SGS - ROHS Report For LF SOLDER NEW-1
SGS - ROHS Report For LF SOLDER NEW-1
SGS - ROHS Report For LF SOLDER NEW-1
S T METAL INDUSTRIES
A-2/20,SITE-4, SAHIBABAD INDUSTRIAL AREA
GHAZIABAD, UP-201012
CONCLUSION: Based on the performed tests on submitted sample(s),the results of Cadmium, Lead, Mercury,
Hexavalent chromium, Polybrominated biphenyls (PBBs),Polybrominated diphenyl ethers
(PBDEs), Comply with the limits as set by RoHS Directive (EU) 2015/863 amending Annex II to
Directive 2011/65/EU.
Authorized Signatory
Kapil Patil
Manager -RSL-HL/EE
Remarks:
(1) 1mg/kg=0.0001%
(2) MDL = Method Detection Limit
(3) ND = Not Detected (<MDL)
(4) - = not regulated
Test Method:
Test result:
Notes:
(1) The maximum permissible limit is quoted from RoHS Directive (EU) 2015/863.
(3) ▼
= a. The sample is positive for Cr(VI) if the Cr(VI) concentration is greater than 0.13 μg/cm2. The sample coating
is considered to contain Cr(VI).
b. The sample is negative for Cr(VI) if Cr(VI) is ND (concentration less than 0.10 μg/cm2). The coating is
considered a non-Cr(VI) based coating.
c. The result between 0.10 μg/cm2 and 0.13 μg/cm2 is considered to be inconclusive - unavoidable coating
variations may influence the determination.
Information on storage conditions and production date of the tested sample is unavailable and thus Cr(VI) results
represent status of the sample at the time of testing.
As requested by client, the conclusion of Specimen X was drawn without considering the coating variation of the
sample.
Process Flow for analysis of metal contents in plastics, metals and electronic components sample
Sample preparation,
0.25 – 0.30 g
< 2×2×2 mm3
Cool down
Cool down
Add 0.25 g
orthoboric acid
Filtration
25 ml final volume
ICP-OES/MS
Process Flow for analysis of Hexachromium contents in plastics, metals and electronic components sample
Sample
Add NMP solvent for dissolution Added mixture of Toluene and Boiling water
followed by addition of digestion digestion solution extraction
soltuion
Data
Process Flow for analysis of Flame Retardants in plastics, metals and electronic components sample
Sample
Sample Pretreatment
Soxhlet extraction
IEC 62321-6:2015
Concentrate/Dilute
Extracted solution
Filter if necessary