Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
0% found this document useful (0 votes)
62 views

API 575 Questions

This document contains 10 multiple choice questions about API 575 standards for atmospheric storage tanks. The questions cover topics such as the specifications that covered riveted atmospheric storage tanks (API 12A), fluids not suitable for atmospheric tanks (liquid oxygen), types of floating roof designs (lifter type is not), purposes of breather-type roofs (to provide expansion space for vapors), and maximum design pressures of API 650 and API 620 tanks (2.5 psi and 15 psi respectively).

Uploaded by

Mohammed Youssef
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
62 views

API 575 Questions

This document contains 10 multiple choice questions about API 575 standards for atmospheric storage tanks. The questions cover topics such as the specifications that covered riveted atmospheric storage tanks (API 12A), fluids not suitable for atmospheric tanks (liquid oxygen), types of floating roof designs (lifter type is not), purposes of breather-type roofs (to provide expansion space for vapors), and maximum design pressures of API 650 and API 620 tanks (2.5 psi and 15 psi respectively).

Uploaded by

Mohammed Youssef
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 3

Q1.

API 575: construction standards


Which of the following old specifications covered
riveted atmospheric storage tanks?
 (a) API 12A
 (b) API 12B
 (c) API 12C
 (d) API 12D

Q2. API 575: use of atmospheric tanks


Which of the following fluids would not be suitable for
being held in an atmospheric tank?
 (a) Heavy oil
 (b) Gas oil (kerosene)
 (c) Water
 (d) Liquid oxygen

Q3. API 575: atmospheric storage tank roofs


What type of fixed roof does not need supporting
rafters/columns, etc.?
 (a) Double roof type
 (b) Geodesic dome type
 (c) Breather type
 (d) Pan type

Q4. API 575: atmospheric storage tank roofs


Which of these is not a floating roof design?
 (a) Pan type
 (b) Pontoon type
 (c) Double-deck type
 (d) Lifter type
Q5. API 575: atmospheric storage tank roofs
Why do some floating-roof tanks have an additional
dome roof on the top?
 (a) To keep the rain out

 (b) To decrease the vapour pressure of the stored product


 (c) To increase the vapour pressure of the stored product
 (d) Both (a) and b) above

Q6. API 575: atmospheric storage tank roofs


What kind of floating-roof seal may be filled with
foam?
 (a) A mechanical seal
 (b) A tube seal
 (c) A counterweight seal
 (d) None of the above

Q7. API 575: atmospheric storage tank roofs


What is the purpose of using a breather-type roof?
 (a) To help the floating roof move without ‘vapor-locking’
 (b) To reduce vapour pressure and avoid the need for a pressurized tank
 (c) To provide expansion space for vapours
 (d) To enable vapours to be safely vented to atmosphere

Q8. API 575: low-pressure storage tanks


Which code covers the venting of low-pressure tanks?
 (a) API 650
 (b) API 2000
 (c) API 12B
 (d) API 12D
Q9. API 575: storage tank design pressure
What is the maximum design gauge pressure of an
API 650 tank?
 (a) Atmospheric pressure
 (b) 2 1/2 psi
 (c) 103 kPa
 (d) 15 psi

Q10. API 575: storage tank design pressure


What is the maximum design gauge pressure of an
API 620 tank?
 (a) Atmospheric pressure
 (b) 2 1/2 psi
 (c) 18 kPa
 (d) 15 psi

Q1 A
Q2 D
Q3 B
Q4 D
Q5 A
Q6 B
Q7 C
Q8 B
Q9 B
Q10 D