Catch Basin Detail: Legend
Catch Basin Detail: Legend
Catch Basin Detail: Legend
PLUMBING NOTES
GRADES OF HORIZONTAL
- RUNS ALL PIPINGS IN PERFECT ALIGNMENT AND FORM 6000
- GRADE OF NOT LESS THAN 2 %
3000 3000
CHANGE IN DIRECTION
500
- ALL CHANGES OF DIRECTION SHALL BE MADE BY AN
500 300
APPROPRIATE USE OF 45° WYE, LONG SWEPT QUATER BEND.
- WHEN THE CHANGE OF FLOW IS FROM HORIZONTAL TO 400
100
VERTICAL STACK, SHORT QUARTER BEND MAYBE USED IN
WASTE LINE. INLET
C.O.
- TEE OR CROSS TEE MAYBE USED IN VENT PIPES.
PROHIBITTED FITTINGS 3 C.B. C.B. 3 OUTLET
500
4" Ø
400
F.D.
1000
K.S. LAV.
1300
- NO DOUBLE HUB OR TEE BRANCHES SHALL BE USED ON W.C. CONCRETE
HORIZONTAL SOIL OR WASTE LINES. DRILLING AND TAPE OF PIPE
HOUSE DRAIN IS PROHIBITED INCLUDING WASTE OR VENT
PIPES.
PIPES AND CLEAN OUTS
3500
3500
CLEAN OUTS ARE REQUIRED UNDER THE FOLLOWING
CONDITIONS:
2200
- EVERY CHANGE OF DIRECTION
- EVERY 15 METERS IN HORIZONTAL RUN OF PIPES
- 1.5 METERS THE PROPERTY BEFORE THE DRAINAGE
- AT THE END OF ANY HORIZONTAL PIPES
- THE DIGESTIVE CHAMBER OF THE SEPTIC VAULT MUST BE Catch Basin Detail
7000
7000
WATER PROOF NOT LESS THAN .30 METER OF AIR SPACE
MUST BE LEFT BETWEEN THE TOP OF THE SEWAGE AND
2 C.B. C.B.
2 2
P-1 Scale: 1:20 Mts.
3500
3500
C.B. C.B.
1 1
1500
1750
STOP BOX
GATE VALVE
LEGEND WATER METER
CHECK VALVE
W.C. WATER CLOSET GRADE LINE
K.S. KITCHEN SINK
LAV. LAVATORY M
GOOSE NECK
F.D. FLOOR DRAIN
C.O. CLEAN OUT
C.B. 175 PUBLIC WATER MAIN
CATCH BASIN CURB STOCK COCK
W.M. WATER METER 3175 2550 275
C.V. CHECK VALVE 6000
G.V. GATE VALVE
D.S. DOWN SPOUT
WATER LINE 3 Water Line Connection Detail
STORM DRAINAGE PIPE LINE A B C P-1 Nts.
1
P-1
Plumbing Layout
Scale: 1:50 Mts.
P-1
PTR. No. : JDC
STOREY RESIDENCE" AS SHOWN FOR PERMIT
MASTER PLUMBER OWNER