Data sheet
Transient Recorder and Data
Acquisition System
Special features
GEN4tB is a portable, rack mountable transient The 250 MS/s cards can be used for ultra-fast
recorder and data acquisition system, including voltage or strain gauge measurements like
Perception acquisition software. “Split-Hopkinson bar” or using the fiber optic
The wide operating temperature range digitizers in a real high voltage/high power
(-20 °C to +60 °C) enhances the cold startup environment. Data is stored on the inputs cards
as well as the use in warm environments. built-in memory and/or streamed with
By selecting up to four input cards with sample 100 MB/s aggregate to a remote PC running
rates from 200 kS/s to 250 MS/s GEN4tB turns Perception software. For higher streaming
into an entry level DAQ, a high end transient rates of 400 MB/s a 10 Gbit electrical or optical
recorder or even a mix. Using the Basic cards Ethernet option is available. For maximum
the GEN4tB can be used to record voltages, or reliable data storage GEN4tB supports an
vibrations using IEPE transducers, with up to (optional) built-in solid state drive at 350 MB/s.
32 channels simultaneously at up to 2 MS/s. The optional EtherCAT® or CAN/CAN FD
Using the unique real-time math enabled output enables low latency real-time stand-
1.5 kV power cards turns GEN4tB into a cost alone data exchange.
effective, powerful 12 channel power analyzer Copper or optional optical Ethernet allow fast
with real-time power computation and and secure connection to the PC, while the
harmonic analysis. With the Universal card optional Master/Sync port allows using two
GEN4tB can be used in material testing with mainframes in parallel without any further
physical sensors like strain gauges, IEPE hardware needed. Multiple mainframes can be
sensors or thermocouples using up to used simultaneously using the Master/Sync
500 kS/s sample rate. option connector, while PTPv2 and IRIG/GPS
timing allow synchronization between
mainframes and external devices.
Corporate network
Corporate network
Corporate network
External
Option Start, Stop, Digital
RJ45 Optical Alarm, Trigger Optical Events/Timer/
Network Network Event Master/Sync Counter Analog Inputs Analog Inputs Analog Inputs Analog Inputs
CPU
Acquisition System
System Time Base and Synchronization
Central time base for all acquisition cards
Accuracy ± 3.5 ppm; aging after 10 years ± 10 ppm
Base Decimal
Synchronization sources IEEE1588:2008 PTPv2 (Precision Time Protocol) using an End-to-End protocol
Master/Sync; Sync or Master mode on built-in connector
Master output card (G083): Option to synchronize up to 16 Sync mainframes
PTP synchronization accuracy ± 150 ns; no Ethernet switch used
When network switches are required, use only PTP IPv4 aware switches that support End-
to-End set-ups. Overall accuracy depends on PTP switch used.
Note: PTP aware switches require PTP setup, refer to the operating manual of the switch
for more details.
Acquisition Slots
Unused slots must be covered using the GEN DAQ blind panel. This closes the mainframe front panels for EMC/EMI and safety compliance
and also regulates the internal airflow to cool the acquisition system correctly.
Maximum slots 4
Acquisition cards Any combination of GEN DAQ acquisition cards which support fast data streaming
Digital Event/Timer/Counter connector 2; Connected to slots A & B and C & D
Thermal control Every acquisition card and the acquisition system monitors its own temperature and status.
This is used to regulate fan speeds and reduce noise while optimizing airflow and power
consumption.
Calibration Any changes to the acquisition system configuration may change its internal thermal
gradients. As accurate calibration relies on a steady and repeatable thermal environment,
calibration is void if changes are made in the configuration. For information on calibration
impact, please refer to the individual card specifications.
Status Display
D D
C C
B B
A A
Air PTP Enabled Access for Factory Installations I/O Digital Event/Timer/
Filter Access Network RJ45 (For Qualified Personnel Only) Connector Counter
1-GEN4tB
250VA
100-240V ~
47-63Hz
4AF
A01 USB1
USB2
USB3.0
PTP Enabled
Network RJ45
USB1
USB2
USB3.0
PTP Enabled
Optical Network
(1) Tested using circular recording for 48 hours. Test setup uses a Windows® 7 PC with Intel i7 CPU and SSD with sustained write speeds
exceeding 250 MB/s.
(2) Linux GPL open source code can be downloaded from the HBM website.
Original Data
RAID
Compressed Data
PC
32 bit
32 bit
24 bit
24 bit
Removable Disks
(1) Test setup uses a Windows® 7 PC with Intel i7 CPU and SSD with sustained write speeds exceeding 250 MB/s.
(2) Compression ratio is defined by the ADC channel width. For details, please refer to the "Streaming Compression Ratio" table (below).
Rate is valid before decompressing storage data to maintain backward PNRF compatibility.
Master/Sync
Connector
(Requires G091 option)
Mainframe1
Transferred Trigger
Trigger origin
Mainframe 2
Transferred Trigger
Mainframe N
(1) tphase Maximum phase difference between signals. (This specification is not affected by any of the other specifications).
(2) tstart Maximum delay between the start of recording for each mainframe.
(3) tstop Maximum delay between the stop of recording for each mainframe.
(4) ttrigger Maximum delay to transfer a trigger from one mainframe to all other mainframes.
(5) Note on trigger exchange
Trigger exchange is included in the Master/Sync cable. All other synchronization modes require that the mainframes are connected
from each External Trigger Out to each External Trigger In on all the mainframes in order to exchange triggers.
(1) If an analog and/or digital filter is used, extra delay will be added, depending on the type of filter and signal frequency.
Slot C
Slot D
Slot B
Slot A
Acquisition Acquisition Acquisition Acquisition
card card card card
Backplane
“1”
Logic value
“0”
-30 +0.7 +2 +30
Input voltage
31 31 32 33 34 35 36 37 38 39 40 41 42 43 44 44
16 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 30
11 2 3 4 5 6 7 8 9 10 11 12 13 14 15 15
PIN 1 - Event Input A1/C1 & Reset Timer/Counter A2/C2 PIN 16 - Event Input B4/D4 & Clock Timer/Counter B4/D4 (1) PIN 31 - Event Input B15/D15
PIN 2 - Event Input A2/C2 & Direction Timer/Counter A2/C2 PIN 17 - Event Input B5/D5 & Clock Timer/Counter B4/D4 (1) PIN 32 - Event Input B16/D16
PIN 3 - Event Input A3/C3 & Clock Timer/Counter A2/C2 PIN 18 - Event Input B6/D6 & Clock Timer/Counter B4/D4 (1) PIN 33 - Event Input A13/C13
PIN 4 - Event Input A4/C4 & Clock Timer/Counter A4/C4 (1) PIN 19 - Event Input B7/D7 & Clock Timer/Counter B3/D3 (1) PIN 34 - Event Input A14/C14
PIN 5 - Event Input A5/C5 & Clock Timer/Counter A4/C4 (1) PIN 20 - Event Input B8/D8 & Clock Timer/Counter B3/D3 (1) PIN 35 - Event Input A15/C15
PIN 6 - Event Input A6/C6 & Clock Timer/Counter A4/C4 (1) PIN 21 - Event Input B9/D9 & Clock Timer/Counter B3/D3 (1) PIN 36 - Event Input A16/C16
PIN 7 - Event Input A7/C7 & Clock Timer/Counter A3/C3 (1) PIN 22 - Event Input B10/D10 & Reset Timer/Counter B1/D1 PIN 37 - Event Output B2/D2
PIN 8 - Event Input A8/C8 & Clock Timer/Counter A3/C3 (1) PIN 23 - Event Input B11/D11 & Direction Timer/Counter B1/D1 PIN 38 - Event Output B1/D1
PIN 9 - Event Input A9/C9 & Clock Timer/Counter A3/C3 (1) PIN 24 - Event Input B12/D12 & Clock Timer/Counter B1/D1 PIN 39 - Event Output A2/C2
PIN 10 - Event Input A10/C10 & Reset Timer/Counter A1/C1 PIN 25 - Event Input B13/D13 PIN 40 - Event Output A1/C1
PIN 11 - Event Input A11/C11 & Direction Timer/Counter A1/C1 PIN 26 - Event Input B14/D14 PIN 41 - Ground
PIN 12 - Event Input A12/C12 & Clock Timer/Counter A1/C1 PIN 27 - Ground PIN 42 - Ground
PIN 13 - Event Input B1/D1 & Reset Timer/Counter B2/D2 PIN 28 - Ground PIN 43 - +5 V Power
PIN 14 - Event Input B2/D2 & Direction Timer/Counter B2/D2 PIN 29 - Ground PIN 44 - +5 V Power
PIN 15 - Event Input B3/D3 & Clock Timer/Counter B2/D2 PIN 30 - Ground
Figure 1.16: Pin diagram for Digital Event/Timer/Counter connector 1(AB) and 2(CD)
(1) Timer/Counter channels are only available if a GN310B/GN311B or GN610B/GN611B card is installed.
(1) This product complies with the essential requirements of applicable and relevant regulations of the United Kingdom (UK).
Adress of Manufacturer, importer and/or representative:
Hottinger Brüel & Kjaer GmbH
Im Tiefen See 45
64293 Darmstadt
Germany
WARNING
Use HBM approved transceivers
only.
G091: 2 Gbit Optical SFP Module Multi Mode 850 nm (Option, to be ordered separately)
Small Form-factor Pluggable (SFP)
Optical transceiver used for:
– Multi Mode 850 nm 1 Gbit optical network support
– GN1202B optical front end connection
– GEN DAQ optical Master/Sync connections
WARNING
Use HBM approved transceivers
only.
mPCIe conn
I/O con
Mini PCI Express
Option Card
Time Base
I/O con
XMC Connector
PMC Connector
Synchronization
System Trigger
XMC or PMC
Recording Control
Option Card
Backplane
I/O con
XMC Connector
PMC Connector
XMC or PMC
Communication
Option Card
and
Fast Data Streaming
EtherCAT® Controller
I/O Connector
RJ45
Input Clock
Sync Manager
XMC Connector
SDO
2 * Shielded CAT5e
PDO
Output
RJ45
Control
1-G082
(1) EtherCAT® is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.
(2) For more details about the cables, please refer to the “EtherCAT_DesignGuide_en.pdf” from Beckhoff (www.beckhoff.com).
Time Base
PMC Connector
SFP Master Output
Module in Carrier System Trigger,
Recording Synchronization
XMC Connector
SFP+ SFP+
Module Carrier Dual Channel
Optical See table below for 10 Gbit
Cable supported SPF+ option Ethernet
SFP+ Controller
Carrier
1-G064
Figure 1.24: Block diagram 10Gbit Ethernet card, optical (G081 required)
Maximum number of Ethernet option cards One Ethernet option card per mainframe, cannot be combined with 1-G084
Network interface Up to two interfaces each 10 Gbit/s optical using SFP+ modules with LC connectors
Ethernet Speed 1 or 10 Gbit (auto detection)
SFP+ Module selection 1-G065 1-G066 1-SFP-10GBIT-RJ45
10GBASE-SR (Optical) Yes No No
10GBASE-SR (Optical) No Yes No
10GBASE-T (Electrical) No No Yes
Optical Wavelength 850 nm 1310 nm -
Connector type LC LC RJ45
Required cables
Multi Mode OM3 cable KAB280 - -
Single Mode OS2 cable - KAB288 or KAB290 -
Electrical cable - - CAT6A or higher
Maximum cable length 82 m (269 ft) 10 km (6.2 mi) 100 m (330 ft)
TCP/IP IPv4
Address setup DHCP/Auto IP or fixed IP
DHCP setup When DHCP fails, the APIPA (Automatic Private IP Addressing) setup is used similarly to
Windows® PCs
Gateway setup Gateway setup supported for control through VPN and/or Internet
TCP/IP IPv6 Not supported
PTPv2 (IEEE1588:2008) synchronization Not supported on Ethernet option cards
Wake-on-LAN Not supported on Ethernet option cards
Multiple Ethernet use cases PTPv2 (IEEE1588:2008) can be used on a separate 1 Gbit Ethernet interface
A combination of 10 Gbit and 1 Gbit Ethernet interfaces is supported
Maximum transfer speed
Continuous recording to remote PC 400 MB/s(1)
Temperature Range
Operational 0 °C to 40 °C (32 °F to 104 °F)
Non-operational (Storage) -55 °C to +85 °C (-67 °F to +185 °F)
(1) Tested using circular recording for 48 hours. Test setup uses a Windows® 7 PC with Intel i7 CPU and SSD with sustained write speeds
exceeding 700 MB/s and a 10 Gbit Ethernet link.
1-G066: 10 Gbit Optical Network SFP+ module 1310 nm (Option, to be ordered separately)
GEN DAQ 10 Gbit Ethernet SFP+, 1310 nm Single Mode, up to 10 km optical cable length supported, LC connector support.
10 Gbit SFP+ modules are not compatible with the 1 Gbit SFP modules.
Ripcord
RS422
Shunt/Zero
Electric Level
Conversion and
Buffering
RPM IN
RS422 RS422
TTL
To GEN DAQ
Event Inputs
TTL
G070A Power
Note For more details, please refer to data sheet “B4229 en GEN series G070A Torque/RPM adapter”.
32 X Isolated Input
+ FODM8071
A +5V
If
50Ω
C
– 562Ω
32 X
To mainframe
shield
(optional)
4 X Isolated output
(only from mainframe digital IO)
VOS617A
C + 430Ω
If
44 pin HD male
Ic To mainframe
Digital Event/Timer/Counter
E – connector
(cable included)
4X
Note For more details, please refer to data sheet “B4232 en GEN series G072 230 Volt RMS Isolated Digital Event adapter”.
Master
Mainframe
IRIG
Time Code
GMR1000
Generator DAY HOUR MINUTE
PTP NTP LOCK
Copper Ethernet
with PTP
Optical Ethernet
with PTP
PC or Laptop
Copper Ethernet with Perception
Outdoor Indoor
GPS Antenna Optical Ethernet PoE Injector
Mains Power
Outdoor Class 4
Connector
Surge Protector
NOTE:
Master Mainframe
Keep the cable length between the wall and the
Surge Protector as short as possible.
Optical Ethernet
with PTP
Copper Ethernet
Outdoor Class 4
Connector
1-GEN4tB
250VA
100-240V ~
47-63Hz
4AF
A01 USB1
Master Mainframe
(GEN4tB rear view)
USB2
USB3.0
Surge Protector
1
1MΩ 70V DC
Isol ≤70V DC
D D
1
Master Mainframe
1MΩ 70V DC
C
Isol ≤70V DC
C
1
1MΩ 70V DC
Isol ≤70V DC
B B
OPT.
PMC XMC B
PMC XMC A
A A
M/S
M/S
4
1
Keep the cable length between the wall and
the Surge Protector as short as possible.
HDD
Power
7tA PTP2
PTP1
CAL
M/S
I/O
2
CAT II 600V
2MΩ 1kV DC
CAT II 600V
2MΩ 1kV DC
CAT II 600V
2MΩ 1kV DC
CAT II 600V
2MΩ 1kV DC
CAT II 600V
2MΩ 1kV DC
CAT II 600V
2MΩ 1kV DC
!
!
FAST
1
1MΩ 70V DC
Isol ≤70V DC
8
1
FAST
1
1MΩ 50V DC
1-GEN4tB
250VA 0
100-240V ~
47-63Hz
4AF
16
15
14
13
12
11
10
9
A01 USB1
USB2
OPT.
PMC XMC B
PMC XMC A
USB3.0
Sync Mainframes
M/S
M/S
4
Optical Master/Sync
Copper Ethernet
Company Ethernet
Figure 1.35: GPS setup for tethered mainframe with Master/Sync connected Sync mainframes
Outdoor Class 4
Connector
NOTE:
Keep the cable length between the wall and
the Surge Protector as short as possible.
HDD
Power
7tA PTP2
PTP1
CAL
M/S
I/O
M/S
6
1
CAT II 600V
2MΩ 1kV DC
CAT II 600V
2MΩ 1kV DC
CAT II 600V
2MΩ 1kV DC
CAT II 600V
2MΩ 1kV DC
CAT II 600V
2MΩ 1kV DC
CAT II 600V
2MΩ 1kV DC
!
FAST FAST
8
1
1MΩ 70V DC
Isol ≤70V DC
8
FAST
8
1
1MΩ 50V DC
0
1-GEN4tB
16
15
14
13
12
11
10
250VA
100-240V ~
47-63Hz
4AF
A01 USB1
OPT.
USB2
PMC XMC B
PMC XMC A
M/S
M/S
4
USB3.0
Optical Ethernet
with PTP
Outdoor Copper Ethernet
with PTP
Copper Ethernet
with PTP
Copper Ethernet
Company Ethernet
Mainframe
IPEH-004022-005765
Termination
120 Ω
CAN FD Output
1
6 Not connected PIN PIN Assignment
GND PIN 1 - Not connected
2 PIN 2 - CAN-L
7 CAN_L
PIN 3 - GND
CAN_H 3 PIN 4 - Not connected
8
GND PIN 5 - Not connected
Not connected 4 PIN 6 - GND
Not connected PIN 7 - CAN-H
9
Not connected 5 PIN 8 - Not connected
Not connected PIN 9 - Not connected
1
6 Not connected PIN PIN Assignment CAN FD 1-2
Not connected PIN 1 - Not connected
2
CAN1-L PIN 2 - CAN1-L
7 PIN 3 - GND
CAN1_H 3 PIN 4 - CAN2-L
8
GND PIN 5 - Not connected
CAN2_H 4 PIN 6 - Not connected
CAN2-L PIN 7 - CAN1-H
9
Not connected 5 PIN 8 - CAN2-H
Not connected PIN 9 - Not connected
Data packet
Higher priority data T=0 ms T=100 ms H prio T=250 ms T=330 ms T=410 ms T=500 ms T=600 ms
Catching up over time
Higher priority data T=0 ms T=100 ms Higher prio data T=330 ms T=410 ms T=500 ms T=600 ms
Missed a transfer slot
526 mm (20.7”)
53 mm (2.0”)
280 mm (11.0”)
620 mm (24.4”)
Figure 1.45: Reusable hardcover shipping case with wheels and transport handle
Outside Dimensions 526 mm (20.7") x 620 mm (24.4") x 280 mm (11.0") (HxWxD)
Weight Empty Case 9 kg (19.8 lb)
System Storage Area Special area for system, slides in from the top for easy storage and easy removal from the
shipment case. Protects the system from impact during drops, shocks and vibrations
Accessories Area
Reliable Case Transport Wheels and handle constructed for stable transportation with a low gravitation point to
prevent the case from tumbling in any direction during roll transport
Case Extras Two lift handles and locks on side of the case for easy transport
Case Approvals IP67, ATA300, DS 81-41 and STANAG 4280
Timer/Counter channels
Maximum sample rate/
Streaming support
Analog Channels
(not multiplexed)
Digital events
Memory/card
Resolution
Slot width
Isolation
Model
Type
GN310B Balanced Differential/ yes 2M 18 bit 2 GB 6 16 2 fast 1
Current
GN311B Balanced Differential/ yes 200 k 18 bit 200 MB 6 16 2 fast 1
Current
GN610B Balanced Differential yes 2 MS/s 18 bit 2 GB 6 16 2 fast 1
GN611B Balanced Differential yes 200 kS/s 18 bit 200 MB 6 16 2 fast 1
GN815 Unbalanced Differential/ yes 2 MS/s 18 bit 2 GB 8 16 2 standard & fast 1
IEPE
GN816 Unbalanced Differential/ yes 200 kS/s 18 bit 200 MB 8 16 2 standard & fast 1
IEPE
GN840B Bridge/IEPE/Charge/ yes 500 kS/s 24 bit 2 GB 8 16 2 fast 1
4-20 mA/PT100/PT1000/
Thermocouples
GN1202B Multi Mode Optical Fiber yes 100 MS/s --(1) 8 GB 12 16 2 fast 1
GN1640B Bridge/IEPE/Charge/ yes 500 kS/s 24 bit 2 GB 16 16 2 fast 2
4-20 mA/PT100/PT1000/
Thermocouples
GN8101B Single-ended no 250 MS/s 14 bit 8 GB 8 16 2 fast 1
GN8102B Single-ended no 100 MS/s 14 bit 8 GB 8 16 2 fast 1
GN8103B Single-ended no 25 MS/s 14 bit 8 GB 8 16 2 fast 1
protection)
protection)
Enterprise
Enterprise
Advanced
Standard
(no copy
(no copy
Viewer
Viewer
Features
True 64 bit support
Advanced Report
Basic FFT
Sensor Database
User/Definer Mode
Application packages
Custom Software Interface Cost option Cost option Cost option
STL Analysis (Short-Circuit Testing Liaison
Cost option Cost option Cost option
methods)
HV-IA Lightning, Switching and Current impulse
Cost option Cost option Cost option
analysis (IEC60060-1 and IEC61083-2)
eDrive electrical motor/inverter/generator and
Cost option Cost option
drive analysis
(1) The maximum number of mainframes Perception can control is calculated by using 25% of PC memory divided by 50 MB FIFO required
per mainframe. Minimum suggested configuration is a PC with 64 bit Windows® and 8 GB of memory.
GHS Perception
Interfacing RPC/COM API
Windows
Server Client
API API
Server Client Windows
Figure 1.49: Perception CSI examples BackEMF (left) Harmonic analysis (right)
Functions Create software extensions inside the Perception software by adding CSI user sheets,
custom automation and extended analysis functions. Basic Windows C# sheet template
included. Available for all languages that support Microsoft®.NET 4.
Available basic controls & commands Access to every Perception part: Start/Stop/Pause and Trigger, Start Manager, Acquisition
System, Hardware Settings, Displays, Meters, User Tables, Formulas, Calculations, Data
Manager, Data Sources, User variables, Notifications, Logging, Conversion Functions,
Automation Actions, Sheet Manager and more, to create a dedicated application GUI that
hides the entire Perception standard GUI.
Examples (free of charge) C# getting started example programs supplied, source code included
Note Other fiber cable lengths can be ordered from custom systems at: customsystems@hbm.com
(1) Software options are also sold in a package with multiple single seat licenses and multiple seat network license.
©Hottinger Brüel & Kjaer GmbH. All rights reserved. Hottinger Brüel & Kjaer GmbH
All details describe our products in general form only.
They are not to be understood as express warranty and do Im Tiefen See 45 ∙ 64293 Darmstadt ∙ Germany
not constitute any liability whatsoever.
Tel. +49 6151 803-0 ∙ Fax: +49 6151 803-9100
E-mail: info@hbm.com ∙ www.hbm.com