The Janus Fire Systems® Sv Series Clean Agent Fire Suppression System for Marine Application uti-
lizes FM-200® as the extinguishing medium. FM-200® is a colorless, non-toxic gas perfectly suited
to protect high value assets in areas that may be normally occupied, in locations where clean-up of
other agents is problematic, when storage space for a fire suppression agent is restricted, or when
an electrically non-conductive agent is required. Each system consists of the following components
and their associated accessories:
1. Agent Storage Components - These components consist of the cylinder assembly(s), which
contains the FM-200® agent, and the agent cylinder bracket(s), which holds the cylinder assembly
securely in place. These components are utilized in both arrangements.
2. Nitrogen Driver Components - These components consist of the large nitrogen driver cylinder
assembly and the nitrogen cylinder bracket(s), which holds the cylinder assembly securely in place.
These components are utilized in both arrangements.
3. Agent Distribution Components - These components consist of the discharge nozzles used to
atomize the liquid FM-200® and introduce it into a protected hazard along with the associated
piping system used to connect the nozzles to the cylinder assembly. These components are utilized
in both arrangements.
4. Trim Components - These components complete the installation of the agent cylinder and nitrogen
driver cylinder and consist of connection fittings, pressure gauge, and optional supervisory low-
pressure switch. These components are utilized in both arrangements, but the specific components
used will vary slightly according to the series valve installed.
5. Slave Arrangement Components - These components consist of the pneumatic valve actuator(s),
pilot actuation check valve, vent check, actuation hoses, and fittings required for a multiple cylinder
(slave) arrangement. These components are utilized in both arrangements where multiple cylinders
are installed on a single discharge manifold.
6. Supplemental Components - These components
include the discharge pressure switch and may
be utilized in a variety of locations within an
arrangement or for multiple purposes.
These components are utilized in both
arrangements as necessary.
7. Cable Pull Equipment - Cable-pull
equipment is installed to allow the
remote manual actuation of the system
cylinders. The equipment includes
the remote pull station, cable, pulley
elbows, and cable-actuated stop
valve. These components are utilized
in the Cable Pull arrangements.
8. Remote Nitrogen Actuation
Equipment - Nitrogen actuation
equipment is installed to allow the
remote pneumatic actuation of the system
cylinders. The equipment includes the
remote actuation cylinder and pneumatic
stop valve. These components are utilized in the
Pneumatic Actuation arrangements.
9. Control Panel - This device may be used to monitor
auxiliary devices (low-pressure supervisory switch, discharge
pressure switch, etc.) as well as any fire detector, warning devices, or alarm/notification devices
10. Early Warning and Alarm Devices - Early warning devices maximize system efficiency while
audible and visual alarm devices alert staff of alarm conditions.
DS1353 Revised: 24-May-2019 © 2018 Janus Fire Systems. All rights reserved (8/2018) Janus Design Suite® and Janus Fire Systems® are registered trademarks of Janus Fire Systems.
FM-200 is a trademark of Chemours.
EQUIPMENT DESCRIPTION
The FM-200® agent is stored as a liquid in cylinder assemblies designed specifically for the ap-
plication and charged to a fill density of between 35 lb/ft3 (561 kg/m3) and 70 lb/ft3 (1121 kg/m3). To
ensure optimal performance, each cylinder is superpressurized with dry nitrogen to 360 psi (24.8
bar) at 70°F (21°C). An identification label is affixed to the cylinder body indicating the fill quantity
of FM-200®, charging pressure, date of fill, and fill station. The Sv Series supports three cylinder
capacities.
FM-200® fire extinguishing systems are designed to be discharged within 10 seconds into a room,
area, or enclosure with the structural integrity to retain the agent. The FM-200® uniformly mixes
throughout the protected area, achieving a minimum concentration level in accordance with NFPA
2001 and/or agency listings.
The cylinder assembly is composed of a cylinder, dip tube, and cylinder valve.
Cylinder Bracket
Cylinder: The light walled, welded seam cylinder is
manufactured according to the requirements of the
U.S. Department of Transportation (USDOT) and
Transport Canada (TC) for compressed gas. Internal
neck threads allow connection of the cylinder valve.
The cylinder is designed for mounting in a vertical po-
sition only.
Cylinder
CYLINDER MOUNTING
Cylinder Dimensions
H2
40 lb 80 lb 130 lb
D2 in mm in mm in mm
H1 23.83 605 36.56 929 53.0 1346
H3
H2 19.93 506 32.67 830 49.10 1247
H3 13.0 330 16.0 406 32.0 813
H4 3.0 76 6.0 152 12.0 305
H4 D1 10.0 254 10.0 254 10.0 254
D2 11.9 302 11.9 302 11.9 302
D1
OPTIONAL SECONDARY
SIREN LINE
Nitrogen
Actuation Stop Valve
Bottle Bypass
Pneumatic
Time Delay
Nitrogen
Driver Cylinder
Pneumatic
Remote Siren
Manual Pull
Stations
Stop Valve
OPTIONAL SECONDARY
SIREN LINE
Stop Valve
Bypass
Pneumatic
Time Delay
Nitrogen
Driver Cylinder
Manual-Pneumatic
Valve Actuator
(P/N 98533)
Male NPT x JIC 16" Flex Hose
Adapter (P/N 18648)
(P/N 18625) Male NPT x
Flared Elbow
NPT Style Check Valve (P/N 99353)
(P/N 10262)
1/4” (8 mm)
FNPT Pneumatic Stop Valve (P/N 99766)
Actuation Inlet
A three-way pilot valve acts as the pneumatic stop valve for
the Pneumatic Actuation arrangement. It has a standalone
ambient temperature range of -40° to 300°F (-40° to 149°C)
and is rated for an operating pressure of 3000 psi (207 bar).
The valve body is aluminum with a stainless steel piston.
1/4” (8 mm)
FNPT 1/4” (8 mm)
Outlet FNPT Supply Inlet
Nominal
Height (H) Width (W) Cylinder
Cylinder Size1 P/N
Bracket P/N
L in³ in mm in mm
39.1 2,386 26093 55.6 1412 8.5 216 97768
50.0 3,051 26094 61.1 1552 9.2 234 97767
66.7 4,070 26095 62.6 1590 10.4 264 97766
Pneumatic
Pre-Discharge Timer
(Factory set to 30
1/4” (8 mm)
seconds)
Timer Bypass
Valve
Pneumatic
Pilot Valve
Breather
Conduit Hub EXHAUST OUTLET
1/2” (15 mm) FNPT 1/4” (8 mm) FNPT
Various adapter fittings are required to accommodate the attachment of the pilot actuation check
valves, tees, flex hose, and actuators. The list below includes part numbers and descriptions for all
the commonly supplied fittings. All fittings are brass.
1/4” (8 mm)
FNPT Pipe
Connection
Warning Signs
Warning signs are place all entrances to and inside the
protected area. Optional Spanish or combination Arabic/
English versions of each sign are available.
Discharge Nozzle
Cut View
Note: The spacing limitations for Janus Fire Systems nozzles shown above are those for a marine environment.
The limitations are different when used in a standard industrial environment.
Most common metals, such as aluminum, brass, steel, cast iron, lead, stainless steel, and copper,
as well as rubber, plastic, and electronic components, are unaffected when exposed to FM-200®.
SAFETY CONSIDERATIONS
Although the EPA Significant New Alternative Program (SNAP) lists FM-200® as acceptable for oc-
cupied spaces, NFPA Standard 2001 and SNAP list the following guidelines for human exposure:
The discharge of FM-200® into a hazard may Time for Safe Human
reduce visibility for a brief period. FM-200® Exposure at Stated Concentrations
may cause frostbite if liquid discharge or es- for FM-200® (HFC-221ea)
caping vapor contacts the skin. FM-200® Maximum Human
Concentration Exposure Time
When FM-200® is exposed to temperatures % v/v ppm (Minutes)
greater than 1300°F (700°C), the by-product
9.0 90,000 5.00
Hydrogen Fluoride (HF) will be formed. FM-
200® systems are designed to discharge in 9.5 95,000 5.00
10 seconds or less in order to minimize the 10.0 100,000 5.00
amount of HF formed. 10.5 105,000 5.00
The FM-200® Material Safety Data Sheet 11.0 110,000 1.13
(MSDS) should be read and understood prior to 11.5 115,000 0.60
working with the agent. 12.0 120,000 0.49
Notes:
A cylinder containing FM-200® should be han-
1. Data derived from the EPA-approved
dled carefully. The anti-recoil safety device
and peer-reviewed PBPK model or its
must be in place at all times when the cylin-
equivalent.
der is not connected to the discharge pip-
2. Based on LOAEL of 10.5% in dogs.
ing and restrained.
The seller makes no warranties, express or implied, including, but not limited to, the implied warranties of merchantability and
fitness for a particular purpose, except as expressly stated in the seller’s sales contract or sales acknowledgment form. Every
attempt is made to keep our product information up-to-date and accurate. All specific applications cannot be covered, nor can
all requirements be anticipated. All specifications are subject to change without notice.