16 Bolt Pattern Fixed Base Plate Design - For 4.6 Grade Anchor Bolts
16 Bolt Pattern Fixed Base Plate Design - For 4.6 Grade Anchor Bolts
16 Bolt Pattern Fixed Base Plate Design - For 4.6 Grade Anchor Bolts
950
175 200 200 200
Axial Force (+ve for Compression & -ve For Tension) 805 KN 1.4720
Shear Force 215 KN 0.12
Bolt Diameter 56 mm
Pitch 200 mm
Guage 200 mm b
Edge Distance 100 mm
Anchor Bolt Tension Force Calculations FIGURE - A Two Side Supported Plate
Lets assume that Neutral axis of the system is at 'K' times the ' Distance of Tension Flange from Compression Edge'.
Refer Figure B - Taking moment about the tension flange ( Being C.G. of Tension Bolt Group)
3
Tension in Bolt Group 1374.05 kN
Capacity Distance of Neutral axis from 1st bolt Row (X1)
Tension Per Anchor Bolt 242.59 kN OK 243.607646 Distance of Neutral axis from 2nd bolt Row (X2)
Shear per Anchor Bolt 13.4375 kN OK 162.405097 Ratio of Bolt forrce T2 & T1
a 200 mm
b 200 mm
a/b 1
β1 1.769
β2 1.769
ϒ1 1.183
ϒ2 1.183
ϭ1 202.40027663 N/mm2 OK FIGURE B , CONCEPTUAL STRESS DIAGRAM
ϭ2 202.40027663 N/mm2 OK
Stiffener Thk 12 mm
Weld Size 8 mm
100
200
484 1084
200
100
12 THK STIFFENER
((C38/3)*C44*C44)-(C38*C44)+(C39+(C14*10^6))
K*2 (-)K. 1
884789929.83 -2654369789.49 1460310000
884.79 -2654.37 1460.31 0
K1 0.72570003354
K2 2.27429996646
Thread
Designat Rod Dia
Dia, D Pitch, p
ion (mm)
(mm)
M16 16 16 2.00
M20 20 20 2.50
M24 24 24 3.00
M30 30 30 3.50
M32 32 32 3.50
M36 36 36 4.00
M42 42 42 4.50
M48 48 48 5.00
M52 52 52 5.00
M56 56 56 5.50
M64 64 64 6.00
500
50 100 50
Axial Force (+ve for Compression & -ve For Tension) 368 KN 0.0959
Shear Force 10 KN 0.11
b/6 550
Grade of Concrete 30 N/mm2 30.0 mm
Concrete Bearing Stress 1.452179931 N/mm2 THK PLATE
Allowable Concrete Bearing Stress 7.5 N/mm2 OK
Bolt Diameter 16 mm
Pitch 100 mm
Guage 100 mm b 100
Edge Distance 50 mm 50
Anchor Bolt Tension Force Calculations FIGURE - A Two Side Supported Plate
Lets assume that Neutral axis of the system is at 'K' times the ' Distance of Tension Flange from Compression Edge'.
Refer Figure B - Taking moment about the tension flange ( Being C.G. of Tension Bolt Group)
Shear per Anchor Bolt 1.25 kN OK 12.5338358 Ratio of Bolt forrce T2 & T1
a 100 mm
b 100 mm
a/b 1
β1 1.769
β2 1.769
ϒ1 1.183
ϒ2 1.183
ϭ1 28.54340331 N/mm2 OK FIGURE B , CONCEPTUAL STRESS DIAGRAM
ϭ2 28.54340331 N/mm2 OK
Stiffener Thk 8 mm
Weld Size 6 mm
THK STIFFENER
1.5040345
1.45218
K*2 (-)K. 1
68070934.2561 -2.04E+08 151220000
68.07 -204.21 151.22
K1 1.3311988
K2 1.6688012
Thread
Designat Rod Dia
Dia, D Pitch, p
ion (mm)
(mm)
M16 16 16 2.00
M20 20 20 2.50
M24 24 24 3.00
M30 30 30 3.50
M32 32 32 3.50
M36 36 36 4.00
M42 42 42 4.50
M48 50 48 5.00
Roark's Formula for Plate supported on Two Edges (Fixed)
N/mm2 a/b 0.125 0.25 0.375
β1 0.05 0.182 0.353
β2 0.047 0.188 0.398
ϒ1 0.312 0.572 0.671
ϒ2 0.127 0.264 0.413
8 BOLT PATTERN FIXED BASE PLATE DESIGN - FOR 4.6 GRADE ANCHOR BOLTS
350
60 120 60
Axial Force (+ve for Compression & -ve For Tension) 160 KN 1.2188
Shear Force 28 KN 0.10
b/6 380 740
Grade of Concrete 30 N/mm2 30.0 mm
Concrete Bearing Stress 6.722320776 N/mm2 THK PLATE
Allowable Concrete Bearing Stress 7.5 N/mm2 OK
Bolt Diameter 30 mm
Pitch 120 mm
Guage 120 mm b 120
Edge Distance 60 mm 60
Anchor Bolt Tension Force Calculations FIGURE - A Two Side Supported Plate
Lets assume that Neutral axis of the system is at 'K' times the ' Distance of Tension Flange from Compression Edge'.
Refer Figure B - Taking moment about the tension flange ( Being C.G. of Tension Bolt Group)
Shear per Anchor Bolt 3.5 kN OK 44.8481865 Ratio of Bolt forrce T2 & T1 0.5064343
a 120 mm
b 120 mm
a/b 1 6.7223208
β1 1.769 N/mm2
β2 1.769
ϒ1 1.183
ϒ2 1.183
ϭ1 190.2685673 N/mm2 OK FIGURE B , CONCEPTUAL STRESS DIAGRAM
ϭ2 190.2685673 N/mm2 OK
Stiffener Thk 8 mm
Weld Size 6 mm
K*2 (-)K. 1
150736839.542 -4.52E+08 243800000
150.74 -452.21 243.80
K1 0.7046311
K2 2.2953689
Thread
Designat Rod Dia
Dia, D Pitch, p
ion (mm)
(mm)
M16 16 16 2.00
M20 20 20 2.50
M24 24 24 3.00
M30 30 30 3.50
M32 32 32 3.50
M36 36 36 4.00
M42 42 42 4.50
M48 50 48 5.00
Roark's Formula for Plate supported on Two Edges (Fixed)
a/b 0.125 0.25 0.375
β1 0.05 0.182 0.353
β2 0.047 0.188 0.398
ϒ1 0.312 0.572 0.671
ϒ2 0.127 0.264 0.413
8 BOLT PATTERN FIXED BASE PLATE DESIGN - FOR 4.6 GRADE ANCHOR BOLTS
350
60 120 60
Axial Force (+ve for Compression & -ve For Tension) -139 KN -0.1871
Shear Force 6 KN 0.10
b/6 380 740
Grade of Concrete 30 N/mm2 30.0 mm
Concrete Bearing Stress 0.277261818 N/mm2 THK PLATE
Allowable Concrete Bearing Stress 7.5 N/mm2 OK
Bolt Diameter 30 mm
Pitch 120 mm
Guage 120 mm b 120
Edge Distance 60 mm 60
Anchor Bolt Tension Force Calculations FIGURE - A Two Side Supported Plate
Lets assume that Neutral axis of the system is at 'K' times the ' Distance of Tension Flange from Compression Edge'.
Refer Figure B - Taking moment about the tension flange ( Being C.G. of Tension Bolt Group)
Shear per Anchor Bolt 0.75 kN OK 44.8481865 Ratio of Bolt forrce T2 & T1 0.8929161
a 120 mm
b 120 mm
a/b 1 0.2772618
β1 1.769 N/mm2
β2 1.769
ϒ1 1.183
ϒ2 1.183
ϭ1 7.847618491 N/mm2 OK FIGURE B , CONCEPTUAL STRESS DIAGRAM
ϭ2 7.847618491 N/mm2 OK
Stiffener Thk 8 mm
Weld Size 6 mm
K*2 (-)K. 1
6217134.16119 -18651402 -16395000
6.22 -18.65 -16.40
K1 -0.710671
K2 3.7106712
Thread
Designat Rod Dia
Dia, D Pitch, p
ion (mm)
(mm)
M16 16 16 2.00
M20 20 20 2.50
M24 24 24 3.00
M30 30 30 3.50
M32 32 32 3.50
M36 36 36 4.00
M42 42 42 4.50
M48 50 48 5.00
Roark's Formula for Plate supported on Two Edges (Fixed)
a/b 0.125 0.25 0.375
β1 0.05 0.182 0.353
β2 0.047 0.188 0.398
ϒ1 0.312 0.572 0.671
ϒ2 0.127 0.264 0.413
8 BOLT PATTERN FIXED BASE PLATE DESIGN - FOR 4.6 GRADE ANCHOR BOLTS
260
60 120 60
Axial Force (+ve for Compression & -ve For Tension) 96 KN 1.2500
Shear Force 32 KN 0.08
b/6 320
Grade of Concrete 30 N/mm2 18.0 mm
Concrete Bearing Stress 6.531807293 N/mm2 THK PLATE
Allowable Concrete Bearing Stress 7.5 N/mm2 OK
Bolt Diameter 30 mm
Pitch 120 mm
Guage 120 mm b 120
Edge Distance 60 mm 60
Anchor Bolt Tension Force Calculations FIGURE - A Two Side Supported Plate
Lets assume that Neutral axis of the system is at 'K' times the ' Distance of Tension Flange from Compression Edge'.
Refer Figure B - Taking moment about the tension flange ( Being C.G. of Tension Bolt Group)
a 120 mm
b 120 mm
a/b 1
β1 1.769
β2 1.769
ϒ1 1.183
ϒ2 1.183
ϭ1 513.5452045 N/mm2 INCREASE PLATE THK FIGURE B , CONCEPTUAL STRESS DIAGRAM
ϭ2 513.5452045 N/mm2 INCREASE PLATE THK
Stiffener Thk 8 mm
Weld Size 6 mm
THK STIFFENER
0.4893546
6.531807
K*2 (-)K. 1
88762906.5744 -2.66E+08 141120000
88.76 -266.29 141.12
K1 0.6875059
K2 2.3124941
Thread
Designat Rod Dia
Dia, D Pitch, p
ion (mm)
(mm)
M16 16 16 2.00
M20 20 20 2.50
M24 24 24 3.00
M30 30 30 3.50
M32 32 32 3.50
M36 36 36 4.00
M42 42 42 4.50
M48 50 48 5.00
Roark's Formula for Plate supported on Two Edges (Fixed)
N/mm2 a/b 0.125 0.25 0.375
β1 0.05 0.182 0.353
β2 0.047 0.188 0.398
ϒ1 0.312 0.572 0.671
ϒ2 0.127 0.264 0.413