FASCIA COVER G.I ROOFING 0.

60 THK PRE-PAINTED
WHITE APO BRAND W/ ACM ( WHITE COLOR)
7000
200 6600 200

800 200
11650
SEAOIL
FASCIA COVER G.I
ROOFING 0.60 THK
MOLDED BLUE ACRYLIC SEAOIL TEXT INCISED PRE- PAINTED WHITE
PUSH THRU CARBONATE BACKGROUND APO BRAND W/ ACM

1100
LIGHTED VIA LED MODULES (YELLOW COLOR)
CABINET CABINET LUBES

5700
4500
TOILET
SERVICE

1100
CF3:+2700
PUMP CF3:+2700
MDP
OFFICE
CF1:+2700

1100
PUMP GUARD M.E. ROOM
COMMON

200
TOILET CASHIER'S
FILLING STATION CF3:+2700 OFFICE

1100
CF3:+2700
A RIGHT SIDE ELEVATION DVR CABINET

2 SCALE 1:100mts.
fd
S.SINK

9000

FASCIA COVER G.I ROOFING 0.60 THK PRE-


200 PAINTED WHITE APO BRAND

800 200
BUILDING

A FLOOR PLAN LAYOUT


2 SCALE 1:100mts.

FASCIA COVER G.I ROOFING 0.60 THK PRE-


PAINTED WHITE APO BRAND W/ ACM
(YELLOW COLOR)

5700

4500
12350
CASHIERS BOOTH

200
PUMP GUARD DETAIL

6100
FILLING STATION
A REAR ELEVATION
2 SCALE 1:100mts.

S.SINK

fd
BUILDING

A ROOF PLAN
9000
EXTREME U EXTREME 95/97 2 SCALE 1:120mts.

EXCEED DIESEL
4,000 GALS UGT
FASCIA COVER G.I ROOFING 0.60 THK PRE-
200 PAINTED WHITE APO BRAND SYMBOLS DESCRIPTION

800 200
2,000 GALS 4,000 GALS
PHILIPS COOL DAYLIGHT

CORRIDOR
LED BULB 19W,E27 CAP
CF1 600mmx600mm ACOUSTIC
BOARD
FASCIA COVER G.I ROOFING 0.60 THK PRE- PVC SPANDREL
MOLDED BLUE ACRYLIC SEAOIL TEXT INCISED CF2
PAINTED WHITE APO BRAND W/ ACM (TO VERIFIED)
PUSH THRU CARBONATE BACKGROUND
(YELLOW COLOR) LIGHTED VIA LED MODULES
HARDIFLEX FICEM BOARD
CF3 IN PLAT LATEX WITH FINISH

5700

4500
CASHIERS BOOTH
SPREADER DETAIL
12350
1200 4000 2000 4650 500

500
200
CABINET CABINET LUBES
FILLING STATION PUMP GUARD DETAIL TOILET
SERVICE
A FRONT ELEVATION CF3:+2700
MDP
CF3:+2700

4400
OFFICE
2 SCALE 1:100mts.
CF1:+2700
M.E. ROOM
COMMON LOCKER
TOILET ROOM
CF3:+2700
CF3:+2700
9000
OWS

1000
fd
S.SINK
ca
CF2: ±3000

200
7000

7000
BUILDING
9000 A REFLECTED CEILING PLAN
2 SCALE 1:120mts.

FILLING STATION FILLING STATION


A ROOF PLAN A REFLECTED CEILING PLAN
2 SCALE 1:175mts.
2 SCALE 1:175mts.

A SITE ON PLAN
2 SCALE 1:150mts.

APPROVED BY: PROJECT: APPROVED BY: NOTED BY: SHEET CONTENT: SHEET NO.

Sherwin p. Foronda SEAOIL PHILIPPINES, INCORPORATED RETAIL ENGINEERING DEPARTMENT


SEAOIL PHILIPPINES, INCORPORATED ARCHITECT
SEAOIL FILLING STATION AS SHOWN A 02
22/f The Taipan Place,F.Ortigas Ave.,
Ortigas Center, Pasig City reg. no.: 0019500 issued on: 01-06-2022 LOCATION: FRANCIS GLENN YU ENGR. MICHAEL RENEE M. LUCAS
ptr no.: 0213435 issued at: pateros
manila
MOLO, ILO ILO CHIEF EXECUTIVE OFFICER RENG MANAGER
CAD/DRAWN BY:
DESIGNED BY:
REVISED BY: