Bently Nevada Orbit 60 Series System Datasheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 34

Orbit 60 Series System

Datasheet
Bently Nevada Machinery Condition Monitoring 137M5182 Rev. H

Plant-wide • One System


The Orbit 60 Series Protection and Condition Monitoring
System provides one continuous, online monitoring
system for both critical and plant-wide applications.

Cyber Secure • Data Isolation


Orbit 60 Series data isolation creates a safe industrial data
environment designed to meet ISA 62443 with world class
network security features and segregation of protection
and condition monitoring functions.

Modular • Flexible • Scalable


The Orbit 60 Series system may be deployed in any
combination of rackmounted and distributed hardware.
This provides for better alignment of instrumentation to
the machinery application.

High Speed Process Data Integration


Next generation architecture facilitates full bi-directional
communications with plant control systems over a suite
of standard protocols.

Extended Field Wiring Length


With the Orbit 60 Series distributed architecture,
connection of multiple chassis through Bridge modules
decreases overall electrical installation costs, reduces
analog ground loops and noise issues, and moves key
maintenance activities further from hazardous areas.

Industry Leading System Capabilities


The Orbit 60 Series is designed to support monitoring of
*Embedded display will not be available in first release. single machine trains or mulitple machines in a single
deployment. Each system is defined by one System
Interface Module (SIM) and can encompass up to 80
dynamic channels and 10 chassis using Bridge modules to
link them.
Orbit 60 Series System
Datasheet 137M5182 Rev. H

System Overview
The Orbit 60 Series Protection and Condition Monitoring System provides a single platform for the
continuous online monitoring of both critical and plant-wide applications. The Orbit 60 Series system
may be deployed in any combination of rackmounted and distributed hardware, with Bridge
modules creating a seamless connection between chassis to make a single system.
The table below gives a general overview of the components that make the Orbit 60 platform. They
are grouped into System Modules, Input Modules, and Output Modules.
Table 1:  Component Modules

System Chassis 19" Chassis - 3U high - 19 general purpose slots


Modules 19" Chassis - 6U high - 28 general purpose slots
User Guide 12" Chassis - 3U high - 10 general purpose slots
(142M9080)
Power Power Interface Module (PIM)

Processors System Interface Module (SIM)


Protection Processing Module (PPM)
Condition Monitoring Module (CMM)

Comms Bridge (BRG)


Communication Gateway (CGW)
- Modbus (Serial or Ethernet) or EGD (Ethernet)

Input Dynamic Negative Dynamic Input


Modules (provides power for negatively powered transducers)
(4
User Guide channels)  l Prox, Accel, Velom (PAV )
(137M0804)
 l Prox, Accel, Seismic (PAS)
 l Prox, Accel, Aero (PAA)
 l Prox, Accel, DC LVDT (PAD)
 l High Speed Keyphasor (KPH)
Positive Dynamic Input (PVT)
(provides power for positively powered transducers)
AC LVDT

Static RTD/TC Temperature (RTD)


Isolated TC Temperature (ITC)
(6 Isolated Discrete Input or Process Variable (PVD)
channels)

Output Relays Electro-Mechanical Relays (EMR)


Modules Solid State Relays (SSR)
User Guide
(137M0803) Rec Outs Recorder Outputs (REC) (4-20 mA, 1-5 Vdc or 0-10 Vdc)

Display External Display

2/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

Orbit 60 System Level Diagram

SIM - System Interface Module S1 - System 1 Server or Client


CMM - Condition Monitoring Module CNFG - Orbit Studio Configuration Software
CGW - Comm Gateway Module DCS/PLC - Distributed Control Systems/
Programmable Logic Controller
BRG - Bridge Module
L1 - Unit Network L4 - Business Network

One System Interface Module (SIM) defines a system of up to 80 dynamic channels, accommodating
multiple machine trains and supporting unrestricted synchronous Keyphasors for any channel. The
Condition Monitoring Module (CMM) interfaces to the business network through a cyber secure
access port. The Communications Gateway (CGW) sends and receives high speed, bi-directional
process data with the control systems. Bridged (BRG) connections make up to 10 chassis act as a
single system while decreasing overall installation costs, reducing ground loops, and minimizing
electrical noise.

3/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

Orbit 60 Series Chassis


Each chassis option can be deployed flexibly with a public facing side (for rack or panel mounts) and
a utility side (for wiring connections and bulkhead mounts). Modules are inserted and all wiring
connections made from the utility side. The public side of the chassis is provisioned for status LEDs,
configuration port, Config/Run key, and reset button. Chassis are available in three types: 3U 12" 10
slot, 3U 19" 19 slot, and 6U 19" 28 slot.

Chassis Types

*Embedded display will not be available in first release.

Mounting Options
 l Panel Mount – Mounts to rectangular cutouts in panels and secures to the panel using clamps
supplied with the chassis in 3U 12" half-size, 3U 19" standard, and 6U 19" standard configurations.
The 6U 19" will fit in the space of a 3500 rack.

 l Rackmount – Mounts the 3U or 6U chassis on 19-inch EIA rails. Two 3U units or a single 6U form
factor has been designed to fit within the space of a single 19” rackmount 3500 unit, as a retrofit.

 l Bulkhead - Typically mounts into a protective enclosure fastened to a sub panel in 3U 12", 3U 19"
standard, and 6U 19" standard configurations. NEMA 4 and 4X weatherproof housings are
available when required for environmental protection or when purge air is used.

4/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

System Interface Module


A single System Interface Module (SIM) is required to define a system, whether it is just
one chassis or if the system bridges across multiple chassis. The SIM occupies one slot
and must be adjacent to the Power Input Module (PIM) in a panel or rackmount chassis.
The SIM controls protection configuration management, local display, system-level
diagnostics, system LEDs, system contacts, and the system protection fault relay.
The System Interface Module is the access point for configuring and maintaining the
system. The module will communicate to the configuration utility and transmit the
configuration to the other modules in the system. A key-lock switch on the public side of the SIM
secures the system configuration, preventing unauthorized changes to the configuration settings.
The LED indications for POWER 1 / POWER 2 show PIM status. The SIM LED indicates SIM is installed in the
correct slot and operational.

Contacts and Communications


RST - Reset Contact or Used to clear all latched alarms and NOT OK
Button statuses across the system.
INHB - System Alarm Used to inhibit all alarms within the system.
Inhibit Contact
TM - Trip Multiply Used to place the system in Trip Multiply.
Contact
LOCK - Configuration PRG - Allows configuration changes to be
Lock Contact or Key made to the system.
RUN - Locks the system, blocking
configuration changes.

Protection Fault Relay Indicates that all the protection functions


within the system are operational.

Ethernet Ports: 3 Ethernet ports for configuration of the


1 public side system or data feed to the display module.
2 utility side

LED Indications

OK Indicates the operational status of the module.

LINK Internal Communication LED - successful communication on


the internal network.

ATTN Attention LED - compromised protection path or


unacknowledged system events.

INHB Inhibit LED - one or more configured alarming functions have


been inhibited.

5/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

LED Indications

LOCK Indicates the system is in Run mode.

RST Reset LED, indicates reset contact closed.

TM Trip Multiply LED indicates that the system is in Trip Multiply mode.

Fault System Fault Relay - Indicates the state of the alarming functions within the system.

Protection Processing Module


The Protection Processing Module (PPM) serves as the computational engine for the
protection system, extracting all machinery measurements for the protection system
and performs alarm determinations. The PPM analyzes signals from transducers, as well
as process data through the Communications Gateway Module (CGW). Each module
occupies a single slot within the system.
 

The number of channels supported by each PPM is a function of the type of processing
required on the data. For example, in Turbomachinery applications, one PPM can typically
support up to 80 dynamic channels. You can add multiple PPMs to the system to provide
additional processing capability or to provide redundancy in protection applications.

6/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

Condition Monitoring Module


The Condition Monitoring Module (CMM) is the data acquisition and storage
module for the system. It is a specialized computational engine designed to
support condition monitoring applications and communications between
System 1 Condition Monitoring software and Orbit 60 Series modules.

The CMM module receives all data produced by the system through a one-
way information stream from the chassis. This allows the CMM to interface
with business tier or remotely hosted networks to provide data to the host
software without placing the protection functions at risk from cyberattacks.
The CMM listens to all information on the system chassis, including all
measurements, waveforms, digital transducer signals, system controls,
status information, system configuration information, process data from
external systems, alarm and events logs.
Each module occupies two slots within the system. Multiple CMM modules
can be placed into a system to allow additional processing power, multiple
users independent access, or for redundant communications to System 1.
The CMM performs all data capture functions such as alarm and transient
captures. The historical data is buffered in non-volatile storage until the
information is offloaded to the host software. System 1 can configure the
CMM module to extract additional measurements and waveforms from
system sensor data.
Each module has two independently configurable RJ-45 ethernet ports. The
module OK LED indicates when the module is functioning properly and the
LINK LED indicates when the module is communicating to the rest of the
system.

7/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

Communication Gateway Module


The Communication Gateway Module (CGW) module provides information to external
hosts including: measurements, alarms, statuses, and configuration information using
standard industrial protocols. The CGW is designed to be used as part of a protection
loop.

Through the Communication Gateway module, the system can acquire process data
from external control systems, human interfaces, and historians. The data can also be
acted on by the Condition Monitoring Module and passed through to System 1. The
Communication Gateway module occupies a single slot.
There are two versions of the CGW module:

 l Serial - Two RS-485 ports supporting Modbus protocol


 l Ethernet - Two RJ-45 ethernet ports supporting Modbus and EGD protocols
The module OK LED indicates when the module is functioning properly and the LINK LED
indicates when the module is communicating to the rest of the system.

8/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

Bridge Module (BRG)


The base-to-base Bridge module connects multiple chassis to make a distributed
system. Bridge connectivity enables flexible deployments in linear or star topologies. This
system significantly reduces field wiring cost, especially when extending to remote
locations. Each Bridge module communicates all data in the local chassis and replicates
to the remote chassis. In this way, all data within the system is communicated to all
devices in the system.

The Bridge module provides protection from incompatible networks interfering with the
operation of the system by blocking any transmissions from non-approved sources
onto the chassis.
The module OK LED indicates when the module is functioning properly and the LINK LED
indicates when the module is communicating to the rest of the system.
To link chassis together within a system, each chassis must contain at least one Bridge
module, depending upon the number of connections. Bridge modules are connected
using triple redundant cabling to ensure that a faulted cable does not affect operation
of the system. The Bridge module occupies a single slot.
There are three cables between the two bridge modules, one in each chassis. These
cables are for redundancy both for intermittent packet failures and for failure of a cable.
All three cables must go between the same two bridges and are required for protection
applications, single connections are only allowed for condition monitoring only
applications. Multiple bridge modules connecting the same two chassis is not
supported. The loss of a cable will cause a fault indication, but the system will still
function even if only a single cable is functional. The fault indication will be enunciated
by the Attention status and Protection Fault if the protection path crosses the bridge.
The recommended wiring method is to run these three cables separate from each other
so all three will not be damaged in particular circumstances. The three cables between
the bridges must be close to the same length to avoid differences in propagation timing
between the three paths.
The cables used are IX Ethernet cables. Even though the cables are IX Ethernet the traffic
between the two bridge modules is not compatible with Ethernet Switches and Routers
and can not be connected to an Ethernet network. If the bridge detects that there is
traffic other than the expected bridge to bridge messages, it will shut down
communication and indicate a fault. The initial release of the product will have copper IX
Ethernet cables that have a maximum length of 100M. Future releases of the product will
have an option for Fiber Optic bridge modules to extend the length of the connection.

9/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

Power Input Module


The Power Input Module (PIM) always resides in a special-purposed slot located in the first slot of the
chassis. Every chassis must be powered through at least one PIM and each chassis requires its own
PIMs and power sources. Redundant PIMs and power sources are strongly recommended.
The PIM is a half-height module that connects an external power source
to the system. Each Orbit 60 Series chassis supports two stacked
redundant power input modules. When both power inputs are utilized,
failure of one power source does not affect the operation of the system.
The PIMs support input voltages ranging from +21 Vdc to +32 Vdc. The
most common power source comes from external DIN rail mounted
AC/DC +24 Vdc output power supplies. Connections to Instrument
Common and Protective Earth are available.
You can remove and insert a single Power Input Module without
disrupting system operation as long as another PIM remains installed and
connected to its input power source.
The PIM employs out-of-range protection for mis-wiring, over voltage,
and over current protection for the input power sources.
The Instrument Common and Protective Earth connections for the
system are made at the utility side of the PIM.

LED Indications

POWER 1 (public side) Upper power input is powering the system.

POWER 2 (public side) Lower power input is powering the system.

Module OK LED Indicates when the power source connected to the PIM is within the
(utility side of each appropriate range. Under voltage lockout keeps the system from turning on
module) and will not cause damage. Extreme over voltage will cause PIM fuse to open.

Connections

Voltage +21 Vdc to +32 Vdc

IS Instrument Common

PE Protective Earth

10/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

Transducer Input Modules


The Orbit 60 Series system interfaces to multiple transducer types. The system also provides short
circuit protected power for transducers that require power.
Table 1:  Table 2: Supported Transducer Types

Number Input Number


Input Module Supported Transducer Supported
of Module of
Type Types Transducers Types
Channels Type Channels

Negative 3-wire (-)Accel 4 Positive 3-wire (+) Accel 4


Dynamic Voltage
Input (PAV) 3-wire (-) Prox Dynamic 3-wire (+) Prox
2-wire Velomitor Input 2-wire IEPE
Prox, Accel, (PVT)
Velom 2-wire IEPE
Magnetic pickup

Negative 3-wire (-) Accel 4 High 3-wire Accel 4


Dynamic Speed
Input (PAS) 3-wire (-) Prox 3-wire Prox
Keyphasor
Prox, Accel, Seismoprobe Magnetic pickup
Seismic Magnetic pickup 4-wire AC LVDT
AC LVDT 4
Input 5-wire AC LVDT
6-wire AC LVDT

Negative 3-wire (-) Accel 4 RTD / TC Type J, K, E, T 6


Dynamic Input
Input (PAA) 3-wire (-) Prox 3-wire RTD

Proximity, Magnetic pickup


Accel, Aero HTVAS Isolated TC Type J, K, E, T 6
Acceleration Interface Input
Module

Negative 3-wire (-) Prox 4 Isolated 4-20 mA 6


Dynamic Discrete
Input (PAD) 3-wire (-) Accel -10 V to +10 V
Input
Proximity, DC LVDT /Process Dry/wet contacts
Accel, DC Variable
LVDT

11/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

Dynamic Input Modules


The primary purpose of the Dynamic Input module is to digitize the sensor signal at a
rate that completely encompasses the signal content and provides transducer
power for various sensors. The Orbit 60 Series Dynamic Input module is a 4-channel
input module available in both negative and positive dynamic input options. The
inputs can also be used for speed or Keyphasor signals.
 

Negative Transducer Input Module


These cards are designed to work with negative voltage external sensors offering four variants:

 l PAV Negative Dynamic Sampler (Prox, Accel, Velom) - This module


accommodates more than 80% of available input sensors allowing greater
flexibility with one firmware enabled module.
 l PAS Negative Dynamic Sampler (Prox, Accel, Seismic)
 l PAA Negative Dynamic Sampler (Prox, Accel, Aero)
 l PAD Negative Dynamic Sampler (Prox, Accel, DC LVDT)

Positive Transducer Input Module


The Positive Voltage (PVT) input module interfaces with industry standard third-party
ICP sensors, as well as sensors that use a 3 wire(power, common, signal) or 2 wire ( A/+
and B/-) positive voltage interface.

 l PVT Positive Dynamic Sampler (Prox, Accel, Velom)


The Dynamic Input module uses an ix Industrial connection to provide access to four
buffered transducer output (BTO) connectors. The BTO connection is available on the
public and utility side of the module.

12/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

High Speed Keyphasor Input Module


Unlike previous systems, the Orbit 60 Series system supports Keyphasor configurations
for any dynamic input channel through the PAV, PAS, PAA, and PAE input modules. For
high phase accuracy applications, over 12,000 rpm, the isolated high speed Keyphasor
module can be applied, supporting four transducer inputs per module. Inputs to this
module can also be configured as prox vibration inputs. The Keyphasor input module
occupies a single slot.
Any channel on the module can be configured as a once per turn Keyphasor or a multiple
event per turn speed signal from a rotating shaft or gear used to provide a precision timing
measurement. The Keyphasor Input Module is designed to work with the following
transducers:

 l Magnetic pickup
 l 3-wire Prox
 l 3-wire Accel
The module creates the Keyphasor signal when the sensor reads a notch or protrusion in the
target. The signal is digitized and processed to provide machine rotative speed and vector
parameters, such as 1X amplitude and phase. The Keyphasor gives phase reference
information for a vibration measurement, providing key relationships for diagnostic analysis.
The module OK LED indicates when the module is functioning properly and the LINK LED
indicates when the module is communicating to the rest of the system. Four Channel Status
LEDs located on the utility side of the module indicate when the connected sensor is installed and in
OK condition.

AC LVDT Input Module


The Orbit 60 Series AC LVDT Input Module provides inputs to interface to four AC Linear
Variable Differential Transformers for position measurements. It is mainly used for
measurement of case expansion and valve position. The AC LVDT input module
occupies a single slot.
 

The AC LVDT configured channels can be connected to:

 l 4-wire AC LVDT
 l 5-wire AC LVDT
 l 6-wire AC LVDT
The module OK LED indicates when the module is functioning properly and the LINK LED
indicates when the module is communicating to the rest of the system. Four Channel Status
LEDs located on the utility side of the module indicate when the connected sensor is installed
and in OK condition.

13/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

Dynamic Input Module Sensors and Measurements


Table 1:  Table 3: List of Sensors, Measurements, Modules, Barriers, and Isolators

Dynamic Input Module Type


Sensor Type AC External Galvanic
Measurement Type
Supported PAV PAS PAA PAD PVT LVDT KPH Barriers Isolators

Proximitor Displacement X X X X X   X 175502 397A8827


(3-wire) 397A8826
Accelerometer Acceleration* X X X X     X 175502 397A8827
(3-wire) 397A8826
HTVAS High-Temp Acceleration*, Velocity*     X         175502 397A8827
Velocity Accel 397A8826

86517 and 86497 Acceleration*, Velocity*,     X         175502 397A8827


Interface Modules Dynamic Pressure 397A8826

350500 Charge Dynamic Pressure X X X X       175502 397A8827


Amplifier 397A8826

350501 Charge Acceleration* X X X X       175502 397A8827


Amplifier 397A8826

Velomitor Velocity* X       X     177241 397A8827


(2-wire) 397A8826

Seismoprobe Velocity*   X           N/A N/A


(2-wire)

Proximitor Keyphasor Speed, Gap X X X X     X 175502 397A8827


(3-wire) 397A8826
IEPE Positive Constant Acceleration*, Velocity*,         X     176394 397A8827
Current (370300) (2- Dynamic Pressure 397A8826
wire)

Negative Biased Acceleration*, Velocity*, X             177241 397A8827


Constant Current (2- Dynamic Pressure 397A8826
wire)

DC LVDT Position       X       283615 N/A

AC LVDT Position           X   N/A N/A

Magnetic Speed Speed X X X X     X N/A N/A


Pickups

* These measurements can be integrated to provide additional measurement types.

14/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

Static Input Modules


The Orbit 60 Series static input modules (Temperature, Process Variables, Discrete)
provide six transducer connections per module. This module conditions and digitizes the
inputs at a rate that completely encompasses the signal content and allows for removal
of typical noise sources.
The three modules are:

 l RTD/TC Temperature Input Module (RTD)


 l Isolated TC Temperature Input Module (ITC)
 l Isolated Process Variable / Discrete Input Module (PVD)
The primary purposes of these modules are to:

 l Continuously process input from connected inputs to be compared against


configured alarm setpoints to drive alarms for machinery protection
 l Provide discrete inputs for essential operational commands, such as Trip Multiply
for machine start-up and Alarm Inhibit.
These modules occupy a single slot. The module OK LED indicates when the module is
functioning properly and the LINK LED indicates when the module is communicating to
the rest of the system. Six Channel Status LEDs located on the utility side of the module
indicate when the connected sensor is installed and in OK condition.

RTD/TC Temperature Input Module (RTD)


Each channel of the Orbit 60 Series RTD/TC input module is individually configurable for
sensor type and range. The thermocouple configured channels provide cold junction
compensation for type J, K, E, or T thermocouple. The RTD/TC inputs are referenced to the
internal system ground and for this reason should only be connected to transducers
that are isolated at the sensing end.

Isolated TC Input Module (ITC)


Each channel of the Orbit 60 Series Isolated TC input module is individually configurable
for sensor type and range. The thermocouple configured channels provide cold junction
compensation for type J, K, E, or T thermocouples.
The Isolated TC input module has the circuitry to isolate the inputs from both system
ground and channel to channel on the same module. This module is typically used for
any grounded tip thermocouple, often in electrical equipment applications.

Isolated Process Variable / Discrete Input Module (PVD)


The Orbit 60 Series Isolated Process Variable and Discrete Input module processes machine critical
parameters such as pressure, flow, temperature, and levels that merit continuous monitoring. The
module conditions and digitizes the signals so that the result can be compared with user-
programmable alarm setpoints. The user can program the PVD module using the Orbit Configuration
software to perform current, voltage or discrete input measurements.
The monitor accepts +4 to +20 mA current inputs or any proportional voltage inputs between -10 Vdc
and +10 Vdc, in addition to monitoring “dry” or “wet” contacts which can be a sensor, switch, or relay.

15/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

Recorder Outputs
The Recorder_Output module is a 8-channel module that converts measurements
within the Orbit 60 Series to a proportional current or voltage output that can be
connected to external systems for communications purposes. Recorder outputs can be
ordered in SIL rated versions.
Recorder_Output modules can be configured to represent any measurement provided
within the system. This module occupies a single slot.

These outputs adhere to Namur 43 specification and indicate Not OK conditions. This
module is available for SIL applications.

Output Types 4 to 20 mA
1 to 5 V
0 to 10 V

Signal Load for Current Output Load generally ≥ 100 Ω


Range: 0 to 600 Ω

Signal Load for Voltage Output 100 kΩ or higher

Maximum Current Load 22 mA

Short Circuit Protection A short circuit on any recorder output will not
impact adjacent recorder outputs.

Output Characteristics  n 1% signal output error


 n 1 ms default update rate
 n 10 ms maximum signal delay

The module OK LED indicates when the module is functioning properly and the LINK LED
indicates when the module is communicating to the rest of the system. The utility side of
the module shows eight Channel Status LEDs, which indicate the condition of each
channel.

16/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

Relay Modules
Relay modules provide a set of relays that can be programmed to actuate
based on alarm conditions defined in other modules. They are
programmable with standard logic elements to combine various alarms and
statuses into relay activation conditions. The voting logic can be configured
with AND and OR logic, utilizing alarming inputs from input modules, Not-OK
statuses, and individual measured values from any module in the system.
Use Orbit Studio to program the voting logic.

Relays can also be programmed to operate as system protection


fault relays, when the included protection fault relay on the SIM does
not provide adequate granularity of system health - typically for
multiple machines in one system.

Electromechanical Relay (EMR)

Used for applications where the relay is used to directly drive a load,
either directly or through an interposing relay. This module takes
two slots. It features 8 Single Pole Double Throw Electromechanical
Relays. This module Supports voltage range of 5V-240 Vac for load
of 100mA to 4.5A and DC voltages and loads as follows 5V-30VDC at
4.5A, 48VDC at 0.75A, and 125VDC at 0.2A.

Solid State Relay (SSR)

This relay is used for low current communication applications where


the relay is connected to a discrete input for an external system. It
only takes a single slot and features 8 Solid State Relays. This
module supports voltages up to 125 Vdc and loads of 1 mA to 125mA.
Pairs of relays within a module can be configured to function as a
single Double Pole Double Throw relay. All relay types are available
for SIL system implementation.

17/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

Display Options
There are two Orbit 60 Front Panel Module options.

Standard Front Panel Module Remote Front Panel Module

The standard Front Panel Module is for Orbit 60 The remote Front Panel Module is for Orbit 60
bases that have a SIM module installed. The bases that do not have a SIM module installed.
Standard Front Panel Module displays the status The Remote Front Panel displays the status of
of the power supplies, the presence of a SIM the power supplies.
Module, and whether the SIM Module is in Program
mode. The Front Panel Module can send program
and reset requests via the key switch and reset
buttons. The Front Panel Module provides an
Ethernet port from the SIM to the RJ45 jack, with
link and activity LEDs on the front of the Orbit 60
base.

External Display
The external display utilizes an industrial computer connected to the SIM via Ethernet, the computer
and display can be placed where needed for each application. The 10.4", 15", and 21.5" VGA
touchscreen displays are designed for excellent viewing quality in industrial applications. The
10.4" display is suitable for use in hazardous area locations across the world. The 15" display is certified
for hazardous areas for North America only.

Mounting Options
You can mount the displays in a remote enclosure, panel, or rack.
10.4" Display Can be mounted in a rack, panel, and enclosure.
15" Display Can be mounted in a rack, panel, and enclosure.
21.5" Display Can be mounted in a rack or panel.
If you want to use the 21.5" display, before ordering, verify that your 19" rack equipment enclosure can
contain the 21.5" display. If rack-mounted, you must be able to access the controls at the rear of the
21.5" display. The 21.5" display is 22" wide. When mounted, the display extends 1.5" beyond each side of
a 19" equipment rack. Doors, brackets, and other hardware must not interfere with the mounted
display. To accommodate the display, the rack must not extend forward more than 1.1".

18/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

Bently Nevada Industrial Computer


The Orbit 60 Series Industrial Computer is certified for hazardous environments when installed in a
NEMA3 or NEMA4 enclosure. The industrial computer uses a 64-bit OS to communicate with an Orbit
60 Base SIM module to gather and output data to supported displays. The small form factor (5.2 x 4.8
x 3.4 in (132 x 122 x 87 mm)) enables you mount it on a DIN-rail.

Display Content
By default, one bar graph screen shows all the primary measurements. Use the Orbit Studio
configuration software to create custom screens displaying additional information, machine train
groups, and system-wide data displays.

 l System event list


 l Alarm event list
 l All module and channel data
 l Alarm and OK status
 l Nine custom display options

System 1 Integration
Take full advantage of System 1 Condition Monitoring Software in conjunction with Orbit 60 Series for
complete monitoring and advanced diagnostics for all machine types, including roller element
bearings. Use the Orbit 60 Series Condition Monitoring Module (CMM) for a read-only access point to
provide a cyber secure approach for obtaining data through the business network or other systems.
When used in conjunction with the Comm Gateway module, high speed bi-directional process data
can be relayed to System 1 along with system generated data.
 

19/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

Orbit Studio Configuration Software


Multiple Systems Configuration

The Orbit Studio enables you to connect to multiple systems from a single client session, opening
multiple offline configuration files alongside active connected systems to allow for easy cross-
referencing across systems, while enabling security through user-based permissions. Copy and
paste functions apply across systems and configuration files. Perform send and retrieve operations
for multiple systems at a time.

Graphical System and Relay Configuration

Create and manage multiple pages of relay logic by graphically configuring, one channel per page,
with drag and drop elements and connectors. Your system can also be graphically assembled by
dragging and dropping components from a library of modules. The resulting assembly produces a
hierarchical representation of the system for access to individual channels.

Current Values and Loop Check

View current value data across all channels within a system. Loop checks can be performed via bar
graphs, tabular lists, and live plots for dynamic data, from channels throughout the system.

20/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H
 

Specifications
 

System Physical Dimensions

Orbit 60 System 3U Standard Chassis


Width 19" (48.26 cm) - with bezel
System Inputs
18.87" (47.93 cm) - panel
Voltage Input +21 to +32 Vdc mount without bezel
17.53" (44.53 cm) - rackmount
Current Draw without bezel

3U 19" full load 8.6 Amps max Height 5.2" (13.21 cm) - with bezel
6U 19" full load 14.3 Amps @ 24 Vdc max Depth 9.67" (24.56 cm)
3U 12" full load 5.3 Amps max
6U Standard Chassis
Power Consumption Width 19" (48.26 cm) - with bezel
18.87" (47.93 cm) - panel
3U 19" full load 120 Watts typical
mount without bezel
180 Watts max
17.53" (44.53 cm) - rackmount
6U 19" full load 160 Watts typical without bezel
300 Watts max
Height 10.47" (26.6 cm) - with bezel
3U 12" full load 70 Watts typical
110 Watts max Depth 9.67" (24.56 cm)

Out of Range An under voltage does not 3U 12" Chassis


Protection harm the PIM.
Width 11.44" (29.06 cm) - with bezel
An over voltage causes the
9.97" (25.32 cm) - w/o bezel
fuse to open.
Height 5.2" (13.21 cm) - with bezel
Chassis Loading No minimum chassis
loading is required. Depth 9.67" (24.56 cm)

System Weight Single Wide Module

3U 19" Chassis 32 lbs (14.5 kg) Width 0.8" (2.03 cm)

6U 19" Chassis 64 lbs (29.03 kg) Height 5.2" (13.21 cm)

3U 12" Chassis 18 lbs (8.16 kg) Depth 9.67" (24.56 cm)

  Double Wide Module

  Width 1.64" (4.17 cm)

  Height 5.2" (13.21 cm)


  Depth 9.67" (24.56 cm)
 
 

21/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

System Environmental SIM Controls

Operating -30° C to +70° C (-22° F to Reset Contact Used to clear all latched
Temperature 158° F) or Button alarms and NOT OK
Range statuses across system. 1
(indoor use
only) System Alarm Used to inhibit all alarms
Inhibit Contact within the system.
Storage -40°C to +85°C (-40° F to
Temperature 185° F) Trip Multiply Used to place the system in
Range Contact Trip Multiply.

Configuration PRG - Used to change


Relative 0% to 95% rH non-
Lock Contact or configuration. RUN - Locks
Humidity condensing operating and
Key the system, blocking
storage
configuration changes. 2
Vibration 5g @ 57-500 Hz. IEC 60068-
2-6 1Performed by either closing the contact on the
module or pressing the button on the front
Shock 10g, 11ms IEC 60068-2-27 panel.

Altitude < 2000 m (6,562 ft) 2 Performed by either closing the contact on
module or setting the key on the front to the
Pollution Pollution Degree 2 RUN setting on the front panel.
Degree
 
Installation Category II
Category Communications Gateway
 
(CGW)
System Interface Module(SIM) Communications Gateway (CGW)

SIM Inputs Power 14.2 Watts max

Data Two independent 10/100/1000


Data Three independent BaseT Auto-negotiation
10/100/1000 BaseT Auto-
negotiation
 
Cable Length 100 metres (328
feet) max Protection Processor Module
1 public side 2 utility side
(PPM)
Power 15.1 Watts maximum Protection Processor Module (PPM)
Consumption
Power 12.7 Watts max
Max Channels Up to 80 dynamic channels
with one SIM defining a  
system.
 

 
 

22/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

Dynamic Input Modules High Speed Keyphasor Signal Conditioning

Dynamic Input Module Types Speed/ Frequency Input range of 1 to 120,000


Signal Ranges cpm (0.017 to 2 kHz).
PAV (-) (Prox, Accel, Velom)  

PAS (-) (Prox, Accel, Seismic) High Speed Keyphasor Outputs

PAA (-) (Prox, Accel, Aero) Analog Short circuit protected


Buffered output signal available
PAD (-) (Prox, Accel, DC LVDT) through BTO connector on
Transducer
Output public and utility side.
PVT (+) (Prox, Accel, Velom)
 
This is a true analog signal from the
Dynamic Input Module Inputs input, not digital to analog
reconstitution of the input signal.
Power 14.2 Watts max
 
Analog See Dynamic Input Module
Input Sensors and Measurements on AC LVDT
page 14.
AC LVDT Inputs
Channels 4 Dynamic Inputs
Supported
Signal Accepts 1 to 4 signal inputs
  from AC LVDT
Dynamic Input Module Outputs Power 8.5 Watts typical, 12 Watts
Consumption max
Analog Short circuit protected output
Buffered signal available through BTO  

connector on public and


Transducer
Output utility side. Isolated Process Variable /
Discrete Input (PVD)
This is a true analog signal from the
input, not digital to analog PVD Electrical
reconstitution of the input signal.
Power 1.5 watts typical, 5 watts
  Consumption maximum

Channels 6
High Speed Keyphasor
Isolation 700 V Channel to System and
High Speed Keyphasor Inputs Channel to Channel isolation
 
Power 14.2 Watts max
PVD Input
Analog See Dynamic Input Module
Input Sensors and Measurements on 4 to 20 mA 0 to 25mA DC
page 14.
-10 Vdc to +10 Vdc -10Vdc to +10Vdc +-1%
Channels 4 Dynamic Inputs
 
Discrete Input with Polarity Independent
Two-Terminal Dry A/B Terminals for dry
Contact contacts

23/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H
   
Isolated Thermocouple (ITC) Relay Specifications
ITC Electrical
Power 1.5 watts typical, 5 watts
Consumption maximum
Isolation 700 V Channel to System and
Channel to Channel isolation  

Power 1.5 watts typical, 5 watts Electromechanical Relay (EMR)


Consumption maximum
Type Electromechanical
Single-Pole, Double-
ITC Inputs Throw
Thermocouple Type J, K, E, T Number of Relay 8
Sensor Outputs
 
Environmental Epoxy Sealed
RTD/TC Temperature (RTC) Operation Each relay is
configurable for
TC Temperature Normally De-Energized
or Normally Energized
Thermocouple Type J, K, E, T
Contact Rating for Standard Systems
Channel 6
Supported Minimum Switched 100 mA
Current
RTD Temperature
DC Maximum 4.5 A @ 30 VDC
RTD Type Pt100 (385), Pt100 (392), Ni120, Switched Current
Cu10
DC Maximum 125 Vdc
  Switched Voltage

Recorder Output Module AC Maximum 250 Vrms


Switched Voltage

Recorder Inputs AC Maximum 4.5 A


Switched Current
Input Signal Accepts 1 to 6 processed
signals from available input Maximum Switched 180 W or 1800 VA
modules over the Power
communication bus
Contact Rating for Hazardous Area Systems
Power 1.5 watts typical, 5 watts
Maximum Switched 4.5 A
Consumption maximum
Current

Recorder Outputs DC Maximum 30 Vdc


Switched Voltage
Output Types 4 to 20 mA range across load
AC Maximum 160 Vrms
1 to 5 V range across load Switched Voltage
0 to 10 V range across load
 

24/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

Solid State Relays (SSR) Touchscreen Resistive

Type Solid State


Single-Pole, Power 10 to 28 VDC
Double-
Throw Operating 0 to 60°C
temperature
Number of Relay Outputs 8 range

Environmental Plastic IP Rating IP54 (Front Bezel only)


Encapsulated
Certification  n ATEX Zone 2, C1D2,
Operation Each relay is IECEx Zone 2
configurable
for Normally 15” C1D2 Hazardous Area Display
De-Energized
or Normally Interfaces  n VGA and DVI-D display
Energized outputs
 n USB 2.0 port
Contact Rating for Standard Systems
 n DB9 Serial port
Minimum Switched Current 1 mA  n 24 VDC Power input port

DC Maximum Switched 125 mA @ 125 Diagonal 15"


Current Vdc Size
DC Maximum Switched 125 Vdc Resolution 1024 x 768
Voltage
Aspect Ratio 4:3
Maximum Switched Power 650 mW
Brightness 350 nits (cd/m2)
Contact Rating for Hazardous Area Systems
Touchscreen Resistive
Maximum Switched Current 125 mA

DC Maximum Switched 50 Vdc Power 12 to 28 VDC


Voltage
Operating -20 to 60°C
Display Specifications temperature
range
10.4” C1D2 Hazardous Area Display IP Rating Designed to meet IP66
(Front bezel only)
Interfaces  n VGA display output
 n DB9 Serial port Certification UL C1D2 (North America Only
 n 24 VDC Power input port Hazardous Locations)

Diagonal 10.4" 21.5” Industrial Area Display


Size
Interfaces  n VGA and DVI-D display
Resolution 640 x 480 outputs
 n USB 2.0 port
Aspect Ratio 4:3
 n DB9 Serial port
Brightness 400 nits (cd/m2)
Diagonal 21.5"

25/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

Size

Resolution 1920 x 1080

Aspect Ratio 16:9

Brightness 300 nits (cd/m2)

Touchscreen Projected Capacitive

Power 12 to 28 VDC

Operating 0 to 55°C
temperature
range

IP Rating IP66 (Front bezel only)

Certification Not certified for hazardous


locations.

Bently Nevada Industrial Computer

Interfaces  n VGA display output


 n DisplayPort display output
 n Gigabit Ethernet network
port
 n USB 2.0 ports
 n DB9 Serial port

Cabinet Brushed stainless steel

OS 64bit

Size 5.2 x 4.8 x 3.4 in. (132 x 122 x 87


mm)

Power 12 to 36 VDC

Mounting DIN-rail mountable

Operating -40 to 70°C


temperature
range

Certification UL C1D2 (North America Only


Hazardous Locations) ATEX
Zone 2, IECEx Zone 2, DNV-GL,
IEC 60945

26/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H
 
 
 

Compliance and Maritime


Certifications (Approvals DNV GL rules for classification – ships,
Pending) offshore units, and high speed and light
craft
FCC ABS Rules for Condition of Classification,
Part 1
This device complies with part 15 of the
FCC Rules. Operation is subject to the  l Steel Vessels Rules
following two conditions:  l Offshore Units and Structures
 l This device may not cause harmful
Functional Safety
interference.
 l This device must accept any SIL 2
interference received, including
 
interference that may cause
undesired operation. Hazardous Area Approvals
EMC (Approvals Pending)
European Community Directive: For the detailed listing of country and
product specific approvals, refer to the
EMC Directive 2014/30/EU
Approvals Quick Reference Guide
Standards: (108M1756) available from Bently.com.

EN 61000-6-2; Immunity for


Industrial Environments
CSA/NRTL/C
EN 61000-6-4; Emissions for Class I, Zone 2: AEx/Ex ec nC ic IIC T4
Industrial Environments Gc;
Electrical Safety Class I, Division 2, Groups A, B, C,
and D;
European Community Directive:  
T4 @ Ta= -30˚C to +70˚C (-22˚F to
LV Directive 2014/35/EU
+158˚F)
Standards:
ATEX/IECEx
EN 61010-1

RoHS II 3 G
Ex ec nC ic IIC T4 Gc
European Community Directive:  
T4 @ Ta = -30˚C to +70˚C (-22˚F to
RoHS Directive 2011/65/EU +158˚F)

Cyber Security
Designed to meet IEC 62443
 

27/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

Chassis: 10 Slot Bulkhead

Ordering Information 60R/CHA08 with options for:


• Country-specific codes
• SIL level
For the detailed listing of country and
product specific approvals, refer to the System Modules
Approvals Quick Reference Guide
(108M1756) available from Bently.com. System Interface Module

Chassis 60R/SIM01 with options for:


• Country-specific codes
Chassis: 3U Chassis • SIL level

60R/CHA01 with options for: Protection Processing Module


• Country-specific codes 60R/PPM01 with options for:
• SIL level • Country-specific codes
Chassis: 3U Panel • SIL level

60R/CHA02 with options for: Condition Monitoring Module


• Country-specific codes 60R/CMM01 with options for:
• SIL level • Country-specific codes
Chassis: 3U Bulkhead Power Input Modules
60R/CHA03 with options for: 60R/PIM01 3U Power Input Module
• Country-specific codes
• SIL level with options for:
• Country-specific codes
Chassis: 6U Chassis • SIL level

60R/CHA04 with options for: 60R/PIM02 6U Power Input Module


• Country-specific codes
• SIL level with options for:
• Country-specific codes
Chassis: 6U Panel • SIL level

60R/CHA05 with options for:


• Country-specific codes
• SIL level

Chassis: 6U Bulkhead

60R/CHA06 with options for:


• Country-specific codes
• SIL level

Chassis: 10 Slot Panel

60R/CHA07 with options for:


• Country-specific codes
• SIL level

28/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

Communications Input: (KPH) Keyphasor Module

Bridge Module 60R/INP06 with options for:


• Country-specific codes
60R/BRG01 with options for: • SIL level
• Country-specific
codes Input: RTD / TC Module
• SIL level
60R/INP07 with options for:
Communications Gateway • Country-specific codes
• SIL level
60R/CGW01 RJ-45 with options for:
Ethernet • Country-specific Input: (ITC) Isolated TC Module
codes
• SIL level 60R/INP08 with options for:
• Country-specific codes
60R/CGW02 RS-485 with options for: • SIL level
Serial • Country-specific
codes Input: (PVD) Isolated PV / DI Module
• SIL level 60R/INP09 with options for:
  • Country-specific codes
• SIL level
Input Modules
Input: AC LVDT Module
Input: (PAV) Prox/Accel/Velom Module
60R/INP10 with options for:
60R/INP01 with options for: • Country-specific codes
• Country-specific codes • SIL level
• SIL level
Output Modules
Input: (PAA) Prox/Accel/Aero Module

60R/INP02 with options for: Recorder_Output Module


• Country-specific codes
60R/REC01 with options for:
• SIL level
• Country-specific codes
Input: (PAS) Prox/Accel/Seismic Module • SIL level

60R/INP03 with options for: Relay: (EMR) Electro-Mech Relay Module


• Country-specific codes
60R/RLY01 with options for:
• SIL level
• Country-specific codes
Input: (PAD) Prox/Accel/DCLVDT • SIL level

60R/INP04 with options for: Relay: (SSR) Solid State Relay Module
• Country-specific codes
60R/RLY02 with options for:
• SIL level
• Country-specific codes
Input: (PVT) Pos Voltage Xdcr Module • SIL level

60R/INP05 with options for:


• Country-specific codes
• SIL level

29/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

Power Supply Bently Nevada Industrial Computer

AC: 110/240V (240W) for 3U chassis 60X/CMP-AAA

60X/XPS01 with options for: AAA Hazardous Area Certifications


• Country-specific codes
• SIL level Includes DIN Mounting Kit, 24 VDC 90-Watt DIN
Mountable Power Supply, USB Mouse, 24 VDC
AC: 110/240V (480W) for 6U chassis Power Cable, 10' (3m) Ethernet Cable. A 20’
Ethernet cable accessory is available.
60X/XPS02 with options for:
• Country-specific codes Front Panel Configurations
• SIL level

DC: High Voltage (240W) for 3U chassis 3U Front Panel: SIM w/ No Display

60X/XPS03 with options for: 60R/PNL01 with options for:


• Country-specific codes • Country-specific codes
• SIL level • SIL level

DC: High Voltage (480W) for 6U chassis 3U Front Panel: No SIM & No Display

60X/XPS04 with options for: 60R/PNL03 with options for:


• Country-specific codes • Country-specific codes
• SIL level • SIL level

10 Slot: w/ SIM
External Display
60R/PNL05 with options for:
60X/EXDAA-BBB-CC
• Country-specific codes
• SIL level
AA
10 Slot: no SIM
01 10.4" Hazardous Area Display
60R/PNL06 with options for:
02 15" Hazardous Display • Country-specific codes
• SIL level
03 21.5" Industrial Display

BBB – Hazardous Area Certifications

2- 3 digits See Approvals Quick Reference


Guide (108M1756) for more
information.

CC

01 19" Rack Mount Panel

02 Panel Mount Kit

04 Independent Mount

* Displays include 10' power cable.

30/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

Dongles and Cables 166112 RTD Isolator

60X/BTC01 4-Channel Buffered Output Configuration Software


Adapter

60X/BCK Bridge Field Cable Kit with 60X/CFG Orbit Studio Configuration
option for country codes Software

Bridge Interface Copper Cable - 2 feet Miscellaneous


60X/BIC01 with options for: 60X/WPH01 Weather Proof Housing: 3U with
• Country-specific codes country-specific approval
• SIL level options
Bridge Interface Copper Cable - 10 feet 60X/WPH02 Weather Proof Housing: 6U with
60X/BIC02 with options for: country-specific approval
• Country-specific codes options
• SIL level 60X/WPH03 Weather Proof Housing: 10 Slot
Bridge Interface Copper Cable - 50 feet with country-specific approval
options
60X/BIC03 with options for:
• Country-specific codes 60X/RCI01 Remote Interface: Push Button
• SIL level with country-specific approval
options
Bridge Interface Copper Cable - 100 feet
60X/RCI02 Remote Interface: Key Switch
60X/BIC04 with options for: with country-specific approval
• Country-specific codes options
• SIL level
60X/KEY01 System Key
Bridge Interface Copper Cable - 300 feet
60X/RCI01 Remote Interface: Push Button
60X/BIC05 with options for:
• Country-specific codes 60X/RCI01 Remote Interface: Key Switch
• SIL level 60R/BLK01 Blank: Module slot blank cover
External Barriers 60R/BLK02 Blank: Power slot cover

175502 3-pin Transducer Barrier

177241 2-pin Velomitor Barrier

175990 Thermocouple Barrier

175501 RTD Barrier

External Galvanic Isolators


397A8826 3-pin Transducer Isolator
397A8827

166111 Thermocouple Isolator

31/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

Display Accessories 174013 3m (9.8') USB     X


Cable
10.4” C1D2 Hazardous Area Display
149M1306 7m (25') USB     X
120M8155-01 Bently Nevada 10.4" Hazardous Cable
Area Display  

122M3369-01 Rack Mount kit for 10" Display Bently Nevada Industrial Computer
122M3370-01 Panel Mount kit for 10" Display 142M4200 Bently Nevada Industrial
122M3371-01 Independent Mount for 10" Computer
Display 02200794 24 VDC 90-Watt Power Supply
  (can power both the industrial
computer and display)
15” C1D2 Hazardous Area Display
119M6509-05 10' Power cable and plug
102M8950 15” Hazardous Area Display
149M1309 USB Mouse (only required for
104M3812-01 Rack Mount Kit for 15” Display first time configuration.)
 
149M1310 3m (10') Ethernet Patch Cable
21.5” Industrial Area Display
149M1311 7m (25') Ethernet Patch Cable
150M1466 21.5” Industrial Display

150M0633-01 19” Rack Mount Panel for 21.5”


Display
 

Display Cables 10.4" 15" 21.5"

02200794 24 VDC 90- X X X


Watt Power
Supply

119M6509-01 10' Power X    


cable and
plug

119M6509-02 10' Power   X X


cable and
plug

161087-10-00 10' VGA Cable X X X

161087-20-00 20' VGA Cable X X X

148638-01 10' Serial Cable X X  

148638-02 25' Serial X X  


Cable

32/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

   
Glossary of Terms    
RTD Resistance Temperature Detector
Accel Acceleration
SIL Safety Integrity Level
Aero Aeroderivative
SIM System Interface Module
API American Petroleum Institute
SSR Solid State Relay
BRG Bridge
SW Software
BTO Buffered Transducer Output
TC Thermocouple
CGW Communication Gateway Module
TC/RTD Thermocouple/Resistance Temp
CMM Condition Monitoring Module Detector
DCS Distributed Control Systems TCP/IP Transmission Control Protocol
EGD Ethernet Global Data protocol Internet Protocol
ESD Emergency Shutdown Device OEM Orginal Equipment Manufacturer
EIA Energy Information Administration Velom Velomitor
EMR Electro-Mechanical Relay
HAZLOC Hazardous Location
HTVAS High Temperature Velocity/Accel
Sensor
I/O Input/Output
IEPE Integrated Electronics Piezo-Electric
ITC Isolated Thermocouple
KPH High Speed Keyphasor
LVDT Linear Variable Differential
Transformer
NEMA National Electrical Manufacturers
Association
OEM Orginal Equipment Manufacturer
PAA Prox, Accel, Seismic
PAE Prox, Accel, Aero
PAS Prox, Accel, Seismic
PAV Prox, Accel, Velom
PIM Power Input Module
PLC Programmable Logic Controller
PPM Protection Processing Module
Prox Proximitor
PVD Isolated Process Variable, Discrete
Input
PVT Positive Voltage Transducer
REB Roller Element Bearing
REC Recorder Outputs
RMC Remote Monitoring Center

33/34
Orbit 60 Series System
Datasheet 137M5182 Rev. H

Copyright 2020 Baker Hughes Company. All rights reserved.

Bently Nevada, Orbit Logo, Keyphasor, Velomitor, Proximitor, and System 1 are registered trademarks of Bently Nevada,
a Baker Hughes Business, in the United States and other countries. The Baker Hughes logo is a trademark of Baker
Hughes Company. All other product and company names are trademarks of their respective holders. Use of the
trademarks does not imply any affiliation with or endorsement by the respective holders.
Baker Hughes provides this information on an “as is” basis for general information purposes. Baker Hughes does not
make any representation as to the accuracy or completeness of the information and makes no warranties of any
kind, specific, implied or oral, to the fullest extent permissible by law, including those of merchantability and fitness
for a particular purpose or use. Baker Hughes hereby disclaims any and all liability for any direct, indirect,
consequential or special damages, claims for lost profits, or third party claims arising from the use of the
information, whether a claim is asserted in contract, tort, or otherwise. Baker Hughes reserves the right to make
changes in specifications and features shown herein, or discontinue the product described at any time without
notice or obligation. Contact your Baker Hughes representative for the most current information.
The information contained in this document is the property of Baker Hughes and its affiliates; and is subject to
change without prior notice. It is being supplied as a service to our customers and may not be altered or its content
repackaged without the express written consent of Baker Hughes. This product or associated products may be
covered by one or more patents. See Bently.com/legal.

1631 Bently Parkway South, Minden, Nevada USA 89423