2 SECTION A-A
600
35
700
SQUARE OR CIRCULAR FORMWORK TO BE
ELEVATION VIEW USED AT TOP OF FOOTING. CONCRETE TO
SLOPE 25mm AWAY FROM POST
FORMWORK AS DIRECTED BY CLIENT
18 HOLES FOR:
4/M16x110 CAST IN-SITU NOTES:
GAL BOLTS OR
4/CHEMSET FASTENERS 1. CUSTOMER TO NOMINATE PREFFERED FOOTING / FIXING (IN GROUND, PLATFORM & SIDE MOUNT).
110 2. CUSTOMER TO NOMINATE PREFFERED RAIL SIZE - 32NB STANDARD SYSTEM OR 40NB HEAVY
SYSTEM.
B DETAIL 1 3. PROTECTION TREATMENT AND PAINT SYSTEMS TO BE IN ACCORDANCE WITH CLIENT B
REQUIREMENTS.
4. ALL POSTS TO BE 40NB (48.3 OD, 3.2 THICK) GALVANISED STEEL TUBE.
5. ALL HORIZONTAL RAILS TO BE ROLLED TO MATCH SHAPE OF PATH IF RADIUS IS LESS THAN 14m.
110
110
66
66
6. BARRIER DESIGNED TO MEET RECOMMENDATIONS FOR SHARED PATH BARRIER AS OUTLINED IN
40 MAX
AUSTROADS GUIDE TO ROAD DESIGN PART 6A - PATHS FOR WALKING AND CYCLING.
PACK VOID 7. STANDARD MONOWILLS LINK VELOCITY FULL BARRIER DESIGNED TO MEET BARRIER TYPE C3
WITH GROUT AS/NZS 1170.1:2002 (R2016)
8. ALL WELDS TO BE 4MM C.F.W. (CONTINUOUS FILLET WELDS) TO AS/NZS 1554.1.
LEVELING NUT 102 18 HOLES FOR: 9. PREFERRED COLD GALVANISING TREATMENT FOR IN-SITU WELDS, CUT ENDS OR OTHER BARE
66 STEEL TO BE IN ACCORDANCE WITH AS/NZS 4680:2006 CLAUSE 8 REPAIR PROCEDURE.
4/M16x110 CAST IN-SITU 10. ALL CONCRETE TO BE GRADE N25 OR AS CLIENT SPECIFIED.
146 GAL BOLTS OR 11. POSTS INSTALLED IN EXISTING BRIDGE/CULVERT CONCRETE TO BE GROUTED INTO 90mm HOLE
4/CHEMSET FASTENERS WITH 1:3 CEMENT MORTAR BY VOLUME AFTER THEY HAVE BEEN CAREFULLY ALIGNED.
12. THESE FENCES ARE INTENDED AS A PEDESTRIAN BARRIER AND ARE NOT TO BE USED IN
DETAIL 3 SITUATIONS WHERE MOTOR VEHICLES REQUIRE RESTRAINT.