UL 873 12th Ed 16 Nov 2007 ED 8 31 2019
UL 873 12th Ed 16 Nov 2007 ED 8 31 2019
UL 873 12th Ed 16 Nov 2007 ED 8 31 2019
STANDARD INFORMATION
This SUN establishes the continuing certification and withdrawal of UL 60730-2-13A 1st Edition / UL 873 12th
Edition and introduces UL 60730-2-13 as the superseding standard.
Superseded Standard Number: UL 60730-2-13A & UL 873
Superseded Standard Name: Automatic Electrical Controls for Household and Similar Use; Part 2: Particular
Requirements for Humidity Sensing Controls, 1st Edition Dated February 5, 2002 & Temperature-Indicating and
-Regulating Equipment, 12th Edition Dated November 16, 2007
Superseding Standard Number: UL 60730-2-13
Superseding Standard Name: Automatic Electrical Controls for Household and Similar Use; Part 2: Particular
Requirements for Humidity Sensing Controls, 2nd Edition, Dated July 1, 2014
Current Listings Not Active? – Please immediately identify any current Listing Reports or products that are no
longer active and should be removed from our records. We will do this at no charge as long as Intertek is
notified in writing prior to the review of your reports.
17 Info Endurance
17.8 Info Test of automatic action at accelerated rate
New clause added;
Page 2 of 4
For integrated and incorporated electronic controls, the tests of this clause
may be carried out under declared conditions if so requested by the
manufacturer.
H.26.8.3.101DV.1 For controls declared under item 101 of Table 7.2, the tests
are performed when the control is in the declared condition and when it is
not.
D2 Modification of H.26.9.3.101 of the Part 2 by adding the following
clause:
H.26.9.3.101DV
H.26.9.3.101DV.1 For controls declared under item 101 of Table 7.2, the tests
are performed when the control is in the declared condition and when it is
not.
D2 Modification of H.26.10.5.101 of the Part 2 by adding the following
clause:
H.26.10.5.101DV
H.26.10.5.101DV.1 For controls declared under item 101 of Table 7.2, the
tests are performed when the control is in the declared condition and when it
is not.
H.26.12 Radio-frequency electromagnetic field immunity
H.26.12.2 Immunity to conducted disturbances
Page 3 of 4
Test procedure
Addition:
H.26.12.2.2
For controls declared under requirement 101 of Table 7.2, sweeping is
performed when the control is in the declared position and when it is not.
Radiated electromagnetic fields immunity evaluation
Additional subclause:
H.26.12.3
H.26.12.3.101 For controls declared under requirement 101 of Table 7.2,
sweeping is performed when the control is in the declared condition and when
it is not.
H.26.12.4 Power frequency magnetic field immunity test
Test procedure
Addition:
H.26.12.4.3
For controls declared under requirement 101 of Table 7.2, the test shall be
performed when the control is in the declared condition and when it is not.
H.26.12.5 Evaluation of compliance
Addition:
H.26.12.5.2
See Table H.26.2.101 for compliance criteria.
Addition:
H.26.12.5.4
See Table H.26.2.101 for compliance criteria.
Annex AA Number of cycles
Minimum number of cycles for independently mounted and in-line cord
AA.2 Info
controls (applicable in Canada and the USA)
D2 Modification of this table by adding the following Note:
AA.2DV Note: In the U.S.A., these minimum number of cycles also apply for
INDEPENDENTLY MOUNTED, IN-LINE CORD, FREE-STANDING CONTROL,
INTEGRATED, and INCORPORATED HUMIDITYSENSING CONTROLS.
Manufacturing and Production Tests
Annex 13.DVE
This annex of Part 1 is applicable.
CUSTOMERS PLEASE NOTE: This Table and column “Verdict” can be used in
determining how your current or future production is or will be in compliance
with new/revised requirements.