ENVPEP2309009_V1 - Product Environmental Profile - BlokSeT lean low voltage switchboard

Product Environmental Profile


BlokSeT lean low voltage switchboard

ENVPEP2309009_V1 # Internal 09/2023


ENVPEP2309009_V1 - Product Environmental Profile - BlokSeT lean low voltage switchboard

General information

Reference product BlokSeT lean low voltage switchboard

Protect people against electric shocks by direct contact and the equipment it houses against the penetration of solids and liquids
Description of the product
and against mechanical shocks.

It is an assembled enclosures with busbars for a maximum current value of up to 5000A. It is to protect persons during 20 years
against direct contact with live parts and allow monitoring, control and protection devices in a single enclosure or a cabinet having
Functional unit the following dimensions 2200 x 3300 x 600 mm. Continuous current pass through the busbars for the devices to be connected. It
can withstand mechanical impacts (IK10 - IEC62262) and the penetration of solid objects and liquids (IP54 - IEC 60529) in
accordance with IEC 61439-1 and 2 standards.

Constituent materials

Reference product mass 2220000 g including the product, its packaging and additional elements and accessories

Stainless steel - 0.3% Wood - 12.6% PC Polycarbonate - 0.2%

UP Polyester - 0.1%
Aluminium - 1.1%
PA Polyamide - 0.1%

Steel - 35%

Copper - 50.6%

Plastics 0.4%
Metals 87.0%
Others 12.6%

Substance assessment

Details of ROHS and REACH substances information are available on the Schneider-Electric Green Premium website
https://www.se.com/ww/en/work/support/green-premium/

ENVPEP2309009_V1 # Internal 09/2023


ENVPEP2309009_V1 - Product Environmental Profile - BlokSeT lean low voltage switchboard

Additional environmental information

Recyclability rate has been calculated based on REEECY'LAB tool developed by Ecosystem, for
components/materials not covered by the tool, data from the “ECO’DEEE recyclability and recoverability
End Of Life Recyclability potential: 98%
calculation method” was taken. If no data was found a conservative assumption was used (0%
recyclability).

Environmental impacts

Reference service life time 20 years

Product category Other equipments - Passive product - continuous operation

Installation elements BlokSeT lean low voltage switchboard does not require any installation operations.

load rate / rated current (In): 30 % of In


Use scenario
percentage of utilization time: 100%

Technological The Modules of Technologies such as material production, manufacturing process and transport technology used in this PEP analysis (LCA-
representativeness EIME in this case) are Similar and representative of the actual type of technologies used to make the product in production

Geographical
APAC
representativeness
[A1 - A3] [A5] [B6] [C1 - C4]
Energy model used Electricity Mix; Production mix; Low voltage; Electricity Mix; Production Electricity Mix; Production Electricity Mix; Production mix;
APAC mix; Low voltage; APAC mix; Low voltage; APAC Low voltage; APAC

Detailed results, including all the optional indicators mentioned in PCRed4, and the split of the Use Phase (B1 to B7), are available in the LCA report
and on demand in a digital format - Country Customer Care Center - http://www.schneider-electric.com/contact

Mandatory Indicators BlokSeT lean low voltage switchboard - LVESWBI_BLOKSET

Manufacturing Distribution Installation Use End of Life Benefits


Impact indicators Unit Total
[A1 - A3] [A4] [A5] [B1 - B7] [C1 - C4] [D]

Contribution to climate change kg CO2 eq 4.69E+04 7.82E+03 6.40E+02 4.27E+02 3.40E+04 4.03E+03 -6.42E+04

Contribution to climate change-fossil kg CO2 eq 4.65E+04 7.55E+03 6.40E+02 5.64E+02 3.40E+04 3.82E+03 -5.93E+04

Contribution to climate change-biogenic kg CO2 eq 3.61E+02 2.75E+02 0* 0* 1.30E+01 2.10E+02 -4.91E+03

Contribution to climate change-land use and land use change kg CO2 eq 3.82E-03 0* 0* 3.20E-04 0* 3.50E-03 0.00E+00

kg CFC-11
Contribution to ozone depletion 2.34E-03 1.46E-03 5.65E-04 1.04E-05 1.74E-04 1.22E-04 -1.76E-02
eq

Contribution to acidification mol H+ eq 5.15E+02 2.40E+02 2.78E+00 2.82E+00 2.34E+02 3.49E+01 -4.24E+03

kg (PO4)³¯
Contribution to eutrophication, freshwater 8.15E+00 1.20E-02 0* 6.84E-01 9.29E-03 7.45E+00 -8.62E-02
eq

Contribution to eutrophication marine kg N eq 3.95E+01 6.73E+00 1.28E+00 4.87E-01 2.55E+01 5.44E+00 -6.57E+01

Contribution to eutrophication, terrestrial mol N eq 4.59E+02 7.87E+01 1.38E+01 5.84E+00 2.94E+02 6.62E+01 -7.73E+02

kg COVNM
Contribution to photochemical ozone formation - human health 1.45E+02 3.70E+01 4.54E+00 1.50E+00 8.51E+01 1.74E+01 -4.85E+02
eq
Contribution to resource use, minerals and metals kg Sb eq 2.94E+00 2.72E+00 0* 1.92E-02 5.43E-04 2.10E-01 -3.49E+01

Contribution to resource use, fossils MJ 8.98E+05 1.47E+05 7.77E+03 4.72E+03 5.56E+05 1.83E+05 -1.05E+06

Contribution to water use m3 eq 1.96E+04 1.14E+04 3.25E+01 5.13E+02 1.39E+03 6.26E+03 -2.00E+05

ENVPEP2309009_V1 # Internal 09/2023


ENVPEP2309009_V1 - Product Environmental Profile - BlokSeT lean low voltage switchboard

Additional indicators for the French regulation are available as well

Inventory flows Indicators BlokSeT lean low voltage switchboard - LVESWBI_BLOKSET

Manufact. Distribution Installation Use End of Life Benefits

Inventory flows Unit Total

[A1 - A3] [A4] [A5] [B1 - B7] [C1 - C4] [D]

Contribution to use of renewable primary energy excluding


MJ 6.86E+04 6.68E+03 0* 1.63E+03 5.52E+04 5.02E+03 -1.06E+05
renewable primary energy used as raw material

Contribution to use of renewable primary energy resources


MJ 5.87E+03 5.87E+03 0* 0* 0* 0* -1.53E+03
used as raw material

Contribution to total use of renewable primary energy resources MJ 7.44E+04 1.26E+04 0* 1.63E+03 5.52E+04 5.02E+03 -1.07E+05

Contribution to use of non renewable primary energy excluding


MJ 8.98E+05 1.46E+05 7.77E+03 4.72E+03 5.56E+05 1.83E+05 -1.05E+06
non renewable primary energy used as raw material

Contribution to use of non renewable primary energy resources


MJ 2.81E+02 2.81E+02 0* 0* 0* 0* 0.00E+00
used as raw material

Contribution to total use of non-renewable primary energy


MJ 8.98E+05 1.47E+05 7.77E+03 4.72E+03 5.56E+05 1.83E+05 -1.05E+06
resources

Contribution to use of secondary material kg 0.00E+00 0* 0* 0* 0* 0* 0.00E+00

Contribution to use of renewable secondary fuels MJ 0.00E+00 0* 0* 0* 0* 0* 0.00E+00

Contribution to use of non renewable secondary fuels MJ 0.00E+00 0* 0* 0* 0* 0* 0.00E+00

Contribution to net use of freshwater m³ 4.57E+02 2.66E+02 7.56E-01 1.19E+01 3.24E+01 1.46E+02 -4.67E+03

Contribution to hazardous waste disposed kg 2.39E+05 2.36E+05 0* 0* 9.07E+02 1.88E+03 -3.19E+06

Contribution to non hazardous waste disposed kg 9.63E+03 3.81E+03 0* 2.23E+02 5.58E+03 1.72E+01 -9.55E+03

Contribution to radioactive waste disposed kg 2.64E+00 2.05E+00 1.27E-01 7.90E-03 4.42E-01 1.31E-02 -7.30E+00

Contribution to components for reuse kg 0.00E+00 0* 0* 0* 0* 0* 0.00E+00

Contribution to materials for recycling kg 1.98E+03 0* 0* 1.84E+02 0* 1.79E+03 0.00E+00

Contribution to materials for energy recovery kg 0.00E+00 0* 0* 0* 0* 0* 0.00E+00

Contribution to exported energy MJ 1.92E+02 1.80E+01 0* 1.74E+02 0* 0* 0.00E+00

Contribution to biogenic carbon content of the product kg de C 0.00E+00 0* 0* 0* 0* 0* 0.00E+00


Contribution to biogenic carbon content of the associated
kg de C 0.00E+00 0* 0* 0* 0* 0* 0.00E+00
packaging
* represents less than 0.01% of the total life cycle of the reference flow
Life cycle assessment performed with EIME version v5.9.4, database version 2022-01 in compliance with ISO14044.
Detailed results, including all the optional indicators mentioned in PCRed4, and the split of the Use Phase (B1 to B7), are available in the LCA report
and on demand in a digital format - Country Customer Care Center - http://www.schneider-electric.com/contact

ENVPEP2309009_V1 # Internal 09/2023


ENVPEP2309009_V1 - Product Environmental Profile - BlokSeT lean low voltage switchboard

Please note that the values given above are only valid within the context specified and cannot be used directly to draw up the environmental assessment of an installation.

Registration number : ENVPEP2309009_V1 Drafting rules PEP-PCR-ed4-2021 09 06


Verifier accreditation N° Supplemented by PSR-0005-ed2-2016 03 29
Information and
Date of issue 2023/09/05 www.pep-ecopassport.org
reference documents
Validity period 5 years
Independent verification of the declaration and data, in compliance with ISO 14021 : 2016
Internal X External
The PCR review was conducted by a panel of experts chaired by Julie ORGELET (Ddemain)
PEP are compliant with XP C08-100-1 :2016 or EN 50693:2019
The elements of the present PEP cannot be compared with elements from another program.
Document in compliance with ISO 14021 : 2016 « Environmental labels and declarations. Type II environmental declarations »

Schneider Electric Industries SAS


Country Customer Care Center
http://www.schneider-electric.com/contact
35, rue Joseph Monier
CS 30323
F- 92500 Rueil Malmaison Cedex
RCS Nanterre 954 503 439
Capital social 896 313 776 €

www.se.com Published by Schneider Electric


ENVPEP2309009_V1 ©2023 - Schneider Electric – All rights reserved 2023/09/05

ENVPEP2309009_V1 # Internal 09/2023

You might also like