COMPACT
HEAT EXCHANGER LHE
Spiral heat exchanger Oblong plate & shell Plate Coil CHU
heat exchanger

Plate and Frame heat exchanger


Spiral heat exchanger
Oblong plate & shell heat exchanger
Plate coil / Gas cooler
Pressure Vessel (Mist & Dust collector, etc.)
CHU(Compact heat exchanger unit)
PHE gaskets
Contents
01 Greeting Message
02 History
03 Production facilities
04 Plate and Frame heat exchanger
10 Spiral heat exchanger
14 Oblong plate & shell heat exchanger
16 Plate coil heat exchanger
18 CHU(Compact heat exchanger unit)
20 Gas heat exchanger
22 Pressure Vessel (Mist & Dust collector, etc.)
23 COMPABOX heat exchanger
24 DOUBLE WAVE heat exchanger
25 Super High Efficiency Plate heat exchanger

LHE
Leader of 26 PHE gaskets
Heat
30 Quality Management System
Exchanger !
32 Reference Data
Owing to supports from a lot of people, who has trusted us,
LHE could make our position firm in this industry and
always tried to share the fruits with all of you.
Now we are pleased to inform you that our company name
has been changed from DHT to LHE (Leader Heat
Exchanger) and we will jump to the center of the world
industry with the new name.

World Best!!
Leader Heat Exchanger | www.lhe.co.kr

Greeting Message

LHE

Since foundation of LHE, we have made tangible effort, such as Business-University Joint Research to overcome
restrictions in using the existing plate heat exchangers, such as use at high temperatures and pressures, and to
develop more efficient heat exchangers based on the accumulated technologies. As a result of these ceaseless and
various efforts, we could secure the 25,000ton and 50,000 ton hydraulic presses, a world top class production
facility, by our own technology. Not satisfied with current achievements, however, we still push ourselves everyday
to develop more advanced technologies to repay for the customer’s supports.
On the way from a small venture business, which won an hard-to-get order (Crystallizer Reactor and Heating &
Cooling Device) without an appropriate production facility but only with our pure technology and customers' trust, to
a company of the current scale, which can design and develop the world class hydraulic press by its own technology,
we have made ceaseless efforts with so many trials-and-errors. With those efforts and experiences, we will
challenge the world top position in the industry. We are confident of our top class technologies and will bend our
efforts to prove it.
Based on customers’ trust, all of our employees and managerial staff will not forget our original spirit and provide the
industry’s leading technology and the best quality in return for the customer’s support. We'd like to thank all of the people
who have trusted and supported us from the beginning, and ask for your continuous support and encouragement.

Greeting Message
COMPACT HEAT EXCHANGER

History
Jul 2001 Founded DHT Co., Ltd.
Jul 2001 International Trading License registered.
Sep 2001 Designated as a Venture Business.
Jan 2002 Obtained "U" stamp from ASME (No.33038).
Jan 2002 Selected as a Promising Small & Medium Sized Enterprise
(Technology Evaluation by Korea Institute of Industrial Technology).
Mar 2002 Completed installation of 10,000 ton hydraulic press
(designed and manufactured by own technology).
Apr 2002 Approved of "Manufacturing License for Specific Facilities" for Pressure Vessel.
May 2002 Obtained approval for "DHT Technology Research Center".
Aug 2002 Obtained certificate of ISO 9001: Korea Gas Safety Corporation.
Jan 2003 Established Seoul Branch Office.
Mar 2003 Approved for "Certified Nuclear Power Quality Grade"
by Korea Hydro & Nuclear Power.
Aug 2003 Designated as an enterprise with excellent technology
by Korea Technology Credit Guarantee Fund.
Aug 2003 Acquired certificate of "Component & Material Technology Specialized Enterprise".
Sep 2003 Patent (#0399169) registered for "Double Wave Heat Plate and
Heat Exchanger with using Double Wave Heat Plate".
Jun 2004 Obtained the "CE MARK" by Lloyd’s Register.
Jun 2004 Obtained the Certificate of "ISO9001" by Lloyd’s Register.
May 2006 Changed company name to LHE Co., Ltd.
Sep 2006 Installed the World's biggest 50,000ton Hydraulic Press
(designed and manufactured by own technology).
Apr 2007 Accredited A+ by Korea Technology Credit Guarantee Fund.
Nov 2007 Awarded the $10 Million Export Tower by Korea International Trade Association.
Feb 2008 Installed 25,000 ton Hydraulic Press.
May 2008 Acquired New Factory in Incheon.
Jun 2008 Certificated "Quality Assurance for Marine and Power plant" by Mann Diesel.
Aug 2008 Obtained the Certificate of ”OHSAS18001” by Lloyd’s Register.
Aug 2008 Obtained the Certificate of “ISO1400” by Lloyd’s Register.

History
Leader Heat Exchanger | www.lhe.co.kr

Production Facilities

LHE's production facilities are equipped with modernized and optimized


system for manufacturing heat exchangers. The quality of heat plate is
directly related to the performance of Plate Heat Exchanger. We,
therefore, try our best to live up to customer's expectation by providing
with a various range of heat exchangers with large, medium, small and
mini-sized plates fabricated by 50,000, 25,000, 10,000ton hydraulic
presses.

50,000ton hydraulic press

10,000ton hydraulic press 25,000ton hydraulic press

Production Facilities
COMPACT HEAT EXCHANGER

Plate and Frame heat exchanger

Structure

Principle
and
Structure

The plate heat exchanger is fixed by numbers of thin and


corrugated heat plates, hanged between the carrying bar
Flowing diagram of fluid on the above and the guide bar on the below. These heat
plates provide flow channels for two kinds of fluid, and
the chevrons on the heat plates make the turbulent flow
Principle and play a role to support the plate against the pressure
difference between the two fluids. The plate pack is to be
placed between the fixed cover and the movable cover,
and fixed with tie bolts.

Movable Cover
Fixed Cover Roller Assembly Carrying Bar

A PLATE Gasket is attached to the heat plate which forms flow


channel and acts seal up the fluid not to leak to the
outside. The number of the heat plate is determined
according to the amount of fluid, physical properties of
fluid, the pressure drop and thermal condition. The covers
prevent the plates bended from the difference of
pressure. In the assembly of plate, the surface with
gasket is directed to the fixed cover and each plate is
hanged in opposite direction alternately. And two fluids
cannot be mixed and separated by a thin plate. One fluid
always flows in "A" channel and the other fluid always
Plate Pack Guide Bar
flow in "B" channel.
B PLATE

Plate heat exchanger


Leader Heat Exchanger | www.lhe.co.kr

Type of Heat Plate

HIGH -THETA PLATE


(High turbulent flow)
Type of (high heat transfer coefficient)
heat plate and (Perfect temperature approach)
Channel (High pressure drop)
LOW -THETA PLATE
(Low turbulent flow)
(Low heat transfer coefficient)
(High temperature approach)
(Low pressure drop) High-theta Plate Low-theta Plate High-theta Plate Low-theta Plate

Channel Combination

H (High Channel) : 2 High-theta


Combination of two high-theta heat plate)
There classes of channel with high theta plate L (Low Channel) : 2 Low-theta
and low theta plate are possible. Combination of two low-theta heat plate)
M (Medium Channel) High-theta Low-theta
Combination of one high-theta plate & one low-theta plate)

Plate : S.S 304, 304L, 316,


S.S 316L, Titanium, Ti-Pd,
Nickel, Hastelloy,
Avesta 254 SMO

Gasket : NBR, EPDM, FPM,


Neoprene, llR,
Butyle, Silicone

Plate heat exchanger


COMPACT HEAT EXCHANGER

Plate and Frame heat exchanger

Characteristics
and Characteristics
Usage
High efficiency

The heat plate forms corrugation to maximize the heat transfer efficiency and chevrons to create
turbulence flow also designed to make countercurrent flow which enables to diminish the quantity of
fluid remaining in the heat exchanger and eliminate the dead-zone. The plate heat exchanger can
obtain five(5) times heat transfer efficiency compared with shell and tube heat exchanger.

Dead Zone Wide contact area

The strength of the plate is excellent, compared with other companies' products with the point contact
type, as the metal contact point has the surface contact feature when the plates are assembled. And
the durability and corrosion resistance are greatly improved by minimizing deformation and stress
concentration.
Besides, the section of the gasket is designed and manufactured to have a pressure-resistant structure
that enables the minimum contact area with the fluid, and thus to withstand a high pressure.

LHE-Clip Gasket

The gasket can be fixed tightly and quickly on the heat plate in the optimum condition with the dual
fixing device (snap on type), and is designed and manufactured to have the glue type and non-glue type
so that it can be selected according to the usage.

Plate heat exchanger


Leader Heat Exchanger | www.lhe.co.kr

Even Fluid Distribution

Plate Inside flow Velocity:


V1 = V2 = V3 = V4

Minimized Dead zone Creation


Minimized Fouling
Increased Durability

Anti Vibration Design

Designed to prevent loosening the tightening bolts and nuts during continuing operation which secure
to prolong the equipment's operation lifetime and prevent leakages.

Insert Plate
Easy disassembly and assembly

Even the biggest model also can be assembled or disassembled by 1 or 2 persons.


As it is designed to have a dual fixing method of the insert-typed plate and insert-typed gasket, there is
Insert Gasket no sliding on the plates. It prevents sliding and an assembling failure even when a non-skilled novice
disassemble or assemble the device. (Excellent maintenance against materials with high viscosity such
as oils for LO cooler or oil heater)
FOULING FACTOR

r
ula
Tub
Temperature Approach
Plate Type

TIME

The turbulent flow, promoted by the wave pattern of the heat plates, enables a very high heat transfer
coefficient. Proximity Limit: 1

MAIN EN
GINE
GENERATO
R ENGINE
MAIN AIR
COMP
Application
COMP.
MAIN AIR
BE R
STURN TU F.W COOLE

R
L.O COOLE
R
JFW COOLE

Marine Application and Engines, Architecture


OLER
Industry, Automobiles Industry, Textile Industry, Pulp
S/T L.O CO

OLER
and Paper Industry, Chemical Industry, Steel
L F.W CO
CENTRA
Industry, Mechanical Industry, Food Industry, HVAC,
Power Stations, Surface Treatment

Plate heat exchanger


COMPACT HEAT EXCHANGER

Plate and Frame heat exchanger


Specifications

A
B

HT03 HT061 HT062 HT063 HT064 HT081 HT082 HT083 HT101 HT102 HT103 HT104 HT121 HT122 HT123 HT150 HT151 Height : 170cm HT156 HT152 HT153 HT154 HT200 HT201

HT206 HT202 HT203 HT204 HT231 HT232 HT233 HT234 HT235 HT301 HT302 HT303 HT304 HT305 HT311 HT316 HT312

HT313 HT314 HT351 HT356 HT352 HT353 HT354 HT451 HT452 HT453 HT454 HT501 HT502 HT503

Plate heat exchanger


Leader Heat Exchanger | www.lhe.co.kr

Plate and Frame Heat Exchanger Technical Data

Model HT02 HT03 HT061 HT062 HT063 HT064 HT081 HT082 HT083 HT101 HT102 HT103
Max. Flow m3/hr 5 17 68 68 68 68 116 116 116 170 170 170
Max.Conn.Dia. mm 25 40 80 80 80 80 100 100 100 150 150 150
Dimension - H mm 196 540 668 820 1105 1220 1133 1410 1825 909 1149 1489
Dimension - W mm 91 190 328 328 328 328 456 456 456 464 464 464
Dimension - C(min. ~ max.) mm 80~400 150~500 330 ~ 830 430 ~ 830 435 ~ 930 430 ~830 435 ~ 930 535 ~ 930 535 ~930 435 ~ 1535 435 ~ 1535 535 ~1535

Model HT104 HT121 HT122 HT123 HT151 HT156 HT152 HT153 H154 HT201 HT206 HT202
Max. Flow m /hr
3
170 210 210 210 360 360 360 360 360 640 640 640
Max.Conn.Dia. mm 150 150 150 150 200 200 200 200 200 200 200 200
Dimension - H mm 1629 1399 1805 2120 1663 1900 2137 2611 3085 1663 1900 2140
Dimension - W mm 464 615 615 615 720 720 720 720 720 720 720 720
Dimension - L(min. ~ max.) mm 535 ~ 1535 440 ~ 1640 440 ~ 1640 440 ~ 1640 450 ~ 1550 450 ~ 1550 450 ~ 1550 450 ~ 1550 450 ~ 1550 450 ~ 2850 450 ~ 2850 450 ~ 2850

Model HT203 HT204 HT231 HT232 HT233 HT234 HT235 HT301 HT302 HT303 HT304 HT305
Max. Flow m3/hr 640 640 790 790 790 790 790 1700 1700 1700 1700 1700
Max.Conn.Dia. mm 200 200 300 300 300 300 300 350 350 350 350 350
Dimension - H mm 2615 3090 1670 1985 2175 2550 3105 1963 2445 2685 2925 3405
Dimension - W mm 720 720 886 886 886 886 886 998 998 998 998 998
Dimension - L(min. ~ max.) mm 450 ~ 2850 450 ~ 2850 560 ~ 3160 560 ~ 3160 560 ~ 3160 560 ~ 3160 560 ~ 3160 700 ~ 3400 700 ~ 3400 700 ~ 3400 700 ~ 3400 700 ~ 3400

Model HT311 HT316 HT312 HT313 HT314 HT351 HT356 HT352 HT353 HT354 HT451 HT452
Max. Flow m3/hr 1700 1700 1700 1700 1700 2430 2430 2430 2430 2430 3550 3550
Max.Conn.Dia. mm 400 400 400 400 400 400 400 400 400 400 500 500
Dimension - H mm 2320 2540 2945 3565 4185 2320 2540 2945 3565 4185 2590 3160
Dimension - W mm 1115 1115 1115 1115 1115 1115 1115 1115 1115 1115 1390 1390
Dimension - L(min. ~ max.) mm 670 ~ 4370 670 ~ 4370 670 ~ 4370 670 ~ 4370 670 ~ 4370 670 ~ 4370 670 ~ 4370 670 ~ 4370 670 ~ 4370 670 ~ 4370 830 ~ 5230 830 ~ 5230

Model HT453 HT454 HT501 HT502 HT503


Max. Flow m3/hr 3550 3550 5000 5000 5000
Max.Conn.Dia mm 500 500 500 500 500 H
Dimension - H mm 3270 3730 3350 3850 4450
Dimension - W mm 1390 1390 1540 1540 1540
Dimension - L(min. ~ max.) mm 830 ~ 5230 830 ~ 5230 830 ~ 5330 830 ~ 5330 830 ~ 5330

L
W

Connection Option

Threaded connection Studded connection Studded connection Flanged connection Sanitary


with alloy nozzle with alloy lining Quick-disconnect nozzle

Max. operation temp. 200°C The following materials can be applied to plates : Stainless steel : SS304, SS316L, 254SMO, 940L, 317L Nickel : Ni.200
Heat transfer area 0.1 ~ 2,600m2/set" Nickel alloy : C-276, 825, 625, Incoloy, Hastelloy Titanium : Ti.Gr.1, Ti.Gr.11
Max. operation press. 26 kg/cm3g The following materials can be applied to gaskets : NBR, EPDM, FPM, Neoprene, IIR, Butyls, Silicone, Teflon, Envelop(Special)
Max. flow rate 5000m3/hr.set

Plate heat exchanger


COMPACT HEAT EXCHANGER

Spiral heat exchanger


TYPE I (Liquid/Liquid) TYPE ll ( Condenser )

Structure
and
Principle

As the most common type, it is used for liquid-to-liquid,


gas-to-gas and gas-to-liquid heat exchange. The high- This type is suitable for cooling and heating of gas and the
temperature fluid comes in through the inlet, located in condenser for processing large-volume gases (at a low
center of the main body, to flow from outside to the inside. pressure or vacuum) and mixture of gas and/or liquid. The
Due to this counter flow, high-efficiency heat exchange is low-temperature fluid comes in through the inlet, located
available and can be used for a tiny difference in on the side of the main body, to flow to inside along the
temperature. Any type of installation (vertical or horizontal) spiral fluid passage while the high-temperature fluid
is possible according to the usage. comes in through the top and vertically flows to the
bottom.
The both ends of the heat transfer plates on the side of the
low-temperature fluid passage is blocked by welding, and
the high-temperature plates are all opened. In most cases,
this type of heat exchanger is installed vertically, but
horizontal installation is also available according to the
usage.

TYPE ( Liquid / Vapor )

TYPE ll ( Vaporizer )

This type is mostly used for the liquid-vapor exchanges


such as heaters, coolers and condensers, and has wide
range of use. The low-temperature fluid comes in through
the side of the main body to spirally flow into the inside
This type is suitable for reboilers and evaporators for all while the high-temperature vapor comes in through the
kinds of fluid especially in the vacuum status and a low- top. And the flowed-in air is distributed evenly to the front
pressure condition. The flow rate of air is maintained at a and center parts of the opened spiral-typed fluid passage,
proper level even for a large volume, and the pressure loss which generates combined flow in the spiral and axis
is minimized. It can be used for multi purposes by vertically directions. The condensed liquid and the non-condensed
connecting three units in a row. gas are discharged separately to different outlets.

Spiral heat exchanger


Leader Heat Exchanger | www.lhe.co.kr

Waste Water Cooler Waste Water Cooler PVC Slurry Heat Exchanger PCW Cooler(JWS)

TYPE IV ( Top Condenser )

The condenser on the top can be installed on the top of column or the reactor of kettle without piping work as the size of the connection
part of the inlet for incoming vapor can be adjusted according to the size of the outlet to which the spiral-typed heat exchanger. Air comes
into the pipes of the center to be divided into the spiral flow, axial flow and/or mixture of the two types of flow. The cooling fluid comes in
through the surface of the main body to spirally flow into the center, and discharged through the top. The condensed liquid is generated in
the main body or collected in the condensed liquid-collecting part of the main body.

Spiral Heat Exchanger Technical Data


Model DSP-W300 DSP-W400 DSP-W500 DSP-W600 DSP-W1000 DSP-W1200 DSP-W1500 DSP-W2000
Maxium flow m3/hr 56 75 94 114 187 228 285 374
Maxium Transfer Area m2 25 50 45 80 180 290 300 550
Chammel gap mm 5~20 5~20 5~20 5~20 5~26 5~26 5~26 5~26
Heat Transfer Thickness mm 2~3 2~3 2~3 2~3 2~3 2~3 2~3 2.5~3
Maxium nozzle size mm 80 100 125 125 150 200 250 300

Possible Manufacture Dimension of each Model


Model DSP-W300 DSP-W400 DSP-W500 DSP-W600 DSP-W1000 DSP-W1200 DSP-W1500 DSP-W2000
W (Flow width) mm 300 400 500 610 1000 1220 1524 2000
D (Outside diameter) mm 600 800 1000 1200 1400 1600 1800 2200
L (Overall length) mm 700 800 900 1000 1500 1700 2000 2500

L ( OVERALL LENGHT )
Specification W ( ROLLING PLATE WIDTH )

Minimum Maxinium N3 N2

Heat transfer Area mm 5 m2 600 m2


D ( SHELL DIA. )

Design Temperature mm -100 °C 400 °C


Design Pressure mm Full Vacuum 20 kg/cm2G N1 N4

Application Code ASME, KS, CE Mark


Standard Material Stainless steel, carbon steel
Available Material Weldable Metals, Duplex, Titanium, Hastelloy, etc. FIXED SIDE SLIDING SIDE

Spiral heat exchanger


COMPACT HEAT EXCHANGER

Spiral heat exchanger

Reactor Cooler

Benefits

The spiral heat exchanger has two metal plates in the form of spiral and comprises two fluid passages.
While the multi-pipe heat exchanger depends on the several heat transfer pipes and has a number of
fluid passages, the spiral heat exchanger has a single passage. As it can prevent adhesion of
contaminated materials lowering heat exchange efficiency, and make the fluids form the counter flow
which enables the highly efficient heat exchange.

High Total Heat Transfer Coefficient Effective Usage of Temperature Difference

The transferred counter flow enables heat exchange for


As the spiral fluid passage is likely to create turbulent and even tiny temperature difference, and thus the spiral
the optimum flow rate is obtained by how adjusting the type is optimized for saving energy.
width of the heat transfer plates and the gap of fluid
passage, the spiral heat exchanger has high heat Space Saving
transferring performance

Low Fouling Its high-performance and optimized structure allows the


compact design and low installation cost.

Easy Repair & Maintenance


The single fluid passage of one pass structure
distributes the fluid evenly to have less polluting
materials adhered. Even when they are adhered,
its self cleaning function peels off them by the The internal checkup can be done by just opening the
speed of the fluid. It can be also applied to cover of the both ends, which enables easy repair and
sludge. maintenance .

Spiral heat exchanger


Leader Heat Exchanger | www.lhe.co.kr

Alkali Solution Heater Waste Water Cooler

1. Petroleum 2. Steel & Inorganic


Usage a) Refinery a) Alumina
Produced water / Fresh water interchanger Bauxite slurry heater Bauxite slurry heater
Treated crude oil / Fresh feed water interchanger Red mud heater recovery Hydrate slurry cooler
b) Desulphurization b) Zinc
Acid gas partial condenser Stripper reboiler Zinc solution preheater Zinc solution cooler
c) Ethylene Oxide c) TiO2
Effluent gas / Feed gas interchanger
d) Ethylene Glycol
Reactor feed / Recycle Interchanger 3. Branch industries
Reactor feed heater
a) Explosives
e) Caprolactam
H2SO4 Cooler UDMH Cooler
f) Acrylic Fibers b) Waste water
Condensing of ACN recovered from the strippers Textile waste water Slurry interchanger
g) Polyester c) Photographic
Preheating of Glycol & monomer Glycol cooler Gelatine heater
h) PoIystyrenes d) Paint
Preheating of strength & additives Paint suspension cooler Fatty acid heater
i) PVC e) Pharmaceutical
PVC Slurry interchanger VCM stripper / condenser Methanol / water condenser
j) Formaldehyde Sludge interchanger Nitric acid cooler
Formaldehyde / Methanol Interchanger
Product cooler / Heater
k) ABS / SAN
Vapor condenser
l) Epoxy
Resin cooler Condenser
m) F.E & P.P
Azeotrope still Interchanger (PP) Heptane cooler
Live p.p slurry cooler Granulate water cooler

Spiral heat exchanger


COMPACT HEAT EXCHANGER

Oblong plate & shell heat exchanger

Structure and
Characteristics
Accepting the merits of the plate-type heat Cold fluid out
exchanger and supplementing the demerits of the
multi-pipe heat exchanger, the oblong plate & shell
heat exchanger has the heat plates, which are
wrinkled in the oblong shape. As its center part in Hot fluid in

shape of round is extended into the oblong plate


shape, the increased heat transfer length and area Hot fluid out
revolutionarily enhance the heat transfer efficiency. It Cold fluid in
is a high-efficiency compact and fully-welded heat exchanger of the next generation, that can be used in high-temperature
and high-pressure conditions, without a gasket.

Characteristics
High Heat Transfer Efficiency

The wrinkles of the heat transfer plates generate turbulent at a low Reynolds number, and the total heat transfer
coefficient is 3000 kcal/m2h ~ 6000 kcal/m2h (4~5 times higher than that of the multi-pipe heat exchanger).

High Pressure Resistance

The fully-welded structure of the heat transfer plates and the shell allows the maximum usable pressure up to 80 kg/cmG.

High Thermal Resistance

As it is the fully-welded type not using a gasket, the available temperature is 600 (up to 900 in maximum).

High Economical Efficiency

The price is lower than that of the multi-pipe heat exchanger. Its small size (1/4 of the multi-pipe heat exchanger) reduces the
Recuperator required space for installation and the weight, and the fully-welded type without requiring periodical replacement of a gasket
minimizes the maintenance cost. Also, the small-sized condenser for a large-capacity vapor provides prominent effects.

Oblong plate & shell heat exchanger


Leader Heat Exchanger | www.lhe.co.kr

Evaporator Lp Suction Cooler

Application

- Chemical Industry : VOC Condenser, High Temperature & Pressure Recovery System, Ethanol Condenser
- Evaporator - Condenser - Generator - EO/EG Heat Exchanger
- High Temperature & Pressure Waste Heat Recovery Heat Exchanger
- Ethanol-Condensed Solvent Recovery System
- District Heating - Hot Water Heating - Ventilation Facility
- Cooling & Heating System - Steam Heater
- Various Types of High-Temperature & High-Pressure Heat Exchangers and Waste Heat Recovery Systems

Oblong Plate & Shell Heat Exchanger Technical Data


Model 2A 2B 2B0 3A 3B 3B0 6A 6B 6C 6A1 6B1
Maxium Flow m3/hr 60 60 70 100 100 120 250 250 250 300 300
Maxium Transfer Area m2 3.0 7.0 7.5 10 24 26 70 110 150 75 120
Heat Transfer Thickness mm 0.6~0.7 0.6~0.7 0.6~0.7 0.6~0.7 0.6~0.7 0.6~0.7 0.6~0.7 0.6~0.7 0.6~0.7 0.6~0.7 0.6~0.7
Max./Min Nozzle Size mm 10 / 80 10 / 100 10 / 100 15 / 125 15 / 150 15 / 150 32 / 250 32 / 250 32 / 250 50 / 300 50 / 300

Model 6C1 6B2 6C2 10A 10B 10C 10A1 10B1 10C1 10B2 10C2
Maxium Flow m3/hr 300 330 330 900 900 900 1000 1000 1000 1150 1150
Maxium Transfer Area m2 160 130 170 400 550 700 450 600 750 650 800
Heat Transfer Thickness mm 0.6~0.7 0.6~0.7 0.6~0.7 0.7~0.8 0.7~0.8 0.7~0.8 0.7~0.8 0.7~0.8 0.7~0.8 0.7~0.8 0.7~0.8
Max./Min Nozzle Size mm 50 / 300 65 / 350 65 / 350 80 / 350 80 / 350 80 / 350 100 / 400 100 / 400 100 / 400 125 / 500 125 / 500

Possible Manufacture Dimension of each Model


Model 2A 2B 2B0 3A 3B 3B0 6A 6B 6C 6A1 6B1
W mm 350 350 350 490 490 490 795 795 795 795 795
H mm 410 600 600 580 900 900 1000 1250 1550 1000 1250
L (max) mm 500 500 570 600 600 700 1700 1700 1700 1900 1900

Model 6C1 6B2 6C2 10A 10B 10C 10A1 10B1 10C1 10B2 10C2
W mm 795 795 795 1480 1480 1480 1480 1480 1480 1480 1480
H mm 1550 1250 1550 1600 1950 2250 1600 1950 2250 1950 2250
L (max) mm 1900 2100 2100 1800 1800 1800 2000 2000 2000 2300 2300

W ( Width ) L ( Overall Length )

Specification
Minimum Maxinium
C model : Max. Oblong
Heat transfer Area 0.62 m2/set 800 m2/set
H ( Height )

Design Temperature -50 °C 800 °C B model : Oblong

Design Pressure Full Vacuum 80 bar g


A model : Disk
Application Code ASME, KS, CE Mark
The follow materials applied to plates SS304, SS316L, Titanium, Hastelloy C-276,Any other weldable metal

Oblong plate & shell heat exchanger


COMPACT HEAT EXCHANGER

Plate Coil heat exchanger

Jacket Panel heater

Structure

Structure
and
Characteristics

Hydro Forming Type Heating Panel

It has a structure, available for heat transfer with unique fluid passages inside by
welding two plates of which one side or both sides are embossed or pressed, to provide
flexibility and diversity in design, size and figure. Applicable to all weld able metals, it
can be used economically and conveniently to the liquid-liquid, liquid-gas and gas-gas
transfer, and in a high-temperature and high-pressure condition. The plate coil is a heat
Pressing Type Heating Panel exchanger that can be easily mounted inside and outside the tanks with a clamp. The
merits of our plate coil are that the customized forming for an installation site maximizes
the heat transfer efficiency and thus it can be installed regardless of the place.

Characteristics
High Heat Transfer Efficiency

The high serviced side inside the plate coil does not creates big turbulent flow and dead points, and a high film coefficient
of heat transfer can be obtained due to the large surface area, compared to the internal volume.

Diversity of Wrinkles

A standard type, suitable for each heat medium and cold medium, can be selected.

Various Option for Materials

Materials such as SS304(L), SS316(L) and Titanium Ti-Pd can be selected according to durability or corrosion
resistance.

Convenient Installation, Disassembly and Assembly

Its simple structure allows convenient installation, disassembly, assembly and scale removing.

Plate coil heat exchanger


Leader Heat Exchanger | www.lhe.co.kr

Specification
Temperature : less than 400
Heat transfer area : 0.2 ~ 20 /pc, 500 /set

A10590-C Heat Recovery Cryogenic Vacuum Chamber


Cryogenic temperature control unit for
Vacuum chamber

Feature
Double Embossed

As being embossed on both sides, easy to assemble


independently or inside vessels.

Single Embossed
As being embossed on one side, easy to assemble
Embossing Type Dimple Type outside vessels.

Crystallizer Heater & Cooler EPS Slurry Cooler (Free Flow Type) PVC Dryer Heating Panel

Application

Chemical Industry / Machinery Industry / Electro Painting / Rubber Industry / Petroleum Industry / Metal Coating /
Cryo Cylinders / Paper Manufacturing / Resins / Textile Industry / Food Industry

Plate Coil Heat Exchanger Technical Data


MODEL SPECIFICATION (AREA, m2)
B-DIMENSION (mm)
A-DIMENSION (mm) 400 900 1400 1900 2400 2900 3400
SINGLE 0.19 0.43 0.67 0.91 1.15 1.39 1.63
480
DOUBLE 0.38 0.86 1.34 1.82 2.30 2.78 3.26
SINGLE 0.29 0.65 1.01 1.37 1.73 2.09 2.45
720
DOUBLE 0.58 1.30 2.02 2.74 3.46 4.18 4.90
SINGLE 0.38 0.86 1.34 1.82 2.30 2.78 3.26
960
DOUBLE 0.77 1.73 2.69 3.65 4.61 5.57 6.53

B B
MAX. OPERATING PRESSURE UNIT : kg/cm2
MATERIAL THICKNESS SINGLE DOUBLE
1.5mm 9 6
A

STAINLESS STEEL 2.0m 13 9


2.5mm 20 14

Plate coil heat exchanger


COMPACT HEAT EXCHANGER

CHU
Compact heat exchanger unit

CHU (Compact heat exchanger unit) for district heating is an up-to-date construction method to
revolutionarily improve the construction quality, and to reduce the construction cost and period by
minimizing installation works, and piping and welding operations at sites. These are possible by
supplying the main equipments and parts such as heat exchangers, pumps and thermostats,
composing a district heating facility, in standard modules, which are designed, manufactured,
assembled, inspected and tested at the factory according to the site requirements and the
specifications required by the buyer.

Applied the compact piping design to minimize the installation space for the system.
Piping layout is structured for the maximum performance and the easiness
of maintenance.
Insulation and Piping
Applied CIP Service valve for the easiness of cleaning pipes.
Installed safety valves on the pipes for heating and hot tap water.
Adopted light materials for heat insulation and casing.
Adopted a heat insulation technology to minimize the energy loss.

CHU Compact heat exchanger unit


Leader Heat Exchanger | www.lhe.co.kr

HEAT EXCHANGER
Gasketed plate heat exchangers shall be
the standard selection, however, brazed
plate heat exchangers can be applied for
small capacity units.

CHU Technical Specification


PIPE SIZE HEATING INLINE PUMP TCV PIPE SIZE HOT WATER INLINE PUMP TCV DIMENSION
HEATING HOT WATER
Primary Second PUMP POWER SIZE Primary HOT WATER DOMESTIC PUMP POWER SIZE ( W x L X H)mm
Capacity Capacity
(Mcal/hr) SIDE SIDE QUANTITY (KW) (Mcal/hr) SIDE /DOMESTIC RETURN QUANTITY (KW)
(50%) WATER WATER (100%)
~ 300 50A 100A 2 or 3 2.2 32A ~ 100 32A 40A 40A 2 0.55 15A 2800 x 2400 x 1700
~ 400 65A 100A 2 or 3 3 32A ~ 200 50A 65A 40A 2 0.55 25A
~ 500 65A 125A 2 or 3 3 40A ~ 300 50A 65A 40A 2 0.55 32A 3000 x 2500x 1800
~ 600 65A 125A 2 or 3 4 40A ~ 400 65A 65A 40A 2 0.55 40A
~ 700 65A 125A 2 or 3 4 50A ~ 500 65A 80A 40A 2 0.75 40A
~ 800 80A 125A 2 or 3 5.5 50A ~ 600 65A 80A 40A 2 0.75 40A 3200 x 2500x 1800
~ 900 80A 150A 2 or 3 5.5 65A ~ 700 80A 80A 40A 2 0.75 50A
~ 1,000 80A 150A 2 or 3 7.5 65A ~ 800 80A 100A 50A 2 1.1 50A
3300 x 2600 x 1950
~ 1,100 80A 150A 2 or 3 7.5 65A ~ 900 80A 100A 50A 2 1.1 65A

NOTE
1. INLET, OUTLET TEMPERATURE
HEATING 1'ST SIDE 115°C/50°C, HEATING 2'ST SIDE 45°C/60°C (radiation HEATING)
HEATING 1'ST SIDE 115°C/55°C, HEATING 2'ST SIDE 50°C/70°C (CONVECTION HEATING)
RE-HEATING 1'ST SIDE 55°C/35°C, RE-HEATING 2'ST SIDE 75°C/55°C
PRE-HEATING 1'ST SIDE 35°C/15°C, PRE-HEATING 1'ST SIDE 55°C/35°C

2. Standard pressure drop of Temperature Control Valve : 0.3 bar


PUMPS CONTROL VALVES
3. HEATING INLINE PUMP HEAD
Case for Heating (50% flow late x 3ea) - 1 pump(STAN-BY)
Number of households 0~150 households 151~250 households 250 households
LOW FLOOR HEAD 18M 19M 21M
HIGH FLOOR HEAD 19M 21M 23M
SENSORS & GAUGES Case for HOTWAER 100% flow late x 2ea, HEAD: 7M.

4. Condition of PIPE FRICTION LOSS


District heating 20 / heating 10 / Hotwater 10 (Unit :mmAq/m)

5. Pressure Drop of HEATING PLATE HEAT EXCHANGER


Primary side : 0.2bar, Second side : 0.3ba
STRAINER & VALVES
6. Pressure Drop of HOT WATER PLATE HEAT EXCHANGER
Primary side RE-HEAT &PRE-HEAT : 0.1bar Second side RE-HEAT & PRE-HEAT : 0.08bar

7. HOT WATER OF CAPACITY


In the case of 150Mcal/hr low, application of ONE-STAGE HOT WATER SYSTEM
More than 150Mcal/hr, TWO-STAGE HOT WATER SYSTEM does application
(RE-HEATING, PRE-HEATING), division of capacity is 50% : Divide by 50%
CONTROLLER

CHU Compact heat exchanger unit


COMPACT HEAT EXCHANGER

Special type Gas heat exchanger

Plate Coil Type Welded Type

Type

The welding-typed gas cooler is manufactured by press


forming thin metal plates into a concavo-convex shape,
assembling several pairs of sheets staggered (two sheets
as a pair) to become a block, and finishing the both ends
with welding. Material, thickness and figure of the
element can be selected according to the various
The plate-coil-typed gas cooler is a straight & turbulent components and temperatures of the heat absorbing and
flow and counter flow-typed heat exchanger that prevents emitting fluids. It is mainly used for the waste heat
mixture of both fluids by welding the dimple-typed plates collecting system, and processes of temperature
to combine and connect several plate coils, forming the elevating, cooling and condensation.
fluid passages inside, with the header.
The plate coil has a structure to withstand the pressure,
and its self-cleansing function, by the high heat transfer
efficiency and the internal dimple wave form, allows
maintaining the low pollution rate against gas. Its
assembly-typed structure enables easy access to the gas
part (polluted fluid) without removing the piping
arrangement and thus convenient maintenance and
cleaning. The gap between the heat plates can be 10
mm~ 40 mm. Non-gasket feature does not generate a
gasket problem due to temperature and pressure.
Design Temperature : -40 ~ 400'c Recuperator

Gas heat exchanger


Leader Heat Exchanger | www.lhe.co.kr

Air Preheater

Characteristics

High Efficiency and Low Fouling Rate


Characteristics
& Usage As manufacturing the element plates in the methods of wave form and concavo-convex, this type of heat exchanger
can get comparatively high heat efficiency, and maintain a low fouling rate for gas due to its self-cleansing function by
the internal wave form.

Light and Compact Design

Its larger heat transfer area and higher heat transfer rate, compared to the tube type of the same size, allow light and
compact design.

Various Options for Material

You can select the optimized material according to temperatures, components and figures of the heat-absorbing and
heat-emitting parts.

Applicable to High Temperature

It is designed to have a structure that can absorb heat expansion sufficiently by selecting a heat-resistant steel material
against high temperature.

Wide Range of Applications

It can be widely applied to variety of area with high-efficiency conditions, compared with the existing low-efficient and
narrow-applicable gas-to-gas heat exchangers.

Application

- For Industrial Furnaces : Hot Blast Stove, Heat Treatment Furnace, Annealing Furnace, Soaking Pit
- For Drying Furnaces : Paint Drying Furnace, Food Drying Furnace
- For Deodorizing Furnaces : Direct-Combustion-Typed Deodorizing Furnace, Pre-heating Odious Gas in Deodorizing Furnace
- For Treatment of Exhaust Gas : Protecting Bag Filter, Preventing White Smoke, Recollecting Exhaust Gas,
Weaving Industry, Dying, Paper Manufacturing
- For Incinerating Furnace : Incinerating Furnace for Waste Liquid, Waste Incinerating Furnace
- For Chemical Plants

Gas heat exchanger


COMPACT HEAT EXCHANGER

Pressure Vessel
Special type Mist & dust collector

Characteristics
As a combined device of a new concept that the principle of the heat exchanger is applied to the cyclone, the mist & dust
collector revolutionarily increases collecting rate of dust and mist in exhaust gas by condensing them and thus enlarging
moisture particles with rotation in the cyclone.

1st Mist & Dust Collector 2nd Mist & Dust Collector

3rd Mist & Dust Collector Mist & Dust Collector

Gas

소재투입
Scrubber

Blower

제품 CH.W CH.W

CH.W CH.W
CH.W

CH.W
Condensate Condensate

Gas Cooler(Final Condenser) 2nd Mist & Dust Collector 1st Mist & Dust Collector

Mist & Dust collector


Leader Heat Exchanger | www.lhe.co.kr

ON DEVELOPING COMPACT HEAT EXCHANGER

COMPABOX heat exchanger

COMPABOX is the fully welded type which can be used for the operating condition under high pressure and
temperature. It has not only excellent durability against thermal shock but also high efficiency comparing with
the small space. Especially multi-pass structure and compact design allow that it can be operated the
condensation and cooling at one time and used for the system which has the limitation of space for
installation. It’s normally applied for the fluid under high temperature & pressure and environment which can
be easily polluted like a steel, chemical & petroleum industry as a pre-heater, condenser and cooler.

Counter-current Heat Exchanging and the Convenience of Maintenance


Characteristics

Like conventional Plate Heat Exchangers COMPABOX adopted counter-current heat exchanging system to have higher
efficiency than other manufacture’s free flow system, and let the whole four covers openable for the easy maintenance
and cleaning.

COMPABOX Heat Exchanger Technical Data


Model HCB051 HCB052 HCB071 HCB072
Dimension-A mm 480 480 750 750

Dimension-B mm 980 1960 980 1960

Heat Transfer Area. m2 0.48 0.96 0.75 1.5


Plate Depth. mm 6 (8) 6 (8) 6 (8) 6 (8)

Design Temperature : Up to 350°… Design Pressure : Up to 35bar

COMPABOX heat exchanger


ON DEVELOPING COMPACT HEAT EXCHANGER

DOUBLE WAVE heat exchanger

Double Wave Heat Exchanger maximized the heat transfer area by adding small-
scale corrugation to the existing large-scale hence smaller floor space required,
and the structure of small-scale corrugation enables less fouling and greater
turbulent flow for the maximum heat transfer efficiency.

Characteristics
Air-cooled Double Wave Corrugation structures are specially designed to not allow internal and external contamination by
preventing the internal fluid directly contacting from outer air and splashing to the outside. It also maximized heat transfer
efficiency through its super-efficient heat plate which allows to form turbulent flow easily under the low flow velocity, and
maintenance easiness.
A

DOUBLE WAVE Heat Exchanger Technical Data


Model DW 120 Series DW 120L Series

Plate Hole Dia. ( C ) mm 120 120

Max. Conn. Dia. mm 150 150


Plate Depth. mm 5 5

HPC ( B ) mm 412 412

Length ( A ) mm 1464 3004

DOUBLE WAVE heat exchanger


Leader Heat Exchanger | www.lhe.co.kr

ON DEVELOPING COMPACT HEAT EXCHANGER

Super High Efficiency Plate Heat exchanger

Super High Efficiency Plate Heat Exchanger


(SHEPHE) is gasketed plate heat exchanger with
lower plate gap from 2.4 to 2.7mm. To meet the
expectation of higher heat transfer efficiency with
less energy consumption we are developing Super
High Efficient Plate which satisfies the harsh
operating condition requiring less than 1 C L.M.T.D
and higher pressure. Super High Efficiency Plate
Heat Exchanger shall be mostly applied to district
heating and cooling facilities in Middle East
Countries.

A
LMTD 1 °C
HPC
NTU 9
Characteristics PRESSURE DROP : 30~50 kPa
OPERATING PRESSURE 10~ 20 bar
ROOM HEIGHT 3.5 ~ 6.4 M
FLOW RATE 100 ~ 600 m3/h

Super High Efficiency Plate Heat exchanger Technical Data


Model SH 300 Series SH230 Series SH100 Series SH040Series

Plate Hole Dia. mm 330 225 106 42


Max. Conn. Dia. mm 350 300 150 40

Dimension-A mm 860 746 435 250

HPC mm 486 465 223 105

Super High Efficiency Plate heat exchanger


COMPACT HEAT EXCHANGER

PHE Gaskets

Our company is a top leader of rubber gasket for Plate Heat Exchangers used in diversified industries.
Automotives, shipbuildings, marine, heavy industries, steel works, power plants, chemical plants, food
industries & etc. require excellent durability of gaskets due to their highest operation ratio.
We can provide total solution to our customers with rich experiences in PHE GASKET MARKET.

Gaskets
Leader Heat Exchanger | www.lhe.co.kr

Possession of the fundamental technology

Our products are manufactured by our unique technology using the mixed raw materials according to
mixture proportion of our own development.

We can provide rapid service and have a various selection of gasket molds.

Gaskets
COMPACT HEAT EXCHANGER

PHE Gaskets

Comparative Properties of Rubbers


Heat and Oil Resistance of Elastomers ASTM Classifications
D1418 ERR, EPDM IIR NBR H-NBR FKM FVMQ ACM CR CSM NR
D2000 DA AA BF BF HK FK DH BC CE AA
Density,Mg㎥ 0.86 0.92 1.00 1.00 1.85 1.47 1.09 1.23 1.10 0.93
Hardness,Shore A 75-90 70-80 75-85 75-85 60-95 40-70 40-90 20-95 45-95 20-90
Typical Tensile Strength
Pure Gum, Mpa 3 10 7 13 14 - 3 21 14 21
Reinforced, Mpa 21 14 14 24 14 10 12 21 19 21
Resilience
Room Temp. VG L G G L G L VG G E
FKM : fluorocarbon Hot VG VG G G VG VG VG VG G E
FVMQ : fluorosilicone
Resistance to
H-NBR : hydrogenated nitrile
Tear G G F F F P P G F E
EPDM : ethylene propylene terpolymer
Abrasion G G G G G P F-P E E E
NBR : acrylonitrile butadiene
IIR : Butyl Compression Set VG F G G VG VG G F-G F G
ACM : Polyacrylic Weathering E VG F-G VG E E E E E E
CR : Neoprene Oxidation E E G E O E E VG E G
CSM : Hypalon Ozone E G P VG O E G VG O P
NR : Natural Rubber Temperature Range
High Temp. E G VG VG O O E G VG G
Low Temp. E G G G P-G O P G F E
Aqueous Fluid Resistance
Dilute Acid E E G G E E F-P VG E E
Conc.Acid G E G G E G F-P G E F-G
Water E VG F-G G VG VG P G G VG
Organic Fluid Resistance
Aliphatic(A) P P E E E E E G G P
Oxygenated(B) G G P P P-G P P P P F
Chlorinated(C) P P P-F P-F E G P P-F P-F P
Aromatic(D) P P G G E E F-P F F-G P
Fuels(E) P P E E E E G G E P
Fats and Oils(F) G VG E E E E VG G G P-G
Permeability F-P VL L L L F L L L F
Flame Resistance P P P P G G P G F-G P
Dielectric Properties E G-E P P G G F-P VG E E
Key to Ratings O = Outstanding E = Excellent VG = Very Good G = Good F = Fair P = Poor L = Low VL = Very Low
Footnotes A = hexane,isooctane,etc B = acetone,methyl-ethyl ketone,etc C = chloroform,perchlorethylene,etc
D = toluene,xylene,etc E = kerosene,gasoline,etc F = animal and vegetable product

Gaskets
Leader Heat Exchanger | www.lhe.co.kr

Lab Service

Our lab facilities have capability of testing rubber physical properties, analyzing organic & inorganic
materials in fluids and predicting durability of gasket by simulation tester.

All batches of rubber compounds are efficiently inspected by proper


Physical Properties equipment and controlled statistically. All the processes are under
quality control system.

Material analysis
Scanning electronic microscope, FTIR, TGA, PGC & etc can detect and analyze unknown materials
which come out during operation of PHE.

Simulation test

For reliability of gasket we perform the simulation test of all types


periodically.
All the test conditions are calculated thru actual results of PHE
operations and the tests are performed under severer design condition.

Traceability
Compounding Molding Postcuring shipping

B/T No. Lot No. Lot No. Lot No.

Traceability

Gaskets
COMPACT HEAT EXCHANGER

Quality
Management System

LHE is offering high quality service in order to satisfy the customers and we constructed quality
management system according to the ISO 9001:2000 standard acquired.
We are performing heat plate crack detection system by using ”vacuum leak detecting technology”.

PED Certificate No. : 0038/PED/MUM/0410015/1 ISO 9001 Approval Certificate No. : SEO 0041007
Original Approval : 01 June 2004 Original Approval : 21 Jun 2004
Current Certificate : 06 June 2007 Current Certificate : 16 August 2008
Certificate Expiry : 31 May 2010 Certificate Expiry : 15 August 2011
Certificate Orgonization : Lloyd Register Issued By : LRQA Ltd.
National Board ASME Stamp : U ISO14001 Approval Certificate No. : SEO 6003542
Issue Date : January 11, 2008 Original Approval : 22 July 2008
Expiration Date : January 11, 2011 Current Certificate : 22 July 2008
Certificate Expiry : 21 July 2011
ASME "U" Stamp Scope : Manufacture of pressure vessels
Issued By : LRQA Ltd.
Certificate No. : 33,038
Authorized : December 1, 2004 ISO18001 Approval Certificate No. : SEO 6003543
Revised : July 18, 2006 Original Approval : 19 July 2008
Expires : January 11, 2008 Current Certificate : 19 July 2008
Issued By : Boiler And Pressure Vessel Committee Certificate Expiry : 18 July 2011
Issued By : LRQA Ltd.
CLASS DNV, ABS, LR, GL, BV, NK, KR, CCS, RS, RINA, ETC.

Cad Heat Plate Leak Detection System Pilot Testing Room Light Box Tester

Quality management system


Leader Heat Exchanger | www.lhe.co.kr

| Certificates |

Certificates
COMPACT HEAT EXCHANGER

Reference data

To select a high efficient heat exchanger suitable for the special purposes, operational temperature, pressure, physical
properties of the fluids, limitation of the installation space, and maintenance requirements should be considered.
The properties of the fluids are the basic standards for the selection, but economic factors such as operational and
maintenance costs shall be considered as well. We, LHE Co., Ltd. always welcome your request for selecting the most
suitable heat exchanger meeting your requirement.

Guide for selecting Heat Exchangers (LHE)


Plate & Frame Spiral Oblong Plate & Shell Plate Coil
Heat Exchanger Heat Exchanger Heat Exchanger Heat Exchanger
Performance Data
Pressure range (F .V to kg/ G) 26 20 80 12
Temperature range ( ) -30 to 180 -40 to 400 -50 to 600 -30 to 400
Service
LIquid / Liquid 1 1 1 2
Gas / Liquid 2-3 1-3 1-3 1-3
Gas / Gas 2-3 2-3 2-3 1-3
Condensation 1-3 1-3 1-3 1-3
Vaporization 2-3 1-3 1-3 2-3
Nature of Media
Corrosive 1 3 2 2
Aggressive 3 2 3 3
Viscous 1 1 1 1
Heat sensitive 1 1 1 2
Hostile reactions 3 2 2 2
Fibrous 4 1 4 1
Slurries and suspensions 3 1 3 1
Fouling 1 1 2 1
Inspection
Corrosion A A B A
Leakage A A A A
Fouling A A B B
Maintenance
Mechanical cleaning A A B B
Modification A C C C
Repair A (A) A A
1 UsualIy best choice 4 Seldom best choice Depending on Operating pressure, gas vapor density etc.
2 Often best choice A Both sides
3 Sometimes best choice B One side
C No side

Reference data
Leader Heat Exchanger | www.lhe.co.kr

General data for compact heat exchangers (LHE)


Plate & Frame Spiral Oblong Plate & Shell Plate Coil
Heat Exchanger Heat Exchanger Heat Exchanger Heat Exchanger
Surface area per unit ( ) 0 ~ 2,000 0 ~ 600 0 ~ 500 0 ~ 500
Liquid flow rates per unit ( /h) 3,400 720 1,500 3,500
Suitable for Liquid condensate, Liquid oil, steam, Liquid oil, condensate, Liquid oil, steam,
steam, oil, etc vapors(one side), boiling steam, vapors, vapors, gas(air), etc
liquids,gas(air), etc gas(air), etc
Normal k with normal deposits1) ( kcal/ h )
water 2,500 ~ 6,000 1,700 ~ 4,000 2,650 ~ 5,700 500 ~ 1,700
water solution, 50 cSt 600 ~ 1,500 500 ~ 1,100 650 ~ 1,600 400 ~ 800
mineral oil, 50 cSt 250 ~ 1,000 200 ~ 500 260 ~ 1,100 200 ~ 300
organics, I~10 cS4 700 ~ 2,100 300 ~ 1,500 750 ~ 2,200 300 ~ 1,200
Channel spacing (mm) 1.6 ~ 6.0 5 ~ 28 2.5 ~ 3.5 10 ~ 100
Plate gauge (mm) 0.4 ~ 1.0 1.8 ~ 4.0 0.6 ~ 0.8 1.5 ~ 3.5
Materials available
Stainless steel 18 8
Stainless steel 18/10/2.5
Titanium , Ti-Pd
Cu, Ni, Albrass -
Monel
Others
Over-all dimensions nozzles excluded
width, smallest ~ biggest unit (m) 0.1 ~ 1.0 0.2~ 2.0 0.19 ~ 1.0 0.2 ~ 1.5
length, smallest ~ biggest unit (m) 0.2 ~ 3.6 1.0 ~ 200 0.19 ~ 2.0 0.5 ~ 5.0
height, smallest ~ biggest unit (m) 0.3 ~ 4.0 0.5 ~ 2.8 0.3 ~ 2.5 1.0 ~ 6.0
diameter, smallest ~ biggest4 unit (m) 0.25 ~ 2.5 0.2 ~ 1.0 -
1 ) Values normalIy reached when, from economic point of view the most favorable pressure drop can be utilized.

Conversion factors
Volume 1 = 35.3 cu.ft 1 cu.ft = 16.04
1 = 264.2 gallon 1 gallon = 0.0283
Mass 1 kg =2.205 Ib 1 Ib = 0.454 kg
Density 1 kg/ = 0.0624 Ib/cu.ft 1 Ib/cu.ft = 16.02 kg/
Pressure 1 kg/ = 14.223 psi 1 psi = 0.0703 kg/
1 kg/ = 0 098 MPa 1 MPa = 10.197 kg/
Heat 1 kcal = 3.968 BTU 1 BTU = 0.252 kcal
1 kcal = 4.187 kJ 1 kJ = 0.2388 kcal
Latent heat 1 kcal/kg = 1 .80 BTU/Ib 1 BTU/Ib = 0.556 kcal/kg
Specific heat 1 kcal/kg = 1 BTU/Ib 1 BTU/Ib = 1 kcal/kg
Heat flow rate 1 kcal/h = 3.968 BTU/h 1 BTU/h = 0.252 kcal/h
Conductivity 1 kcal/mh = 0.672 BTU/ft h BTU/ft h = 1.488 kcal/mh
Heat transfer coefficient 1 kcal/ h = 0.205 BTU/ft h 1 BTU/ft h = 4.882 kcal/ h
Overall 1 kcal/ h = 1 .163 W/ 1 W/ = 0.86 kcal/ h
Dynamic viscosity 1 kg/mh = 0.278 cP 1 cP=3.6kg/mh
Ton of refrigeration 1 RT = 3320 kcal 1 US RT = 3024 kcal

Reference data