Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

CRN - 4510 - Afaehqqe - 96123135

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Company name:

Created by:
Phone:

Date: 19/08/2023
H CRN 45-10, 3*400 V, 50Hz eta
Description Value [m] [%]
General information:
Product name: CRN 45-10
A-F-A-E-HQQE
250 100
Product No: On request
EAN number: On request
Technical: 200 80

Pump speed on which pump data are 2957 rpm


based: 150 60
Rated flow: 45 m³/h
Rated head: 204.8 m 100 40
Maximum head: 255.2 m
Stages: 10 50 20
Impellers: 10
Number of reduced-diameter impellers: 0
0 0
Low NPSH: N 0 10 20 30 40 50 Q [m³/h]
Pump orientation: Vertical Pumped liquid = Water
Liquid temperature during operation = 20 °C
Shaft seal arrangement: Single
Density = 998.2 kg/m³
Code for shaft seal: HQQE P NPSH
[kW] [m]
Approvals: CE,EAC,UKCA,SEPRO
P1
Approvals for drinking water: WRAS,ACS 35 14
P2
Curve tolerance: ISO9906:2012 3B
30 12
Pump version: A
25 10
Model: B
Materials: 20 8

Base: Stainless steel 15 6


Base: EN 1.4408 10 4
Base: AISI 316
5 2
Impeller: Stainless steel
0 0
Impeller: EN 1.4401
331
266
365
251
160
200

140
45

80
190
4
x
14
1389

4 X G 1/2

18
x
8

G 1/2

Impeller: AISI 316


400
636

396

315

315
Material code: A 396

Code for rubber: E


Bearing: SIC
Support bearing: Graflon
636

Installation:
Maximum ambient temperature: 55 °C
Maximum operating pressure: 30 bar 400

Max pressure at stated temp: 30 bar / 120 °C


G 1/2 G 1/2
Max pressure at stated temp: 30 bar / -40 °C
1389

Type of connection: DIN 4 X G 1/2


8 x 18

Size of inlet connection: DN 80


160
200

Size of outlet connection: DN 80


45
140

Pressure rating for connection: PN 40 190 80


4 x 14
251 266
Flange size for motor: FF350 365 331

Connect code: F
Liquid:
Pumped liquid: Water
Liquid temperature range: -40 .. 120 °C +T +T +T

Selected liquid temperature: 20 °C


Density: 998.2 kg/m³
CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY
IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE

Electrical data: TO AMPLIFIER


RELAY

Motor standard: IEC L1 L2 L3

Motor type: SIEMENS


THERMISTORS PTC ACCORDING TO DIN 44082

Rated power - P2: 37 kW


+T +T +T
Power (P2) required by pump: 37 kW
Mains frequency: 50 Hz
Rated voltage: 3 x 380-420D/660-725Y
V TO AMPLIFIER
RELAY
L1 L2 L3
Rated current: 65/37.5 A

Printed from Grundfos Product Centre [2023.32.001] 1/4


Company name:
Created by:
Phone:

Date: 19/08/2023

Description Value
Starting current: 710-710 %
Cos phi - power factor: 0.88
Rated speed: 2955 rpm
IE efficiency: IE3 93,7%
IE Efficiency class: IE3
Motor efficiency at full load: 93.7-93.7 %
Motor efficiency at 3/4 load: 94.2-94.2 %
Motor efficiency at 1/2 load: 94.0-94.0 %
Number of poles: 2
Enclosure class (IEC 34-5): IP55
Insulation class (IEC 85): F
Built-in motor protection: PTC
Motor No: 81U15334
Controls:
Frequency converter: NONE
Others:
Terminal box position: 6
Minimum efficiency index, MEI ≥: 0.70
Net weight: 362 kg
Gross weight: 407 kg
Shipping volume: 0.808 m³
Danish VVS No.: 385917100

Printed from Grundfos Product Centre [2023.32.001] 2/4


Company name:
Created by:
Phone:

Date: 19/08/2023

On request CRN 45-10 A-F-A-E-HQQE 50 Hz

14
200

x
4
160

266
331
80
18

45
8x
G 1/2

190

251
365
396
315

4 X G 1/2
G 1/2
400

140

636 1389

Note! All units are in [mm] unless others are stated.


Disclaimer: This simplified dimensional drawing does not show all details.

Printed from Grundfos Product Centre [2023.32.001] 3/4


Company name:
Created by:
Phone:

Date: 19/08/2023

On request CRN 45-10 A-F-A-E-HQQE 50 Hz

+T +T +T

CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY


IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE
TO AMPLIFIER
RELAY
L1 L2 L3

THERMISTORS PTC ACCORDING TO DIN 44082

+T +T +T

TO AMPLIFIER
RELAY
L1 L2 L3

Note! All units are in [mm] unless others are stated.

Printed from Grundfos Product Centre [2023.32.001] 4/4