NATIONAL IRANIAN SOUTH OIL COMPANY

 
N.I.S.O.C

PROJECT: GACHSARAN Reservoirs Basic Studies Project


Project No.: …………………….
Contract No.: ……………………

GATHERING OF WASTE VAPORS FROM ETHYLENE


GLYCOL REGENERATION SYSTEM GACHSARAN LOW
PRESSURE GAS COMPRESSION STATION NO.1

Data sheet For Vent Gas K.O.Drum (GS-1)

B0 ISSUE FOR COMMENT M.R.Amiri S.Gholami Gh.Rahmati 1399/07/28

Prepared by Check by Approved by Date Approved Date


REV. DESCRIPTION
CONSULTING

DOCUMENT NO.: 151-G1-GS-GLY-PR-DOC-0003

TRANSMITTAL NO.: TR-TACE-NISOC-151-PR-069

REV.: B0 PAGE: 1 of 3
Project No.:

Document No: 151-G1-GS-GLY-PR-DOC-0003

 N.I.S.O.C Date: 99/07/28


PROJECT :GATHERING OF WASTE VAPORS FROM ETHYLENE Rev.: B0
GLYCOL REGENERATION SYSTEM
(GACHSARAN LOW PRESSURE GAS COMPRESSION STATION NO.1) Page: 2 of 3

Document Title: Data sheet For Vent Gas K.O.Drum (GS-1)


TABULATION OF REVISED PAGES
REVISION REVISION
SHEET REMARK SHEET REMARK
B0 B1 B2 B3 B0 B1 B2 B3
1 × 51
2 × 52
3 × 53
4 54
5 55
6 56
7 57
8 58
9 59
10 60
11 61
12 62
13 63
14 64
15 65
16 66
17 67
18 68
19 69
20 70
21 71
22 72
23 73
24 74
25 75
26 76
27 77
28 78
29 79
30 80
31 81
32 82
33 83
34 84
35 85
36 86
37 87
38 88
39 89
40 90
41 91
42 92
43 93
44 94
45 95
46 96
47 97
48 98
49 99
50 100
Project No.:
Document No: 151-G1-GS-GLY-PR-DOC-0003
 N.I.S.O.C Date: 99/07/28
PROJECT :GATHERING OF WASTE VAPORS FROM ETHYLENE Rev.: B0
GLYCOL REGENERATION SYSTEM
(GACHSARAN LOW PRESSURE GAS COMPRESSION STATION NO.1) Page: 3 of 3
1 ITEM No.: V-1001 QTY: 1 SERVICE Vent Gas K.O. Drum (GS-1)
2 OPERATING PRESSURE: 1 bara @ 60 ºC MAWP: NOTE 1 Barg
3 DESIGN PRESSURE: 3.5/F.V Barg @ -5/200 ºC HYDROTEST PRESSURE: 4.55 Barg
4 ORIENTATION: Vertical JOINT EFFICIENCY: NOTE 1
5 DESIGN CODE: IPS- G-ME-150/ASME SECTION VIII RADIOGRAPHY SHELL / HEAD SPOT / FULL
6 OTHER SPECIFICATION: SEISMIC CODE : UBC 97 SEISMIC ZONE : 3 IMPORTANCE FACTOR 1.25
7 WEIGHTS kg FAB: EMPTY OP. TEST WIND CODE UBC 97 WIND VELOCITY 130 Km/ hr
8 FLOW RATE: 23.72 vap. / 0.47 liq. M3/Hr POSTWELD HEAT TREATMENT: AS PER ASME CODE
9 S.G 1.105 (gas phase) - 0.980 (liq phase) VESSEL PAINTING/COATING DETAILS: AS PER: IPS- G-ME-150
10 VESSEL HEAD TYPE: 2:1 Elliptical INSULATION: NO
11 TYPE OF SERVICE: INSPECTION REQUIREMENTS: AS PER ASME CODE
12 CORROSION ALLOWANCE (mm): SHELL 3.2 HEAD 3.2 INTERNALS 3.2
13 DIMENTION (ID/TL.TL)(mm) 500 x 3000 PID: 151-G1-GS-GLY-PR-DWG-0003-B01 NOZZLES
14 MATERIALS ITEM No. SIZE RATING TYPE SERVICE
15 HEAD SA-516 70 N1 1 4" 150# W.N. - R.F. GAS INLET
16 SHELL SA-516 70 N2 1 4" 150# W.N. - R.F. GAS OUTLET
17 INTERNALS (WELDED/ REMOVABLE) SAME AS SHELL/ S.S N3 1 2" 150# W.N. - R.F. VENT
18 WEAR PLATE/SADDLES SA-516 70/SA-283 Gr.C N4 1 2" 150# W.N. - R.F. LIQUID OUTLET
19 BASE SA-283 Gr. C N5 1 2" 150# W.N. - R.F. UTILITY CONNECTION
20 NOZZLE NECK SA-106 Gr. B L1/L2 2 2" 300# W.N. - R.F. LEVEL SWITCH LL
21 FLANGES SA-105 L3/L4 1 2" 300# W.N. - R.F. LEVEL GAGE
22 GASKETS (NOTE 2) L5/L6 2 2" 300# W.N. - R.F. LEVEL SWITCH HH
23 Bolts/Nuts SA-193-GR B7 / SA-194- GR 2H HH 1 6" 150# W.N. - R.F. HAND HOLE
24 CLIPS & ATTACHMENTS SA-283 Gr. C
25 MISCELLANEOUS
26 INSULATION NO
27 LADDER & PLATFORM (Int.& Ext.) YES
28 DAVIT FOR MANHOLE YES
29 INSULATION SUPPORT NO
30 SPECIAL INTERNALS NO
31 EARTHING YES
32 NAME PLATE YES
33 VORTEX BREAKER YES
34 BOOT NO
35 LIFTING LUG YES
36 DEMISTER PAD NO
37 BAFFLE YES
38 SKETCH

39

40

41

42

43

44

45

46

47

48

49

50

51 NOTES:
52 1- To be specified by Vendor.
53 2- Graphite asbestos free.
54 3- Stand
4- Nozzlepipe
orientation
shall beshall be specified
consider for levelingauges.
detail design stage by the Contractor.
55