Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Uk-Aquplst0323-01 Cta

Download as pdf or txt
Download as pdf or txt
You are on page 1of 32

Aquarea A2W

Heat Pump Price List


2023 / 2024
Panasonic environmental vision 2050
To achieve “a better life” and “a sustainable global environment,” Panasonic will work towards creation
and more efficient utilisation of energy which exceeds the amount of energy used, aiming for a society
with clean energy and a more comfortable lifestyle.

Energy used < Energy created


One initiative in the Panasonic environmental vision 2050 is offering products with greater energy
efficiency. In 2018, we celebrated the 60th anniversary of our Heating & Cooling Solutions business.
Our expertise gained over the years has helped us launch a range of products that contribute to a
more carbon-free society.

Current status of energy used and energy created Working to realise environmental vision 2050

10
Energy used.
Energy
Improve energy-saving performances of products.
Energy used by Panasonic Innovate manufacturing processes.
business activities and
products.
used
Energy

1
Energy created.
Clean energy created and / or Energy Expand energy-creation/storage business.
Increase opportunities for using clean energy.
made available by Panasonic
products, etc. created
2010 2020 2030 2040 2050
Vitalise the future with air. Bringing nature’s balance indoors.
These are times of exceptional challenge. nanoe™ X, technology with the benefits of hydroxyl radicals.
If the world is to move forward confidently, it must overcome the In today’s health-conscious world, we care about taking exercise, we
serious threats of the new global pandemics and the degrading of the care about what we eat and what we touch, we also care about what
environment. It must find ways large and small to reduce the we breathe – and technology exists to bring good outdoor air, indoors.
stresses that affect people’s health and the stability of their
communities.

100% Panasonic, the DNA of Japanese craftsmanship A globally trusted air conditioning brand.
Applying advanced technologies that truly make life better, we live by Panasonic – leading the way in Heating and Cooling.
an unparalleled commitment to product quality. With more than 50 years of experience, selling to more than 120
Panasonic is building on the Japanese tradition of uncompromising countries around the world, Panasonic is one of the leaders in the
quality control worldwide, developing and manufacturing fine heating and cooling sector.
products and delivering them to customers everywhere. With a diverse network of production and R&D facilities, Panasonic
delivers innovative products incorporating cutting-edge technologies
that set the standard for air conditioners worldwide.

Quality Management
Quality System
Management
Certificate EnvironmentalEnvironmental
System Certificate Management System
Management
Certificate
System Certificate
ISO 9001: 2015 ISO 9001: 2015 ISO 14001: 2015 ISO 14001: 2015
Panasonic AppliancesPanasonic
Air-Conditioning
Appliances Air-Conditioning Panasonic AppliancesPanasonic
Air-Conditioning
Appliances Air-Conditioning
Malaysia. Sdn.Bhd. Malaysia. Sdn.Bhd. Malaysia Sdn.Bhd. Malaysia Sdn.Bhd.
Cert. No.: QMS 00413Cert. No.: QMS 00413 Cert. No.: EMS 00109Cert. No.: EMS 00109

GB/T 19001-2016/ISO
GB/T 9001:
19001-2016/ISO
2015 9001: 2015 GB/T 24001-2016/ISO
GB/T 14001:
24001-2016/ISO
2015 14001: 2015
Panasonic AppliancesPanasonic
Air-Conditioning
Appliances Air-Conditioning Panasonic AppliancesPanasonic
Air-Conditioning
Appliances Air-Conditioning
(GuangZhou) Co., Ltd.(GuangZhou) Co., Ltd. (GuangZhou) Co., Ltd.(GuangZhou) Co., Ltd.
Registration Number: Registration
01218Q30835R8L
Number: 01218Q30835R8L Registration Number: Registration
02118E10944R7M
Number: 02118E10944R7M
PRO Club. The professional website of Panasonic
Panasonic has an impressive range of support services for designers, specifiers, engineers and
distributors working in the heating and cooling markets.

Panasonic PRO Club (www.panasonicproclub.com) is the online tool which makes your life easier! You
just have to register and a lot of functionalities are freely available to you, where ever you are, from your
computer or smartphone!

· Print catalogues with your logo and contact details · Download Revit and CAD files and specification texts
· Access to the extensive library of professional design, · Know what to do with error codes (error code search by
selection and calculation tools (Aquarea Designer, VRF error code or unit ref.)
software, chiller selector, etc.) · PRO Academy: register for training
· Get documents of conformity and all other documents · Download product images in high resolutions,
you may need advertisements, deco guidelines
· Download all the service manuals, end user manuals and · Get to know special offers and promotions
installation manuals · Find out about the latest news first
· Download energy labels in PDF format using the energy
label generators

Easy download Panasonic service Customise leaflets with your logo and contact Energy label generator. Download Energy Error Code on your smartphone and your PC:
documentation and brochures details. Save and print the PDF labels of any device in PDF format Search by error code or model reference.
Online version + downloadable version for
offline use

Panasonic PRO Club is fully compatible with tablet computer and smartphone.
Visit www.panasonicproclub.com or connect simply with your smartphone to the PRO Club
using this QR.

4
Panasonic provides bespoke software and tools helping system designers, installers and dealers to very
quickly select, design and size systems or create wiring or hydraulic diagrams at the push of a button.

Aquarea Designer - online tool Domestic AirCon Quick Selector


With Panasonic’s online tool, projects can be This user-friendly online tool for our domestic range
developed simply and easily. The newly AQUAREA DESIGNER allows to choose the best split or multi-split system for
developed tool is optimised to help HVAC each project needs and get the specifications of that
professionals easily identify the most appropriate Aquarea particular application.
air to water heat pump for a particular application.

New commercial AC design software Open BIM


The commercial AC design software will be rebuilt with an Design, analysis and BIM modeling of Panasonic
improved user experience. The new software runs in the VRF and Air to Water heat pump systems.
cloud and is always up to date with the latest products. An Generates documents, 3D model, schematics
intuitive interface supports the most complicated designs, and drawings. This application is integrated into the Open
allows online sharing and project collaboration with BIM workflow via the BIMserver.center platform.
multilingual support.
* Available from Spring 2023.

Chiller configurator Refrigeration designer


This online software solution offers a complete tool to This simple design tool supports engineers,
allow the user to accurately calculate the performance at installers, and technicians to make a quick
specified conditions, select and configure our range of calculation for commercial refrigeration systems.
commercial chillers, heat pumps and fan coils. It also
provides a comprehensive report to share with customers
and clients alike.

5
6
AQUAREA

Welcome to Aquarea air to water heat pumps


From 3 kW to 16 kW, Panasonic’s Aquarea air to water heat pumps range is one of the widest on the
market, offering solutions for most properties, whatever their size and heating and cooling demands.
Suitable for new build and refurbishment projects, the solutions are cost-effective with minimised
environmental impact.

New Aquarea L Generation, with natural


refrigerant R290. R290
NATURAL

· Ideal for retrofit applications REFRIGERANT

·H  ydro connection between the indoor and outdoor


unit
· Water outlet temperatures of up to 75 °C down to -10 °C
·D  omestic hot water up to 65 °C without heater
·N  ew indoor unit design plus a new outdoor unit in
anthracite grey
·W  i-Fi adapter included

New Aquarea K Generation.


· Ideal solution for new build applications
·W  ater outlet temperatures of up to 60 °C down to
-10 °C
·A  vailable in High Performance and T‑CAP ranges
·N  ew indoor unit design plus a renewed outdoor unit
in anthracite grey
·S  eamless connectivity integration
·R  emote controller designed in harmony with the
whole system

T-CAP Monobloc in R32.


Offering the maximum comfort and flexibility, the
Aquarea T‑CAP Monobloc J Generation in R32 can
maintain the heat pump output capacity until -20 °C
outdoor temperature or reach up to 65 °C water
outlet.

Aquarea Smart and Service Cloud.


A powerful and intuitive service for remotely
controlling the full range of heating and hot water
functions, including monitoring energy consumption.
Aquarea Service Cloud allows installers to take care of
their customers’ heating systems remotely.

7
Aquarea Heat
Pump line-up

All in One System.


The system, consisting of separate
indoor and outdoor units, connects to
the heating and/or hot water system.
The indoor unit includes a stainless
steel DHW tank (185 L).

Bi‑bloc System. Monobloc System.


The system, consisting of separate indoor and outdoor units, This only has an outdoor unit. The installation doesn’t require a
connects to the heating and/or hot water system (tank not included). refrigerated connection and is only connected to the heating and/or
hot water (tank not included).

Aquarea Smart Cloud for the users. Aquarea Service Cloud for installers.
The most advanced heating control for today and The Aquarea Service Cloud allows installers to
for the future. take care of their customers’ heating systems
Aquarea can be connected to the remotely.
Cloud*, enabling a powerful and It saves time and money and shortens the response time,
intuitive service for remotely thus increasing the customers’ satisfaction.
controlling the full range of heating
and hot water functions, including
monitoring energy consumption.
* Requires Wi-Fi adapter CZ-TAW1B.

8
AQUAREA INDEX AQUAREA

Panasonic Aquarea offers you solutions, helping to make the home more efficient and the installation
cheaper and easier.

Aquarea High Performance Aquarea T‑CAP


For new installations and low consumption homes. For extremely low temperatures, refurbishment and
Outstanding efficiency and energy savings with minimised innovation.
CO2 emissions and minimum space. Improved Ideal to ensure that the heating capacity is maintained
performance with COPs up to 5.33 for J and K Generation even at very low temperatures. This line-up is able to
3 kW. maintain the heat pump output capacity until -20 °C1)
Now also available with natural refrigerant R290. outdoor temperature without the help of an electrical
booster heater.
1) At 35 °C flow temperature.

Aquarea High Performance Aquarea T‑CAP

Heating - Cooling - DHW Heating - Cooling - DHW

Connectable to

Radiators - Fan coil - Underfloor heating - DHW Radiators - Fan coil - Underfloor heating - DHW

Application

New buildings and retrofit Extreme cold ambient and retrofit

Energy efficiency (Heating 35 °C / 55 °C 1))


A+++ A++ A+++ A++

Control and connectivity

Smart Grid Contact 2)


Smart Grid Contact 2)
Wireless LAN Ready
Wireless LAN Ready
(included in L generation)

Aquarea High Performance Aquarea T‑CAP

Generation J K L H J K

Minimum outdoor
-20 °C -25 °C -25 °C -28 °C -20 °C 3) -28 °C
temperature
Maximum supply
60 °C 60 °C 75 °C 4) 60 °C 5) 65 °C 6) 65 °C 6)
temperature for heating

Refrigerant R32 R32 R290 R410A R32 R32

Type Monobloc Split Hydro‑Split Split Monobloc Split

Single phase capacities 5, 7, 9 kW 3, 5, 7, 9 kW 5, 7, 9 kW 9, 12 kW 9, 12 kW 9, 12 kW

Three phase capacities — — — 16 kW 9, 12, 16 kW 9, 12 kW


All data in this chart is applicable in most of models in each line up, check product specs to confirm. 1) Scale from A+++ to D. 2) J and H Generations with CZ-NS4P. K and L Generations with CZ-NS5P. 3) 9, 12
and 16 kW. 4) DHW maximum temperature with heater. 5) In case of outdoor temperature over -10 °C. 6) It is possible to set temperature by 65 °C on remote controller. Normally, outlet water temperature is
60 °C or lower. In case of ΔT setting with remote controller is 15 °C and the outdoor ambient temperature is 5 to 20 °C, outlet water temperature 65 °C is possible.

9
3 kW 5 kW 7 kW

Hydro‑Split
All in One
1ph

P. 14 R290 R290
NATURAL NATURAL
REFRIGERANT REFRIGERANT

NEW NEW
WH-ADC0509L3E5UK 1) WH-ADC0509L3E5UK 1)
WH-WDG05LE5 WH-WDG07LE5

Hydro‑Split
Bi‑bloc
1ph

P. 14 R290 R290
NATURAL NATURAL
REFRIGERANT REFRIGERANT

NEW NEW
WH-SDC0509L3E5 WH-SDC0509L3E5
WH-WDG05LE5 WH-WDG07LE5
Aquarea High Performance

Refrigerant
Split
All in One
1ph
NEW NEW NEW
WH-ADC0309K3E5UK 1) WH-ADC0309K3E5UK 1) WH-ADC0309K3E5UK 1)
P. 15 WH-UDZ03KE5 WH-UDZ05KE5 WH-UDZ07KE5

WH-ADC0309J3E5UK WH-ADC0309J3E5UK WH-ADC0309J3E5UK


WH-UD03JE5 WH-UD05JE5 WH-UD07JE5

Refrigerant
Split
Bi‑bloc
1ph

P. 15
NEW NEW NEW
WH-SDC0309K3E5 1) 2) WH-SDC0309K3E5 1) 2) WH-SDC0309K3E5 1) 2)
WH-UDZ03KE5 2) WH-UDZ05KE5 2) WH-UDZ07KE5 2)

Monobloc
1ph

P. 16,

WH-MDC05J3E5 WH-MDC07J3E5

Refrigerant
Split
All in One
1ph

P. 16

Refrigerant
Split
Aquarea T‑CAP

Bi‑bloc
1ph / 3ph

P. 18

Monobloc
1ph / 3ph

P. 19

Models with R290 refrigerant. Models with R32 refrigerant.


1) Also available with 6 kW back-up heater. 2) Available Autumn 23. 3) Also available with 9 kW back-up heater.
WH-__E5 1ph // WH-__E8 3ph.

10
AQUAREA INDEX AQUAREA

9 kW 12 kW 16 kW

R290
NATURAL
REFRIGERANT

NEW
WH-ADC0509L3E5UK 1)
WH-WDG09LE5

R290
NATURAL
REFRIGERANT

NEW
WH-SDC0509L3E5
WH-WDG09LE5

NEW
WH-ADC0309K3E5UK 1)
WH-UDZ09KE5

NEW
WH-SDC0309K3E5 1) 2)
WH-UDZ09KE5 2)

WH-MDC09J3E5 WH-MDC12H6E5 WH-MDC16H6E5

NEW NEW
WH-ADC0912K6E5UK WH-ADC0912K6E5UK
WH-UXZ09KE5 WH-UXZ12KE5

NEW NEW
WH-SXC09K3E5 1) 2) WH-SXC12K6E5 2)
WH-UXZ09KE5 2) WH-UXZ12KE5 2)
WH-SXC09K3E8 2) 3) WH-SXC12K9E8 2)
WH-UXZ09KE8 2) WH-UXZ12KE8 2)

WH-SXC09H3E5 WH-SXC12H6E5 WH-SXC16H9E8


WH-UX09HE5 WH-UX12HE5 WH-UX16HE8

WH-MXC09J3E5 WH-MXC12J6E5
WH-MXC09J3E8 WH-MXC12J9E8 WH-MXC16J9E8

11
Aquarea components
Panasonic Aquarea A2W heat pumps come with a high level of components as standard that is required
for your system to operate, no need to build a unit each time you order, this provides a true price of the
unit rather than having to build it each time to find out, no hidden costs.
For a full list items included with each unit along with performance data, see the list below:

Performance figures

2 Additional volume required on open circuit

Sound power level dB (EN12102 full power -


Eco-design average climate 55 °C (SCOP)
Eco-design average climate 350c (SCOP)
Eco-design average climate 35 °C ηs (%)

Eco-design average climate 550c ηs (%)

Sound power level dB (quiet mode 3)


Maximum flow temperature (00c)

kW output (A 3 / W 35)

Kw output (A 3 / W 45)

Kw output (A 3 / W 55)
Mcs SCOP (A 3 / W 45)

Mcs SCOP (A 3 / W 55)


Single or three phase

Mcs scop (A 3 / W 35)


Generation version
Outdoor unit (WH-)

Indoor unit (WH-)

for defrost (l)


Refrigerant

A 7 / W 55)
Type

Monobloc MDC05J3E5 — J R32 Single Zero 60 203 5,15 143 3,66 5,10 5,00 4,90 4,13 4,89 3,54 60 56
Monobloc MDC07J3E5 — J R32 Single Zero 60 204 5,17 146 3,71 6,96 5,03 6,58 3,97 6,35 3,61 61 58
Monobloc MDC09J3E5 — J R32 Single Zero 60 205 5,19 144 3,68 7,39 5,07 7,09 4,07 7,01 3,58 65 59
Monobloc MXC09J3E5 — J R32 Single Zero 65 208 5,26 147 3,74 9,00 5,09 9,00 4,23 9,00 3,60 69 56
Monobloc MXC09J3E8 — J R32 Three Zero 65 208 5,26 147 3,74 9,00 5,09 9,00 4,23 9,00 3,60 69 56
Monobloc MXC12J6E5 — J R32 Single Zero 65 206 5,23 148 3,77 12,01 5,14 12,07 4,24 12,10 3,56 72 55
Monobloc MXC12J9E8 — J R32 Three Zero 65 206 5,23 148 3,77 12,01 5,14 12,07 4,24 12,10 3,56 72 55
Monobloc MXC16J9E8 — J R32 Three Zero 65 173 4,40 135 3,45 16,00 4,22 16,00 3,77 16,05 3,32 72 —
Monobloc WDG05LE5 SDC0509L3E5 L R290 Single Zero 75 202 1) 5.12 1) 142 1) 3.63 1) TBC TBC TBC TBC TBC TBC TBC TBC
Monobloc WDG07LE5 SDC0509L3E5 L R290 Single Zero 75 193 1) 4.90 1) 130 1) 3.32 1) TBC TBC TBC TBC TBC TBC TBC TBC
Monobloc WDG09LE5 SDC0509L3E5 L R290 Single Zero 75 193 1) 4.90 1) 130 1) 3.32 1) TBC TBC TBC TBC TBC TBC TBC TBC
Monobloc WXG09LE5 SXC0916L3E5 L R290 Single Zero 75 TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC
Monobloc WXG12LE5 SXC0916L6E5 L R290 Single Zero 75 TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC
Monobloc WXG16LE8 SXC0916L9E8 L R290 Three Zero 75 TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC

Bi-Bloc UX09HE5 SXC09H3E5 H R410A Single Zero 60 195 4,96 135 3,45 9,00 4,84 9,00 3,90 9,00 TBC 64 —
Bi-Bloc UX09HE8 SXC09H3E8 H R410A Three Zero 60 195 4,96 135 3,45 9,00 4,84 9,00 3,90 9,00 TBC 64 —
Bi-Bloc UX12HE5 SXC12H6E5 H R410A Single Zero 60 182 4,62 126 3,21 12,00 4,50 12,08 3,83 12,12 TBC 66 —
Bi-Bloc UX12HE8 SXC12H9E8 H R410A Three Zero 60 182 4,62 126 3,21 12,00 4,50 12,08 3,83 12,12 TBC 66 —
Bi-Bloc UX16HE8 SXC16H9E8 H R410A Three Zero 60 174 4,42 124 3,16 16,00 4,33 16,00 3,59 16,05 TBC 68 —
Refrigerant Split

Bi-Bloc UDZ03KE5 SDC0309K3E5 K R32 Single Zero 60 200 1) 5.07 1) 136 1) 3.47 1) TBC TBC TBC TBC TBC TBC TBC TBC
Bi-Bloc UDZ05KE5 SDC0309K3E5 K R32 Single Zero 60 202 1) 5.12 1) 142 1) 3.63 1) TBC TBC TBC TBC TBC TBC TBC TBC
Bi-Bloc UDZ07KE5 SDC0309K3E5 K R32 Single Zero 60 193 1) 4.90 1) 142 1) 3.62 1) TBC TBC TBC TBC TBC TBC TBC TBC
Bi-Bloc UDZ09KE5 SDC0309K3E5 K R32 Single Zero 60 175 1)
4.44 1)
133 1)
3.41 1)
TBC TBC TBC TBC TBC TBC TBC TBC
Bi-Bloc UXZ09KE5 SDC0916K3E5 K R32 Single Zero 60 TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC
Bi-Bloc UXZ09KE8 SDC0916K3E8 K R32 Three Zero 60 TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC
Bi-Bloc UXZ12KE5 SDC0916K6E5 K R32 Single Zero 60 TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC
Bi-Bloc UXZ12KE8 SDC0916K9E8 K R32 Three Zero 60 TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC
Bi-Bloc UXZ16KE8 SDC0916K9E8 K R32 Three Zero 60 TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC

All in One WDG05LE5 ADC0509L3E5UK L R290 Single Zero 75 202 1) 5.12 1) 142 1) 3.63 1) TBC TBC TBC TBC TBC TBC TBC TBC
Hydro‑Split

All in One WDG07LE5 ADC0509L3E5UK L R290 Single Zero 75 193 1) 4.90 1) 130 1) 3.32 1) TBC TBC TBC TBC TBC TBC TBC TBC
All in One WDG09LE5 ADC0509L3E5UK L R290 Single Zero 75 193 1) 4.90 1) 130 1) 3.32 1) TBC TBC TBC TBC TBC TBC TBC TBC
All in One UDZ03KE5 ADC0309K3E5UK K R32 Single Zero 60 200 1)
5.07 1)
136 1)
3.47 1)
TBC TBC TBC TBC TBC TBC TBC TBC
Refrigerant Split

All in One UDZ05KE5 ADC0309K3E5UK K R32 Single Zero 60 202 1) 5.12 1) 142 1) 3.63 1) TBC TBC TBC TBC TBC TBC TBC TBC
All in One UDZ07KE5 ADC0309K3E5UK K R32 Single Zero 60 193 1) 4.90 1) 142 1) 3.62 1) TBC TBC TBC TBC TBC TBC TBC TBC
All in One UDZ09KE5 ADC0309K3E5UK K R32 Single Zero 60 175 1) 4.44 1) 133 1) 3.41 1) TBC TBC TBC TBC TBC TBC TBC TBC
All in One UXZ09KE5 ADC0912K6E5UK K R32 Single Zero 60 TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC
All in One UXZ12KE5 ADC0912K6E5UK K R32 Single Zero 60 TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC TBC

1) Preliminary data. 2) Reduced volume may require back up heater operation to support defrost cycle.

12
AQUAREA INDEX AQUAREA

Standard items included in unit Optional items that can be added to the unit

H Generation models (PAW-A2W-MGTFILTER)

(CZ-NS4P)* K and L Generations (CZ-NS5P)**


Aquarea Smart Cloud for remote control and

Aquarea Smart Cloud for remote control and


3 Way valve kit for inside the hydrokit (CZ-

PCB for advanced functions J Generation


Optional magnet for the water filter in

Buffer tank sensor (PAW-A2W-TSBU)


Zone water sensor (PAW-A2W-TSHC)
Anti-freeze valve (PAW-A2W-AFVLV)

Zone room sensor (PAW-A2W-TSRT)


10 m extension cable for CZ-TAW1B
Floor mounting rail on outdoor unit
Heating expansion vessel (l)

3 Way valve for DHW tanks


“A” rated circulation pump
maintenance (CZ-TAW1B)

maintenance (CZ-TAW1B)

Outdoor ambient sensor


Magnetic particle filter

Electronic flow sensor

Water pressure gauge

Pressure relief valve


Backup heater (kW)

(PAW-3WYVLV-HW)

(PAW-A2W-TSOD)
NV1)* (CZ-NV2)**

(CZ-TAW1-CBL)
Air purge valve
Inline filter

Yes Yes Yes Yes (6) Yes Yes (3) Yes Yes Yes Yes Yes N/A Yes Yes N/A Yes* Yes Yes Yes Yes Yes Yes
Yes Yes Yes Yes (6) Yes Yes (3) Yes Yes Yes Yes Yes N/A Yes Yes N/A Yes* Yes Yes Yes Yes Yes Yes
Yes Yes Yes Yes (6) Yes Yes (3) Yes Yes Yes Yes Yes N/A Yes Yes N/A Yes* N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes (10) Yes Yes (3) Yes Yes Yes Yes Yes N/A Yes Yes N/A Yes* N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes (10) Yes Yes (3) Yes Yes Yes Yes Yes N/A Yes Yes N/A Yes* N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes (10) Yes Yes (6) Yes Yes Yes Yes Yes N/A Yes Yes N/A Yes* N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes (10) Yes Yes (6) Yes Yes Yes Yes Yes N/A Yes Yes N/A Yes* N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes (10) Yes Yes (9) Yes Yes Yes Yes Yes N/A Yes Yes N/A Yes* N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes (3) Yes Yes No Yes Yes N/A Yes Yes Yes** Yes** N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes (3) Yes Yes No Yes Yes N/A Yes Yes Yes** Yes** N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes (3) Yes Yes No Yes Yes N/A Yes Yes Yes** Yes** N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes (3) Yes Yes No Yes Yes N/A Yes Yes Yes** Yes** N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes (6) Yes Yes No Yes Yes N/A Yes Yes Yes** Yes** N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes (9) Yes Yes No Yes Yes N/A Yes Yes Yes** Yes** N/A Yes Yes Yes Yes Yes

Yes Yes No Yes (10) Yes Yes (3) Yes Yes No Yes Yes Yes N/A Yes Yes Yes N/A Yes Yes Yes Yes Yes
Yes Yes No Yes (10) Yes Yes (3) Yes Yes No Yes Yes Yes N/A Yes Yes Yes N/A Yes Yes Yes Yes Yes
Yes Yes No Yes (10) Yes Yes (6) Yes Yes No Yes Yes Yes N/A Yes Yes Yes N/A Yes Yes Yes Yes Yes
Yes Yes No Yes (10) Yes Yes (6) Yes Yes No Yes Yes Yes N/A Yes Yes Yes N/A Yes Yes Yes Yes Yes
Yes Yes No Yes (10) Yes Yes (9) Yes Yes No Yes Yes Yes N/A Yes Yes Yes N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes (3) Yes Yes No Yes Yes N/A N/A Yes Yes* Yes N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes (3) Yes Yes No Yes Yes N/A N/A Yes Yes* Yes N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes (3) Yes Yes No Yes Yes N/A N/A Yes Yes* Yes N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes (3) Yes Yes No Yes Yes N/A N/A Yes Yes* Yes N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes (3) Yes Yes No Yes Yes N/A N/A Yes Yes* Yes** N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes (3) Yes Yes No Yes Yes N/A N/A Yes Yes* Yes** N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes (6) Yes Yes No Yes Yes N/A N/A Yes Yes* Yes** N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes (9) Yes Yes No Yes Yes N/A N/A Yes Yes* Yes** N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes (9) Yes Yes No Yes Yes N/A N/A Yes Yes* Yes** N/A Yes Yes Yes Yes Yes

Yes Yes Yes Yes Yes Yes (3) Yes Yes No Yes Yes N/A Yes N/A N/A Yes** N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes (3) Yes Yes No Yes Yes N/A Yes N/A N/A Yes** N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes (3) Yes Yes No Yes Yes N/A Yes N/A N/A Yes** N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes (3) Yes Yes No Yes Yes N/A N/A N/A N/A Yes N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes (3) Yes Yes No Yes Yes N/A N/A N/A N/A Yes N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes (3) Yes Yes No Yes Yes N/A N/A N/A N/A Yes N/A Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes (3) Yes Yes No Yes Yes N/A N/A N/A N/A Yes N/A Yes Yes Yes Yes Yes
Yes Yes No Yes Yes Yes (6) Yes Yes No Yes Yes Yes N/A N/A N/A Yes N/A Yes Yes Yes Yes Yes
Yes Yes No Yes Yes Yes (6) Yes Yes No Yes Yes Yes N/A N/A N/A Yes N/A Yes Yes Yes Yes Yes

13
Aquarea High Performance Hydro‑Split
NEW Aquarea High Performance Hydro‑Split All in One L Generation Single
phase. Heating and Cooling · R290 R290 New 2023
NATURAL
REFRIGERANT

Wi-Fi adapter included.


Indoor unit (H x W x D): 1 642 x 599 x 602 mm.
Operation range down to -25 °C in heating.
Kit Indoor unit Outdoor unit RRP
Heating capacity / Cooling Energy class Weight Dimension Weight
COP capacity / EER Heat / Cool
A +7 °C, A +7 °C, A 35 °C, W 35 °C / DHW HxWxD
W 35 °C W 55 °C W 18 °C W 55 °C

kW / COP kW / COP kW / EER A+++ to D A+ to F kg mm kg £


KIT-ADC05L3E5UK 5.00 / 5.05 5.00 / 3.07 5.00 / 5.00 A+++ / A++ A+ WH-ADC0509L3E5UK 93 WH-WDG05LE5 996 x 980 x 430 98 7,150
1ph KIT-ADC07L3E5UK 7.00 / 4.93 7.00 / 2.98 7.00 / 4.73 A+++ / A++ A+ WH-ADC0509L3E5UK 93 WH-WDG07LE5 996 x 980 x 430 98 7,266
KIT-ADC09L3E5UK 9.00 / 4.55 8.90 / 3.03 9.00 / 4.19 A+++ / A++ A+ WH-ADC0509L3E5UK 93 WH-WDG09LE5 996 x 980 x 430 97 7,534

Piping information Electrical information (power supply to indoor)


Kit kW 5.0 7.0 9.0 Single phase
Water pipe connector (in / out) Inch 1/1 1/1 1/1 Kit kW 5.0 7.0 9.0
Pipe length range standard / maximum m 5 / 30 5 / 30 5 / 30 Electric backup heater kW 3.00 3.00 3.00
Elevation difference (in / out) m 10 10 10 Recommended RCD, supply 1 / 2 A 25 / 16 25 / 16 25 / 16
Recommended minimum cable
mm² 3x2.5 / 3x1.5 3x2.5 / 3x1.5 3x2.5 / 3x1.5
size, supply 1 / 2 1)

1) Check local regulations.* EER and COP calculation is based in accordance to EN14511. ** This product is designed to comply with the European Water Quality Directive 98/83/EC amended by 2015/1787/EU.
The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic
water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility.

NEW Aquarea High Performance Hydro‑Split Bi‑bloc L Generation Single


phase. Heating and Cooling · R290 R290 New 2023
NATURAL
REFRIGERANT

Wi-Fi adapter included.


Indoor unit (H x W x D): 892 x 500 x 348 mm.
Operation range down to -25 °C in heating. Tentative data
Kit Indoor unit Outdoor unit RRP
Heating capacity / Cooling Energy class Weight Dimension Weight
COP capacity / EER
A +7 °C, A +7 °C, A 35 °C, W Heat / Cool HxWxD
W 35 °C W 55 °C 18 °C (W 35 °C / W 55 °C)

kW / COP kW / COP kW / EER A+++ to D kg mm kg £


KIT-WC05L3E5 5.00 / 5.05 5.00 / 3.07 5.00 / 3.23 A+++ / A++ WH-SDC0509L3E5 — WH-WDG05LE5 996 x 980 x 430 98 4,069
1ph KIT-WC07L3E5 7.00 / 4.93 7.00 / 2.98 7.00 / 3.03 A+++ / A++ WH-SDC0509L3E5 — WH-WDG07LE5 996 x 980 x 430 98 4,185
KIT-WC09L3E5 9.00 / 4.55 8.90 / 3.03 8.20 / 2.82 A+++ / A++ WH-SDC0509L3E5 — WH-WDG09LE5 996 x 980 x 430 97 4,453

Piping information Electrical information (power supply to indoor)


Kit kW 5.0 7.0 9.0 Single phase
Water pipe connector (in / out) Inch 1/1 1/1 1/1 Kit kW 5.0 7.0 9.0
Pipe length range standard / maximum m 5 / 30 5 / 30 5 / 30 Electric backup heater kW 3.00 3.00 3.00
Elevation difference (in / out) m 10 10 10 Recommended fuse A 25 / 16 25 / 16 25 / 16
Recommended minimum
mm² 3x2.5 / 3x1.5 3x2.5 / 3x1.5 3x2.5 / 3x1.5
cable size, supply 1 / 2 1)

1) Check local regulations.* EER and COP calculation is based in accordance to EN14511. ** This product is designed to comply with the European Water Quality Directive 98/83/EC amended by 2015/1787/EU.
The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic
water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility. *** Tentative data.

14
AQUAREA INDEX AQUAREA

Aquarea High Performance


NEW Aquarea High Performance Refrigerant Split All in One
K Generation Single phase. Heating and Cooling · R32 New 2023
Wi-Fi adapter included.
Indoor unit (H x W x D): 1 642 x 599 x 602 mm.
Operation range down to -25 °C 1) in heating.
Kit Indoor unit Outdoor unit RRP
Heating capacity / Cooling Energy class Weight Dimension Weight
COP capacity / EER Heat / Cool
A +7 °C, A +7 °C, A 35 °C, W 35 °C / DHW HxWxD
W 35 °C W 55 °C W 18 °C W 55 °C

kW / COP kW / COP kW / EER A+++ to D A+ to F kg mm kg £


KIT-ADC03K3E5UK 3.20 / 5.33 — / — —/— A+++ / A++ A+ WH-ADC0309K3E5UK 100 WH-UDZ03KE5 622 x 824 x 298 37 6,455
KIT-ADC05K3E5UK 5.00 / 5.10 5.00 / 3.03 5.00 / 4.90 A+++ / A++ A+ WH-ADC0309K3E5UK 100 WH-UDZ05KE5 795 x 875 x 320 55 6,575
1ph
KIT-ADC07K3E5UK 7.00 / 4.86 7.00 / 2.92 6.70 / 4.72 A+++ / A++ A+ WH-ADC0309K3E5UK 100 WH-UDZ07KE5 795 x 875 x 320 55 6,679
KIT-ADC09K3E5UK 9.00 / 4.55 8.90 / 2.93 9.00 / 4.18 A+++ / A++ A+ WH-ADC0309K3E5UK 100 WH-UDZ09KE5 795 x 875 x 320 55 6,918

Piping information Electrical information (power supply to indoor)


Kit kW 3.0 5.0 7.0 9.0 Single phase
Piping diameter (liquid - gas) Inch 1/4 - 1/2 1/4 - 5/8 1/4 - 5/8 1/4 - 5/8 Kit kW 3.0 5.0 7.0 9.0
3 ~ 40 / 3 ~ 40 / 3 ~ 40 / Electric backup heater kW 3.00 3.00 3.00 3.00
Pipe length range m 3 ~ 25
3 ~ 50 1) 3 ~ 50 1) 3 ~ 50 1)
Recommended fuse A 16 / 16 16 / 16 25 / 16 25 / 16
Elevation difference (in / out) m 20 30 30 30
Recommended minimum cable 3 x 1.5 / 3 x 1.5 / 3 x 2.5 / 3 x 2.5 /
mm²
Pre-charged pipe length m 10 10 10 10 size, supply 1 / 2 2) 3 x 1.5 3 x 1.5 3 x 1.5 3 x 1.5
Additional gas amount g/m 20 25 25 25

1) Operation range down to -25 °C in heating with 3 ~ 40 m pipe length range, operation range down to -15 °C in heating with 3 ~ 50 m pipe length range. 2) Check local regulations.* EER and COP calculation is
based in accordance to EN14511. ** This product is designed to comply with the European Water Quality Directive 98/83/EC amended by 2015/1787/EU. The lifespan of the product is not guaranteed in the case
of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to
these cases are the customer’s responsibility.

NEW Aquarea High Performance Refrigerant Split Bi‑bloc


K Generation Single phase. Heating and Cooling · R32 New 2023
Wi-Fi adapter included.
Indoor unit (H x W x D): 892 x 500 x 348 mm.
Operation range down to -25 °C 1) in heating. Tentative data
Kit Indoor unit Outdoor unit RRP
Heating capacity / Cooling Energy class Weight Dimension Weight
COP capacity / EER
A +7 °C, A +7 °C, A 35 °C, W Heat / Cool HxWxD
W 35 °C W 55 °C 7 °C (W 35 °C / W 55 °C)

kW / COP kW / COP kW / EER A+++ to D kg mm kg £


KIT-WC03K3E5 3.20 / 5.33 3.20 / 2.81 3.20 / 3.52 A+++ / A++ WH-SDC0309K3E5 WH-UDZ03KE5 622 x 824 x 298 37 3,690
KIT-WC05K3E5 5.00 / 5.10 5.00 / 3.03 5.00 / 3.05 A+++ / A++ WH-SDC0309K3E5 WH-UDZ05KE5 795 x 875 x 320 55 3,810
1ph
KIT-WC07K3E5 7.00 / 4.86 7.00 / 2.92 6.70 / 3.03 A+++ / A++ WH-SDC0309K3E5 WH-UDZ07KE5 795 x 875 x 320 55 3,914
KIT-WC09K3E5 9.00 / 4.55 8.90 / 2.93 8.20 / 2.72 A+++ / A++ WH-SDC0309K3E5 WH-UDZ09KE5 795 x 875 x 320 55 4,153

Piping information Electrical information (power supply to indoor)


Kit kW 3.0 5.0 7.0 9.0 Single phase
Piping diameter (liquid - gas) Inch 1/4 - 1/2 1/4 - 5/8 1/4 - 5/8 1/4 - 5/8 Kit kW 3.0 5.0 7.0 9.0
3 ~ 40 / 3 ~ 40 / 3 ~ 40 / Electric backup heater kW 3.00 3.00 3.00 3.00
Pipe length range m 3 ~ 25
3 ~ 50 1) 3 ~ 50 1) 3 ~ 50 1)
Recommended fuse A 16 / 16 16 / 16 25 / 16 25 / 16
Elevation difference (in / out) m 20 30 30 30
Recommended minimum cable 3 x 1.5 / 3 x 1.5 / 3 x 2.5 / 3 x 2.5 /
mm²
Pre-charged pipe length m 10 10 10 10 size, supply 1 / 2 2) 3 x 1.5 3 x 1.5 3 x 1.5 3 x 1.5
Additional gas amount g/m 20 25 25 25

1) Operation range down to -25 °C in heating with 3 ~ 40 m pipe length range, operation range down to -15 °C in heating with 3 ~ 50 m pipe length range. 2) Check local regulations.* EER and COP calculation is
based in accordance to EN14511. ** This product is designed to comply with the European Water Quality Directive 98/83/EC amended by 2015/1787/EU. The lifespan of the product is not guaranteed in the case
of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic water quality. Maintenance and warranty costs related to
these cases are the customer’s responsibility.

15
Aquarea High Performance
Aquarea High Performance Monobloc J Generation Single
phase. Heating and Cooling - MDC · R32
Wi-Fi adapter included.
Operation range down to -20 °C in heating.

Outdoor unit Heating capacity / COP Cooling capacity / EER Energy class Dimension Weight RRP
A +7 °C, W 35 °C A +7 °C, W 55 °C A 35 °C, W 18 °C Heat / Cool (W 35 °C / W 55 °C) HxWxD
kW / COP kW / COP kW / EER A+++ to D mm kg £
KIT-MDC05J3E5 5.00 / 5.08 5.00 / 3.01 5.00 / 5.05 A+++ / A++ 865 x 1 283 x 320 99 3,023
1ph KIT-MDC07J3E5 7.00 / 4.76 7.00 / 2.82 7.00 / 4.73 A+++ / A++ 865 x 1 283 x 320 104 3,542
KIT-MDC09J3E5 9.00 / 4.48 8.95 / 2.78 9.00 / 4.25 A+++ / A++ 865 x 1 283 x 320 104 3,891

Piping information Electrical information (power supply to indoor)


Outdoor unit kW 5.0 7.0 9.0 Single phase
Water pipe connector Inch R 1¼   R 1¼   R 1¼   Outdoor unit kW 5.0 7.0 9.0
Electric backup heater kW 3.00 3.00 3.00
Recommended fuse A 30 / 15 30 / 15 30 / 16
Recommended minimum cable size, supply 1 / 2 1) mm² 3 x 1.5 / 3 x 1.5 3 x 2.5 / 3 x 1.5 3 x 2.5 / 3 x 1.5

1) Check local regulations.* EER and COP calculation is based in accordance to EN14511.

Aquarea High Performance Mono‑bloc H Generation Single


phase. Heating and Cooling - MDC · R410A
Optional Wi-Fi adapter (CZ-TAW1B).
Operation range down to -20 °C in heating.

Outdoor unit Heating capacity / COP Cooling capacity / EER SCOP Energy class (heating) Dimension Weight RRP
A +7 °C, W 35 °C A +7 °C, W 55 °C A 35 °C, W 18 °C W 35 °C / W 55 °C W 35 °C / W 55 °C HxWxD
kW / COP kW / COP kW / EER A+++ to D mm kg £
WH-MDC12H6E5 12.00 / 4.74 12.00 / 2.93 9.39 / 4.65 4.82 / 3.42 A+++ / A++ 1 410 x 1 283 x 320 140 4,781
1ph
WH-MDC16H6E5 16.00 / 4.28 14.50 / 2.72 11.40 / 4.10 4.82 / 3.33 A+++ / A++ 1 410 x 1 283 x 320 140 5,568

Piping information Electrical information (power supply to indoor)


Outdoor unit kW 12.0 16.0 Single phase
Water pipe connector Inch R 1¼   R 1¼   Outdoor unit kW 12.0 16.0
Electric backup heater kW 6,00 6,00
Recommended fuse A 30 / 30 30 / 30
Recommended minimum cable size, supply 1 / 2 1) mm² 3 x 4.0 or 6.0 / 3 x 4.0 3 x 4.0 or 6.0 / 3 x 4.0

1) Check local regulations.* EER and COP calculation is based in accordance to EN14511.

Aquarea T‑CAP
NEW Aquarea T‑CAP Refrigerant Split All in One K Generation
Single phase. Heating and Cooling · R32 New 2023
Wi-Fi adapter included.
Indoor unit (H x W x D): 1 642 x 599 x 602 mm.
Operation range down to -28 °C in heating.
Kit Indoor unit Outdoor unit RRP
Heating capacity / Cooling Energy class Weight Dimension Weight
COP capacity / EER Heat / Cool
A +7 °C, A +7 °C, A 35 °C, W 35 °C / DHW HxWxD
W 35 °C W 55 °C W 7 °C W 55 °C
kW / COP kW / COP kW / EER A+++ to D A+ to F kg mm kg £
KIT-AXC09KE5UK 9.00 / 5.03 9.00 / 3.07 8.80 / 3.11 A+++ / A++ A WH-ADC0912K6E5UK 101 WH-UXZ09KE5 1340 x 900 x 320 88 8,442
1ph
KIT-AXC12KE5UK 12.10 / 4.84 12.10 / 3.04 10.70 / 2.68 A+++ / A++ A WH-ADC0912K6E5UK 101 WH-UXZ12KE5 1340 x 900 x 320 88 9,455

Piping information Electrical information (power supply to indoor)


Kit kW 9.0 12.0 Single phase
Piping diameter (liquid - gas) Inch 1/4 - 1/2 1/4 - 1/2 Kit kW 9.0 12.0
Pipe length range m 3 ~ 30 3 ~ 30 Electric backup heater kW 6.00 6.00
Elevation difference (in / out) m 20 20 Recommended fuse A 30 / 30 30 / 30
Pre-charged pipe length m 10 10 Recommended minimum cable size, supply 1 / 2 1) mm² 3 x 4.0 / 3 x 4.0 3 x 4.0 / 3 x 4.0
Additional gas amount g/m 30 30

1) Check local regulations.* EER and COP calculation is based in accordance to EN14511. ** This product is designed to comply with the European Water Quality Directive 98/83/EC amended by 2015/1787/EU.
The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic
water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility. *** Available Autumn 23. **** Tentative data.

16
AQUAREA INDEX AQUAREA

Aquarea T‑CAP.
For retrofit and new builds, Aquarea T‑CAP is the ideal solution for those installations where the output
capacity is demanding. The entire Aquarea T‑CAP line-up is excellent for replacing gas or oil boilers and
for connecting to new underfloor heating, radiators or fan coil units. Aquarea T‑CAP can maintain the
heat pump output capacity until -20 °C1) outdoor temperature without the help of an electrical booster
heater, offering high heating capacity even at low ambient temperatures.
1) At 35 °C flow temperature.

Aquarea T‑CAP Mono‑bloc J Generation R32.


R32 Refrigerant: A ‘small’ change that changes everything.
With Mono‑bloc, the refrigerant circuit is sealed inside the outdoor unit, so
there is no need to worry about the amount of refrigerant per room.

65 °C1) water temperature possible.


By optimising the system and the refrigerant cycle, the unit can work under
higher pressure and realise a water temperature of 65°C.
1) In case of ΔT setting with remote controller is 15 °C and outdoor ambient temperature is 5 to 20 °C, 65 °C hot water temperature is
possible. Even with the T‑CAP series, capacity will drop when water temperature reaches 65 °C.

How Aquarea T‑CAP maintains performance even at -20 °C outdoors


A patent has been obtained for
technology that can maintain heating
capacity even in low outdoor
temperatures through optimal control
that comes from incorporating dual-
piped heat exchanger into the
refrigeration cycle.

Dual-piped heat exchanger.


Low pressure and low-temperature
refrigerant in the inner pipe.

17
Aquarea T‑CAP
NEW Aquarea T‑CAP Refrigerant Split Bi‑bloc K Generation
Single phase / Three phase. Heating and Cooling · R32 New 2023
Wi-Fi adapter included.
Indoor unit (H x W x D): 892 x 500 x 348 mm.
Operation range down to -28 °C in heating. Tentative data
Kit Indoor unit Outdoor unit RRP
Heating capacity / Cooling Energy class Weight Dimension Weight
COP capacity / EER
A +7 °C, A +7 °C, A 35 °C, W Heat / Cool HxWxD
W 35 °C W 55 °C 7 °C (W 35 °C / W 55 °C)

kW / COP kW / COP kW / EER A+++ to D kg mm kg £


Kit 3 kW electric heater
1ph KIT-WXC09K3E5 9.00 / 5.03 9.00 / 3.07 8.80 / 3.11 A+++ / A++ WH-SXC09K3E5 — WH-UXZ09KE5 1 340 x 900 x 320 88 5,185
3ph KIT-WXC09K3E8 9.00 / 5.03 — 8.80 / 3.11 A+++ / A++ WH-SXC09K3E8 — WH-UXZ09KE8 1 340 x 900 x 320 88 6,667
Kit 6 kW electric heater
1ph KIT-WXC12K6E5 12.10 / 4.84 12.10 / 3.04 10.70 / 2.68 A+++ / A++ WH-SXC12K6E5 — WH-UXZ12HE5 1 340 x 900 x 320 88 6,450
Kit 9 kW electric heater
3ph KIT-WXC12K9E8 12.10 / 4.84 12.10 / 3.04 10.70 / 2.68 A+++ / A++ WH-SXC12K9E8 — WH-UXZ12HE8 1 340 x 900 x 320 88 7,219

Piping information Electrical information (power supply to indoor)


Kit kW 9.0 12.0 Single phase Single phase Three phase Three phase
(3 kW) (6 kW) (3 kW) (9 kW)
Piping diameter (liquid - gas) Inch 1/4 - 1/2 1/4 - 1/2
Kit kW 9.0 12.0 9.0 12.0
Pipe length range m 3 ~ 30 3 ~ 30
Electric backup heater kW 3.00 6.00 3.00 9.00
Elevation difference (in / out) m 20 20
Recommended fuse A — — — —
Pre-charged pipe length m 10 10
Recommended minimum cable
Additional gas amount g/m 30 30 mm² — — — —
size, supply 1 / 2 1)

1) Check local regulations.* EER and COP calculation is based in accordance to EN14511. ** This product is designed to comply with the European Water Quality Directive 98/83/EC amended by 2015/1787/EU.
The lifespan of the product is not guaranteed in the case of the use of groundwater, such as spring water or well water, the use of tap water when salt or other impurities are contained, nor in areas of acidic
water quality. Maintenance and warranty costs related to these cases are the customer’s responsibility. *** Tentative data.

Aquarea T‑CAP Refrigerant Split Bi‑bloc H Generation Single


phase / Three phase. Heating and Cooling - SXC · R410A
Wi-Fi adapter included.
Indoor unit (H x W x D): 892 x 500 x 340 mm.
Operation range down to -28 °C in heating.
Kit Indoor unit Outdoor unit RRP
Heating capacity / COP Cooling Energy class Weight Dimension Weight
capacity / EER
A +7 °C, A +7 °C, A 35 °C, W Heat / Cool HxWxD
W 35 °C W 55 °C 18 °C (W 35 °C / W 55 °C)

kW / COP kW / COP kW / EER A+++ to D kg mm kg £


KIT-WXC09H3E5 9.00 / 4.84 9.00 / 2.94 7.00 / 5.19 A+++ / A++ WH-SXC09H3E5 43 WH-UX09HE5 1 340 x 900 x 320 101 4,593
1ph
KIT-WXC12H6E5 12.00 / 4.74 12.00 / 2.88 10.00 / 5.13 A++ / A++ WH-SXC12H6E5 43 WH-UX12HE5 1 340 x 900 x 320 101 5,753
3ph KIT-WXC16H9E8 16.00 / 4.28 16.00 / 2.71 12.20 / 3.49 A++ / A++ WH-SXC16H9E8 45 WH-UX16HE8 1 340 x 900 x 320 118 7,627

Piping information Electrical information (power supply to indoor)


Kit kW 9.0 12.0 16.0 Single phase Three phase
Piping diameter (liquid - gas) Inch 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8 Kit kW 9.0 12.0 16.0
Pipe length range m 3 ~ 30 3 ~ 30 3 ~ 30 Electric backup heater kW 3.00 6.00 9.00
Elevation difference (in / out) m 20 20 20 Recommended fuse A 30 / 30 30 / 30 16 / 16
Pre-charged pipe length m 10 10 10 Recommended minimum 3 x 4.0 or 6.0 / 3 x 4.0 or 6.0 /
mm² 5 x 1.5 / 5 x 1.5
Additional gas amount g/m 50 50 50 cable size, supply 1 / 2 1) 3 x 4.0 3 x 4.0

1) Check local regulations.* EER and COP calculation is based in accordance to EN14511.

18
AQUAREA INDEX AQUAREA

Aquarea T‑CAP
Aquarea T‑CAP Monobloc J Generation Single phase / Three
phase. Heating and Cooling - MXC · R32
Wi-Fi adapter included.
Operation range down to -20 °C in heating.

Outdoor unit Heating capacity / COP Cooling capacity / EER Energy class Dimension Weight RRP
A +7 °C, W 35 °C A +7 °C, W 55 °C A 35 °C, W 18 °C Heat / Cool (W 35 °C / W 55 °C) HxWxD
kW / COP kW / COP kW / EER A+++ to D mm kg £
KIT-MXC09J3E5 9.00 / 5.08 9.00 / 3.08 9.00 / 4.62 A+++ / A++ 1 410 x 1 283 x 320 140 4,837
1ph
KIT-MXC12J6E5 12.00 / 4.80 12.00 / 3.05 12.00 / 3.95 A+++ / A++ 1 410 x 1 283 x 320 140 6,005
3ph KIT-MXC16J9E8 16.00 / 4.52 16.00 / 2.86 16.00 / 3.75 A+++ / A++ 1 410 x 1 283 x 320 150 7,707

Piping information Electrical information (power supply to indoor)


Outdoor unit kW 9.0 12.0 16.0 Single phase Three phase
Water pipe connector Inch R 1¼ R 1¼ R 1¼ Outdoor unit kW 9.0 12.0 16.0
Electric backup heater kW 3.00 6.00 9.00
Recommended fuse A 30 / 30 30 / 30 20 / 20
Recommended minimum 3 x 4.0 or 6.0 / 3 x 4.0 or 6.0 /
mm² 5 x 1.5 / 5 x 1.5
cable size, supply 1 / 2 1) 3 x 4.0 3 x 4.0

1) Check local regulations.* EER and COP calculation is based in accordance to EN14511.

Aquarea Designer - online tool.


Hydraulic scheme generator.
With Panasonic’s online tool, projects can
This tool allows costumers to select the scheme
AQUAREA DESIGNER

be developed simply and easily. The newly between more than 110 different type according to
developed tool is optimised to help professionals their installation requirements in a simple way. It
easily identify the most appropriate Aquarea air to possible to download hydraulic and electric part in pdf
water heat pump for a particular application. and in cad file. Moreover it is available a list, one for
each scheme type, with the Panasonic codes and third
party codes that the costumers need to realise the
installation in a proper way.

AR Heat Pump Viewer.


This tool allows you to see how a Panasonic
Aquarea Heat Pump looks in a home, utilising
augmented reality.

Heating demand calculator.


This software can quickly and easily determine the
heating requirements for the rooms in a project.
The Heating demand calculator will help determine
approximately how much power is needed to heat each
room individually. The result in kilowatts will help you
choose the heat pump best suited to your needs.

19
FAN COILS

Fan coils
Smart fan coils
Extremely compact (only 129 mm deep).
Touch screen thermostat.
3-way valve included.

Fan coils Total capacity Air flow Dimension Weight RRP


Cooling Heating
Med Med Max HxWxD
kW kW m³/min mm kg £
PAW-AAIR-200-2 0.5 0.4 2.7 735 x 579 x 129 17 720
PAW-AAIR-700-2 0.9 0.8 5.3 935 x 579 x 129 20 779
1ph
PAW-AAIR-900-2 1.6 1.2 7.7 1 135 x 579 x 129 23 933
NEW PAW-AAIR-1100-2 1.8 1.4 9.6 1 335 x 579 x 129 26 TBC

* Smart fan coils is produced by Innova.

Fan coils - ducted


2 and 4-pipe, left and right hand configurations.
5-speed AC fan motor(s).
2 way or 3 way ON / OFF valves.

Fan coils Total capacity Air flow External pressure Dimension Weight RRP
Cooling 1) Heating 2)
Med Med Max Max HxWxD
Left connection Right connection kW kW m³/min Pa mm kg £
PAW-FC2A-D040L PAW-FC2A-D040R 2.4 2.9 499 85 220 x 938 x 430 20 380
2-pipe
PAW-FC2A-D060L PAW-FC2A-D060R 4.6 5.3 933 115 220 x 1 307 x 430 26 459
1ph
PAW-FC4A-D040L PAW-FC4A-D040R 2.3 1.6 467 85 220 x 938 x 430 22 408
4-pipe
PAW-FC4A-D060L PAW-FC4A-D060R 4.4 2.9 885 115 220 x 1 307 x 430 28 496

Water connections information


Fan coils 040 060
Type Female gas threaded Female gas threaded
Water connections Inch 1/2 1/2

1) According to Eurovent standard. Air: 27 °C DB / 19 °C WB. Water in / out: 7 °C / 12 °C. 2) Air: 20 °C. Water in / out: 50 °C / 45 °C.
Values indicated are for 0 Pa external static pressure, for additional pressure characteristics, please refer the selection software.

Fan coils - 4 way cassette


2-pipe configurations.
3-speed AC fan motor.
Cleanable synthetic-type air filter.

Fan coils Total capacity Air flow Dimension Weight RRP


Cooling 1) Heating 2) including panel Fan Panel
Med Med Max HxWxD coil
Panel kW kW m³/min mm kg € €
PAW-FC2A-U050-2 PAW-FC-KPU5070 4.4 6.0 979 339 x 960 x 960 37,1 1,284 237
1ph 2-pipe PAW-FC2A-U060-2 PAW-FC-KPU5070 5.4 7.4 1 159 339 x 960 x 960 37,1 1,315 237
PAW-FC2A-U070-2 PAW-FC-KPU5070 6.5 9.2 1 447 339 x 960 x 960 39,6 1,368 237

Water connections information


Fan coils 050 060 070
Type Female gas threaded Female gas threaded Female gas threaded
Water connections 2-pipe Inch 1 1 1
Water connections 4-pipe (cool - heat) Inch —-— 1 - 3/4 1 - 3/4

1) According to Eurovent standard. Air: 27 °C DB / 19 °C WB. Water in / out: 7 °C / 12 °C. 2) According to Eurovent standard. Air: 20 °C. Water in / out: 45 °C / 40 °C.

20
AQUAREA INDEX DHW TANKS AND VENTILATION

DHW tanks and Ventilation


DUO Pre-plumbed tank

Tank Material Water volume Energy efficiency class Dimension Weight RRP
Hight / Diameter
L A+ to F mm kg £
PAW-TD20B7PP-UK Stainless steel 185 C 1 992 / 550 51 2,651
1ph PAW-TD23B6E5PP-UK Stainless steel 225 A 1755 / 595 TBC 2,899
PAW-TD30B7PP-UK Stainless steel 285 C 2 030 / 630 64 3,024

1) Tested pursuant to EN 12897:2006. 2) EU Regulation 812/2013.

Stainless steel tanks

Tank Material Water volume Coil Size Energy efficiency Dimension Weight RRP
class Hight / Diameter
L m2 A+ to F mm kg £
KIT-G3TD20C1E5-1 Stainless steel 192 1.80 A 1 270 / 595 50 1,160
1ph KIT-G3TD30C1E5-1 Stainless steel 284 1.80 A 1 750 / 595 61 1,459
NEW KIT-G3TD30C1E5HI-1 Stainless steel 280 2.35 A 1 750 / 595 65 1,592

* Stainless steel tanks are produced by OSO.

Buffer tanks

Tank Material Water volume Energy efficiency class Dimension Weight RRP
Hight / Diameter
L A+ to F mm kg £
PAW-BTANK50L-2 Stainless Steel 48 B 636 / 430 17 365
PAW-BTANK100L Stainless Steel 100 C 1175 / 430 28 470
PAW-BTANKG200L Stainless Steel 199 B 1275 / 595 47 592
PAW-BTANKG260L Stainless Steel 289 B 1755 / 595 57 706

* Automatic air vent and drain cock are included. Built-in pocket sensor (sensor not included). ** Buffer tank are produced by OSO.

Heat recovery ventilation unit


Designed for areas up to approximately 140 m².
High energy-efficiency rotary heat exchanger with EC - technology fans.

Heat recovery ventilation unit Air flow Energy class Dimension Weight RRP
Nominal Maximum Basic unit With local control HxWxD
Left connection Right connection m³/min m³/min on demand mm kg £
1ph PAW-A2W-VENTA-L PAW-A2W-VENTA-R 204 @ 50 Pa 292 @ 100 Pa A A 450 x 598 x 500 46 2,024

* Heat recovery ventilation unit is produced by Systemair.

NEW Counter flow ventilation

Counter flow ventilation Mounting position Air flow Energy class Dimension Weight RRP
Nominal Maximum HxWxD
m³/l m³/l mm kg £
PAW-VENTX10Z Horizontal / Vertical 91 130 A 255 x 580 x 580 19 837
PAW-VENTX15Z Horizontal / Vertical 147 210 A 255 x 580 x 580 19 963
PAW-VENTX20H Horizontal 109 155 A 260 x 480 x 800 25 1,197
PAW-VENTX20V Vertical 112 170 A 510 x 430 x 625 32 1,197
1ph
PAW-VENTX30H Horizontal 210 300 A 295 x 600 x 795 30 1,326
PAW-VENTX30V Vertical 210 300 A 590 x 575 x 785 38 1,366
PAW-VENTX40H Horizontal 238 340 A 290 x 650 x 1 150 38 1,539
PAW-VENTX40V Vertical 266 380 A 590 x 735 x 785 42 1,495

* Produced by Sinergia.

21
ACCESSORIES AND CONTROL

Dual controller system RRP £ Cascade manager RRP £

NEW additional remote controller for CZ-RTW1 TBC Cascade manager for Aquarea Heat PAW-A2W-CMH-2 1,205
K and L Generations Pumps.

All in One accessories RRP £ Room thermostats RRP £

Flexible pipings and wall mounting PAW-ADC-PREKIT-1 471 Wired LCD room thermostat with PAW-A2W-RTWIRED 100
plate for All in One J Generation (not weekly timer.
compatible with ).
Wireless LCD room thermostat with PAW-A2W- 165
RTWIRELESS
Special outdoor supports RRP £ weekly timer.

Tray for condenser water compatible PAW-WTRAY 145


with outdoor elevation platform. Sensors for Aquarea H Generation onwards RRP £

Outdoor elevation platform. PAW-GRDSTD40 145 Outdoor ambient sensor. PAW-A2W-TSOD 42


Dimension (H x W x D):
400 x 900 x 400 mm
Outdoor base ground support for noise PAW-GRDBSE20 133 Zone room sensor. PAW-A2W-TSRT 42
and vibration absorption.
Dimension (H x W x D): 600 x 95 x 130 mm
Safe working load: 500 kg
Zone water sensor. PAW-A2W-TSHC 42

PCB’s for additional functions RRP £


Solar sensor. PAW-A2W-TSSO 42
PCB for advanced functions in J and CZ-NS4P 160
Buffer tank sensor. Zone water sensor PAW-A2W-TSBU 42
H Generations.
PAW-A2W-TSHC is also required to
PCB for advanced functions in K and CZ-NS5P TBC operate buffer tank sensor.
L Generations.

Smart fan coil accessories RRP £


Deice accessories RRP £
Kits of 2 legs to protect the water PAW-AAIR-LEGS-1 56
Base pan heater for all old Bi‑bloc and CZ-NE1P TBC pipings.
Monobloc (not for the 3 and 5 kW).
Motor connection cable for units with PAW-AAIR-RHCABLE 27
Base pan heater for Bi‑bloc 3 and CZ-NE2P 146 hydraulic connections on the right.
5 kW (except L Generation) and 7 and
9 kW K Generation.
Fan coil accessories RRP £
Base pan heater for J and CZ-NE3P 146
H Generations.
Advanced wired remote controller for PAW-FC-RC1 95
Base pan heater for 5, 7 and 9 kW CZ-NE4P TBC fan coil.
L Generation.

2 way valve + drain pan for ducted PAW-FC-2WY-11/55-1 67


Hydraulic accessories RRP £ models 010-060.
2 way valve + drain pan for ducted PAW-FC-2WY-65/90-1 76
3 way valve kit for inside of hydrokit CZ-NV1 274 models 070-080.
for J and H Generations.
2 way valve + drain pan for ducted PAW-FC-2WY-F040 90
3 way valve kit for inside of hydrokit CZ-NV2 TBC model F040.
for K and L Generations.
3 way valve + drain pan for ducted PAW-FC-3WY-11/55-1 98
3 way valve for DHW Tanks. PAW-3WYVLV-HW 162
models 010-060.
3 way valve + drain pan for ducted PAW-FC-3WY-65/90-1 110
models 070-080.
1 anti-freeze valve. PAW-A2W-AFVLV 106
2 valves are required per heat pump. 3 way valve + drain pan for ducted PAW-FC-3WY-F040 145
model F040.
Optional magnet for the water filter in PAW-A2W-MGTFILTER 37 2 way valve for wall-mounted. PAW-FC2-2WY-K007 79
H Generation models.
3 way valve for wall-mounted. PAW-FC2-3WY-K007 126

Accessories interfaces RRP £ Sanitary tank accessories RRP £

Aquarea Smart Cloud for remote CZ-TAW1B 178 Tank sensor with 6 m cable length. PAW-TS1 36
control and maintenance through Tank sensor with 20 m cable length. PAW-TS2 42
wireless or wired LAN.
Tank sensor with 6 m cable length and PAW-TS4 42
10 m extension cable for CZ-TAW1B. CZ-TAW1-CBL 48 only 6 mm diameter.
External meter gateway for K and PAW-A2W-EXTMETER TBC Temperature sensor kit for third party CZ-TK1 72
L Generations. tank (with copper pocket and 6 m
length sensor cable).
KNX interface for H Generation PAW -AW-KNX-H 240
onwards (Intesis).
Outdoor unit noise reduction kit RRP £

Modbus interface for H Generation PAW-AW-MBS-H 240


Noise reduction kit for outdoor units CZ-UG30 170
onwards (Intesis).
(-3 dB(A)).

KNX interface for H Generation PAW-AZAW-KNX-1 204


onwards (Airzone).

Modbus interface for H Generation PAW-AZAW-MBS-1 210


onwards (Airzone).

22
AQUAREA INDEX ACCESSORIES AND CONTROL

Digital remote control (white). PAW-VEN-CTRLW 101


Heat recovery ventilation accessories RRP £ Integrated air quality, temperature and
humidity sensors
Supply and extract filters kit. PAW-VEN-FLTKIT 55 Electrical duct heater 0.5 kW, PAW-VEN-HTR05 346
DN160 mm
Electrical duct heater 1.0 kW, PAW-VEN-HTR10 409
Optional PCB for additional functions. PAW-VEN-ACCPCB 46 DN160 mm
Spare F7 filter kit (2 pcs) for models PAW-VEN-FLT1 32
10Z, 15Z, 20H and 20V
HRV touch control panel. White frame PAW-VEN-DPL 144 PAW-VEN-FLT2 36
Spare F7 filter kit (2 pcs) for models
(cable must be ordered separately).
30H and 30V
Spare F7 filter kit (2 pcs) for models PAW-VEN-FLT3 46
Cable with plug for electrical PAW-VEN-CBLEXT12 28 40H
connection between unit and control
panel, type CE and CD (12 m). Spare F7 filter kit (2 pcs) for models PAW-VEN-FLT4 49
40V
Twin plugs for installation of several PAW-VEN-DIVPLG 15
control panels type CD or CE for one Activated carbon filter (1 pc) for PAW-VEN-ACFLT1 19
unit. models 10Z, 15Z, 20H and 20V

HRV touch control panel wall-mounted PAW-VEN-DPLBOX 81 Activated carbon filter (1 pc) for PAW-VEN-ACFLT2 25
kit. models 30H and 30V
Activated carbon filter (1 pc) for PAW-VEN-ACFLT3 28
CO2 RH wall-mounted sensor. PAW-VEN-S-CO2RH-W 282 models 40H
Activated carbon filter (1 pc) for PAW-VEN-ACFLT4 37
CO2 wall-mounted sensor. PAW-VEN-S-CO2-W 328 models 40V
CO2 duct sensor. PAW-VEN-S-CO2-D 243

Wall bracket kit for stand-alone PAW-VEN-WBRK 30


installation on the wall.

Electrical duct heater 0.6 kW (includes PAW-VEN-HTR06 306


relay).
Electrical duct heater 1.2 kW (includes PAW-VEN-HTR12 347
relay).

NEW counter flow ventilation accessories RRP £

Digital remote control (black). PAW-VEN-CTRLB 101


Integrated air quality, temperature and
humidity sensors

23
ACCESSORIES

Smart meet Wiser


Introducing Wiser, the most comprehensive multi-zone heating system from Drayton.
Panasonic has partnered with Drayton by Schneider Electric to offer its Wiser room-by-room heating
control system. Seamlessly integrating with your Panasonic Aquarea Air Source Heat Pumps and the
Aquarea Smart Cloud and Service Cloud apps, the Wiser system provides an additional element of energy
control and simple home automation.

What makes Wiser wiser?

Simplicity. Flexibility. Multi-zoning.


Standard wallplate, Up to 3 channels, 16 Add radiator thermostats,
wireless devices. rooms, 63 devices. underfloor heating
controller or electrical
heat switch as required.

App control. Eco mode. Comfort mode.


Simple app with boost Combines weather Uses optimum start for
and away mode. compensation and optimum maximum comfort.
stop for maximum savings.

Heat report and insights. Geofencing. OpenTherm®.


View and compare Enhanced control with Digital boiler interface
temperatures across geofencing through enabling more efficient
single or multiple rooms. IFTTT. control.

This new partnership offers you the option the combine Benefits of Wiser
your new Panasonic’s Aquarea air source heat pumps with Wiser combines smart features with simplicity to bring
Wiser smart controls to provide you with room-by-room you the most complete home heating solution.
heating control by fitting Wiser with your Aquarea system. Wiser makes home personalisation affordable by allowing
The combination of smart controls will help make your you to start with a smart room thermostat and build a full
home as energy efficient as possible by bringing different multi-zone solution over time by adding radiator thermostats
electrical devices under the control of one app, helping and incorporating electrical and/or underfloor heating.
you to lower their bills and reduce your carbon footprint. · Smart heating and hot water control
Wiser can be set up in the usual way with the Panasonic · Easy zoning with radiator thermostats
Aquarea heat pump,and will enable you to monitor and · Control wet underfloor heating zones
easily adjust the heating in each room and via any web- · Incorporate electrical heating
enabled device, including Android and iOS applications and · Quick and easy installation
Internet browsers. · Schedule electrical appliances by adding Wiser Plugs

The Wiser Home app: Download in the App Store –


The app has been designed to make your life simple. Step-by-step search Wiser Home.
commissioning instructions guide you through the whole process in just a
few minutes.
The user interface has been designed to be intuitive so your customer will
have no problem taking control of their heating. Set up can be done within
seconds and programming couldn’t be easier. Boost, set point and room Scan the QR for more
information and to
selections can all be accessed from the home screen.
purchase your Wiser
home kit.

24
AQUAREA INDEX ACCESSORIES

20 °C 18 °C

Electrical heat switch Radiator thermostat

15 °C 18 °C 21 °C

Smart plug Electrical heat switch

19 °C 21 °C

Underfloor heating Room thermostat


controller

Features

Away mode. Schedules. Boost/cancel all. Eco mode. Insights and heat Moments.
Activate when away Set time and Boost all devices in Combines weather report. Group multiple
from home to temperature the system or cancel compensation & Track the system devices to be
reduce all set points schedules for every all overrides - optimum stop for performance to activated together
and save 24% of device to ensure full enables complete maximum savings. adapt heating to create a mood or
energy. multi-zoning system testing with schedules and ‘moment’.
efficiency. the tap of a button. settings to save
energy.

For more information on the Wiser product range and for purchasing please visit:
https://Wiser.draytoncontrols.co.uk/
To find your closest stockist, please refer to our Distribution Finder by scanning the QR.

Wiser room thermostat. Additional room thermostat WN704R0S0902


Wiser accessories* - add to rooms with radiator thermostats as a
convenient way to view and change the room
temperature. Works with all Wiser kits.
Wiser thermostat kit 1. One channel thermostat pack WT714R9K0902
ideal for heat pumps. Wiser plug. Set schedules for home appliances from WB704H1A0902
the Wiser heat app, this smart plug can be controlled
from your phone or by using voice activation with the
Wiser thermostat kit 3. Three channel thermostat WT734R9K0902
google assistant and amazon alexa. The built in
pack ideal for properties with two heating zones.
range entender also enables connectivity to devices
sited further away from the heat hub.
Wiser multi-zone kit 1. One channel thermostat WV714R9K0902
Wiser electrical heat switch. Wiser electrical heat WE714U1A0902
system with two radiator thermostats to start zoning switch + Wiser room thermostat will control any of
your system. the following applications: plinth heaters, electric
Wiser radiator thermostat. Add additional single WV704R0A0902 radiators, infared panels, electrical UFH.
radiator thermostats to any of the Wiser kits to
Wiser under floor heating controller. The Wiser WF762F1A0902
create more zones and benefit from maximum
underfloor heating controller enables complete
comfort and energy saving.
control over the entire heating system, no matter
what the application, via the Wiser home app.
* Wiser accessories, are compatible with Panasonic units, but are product from Drayton Controls
and are not available from Panasonic directly. Locally source, Panasonic is not selling this devices.

25
For more information on Aquarea, view our latest videos:

An introduction to Aquarea:
https://www.youtube.com/watch?v=Rr2R2zw__RU

How to check you Aquarea H and J Generations How to check your Aquarea H and J Generations DHW
current flow rates: tank temperature and heating flow and return
https://www.youtube.com/watch?v=LXVK1zgaM5E temperatures:
https://www.youtube.com/watch?v=0fCiyUzlqUw

How to check your Aquarea H and J Generations How to set up the Aquarea H and J Generations
efficiency, detailing energy used, energy heating time clock :
generated and COP: https://www.youtube.com/watch?v=0_jRklYPaRY
https://www.youtube.com/watch?v=FIVoMYzkCRI

26
EDITORIAL

For more information on the Aquarea Monobloc H and


J Generations installation guide:
This guide provides a step by step procedure for the installation of the Aquarea Monobloc unit, covering
basic installation to more advanced requirements, along with a guide to the controller set up process,
covering the each type of installation.

Download Aquarea Monobloc H and J Generations installation guide

27
Notes
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

28
Notes
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

29
Panasonic service
Our Panasonic Service teams are committed to ensuring your peace of mind. Best service is our aim.
Panasonic provides a team of highly trained technicians and engineers to deliver professional and responsive
services that meet the highest levels of quality and safety while being efficient and cost effective.
To find out more about Panasonic Heating & Cooling Solutions, please visit www.panasonic.co.uk/aircon.

Maintenance. Repair. Warranty.


To meet the requirements of the standard Panasonic offers a wide range of service In accordance with the regulations,
warranty, the product must be maintained agreements, like Panasonic Service+ for a Panasonic guarantees its products against
and serviced annually by a suitably trained maximized product lifetime. Leave the care hidden defects. Moreover, Panasonic grants
and qualified engineer. This way we can of your Panasonic products to the experts. to the professional purchaser a commercial
extend the lifetime of the product. In the unlikely event that something goes warranty, specific to the product families,
wrong, trust one of our qualified and subject to compliance of all the rules of
Panasonic trained experts to get things installation and use of its products.
back on track.

Panasonic Heating & Cooling Solutions


customer service
Panasonic enables different channels for end users or professionals to get in touch with us:

Use our European website www.panasonic.eu for contacting us.


Panasonic has implemented a contact page on the Panasonic Heating & Cooling Solutions
website for potential or existing Panasonic customers.

Another option is to contact the highly experienced teams at the Panasonic customer service center, who
are more than qualified to support Panasonic clients in 13 different languages across Europe.

Our service center for United Kingdom end customers:


0808 208 2115
Mo-Fr 9-17h
www.panasonic.co.uk/aircon
www.eggeassociats.net
Due to the ongoing innovation of our products, the specifications of this catalogue are valid barring typographic errors, and may be subject to minor modifications by the manufacturer without
prior warning in order to improve the product. The total or partial reproduction of this catalogue is prohibited without the express authorisation of Panasonic Marketing Europe GmbH.

Do not add or replace refrigerant other than the specified type. Manufacturer is not responsible for the
damage and deterioration in safety due to usage of the other refrigerant.
To find out how Panasonic cares for you, log on to: The outdoor units in this catalogue contains fluorinated greenhouse gases with a GWP higher than 150.

www.panasonic.co.uk/aircon

General requests:
Email: uk-aircon@eu.panasonic.com

Sales administration team:


Email: uk-aircon-salesadmin@eu.panasonic.com

Technical service team:


Email: uk-aircon-tech@eu.panasonic.com
UK Office : +44 (0) 1707 378670
UK-AQUPLST0323/01

Panasonic Heating & Ventilation Air-Conditioning UK Ltd.


Registered Office: Ground Floor, Building 3, Albany Place, Hyde Way, Welwyn
Garden City, Hertfordshire AL7 3BT
Company Registration: 02371708

You might also like