10

9 dia.
*1
Indicators *2 M12 u1
M12 u1 Two clamping nuts
*1. 4-dia. vinyl-insulated round cable,
Toothed washer Standard length: 300 mm
*2. D1 Models: Operation indicator (red),
Setting indicator (green)
D2 Models: Operation indicator (red)

Diagram 25 E2E-X14MD@-M1GJ 43 12
E2E-X14MD1-M1TGJ 29 dia.
38
4 10
E2E-X14MD@-M1TGJ-US 10
24

14.8 dia.
*1
Indicators*2 M12 u1
M18 u1 *1. 6-dia. vinyl-insulated round cable,
Two clamping nuts
Standard length: 300 mm
Toothed washer *2. D1 Models: Operation indicator (red),
Setting indicator (green)
D2 Models: Operation indicator (red)

Diagram 26 E2E-X20MD1-M1GJ 42 dia.


48 12
43
E2E-X20MD1-M1TGJ 36 13 5 10
E2E-X20MD@-M1TGJ-US

26.8 dia.
*1
M12 u1
Indicators*2
M30 u1.5 *1. 6-dia. vinyl-insulated round cable,
Two clamping nuts Standard length: 300 mm
Toothed washer *2. D1 Models: Operation indicator (red),
Setting indicator (green)
D2 Models: Operation indicator (red)

Mounting Hole Dimensions

Dimension M8 M12 M18 M30


F (mm) 8.5 +00.5 dia. 12.5 +00.5 dia. 18.5 +00.5 dia. 30.5 +00.5 dia.
F

26
E2E
Note: DC 2-Wire Models have been integrated into the E2E NEXT Series at the end of october 2022. DC 3-Wire
Models have been discontinued at the end of March 2022. Refer to the catalog (Cat. No. D120) for details.

Dimensions for Proximity Sensors with Sensor I/O Connectors


Shielded Models Unshielded Models Dimensions with the XS2F/XS5F Connected (Unit: mm)
Dimension
Straight Connectors Straight Connectors L1 L2
Sensor diameter
M8 Approx. 75 Approx. 62
DC Approx. 80 Approx. 67
L1 L1
M12*
AC Approx. 85 Approx. 72
L-shape Connectors L-shape Connectors M18 Approx. 85 Approx. 72
M30 Approx. 90 Approx. 77
* The overall length of the Sensor is different between AC and DC Models for
Sensors with diameters of M12. This will change the dimension when the I/
O Connector is connected.

Dimensions with the XS3F Connected (Unit: mm)


Dimension
L2 L2 L1 L2
Sensor diameter
M8 Approx. 65 Approx. 54

Accessories (Order Separately)


Sensor I/O Connectors
Refer to Introduction to Sensor I/O Connectors/Sensor Controllers for details.

Mounting Brackets
Protective Covers
Sputter Protective Covers
Refer to Y92@ for details.

27
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.

Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing
by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s
election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof)
the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase
price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any
other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled,
stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any
Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability
or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in
writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.

Limitation on Liability; Etc.


OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.

Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.

Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.

Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.

Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.

Errors and Omissions.


Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
Note: Do not use this document to operate the Unit.
OMRON Corporation Industrial Automation Company Authorized Distributor:
Kyoto, JAPAN Contact : www.ia.omron.com
Regional Headquarters

OMRON EUROPE B.V. OMRON ELECTRONICS LLC


Wegalaan 67-69, 2132 JD Hoofddorp 2895 Greenspoint Parkway, Suite 200
The Netherlands Hoffman Estates, IL 60169 U.S.A.
Tel: (31) 2356-81-300 Fax: (31) 2356-81-388 Tel: (1) 847-843-7900 Fax: (1) 847-843-7787

OMRON ASIA PACIFIC PTE. LTD. OMRON (CHINA) CO., LTD. ©OMRON Corporation 2023 All Rights Reserved.
438B Alexandra Road, #08-01/02 Alexandra Room 2211, Bank of China Tower, In the interest of product improvement,
Technopark, Singapore 119968 200 Yin Cheng Zhong Road, specifications are subject to change without notice.
Tel: (65) 6835-3011 Fax: (65) 6835-2711 PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222 Fax: (86) 21-5037-2200 Cat. No. D126-E1-01 0323 (0323)