Septic Tank
Septic Tank
Septic Tank
C1 B1 C1 B1 C1 B1 C1
9' B1 B2 B2
B1
C1
C1 C1 18'
B2 B2
C1
B1 B2 B2
9' B2
B1
C1 B1 C1 B1 C1 B1 C1
7'-6" 7'-6" 10'
BEAM & COLUMN PLAN
A A
S1
A A
S1 S1
S1
A A
2'-6"
REINFORCEMENT
TYPE THICKNESS LAYER X - DIRECTION Y - DIRECTION REMARK
CONT: EDGE MID SPAN DISCONT: EDGE CONT: EDGE MID SPAN DISCONT: EDGE
TOP 12mmØ @ 6"c/c 12mmØ @ 6"c/c 12mmØ @ 6"c/c 12mmØ @ 6"c/c 12mmØ @ 6"c/c 12mmØ @ 6"c/c
S1 8" TWO WAY
BOTTOM 12mmØ @ 6"c/c 12mmØ @ 6"c/c 12mmØ @ 6"c/c 12mmØ @ 6"c/c 12mmØ @ 6"c/c 12mmØ @ 6"c/c
SW1 10" 12mm @ 4" c/c 12mm @ 6" c/c 12mm @ 18" c/c (V) & 12mm @ 12" c/c(H) 1.5" 0.75"
COLUMN SCHEDULE
SIZE LONGITUDINAL MAIN TIE ARRANGEMENT DETAILS
TYPE
L B REINFORCEMENT HOOP/SET OF TIE TIE ARRANGEMENT
BEAM SCHEDULE
MAIN REINFORCEMENT
TYPE SIZE LEFT END SUPPORT MID SPAN RIGHT END SUPPORT STIRRUP REMARK
B1 10" x 12" 3 - 16mmØ 3- 16mmØ 3 - 16mmØ 3 - 16mmØ 3 - 16mmØ 3 - 16mmØ 8mmØ @ 4"~6" c/c
B2 9" x 9" 3 - 16mmØ 3- 16mmØ 3 - 16mmØ 3 - 16mmØ 3 - 16mmØ 3 - 16mmØ 8mmØ @ 4"~6" c/c