Catch Basin Detail: Legend

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

A B C

PLUMBING NOTES
GRADES OF HORIZONTAL
- RUNS ALL PIPINGS IN PERFECT ALIGNMENT AND FORM 6000
- GRADE OF NOT LESS THAN 2 %
3000 3000
CHANGE IN DIRECTION
500
- ALL CHANGES OF DIRECTION SHALL BE MADE BY AN
500 300
APPROPRIATE USE OF 45° WYE, LONG SWEPT QUATER BEND.
- WHEN THE CHANGE OF FLOW IS FROM HORIZONTAL TO 400

100
VERTICAL STACK, SHORT QUARTER BEND MAYBE USED IN
WASTE LINE. INLET
C.O.
- TEE OR CROSS TEE MAYBE USED IN VENT PIPES.
PROHIBITTED FITTINGS 3 C.B. C.B. 3 OUTLET

500
4" Ø

400
F.D.

1000
K.S. LAV.

1300
- NO DOUBLE HUB OR TEE BRANCHES SHALL BE USED ON W.C. CONCRETE
HORIZONTAL SOIL OR WASTE LINES. DRILLING AND TAPE OF PIPE
HOUSE DRAIN IS PROHIBITED INCLUDING WASTE OR VENT
PIPES.
PIPES AND CLEAN OUTS

3500

3500
CLEAN OUTS ARE REQUIRED UNDER THE FOLLOWING
CONDITIONS:

2200
- EVERY CHANGE OF DIRECTION
- EVERY 15 METERS IN HORIZONTAL RUN OF PIPES
- 1.5 METERS THE PROPERTY BEFORE THE DRAINAGE
- AT THE END OF ANY HORIZONTAL PIPES
- THE DIGESTIVE CHAMBER OF THE SEPTIC VAULT MUST BE Catch Basin Detail

7000

7000
WATER PROOF NOT LESS THAN .30 METER OF AIR SPACE
MUST BE LEFT BETWEEN THE TOP OF THE SEWAGE AND
2 C.B. C.B.
2 2
P-1 Scale: 1:20 Mts.

UNDERPART OF THE VAULT


- NO SEPTIC VAULT SHALL BE CONSTRUCTED UNDER THE
BUILDING
- ALL PLUMBING WORKS SHALL BE DONE BY A LICENSED
MASTER PLUMBER AND A LICENSED PUMBING CONTRUCTOR

3500

3500
C.B. C.B.
1 1
1500

1750
STOP BOX
GATE VALVE
LEGEND WATER METER
CHECK VALVE
W.C. WATER CLOSET GRADE LINE
K.S. KITCHEN SINK
LAV. LAVATORY M
GOOSE NECK
F.D. FLOOR DRAIN
C.O. CLEAN OUT
C.B. 175 PUBLIC WATER MAIN
CATCH BASIN CURB STOCK COCK
W.M. WATER METER 3175 2550 275
C.V. CHECK VALVE 6000
G.V. GATE VALVE
D.S. DOWN SPOUT
WATER LINE 3 Water Line Connection Detail
STORM DRAINAGE PIPE LINE A B C P-1 Nts.

WASTE PIPE LINE

1
P-1
Plumbing Layout
Scale: 1:50 Mts.

ENGINEER PRC. REG. No. :


PROJECT TITLE: REVISION/S: DRAWN BY: SHEET CONTENTS DESCRIPTION APPROVED BY: SHEET No.
TIN :

"PROPOSED 2-BEDROOM ELEVATED ONE CARLO J. BERRO

P-1
PTR. No. : JDC
STOREY RESIDENCE" AS SHOWN FOR PERMIT
MASTER PLUMBER OWNER
PLACE ISSUED :

LOCATION: Nevada St., Town And Country, Santo Tomas, Biñan, Laguna CHECKED BY :
DATE ISSUED :