1. INTRODUCTION ...................................................................................................................................................... 4
2. SUPPORTING CLAUSES ........................................................................................................................................ 4
2.1 SCOPE .............................................................................................................................................................. 4
2.1.1 Purpose ..................................................................................................................................................... 4
2.1.2 Applicability................................................................................................................................................ 4
2.2 NORMATIVE/INFORMATIVE REFERENCES .................................................................................................. 4
2.2.1 Normative .................................................................................................................................................. 4
2.2.2 Informative ................................................................................................................................................. 7
2.3 DEFINITIONS .................................................................................................................................................... 7
2.3.1 Disclosure Classification ........................................................................................................................... 8
2.4 ABBREVIATIONS .............................................................................................................................................. 8
2.5 ROLES AND RESPONSIBILITIES .................................................................................................................... 9
2.6 PROCESS FOR MONITORING ........................................................................................................................ 9
2.7 RELATED/SUPPORTING DOCUMENTS ......................................................................................................... 9
3. ARCHITECTURAL DESIGN REQUIREMENTS ...................................................................................................... 9
3.1 GENERAL.......................................................................................................................................................... 9
3.1.1 Roofs ......................................................................................................................................................... 9
3.1.2 Floors ......................................................................................................................................................... 9
3.1.3 Walls .......................................................................................................................................................... 9
3.1.4 Stairways ................................................................................................................................................. 10
3.1.5 Room and building sizing ........................................................................................................................ 10
3.1.6 Glazing .................................................................................................................................................... 10
3.1.7 Lighting and Ventilation ........................................................................................................................... 10
3.1.8 Drainage .................................................................................................................................................. 10
3.1.9 Stormwater disposal ................................................................................................................................ 10
3.1.10 Public Safety and Safety ....................................................................................................................... 10
3.1.11 Facilities for persons with disabilities .................................................................................................... 10
3.1.12 Fire Protection & Detection ................................................................................................................... 10
3.1.13 Provision for wire-ways ......................................................................................................................... 11
3.2 ARCHITECTURAL DESIGN FOR POWER STATION BUILDINGS AND ROOMS ........................................ 11
3.2.1 Power Station Battery Rooms ................................................................................................................. 11
3.2.2 Power Station Control Suites .................................................................................................................. 11
3.2.3 Power Station equipment rooms housing computer control equipment.................................................. 11
3.2.4 Commercial buildings .............................................................................................................................. 11
3.3 CORPORATE IDENTITY REQUIREMENTS .................................................................................................. 11
3.4 SECURITY DESIGN ........................................................................................................................................ 11
3.5 LANDSCAPING ............................................................................................................................................... 11
3.6 REFURBISHMENT OF EXISTING BUILDINGS ............................................................................................. 12
3.7 DRAWING STANDARDS ................................................................................................................................ 12
3.8 ROOM DATA SHEET ...................................................................................................................................... 12
3.9 DESIGN DURATION AND REVIEW ............................................................................................................... 12
3.10 SUBMISSION OF DRAWINGS TO THE LOCAL AUTHORITY .................................................................... 12
3.11 CERTIFICATES OF OCCUPANCY .............................................................................................................. 13
4. GREEN BUILDING COMPLIANCE REQUIREMENTS ......................................................................................... 14
4.1 EXISTING BUILDINGS ................................................................................................................................... 14
4.1.1 General Considerations ........................................................................................................................... 15
4.1.2 Existing Building Categories .................................................................................................................... 17
4.1.2.1 Management ................................................................................................................................... 17
4.1.2.2 Indoor Environmental Quality .......................................................................................................... 18
4.1.2.3 Energy ............................................................................................................................................. 20
4.1.2.4 Transportation ................................................................................................................................. 20
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 3 of 39
FIGURES
Figure 1: Various Green star ratings and associated outcomes for existing buildings (GBCSA) .............................. 15
Figure 2: Various Green star ratings and associated outcomes for new buildings (GBCSA) .................................... 24
Figure 3: Credit summary for new buildings (GBCSA) ............................................................................................... 26
TABLES
Table 1: Credit summary for existing buildings (GBCSA) .......................................................................................... 16
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 4 of 39
1. INTRODUCTION
This document serves as an architectural design manual for use when executing architectural designs
and green building compliance.
2. SUPPORTING CLAUSES
2.1 SCOPE
The document covers architectural design and green building compliance of structures by making
reference to various standard codes of practice, manuals and Eskom specifications that shall be
complied with when executing such designs. Architectural design and green building compliance are
multidisciplinary activities and thus require equal involvement from all interfacing disciplines throughout
the various stages of the Project Life Cycle Model.
2.1.1 Purpose
The purpose of this manual is to ensure that architectural designs and green building compliance are
executed in accordance with the relevant codes of practice, manuals and Eskom specifications thus
ensuring uniformity. The document also serves to provide a starting point for the development of Project
specifications and drawings.
2.1.2 Applicability
This document shall apply throughout Eskom Holdings Limited Divisions.
2.2.1 Normative
[1] 240-54937450, Fire Protection & Life Safety Design Standard
[2] 240-54937439, Fire Protection - Detection Assessment Standard
[3] 240-54937454, Inspection, Testing and Maintenance of Fire Protection Systems Standard
[4] 240-55864764, Chemistry Standard for Potable Water
[5] 240-56227443, Requirements for Control and Power Cables for Power Stations Standard
[6] 240-56355541, Control System Computer Equipment Habitat Requirements Guideline
[7] 240-56355808, Ergonomic Design of Power Station Control Suites Guideline
[8] 240-56364545, Structural Design and Engineering Standard
[9] 240-56737448, Fire Detection & Life Safety Design Standard
[10] 240-56737654, Inspection, Testing and Maintenance of Fire Detection Systems Standard
[11] 240-85549846 – Standard for Design of Drainage and Sewerage Infrastructure
[12] 240-8693501 – Engineering Standard for Drawing
[13] 32-245, Eskom Waste Management Standard
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 5 of 39
[14] AS/NZS 2107, Acoustics: recommended design sound levels and reverberation times for building
interiors.
[15] 240-123919938 Legionella Control and Management in Water Systems Standard
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 6 of 39
[42] SANS 10400-G (SABS 0400-G), The application of the National Building Regulations –
Part G: Excavations.
[43] SANS 10400-K (SABS 0400-K), The application of the National Building Regulations – Part
K: Walls.
[44] SANS 10400-L (SABS 0400-L), The application of the National Building Regulations – Part
L: Roofs.
[45] SANS 10400-M (SABS 0400-M), The application of the National Building Regulations –
Part M: Stairways.
[46] SANS 10400-O (SABS 0400-O), The application of the National Building Regulations –
Part O: Lighting and ventilation.
[47] SANS 10400-R (SABS 0400-R), The application of the National Building Regulations – Part
R: Stormwater disposal.
[48] SANS 10400-S, (SABS 0400-S), The application of the National Building Regulations –
Part S: Facilities for persons with disabilities.
[49] SANS 10400-W (SABS 0400-W), The application of the National Building Regulations –
Part W: Fire installation.
[50] SANS 10400-XA, The application of the National Building Regulations – Part X:
Environmental sustainability; Part XA: Energy usage in buildings
[51] SANS 10083, The measurement and assessment of occupational noise for hearing conservation
purposes
[52] SANS 10103, The measurement and rating of environmental noise with respect to annoyance and
to speech communication
[53] SANS 10114-1:2005 Interior lighting Part 1: Artificial lighting of interiors
[54] SANS 10142-1, The wiring of premises, Part 1: Low Voltage installations
[55] SANS 10160-1, Basis of structural design and actions for buildings and industrial structures Part 1:
Basis of structural design
[56] SANS 10160-2, Basis of structural design and actions for buildings and industrial structures Part 2:
Self-weight and imposed loads
[57] SANS 10161, The design of foundations for buildings
[58] SANS 10162-1, The structural use of steel, Part 1: Limit-states design of hot-rolled steelwork
[59] SANS 10162-2, The structural use of steel Part 2: Cold-formed steel structures
[60] SANS 10164-1, The structural use of masonry Part 1: Unreinforced masonry walling
[61] SANS 10164-2, The structural use of masonry Part 2: Structural design and requirements for
reinforced and pre-stressed masonry
[62] SANS 10218, Acoustical properties of buildings. Grading criteria for the airborne sound insulation
properties of buildings
[63] SANS 10400-C, The application of the National Building Regulations – Part C: Dimensions.
[64] SANS 10400-J, The application of the National Building Regulations – Part J: Floors.
[65] SANS 10400-N, The application of the National Building Regulations – Part N: Glazing.
[66] SANS 10400-P, The application of the National Building Regulations – Part P: Drainage.
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 7 of 39
[67] SANS 10400-T (SABS 0400-T), The application of the National Building Regulations – Part T: Fire
protection.
[68] SANS 11690-2, Acoustics – Recommended practice for the design of low noise workplaces
containing machinery.
[69] SANS 204, Energy efficiency in buildings
[70] SANS 50001, Energy Management Systems requirements with guidance for use
[71] SANS 50010, Measurement and Verification of energy savings
[72] SANS 656, Sound level meters.
[73] SANS 658, Integrating-averaging sound level meters
[74] SANS 1200 HC-1988
2.2.2 Informative
[75] 240-56737654, Inspection Testing and Maintenance of Fire Detection Systems Standard
[76] 331-383 Construction Buildings Concept Report (Nuclear Engineering)
[77] 331-388 ESKOM IPD(F) NUCLEAR-1 Complex 4 Admin Building Basic Design Report
[78] ASHRAE 129, Measuring Air-Change Effectiveness
[79] CIBSE TM23, Air Leakage Pressure Testing
[80] GBCSA Energy & Water Benchmarking Tool
[81] GBCSA Existing Building Rating Tool
[82] GBCSA Office Building Rating Tool
[83] GBCSA Products & Materials Sheet
[84] ISO 14001, Environmental Management Standard
2.3 DEFINITIONS
Definition Description
Accredited Professional (Green Qualified individual who can assist with the green building certification
Building) processes. Green Star SA Accredited Professionals have a comprehensive
knowledge and understanding of the Green Star SA rating system, both in
content and practical application during the building design and construction
process
Architect Suitably qualified and experienced individual registered with SACAP (South
African Council for the Architectural Profession)
Architecture The practice of the architect, where architecture means offering or rendering
professional services in connection with the design and construction of
buildings, or built environments
Base Building The base building normally includes the building's primary structure; the
building envelope in whole or part; public circulation and fire egress; and
primary mechanical and supply systems up to the point of contact with
individual occupant spaces
Competent Person Person who is qualified by virtue of his education, training, experience and
contextual knowledge to make a determination regarding the performance of
a building or part thereof in relation to a functional regulation or to undertake
such duties as may be assigned to him in terms of the National Building
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 8 of 39
Definition Description
Regulations
Design For this standard: refers to architectural design and/or green building
compliance only
Independent Commissioning External facilitator of green building commissioning activities
Agent
2.4 ABBREVIATIONS
Abbreviation Description
AS Australian Standards
ASHRAE American Society of Heating, Refrigeration, and Air-Conditioning Engineers
CIBSE Chartered Institute of Building Service Engineers
CO Carbon Monoxide
CO2 Carbon Dioxide
COC Certificate of Compliance (Electrical)
CoE Centre of Excellence
Du/ha Dwelling units per hectare
EDWL Engineering Design Work Lead
EIA Environmental Impact Assessment
EMP Environmental Management Plan
EMS Environmental Management System
EN European Standards
GBCSA Green Building Council of South Africa
GFA Gross Floor Area
GHGe Green House Gas emissions
GLA Gross Lettable Area
HVAC Heating Ventilation and Air Conditioning
IAQ Indoor Air Quality
IEQ Indoor Environment Quality
ISBN International Standards Book Number
ISO International Organisation for Standardisation
ISO International Standards Office
LDE Lead Discipline Engineer
LPS Low Pressure Services
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 9 of 39
Abbreviation Description
N/a Not applicable
NFPA National Fire Protection Association
NKP National Key Point
NZS New Zealand Standards
OHS Act Occupational Health and Safety Act
PLCM Project Life Cycle Model
PMV Predicted Mean Vote
PVC Poly Vinyl Chloride
SANS South African National Standards
TVOC Total Volatile Organic Compounds
UA Usable Area
VOC Volatile Organic Compounds
2
W/m Watts per square meter
WMP Waste Management Plan
3.1 GENERAL
All relevant SANS for architectural designs must be complied with. SANS 10400 and SANS10400-XA
Energy usage in buildings, The application of the National Building Regulations comprises of various
Parts that are to be adhered to when executing architectural designs. Designs should be practical,
functional, feasible and aesthetically pleasing.
3.1.1 Roofs
All roofs shall comply with SANS 10400, Part L and be reviewed by a structural engineer for acceptance.
3.1.2 Floors
All floors and associated elements shall comply with SANS 10400, Part J and be reviewed by a
structural engineer for acceptance.
3.1.3 Walls
All walls shall comply with SANS 10400, Part K and be reviewed by a structural engineer for acceptance.
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 10 of 39
3.1.4 Stairways
All stairways shall comply with SANS 10400: Part M, Eskom Standard Stair and Handrail details: 0.00/
2901 and be reviewed by a structural engineer for acceptance.
3.1.6 Glazing
Glazing and fenestration also to conform to SANS 10400 XA and SANS 204
Lighting and ventilation shall comply with SANS 10400, Part O. It should be stressed that although
natural lighting and ventilation can be allowed for by the Architect, it is the responsibility of the Electrical
and Low Pressure Services disciplines to ensure that lighting and ventilation is adequately designed for,
considering natural and artificial type lighting and ventilation. It is thus recommended that the Electrical
and Low Pressure Services disciplines work in conjunction with the Architect for natural lighting and
ventilation considerations.
3.1.8 Drainage
All sewage and drainage shall comply with SANS 10400, Part P. Such shall be reviewed by a civil
engineer for acceptance.
It should be stressed that although the Architect considers fire protection in his design of architectural
components (emergency escape routes, quantity and width of staircases, panic ironmongery, fire water
tap off to building, fire sealing of openings, fire doors, fire water drainage, hydrant & hose reel positions),
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 11 of 39
it is the responsibility of the relevant discipline i.e. Low Pressure Services to ensure that a structure is
adequately designed for fire safety. The fire rating and building occupancy for all buildings shall be
advised by Low Pressure Services to ensure that the architectural design is compliant for the buildings
purpose. Fire detection specification and emergency lighting is the responsibility of the Controls and
Instrumentation and Electrical disciplines respectively.
3.5 LANDSCAPING
Landscaping should be designed around buildings to create an aesthetically pleasing environment whilst
not affecting the designed stormwater management for the area. Landscaping should preserve and
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 12 of 39
enhance desirable natural features e.g. topography, architectural features of surrounding buildings whilst
also providing natural shade.
The selection of plants, flowers, trees and shrubs to support the landscaping design must be approved
by the relevant stakeholders and Eskom Environmental department.
Buildings exempted from these regulations in section 2, subsection 5 of the mentioned standard are the
following:
“(a) any place as defined in section 1 of the National Key Points Act, 1980 (Act No.102 of 1980) -
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 13 of 39
(i) that has been declared a National Key Point in terms of section 2 of the said Act; or
(ii) in respect of which the Minister of Defence has certified that it will be declared a National Key
Point under the said section 2 of that Act;”
Proof of the facility having a National Key Point status must be submitted to the local authority.
However, it should be clearly noted that for NKP facilities, there is still a legal requirement to submit
drawing plans to the local authority to the level of depicting building floor space such that the local
authority can calculate the rates and taxes bill. Further, regardless of the facility being declared a
National Key Point, fire rationale and plans are required by the local authority (for approval by the Fire
Chief) from a safety perspective.
“(2) Any person licensed or authorized by a local authority to carry out the installation, alteration or
repair of any electrical wiring connected or of which connection is desired with the electrical supply
or distribution works of such local authority or any statutory body, shall, at the request of the owner
of a building of which the erection has been completed or of any person having an interest therein
or of the local authority, issue a certificate if he is satisfied that the electrical wiring and other
electrical installations in such building are in accordance with the provisions of all applicable laws.
(2A) Upon completion of the erection or installation of -
(a) the structural system; or
(b) the fire protection system; or
(c) the fire installation system,
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 14 of 39
of any building the person appointed to design such system and to inspect the erection or installation,
shall submit a certificate to the local authority indicating that such system has been designed and
erected or installed in accordance with the application in respect of which approval was granted in terms
of section 7.”
An appointed competent person shall ensure that all documents and drawings required by the local
authority are submitted timeously as per the National Building Regulations and Building Standards Act
103 of 1977 and SANS 10400, The Application of the National Building Regulations.
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 15 of 39
Buildings can be rated from 1 Star to 6 Star based on the performance, policies and plans for existing
buildings unlike the Office Tool for new buildings which only allows for certification rating from 4 star to 6
star.
Figure 1: Various Green star ratings and associated outcomes for existing buildings (GBCSA)
Site planning - This includes sustainable site planning, for example during the end of life or removal of
one building or multiple buildings, other buildings can still be built or assembled at the same location.
Energy - This includes aspects which would reduce power consumption through the use of natural light,
ventilation, thermal insulation and correct orientation of the building. Appropriate selection of HVAC
equipment and building system controls are critical to the efficiency of any building.
Material - Green building compliance can minimize the environmental impact by correctly selecting low
carbon footprint materials, salvaged materials, renewable materials, recycled materials and materials
sourced close to the site.
Water - This includes aspects of reduction of water consumption and/or potable water consumption. The
Energy and Water Benchmarking tool plays a significant role in identifying the eligibility for pursuing
these credits.
Energy and Water Benchmarking Tool
This tool will be used to quantify the energy and water savings so as to ensure that the credits are
achievable prior to certification.
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 16 of 39
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 17 of 39
4.1.2.1 Management
For this tool the management section deals with the management throughout the life-span of the
building, as buildings can under-go refurbishments, retro-fits and tenant changes. Consideration is given
to the policies and procedures as well as targets and strategies for operating and maintaining the
building. This includes educating the occupants on the features of the building. This is an on-going
process which is managed over time.
Certified Buildings
This credit aims to reward the buildings that have shown environmental achievement through other
GBCSA tools.
Accredited Professional
This credit aims to recognise the involvement of qualified individuals who can assist the certification
processes.
Building Management
The aim of this credit is to recognise management and operating processes and procedures used to
optimise building environmental performance, such as:
a) Building Operations Manual;
b) Building User’s Guide;
c) Maintenance Management; and
d) Life Cycle Maintenance Programme.
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 18 of 39
c) Building audits and cleanliness audits associated with health related incidents that can or may
occur.
Green Leasing
This credit aims to recognize and encourage collaboration between Owner & Tenant to manage and
operate the building in an environmentally sustainable manner.
Points can be achieved where mutual agreements can be signed outlining:
a) Building Owner/Tenant fit-out and alterations;
b) Type of signed agreement and size of GLA;
c) Management & operations; and
d) Type of agreements and GLA.
And
Advanced monitoring strategy:
d) As above and to include online and live monitoring; and
e) Trending, Logging etc.
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 19 of 39
Lighting Comfort
This credit recognises operational practices that provide occupants with a high degree of lighting
comfort.
Considerations include:
a) Luminaire ballasts;
b) Lighting comfort (work stations);
c) Colour rendering index;
d) Colour temperature;
e) Glare;
f) OHS Act; and
g) SANS 10114-1.
Thermal Comfort
This credit aims to recognise operational practices that monitors and maintains a high level of thermal
comfort for building occupants. This refers to mechanical and naturally ventilated areas where points can
be awarded for:
a) Periodical measurement of humidity;
b) Assessment of problems prevalent due to high air speed and radiant heat (Audit); and
c) Occupant feedback (survey).
Acoustic Quality
This credit aims to encourage operational practices that monitor and maintain indoor ambient noise
levels from building services and all outside sources at an appropriate and comfortable level, to mitigate
problems created by transference of sound to adjacent spaces, and to control the noise impact from the
operations of the existing building on the immediate surrounding environment.
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 20 of 39
4.1.2.3 Energy
The focus is to reduce the energy consumption in turn reducing the greenhouse gas emissions while
looking at alternate forms of energy. This also involves metering and monitoring to focus on the more
energy intensive areas.
4.1.2.4 Transportation
This credit aims to measure and assess transportation modes of regular building occupants and
promote/encourage green travel plans for commuting and as a result reduce pollution and land
development impacts from automobile use.
Alternative Transportation
Points in this credit can be achieved through;
a) Transportation modes survey;
b) Green Travel Plan (GTP) for regular occupants and visitors; and
c) Follow-up on surveys.
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 21 of 39
A comprehensive template is provided in the GBCSA Existing Building Technical Manual (Informative
references).
4.1.2.5 Water
The Water category assesses and rewards reductions in potable water use through efficient building
services, water reuse and substitution with non-potable water sources, such as rainwater or greywater.
Potable Water
The aim of the credit is to recognise efficient potable water use associated with building operations, thus
reducing the burden on potable water supply and wastewater systems.
2 compliance paths are suggested for determining benchmarks and improvements:
a) GBCSA Water Benchmarking Tool; or
b) Establish historic baseline for efficiency comparison.
In making use of non-potable water sources or using impacted potable water due consideration must be
given to the elements contained in the water source to ensure that it has no impact on any equipment or
infrastructure of pipework. In the case of were impacted water (reused water, rainwater, greywater) is
treated for potable purposes then the water produced and distributed by such a treatment system shall
comply with the requirements of 240-55864764, Chemistry Standard for Potable water. The design of the
water treatment system and the provision of advice on the use of non-potable or impacted water in
systems will be informed by the Chemical CoE.
4.1.2.6 Materials
The Materials category focuses on the materials that go into – or come out of – a building during the
operational phase of its lifecycle. These are the materials that are required for building operations, not
the materials from which the building is constructed. The Materials credits assess issues such as
sustainable procurement and purchasing (materials in) and the management of waste (materials out).
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 22 of 39
b) Waste stream audit of ongoing consumables and development of an operational waste and
materials management plan;
c) Waste to landfill diversion: Operational waste and materials;
d) Waste to landfill diversion: Movable and/or electronic goods; and
e) Waste to landfill diversion: Construction waste – churn and alterations.
Grounds-Keeping Practices
The aim of this credit is to encourage environmentally sensitive landscape, hard surfaces and building
exterior maintenance practices that reduce the environmental impact and improve ecological value.
Points are awarded for creating and implementing the following:
a) Landscape management plan;
b) Hard surfaces and building exterior management plan;
c) Integrated pest management plan; and
d) Site maintenance plans.
4.1.2.8 Emissions
The Emissions category focuses on reducing pollutants from buildings and building services (excluding
greenhouse gas emissions which are dealt with in the Energy category) both to the atmosphere and
local waterways, on site and beyond site boundaries.
Refrigerants
The aim of this credit is to encourage operational practices that minimise the environmental impacts of
refrigeration equipment.
Points can be achieved by identifying;
a) Ozone depleting potential; and
b) Global warming potential.
Legionella
The aim of this credit is to recognise and encourage implementation and utilisation of a water
management process with the intention to minimise risks associated with Legionnaires’ disease.
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 23 of 39
The implementation method for the risk management process and for control of legionella in water
systems can be found in 240-123919938 Legionella Control and Management in Water Systems.
4.1.2.9 Innovation
This credit recognises the building for exceeding GBCSA practices. There are 3 categories for reward:
a) Innovative strategies and technologies;
b) Exceeding GBCSA benchmarks; and
c) Environmental initiatives.
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 24 of 39
The green building categories are the same as for existing buildings, but with varying scores:
Figure 2: Various Green star ratings and associated outcomes for new buildings (GBCSA)
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 25 of 39
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 26 of 39
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 27 of 39
4.2.2.1 Management
The management category ensures that the planning and operation of a building is carried out by trained
professionals and that each green measure implemented is done so according to the standards set.
Commissioning Clauses
Management must be informed on the green design goals for the building, including energy and
environmental strategy, details on monitoring of targets, and building services. Management must be
able to operate and maintain the green features and systems.
Building Tuning
Management should be involved with the verification that systems perform optimally, the optimisation of
time schedules and alignment of operation of systems. Management is involved in putting together a
Building Tuning Report. Management should be part of the building tuning team.
Environmental Management
The contractor must implement a comprehensive, project-specific Environmental Management Plan
(EMP) for the construction works in accordance with those requirements which form part of the
Environmental Impact Assessment (EIA). The Contractor should also have a valid ISO 14001[84]
Environmental Management System (EMS) accreditation prior to and throughout the duration of the
project.
Waste Management
Construction management practices should incorporate the minimisation of the amount of construction
waste earmarked for disposal. The contractor should implement a Waste Management Plan (WMP) and
retain waste records and issues which form part of quarterly reports to the building owner. A percentage
greater than 30 % of all demolition and construction waste should be of such a nature that it may be
reused or recycled.
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 28 of 39
Airtightness Testing
Measures to reduce air leakage in buildings, verified through relevant test methods, and should be
implemented to achieve an adequate level of airtightness. An air test will be carried out on the completed
building in accordance with CIBSE TM23:2000 [79] to assess leakage rates. A leakage rate of less than
15 m3/ hour/m² should be achieved at a relative pressure of 50 Pa. The testing process should allow for
corrective sealing procedures and re-testing if required. This credit shall be the responsibility of the Low
Pressure Services discipline.
Ventilation Rates
Ventilation designs will provide for sufficient amounts of suitable quality outside air to counteract build-up
of indoor pollutants. Where buildings are to be mechanically ventilated:
Outside air is provided at rates greater than the requirements of SANS 10400-O [46] and the position of
intakes must be within the prescribed minimum distances from exhaust outlets for 95% of the occupied
space.
Daylight
This section encourages building designs to provide good levels of daylight for building users. Points are
awarded depending on the nominated area that has a daylight factor of at least 2% or daylight
illumination of at least 250 lux as measured at the floor level under a uniform design sky.
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 29 of 39
b) Where blinds or screens are fitted on all glazing and atria as a base building provision, and meet the
following criteria:
Eliminates 95% of direct sun penetration;
Have a visual light transmittance (VLT) of <10 %; and
Can be controlled by all affected occupants within each floor or area.
External Views
Designs that provide occupants with a visual connection to the external environment can be awarded
points if a significant portion of the nominated area has a direct line of sight to the outdoors or into an
adequately sized and day-lit atrium.
Thermal Comfort
This section will reward buildings that achieve a high level of thermal comfort. Points are awarded where
a high level of thermal comfort is achieved for 95% of the nominated area which is naturally and
mechanically ventilated. Points are also awarded if the Predicted Mean Vote (PMV) levels are calculated
in accordance with ISO: 7730[33].
Hazardous Materials
This credit aims to recognise actions taken to reduce health risks to the buildings occupants from the
presence of hazardous material through comprehensive hazardous materials survey.
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 30 of 39
Formaldehyde Minimisation
Formaldehyde is a colourless gas with a pungent odour having the systematic name methanol. This
category encourages and recognises the specification of products with low formaldehyde emission
levels. Points are awarded where all composite wood products (including exposed and concealed
applications) and any other formaldehyde containing products either have low formaldehyde emissions
or contain no formaldehyde.
Mould Prevention
Designs of services that eliminate the risk of mould growth and its associated detrimental impact on
occupant health are required. Points are awarded where it is demonstrated that for 95% of the
nominated area the mechanically air-conditioned ventilation system maintains humidity levels at no more
than 60% relative humidity in the occupied space and no more than 80% relative humidity in the supply
ductwork. This credit shall be the responsibility of the Low Pressure Services discipline.
Exhaust Riser
Dedicated exhaust riser that is used to remove indoor pollutants from printing and photocopy rooms are
awarded points, where a reserved room for print/ photocopy is provided and all print/ photocopy room(s)
are exhausted to a dedicated exhaust riser. The exhaust riser must have the following characteristics:
a) Provide at least 3 air changes per hour for 100% of the print / photocopy room(s); and
b) The exhaust system is not recycled and is discharged outside of the building.
This credit shall be the responsibility of the Low Pressure Services discipline.
4.2.2.3 Energy
In order to achieve green efficiency it is required to minimise the quantity of energy used and emission
given off during the on-going operation of the buildings. The sections below define the measures to be
taken in order to be energy efficient.
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 31 of 39
Energy Sub-metering
Electrical energy sub-metering will be able to facilitate on-going management of electrical energy
consumption and should be considered for installation for this credit. Points are awarded where it is
demonstrated that sub-metering is provided for substantive energy uses within the building, (all energy
uses of 100 kVa or greater), including separate meters for all tenancies. There must also be an effective
automated mechanism for monitoring energy consumption data. Additionally points are awarded where it
is demonstrated that sub-metering is provided separately for lighting and separately for power for each
floor. For the additional point to be awarded there must also be an effective automated mechanism for
monitoring energy consumption data from all energy sub-meters.
This credit shall be the responsibility of the Electrical discipline.
Lighting Zoning
This refers to lighting practices that offer greater flexibility for light switching which makes it easier to light
only occupied areas where required. Points are awarded for the following:
a) All individual or enclosed spaces can be switched on/ off individually;
b) The size of individually switched lighting zones does not exceed 100m² for 95% of the unoccupied
area; and
c) Switching is clearly labelled and easily accessible by building occupants.
An additional point is awarded where the above is ensured and it is demonstrated that an individually
addressable lighting system is provided for 90% of the unoccupied area.
This credit shall be the responsibility of the Electrical discipline.
4.2.2.4 Transport
The transport category encourages the careful planning of traffic flow and the use of different modes of
transport which minimise emissions that negatively impact the environment.
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 32 of 39
Where the share of staff parking is greater than 30% of all parking spaces, a minimum of 3% of staff
parking spaces should be dedicated solely for the use by car-pool and car-share vehicles, and all of
these must be in preferred parking locations. Signage and labelling must be provided for the intended
users.
Cyclist Facilities
The use of bicycles by staff and visitors is encouraged.
Points are available if it can be demonstrated that safe, convenient cycling routes are provided between
on-site buildings and the adjacent street network. Points are achievable as follows:
a) where cyclist facilities are provided for 3% of the building staff and bicycle storage is provided for 3
% of daily visitors; and
b) where cyclist facilities are provided for 6% of the building staff and bicycle storage is provided for 6
% of daily visitors.
Further, a transport information point having a dedicated area provides information about local public
transport, cycling and walking facilities. The dedicated area must:
d) Be in a location that is accessible to all building users, ideally in a main reception or lobby area; and
e) Be signposted at its location and throughout appropriate areas of the site indicating its existence,
purpose and location.
The data at the information point is presented using a lockable noticeboard or electronically.
Local Connectivity
Points can be awarded for identifying and demonstrating that safe, well-lit, dedicated pedestrian facilities
are provided between the development and the adjacent street network. Points are achievable as
follows:
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 33 of 39
a) for facilities such as banks, supermarkets and restaurants being located less than 400m from the
development;
b) for a minimum gross density of 35 du/ha, for the entire area within 400m of the development.
Electric Vehicles
The electric vehicle is slowly becoming accessible to the public, as the National Utility, it will be
imperative to include facilities that promote the use of electric vehicles. This can be executed through the
adoption of Electric Vehicle Charging Stations, ultimately increasing electricity revenue as more charging
stations will increase adoption as the economics and environmental factors of EVs are fast becoming
greatly attractive.
4.2.2.5 Water
Water is a resource which must be used sparingly. To achieve the objective of minimising the quantity of
water consumed during the operation of the buildings, various measures mentioned below are required
to be applied.
Water Meters
This credit looks at the building reticulation system monitoring and managing water consumption
throughout building. Points are awarded where:
a) it is demonstrated that water meters are installed for all major water uses in the development;
b) there is an effective automated mechanism for monitoring water consumption data, which performs
leak detection on the reticulation system; as well as the development of a metering and verification
strategy for the project; and
c) it is demonstrated that solenoid valves are installed on the water supply to each ablution area in the
building. The flow of water through the water supply is controlled by a link to either:
Infra-red movement detectors within each toilet facility, or
Sensors or switches placed at or on entry doors to each facility.
Landscape Irrigation
Points are awarded
a) where, potable water consumption for landscape irrigation has been reduced by 50%; and
b) where, potable water consumption for landscape irrigation has been reduced by 90% or plants
chosen require no additional watering once established (i.e. xeriscaping).
If there is no landscaping, or the total landscaping represents less than 1% of the site area, these points
are ‘Not Applicable’ and are excluded from the Points Available used to calculate the Water Category
Score.
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 34 of 39
4.2.2.6 Materials
The materials required for the construction of the structure are sourced such that there is a minimal long
term impact on the environment. This is achieved by ensuring that where possible recycled material
could potentially be used and that virgin material used is manufactured, transported and stored using the
“greenest” approach achievable.
Building Re-use
Points are awarded where a proportion of the total existing façade of the building, by vertical area, is
reused and where a proportion of the existing major structure, by gross building volume, is reused.
Where the site contained no buildings at the time of purchase or the total GFA of the original building(s)
is less than 20% of the GFA of the new building that replaces it, this credit is ‘Not Applicable’ and is
excluded from the Points Available, used to calculate the Materials Category Score.
Re-used Materials
Points are awarded where at least 1% of the project’s total contract value is represented by reused
products/materials and where 90% of the UA (Usable Area) of the project is delivered as any
combination of shell and core or integrated fit-out.
This credit excludes materials specifically addressed by other credits (i.e. steel, concrete, PVC and
timber); neither does it address the reuse of the original building(s) on the site (addressed in Mat-2
‘Building Reuse’).
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 35 of 39
Concrete
This credit looks at the reduction of embodied energy and resource depletion occurring through the use
of concrete in designs. Points are awarded where the project has reduced the absolute quantity of
Portland cement, as an average across all concrete mixes, by substituting it with industrial waste
product(s) and/ or oversized aggregate as follows:
a) 30% for in-situ concrete, 20% for precast concrete and 15% for stressed concrete; or
b) 60% for in-situ concrete, 40% for precast concrete and 30% for stressed concrete and
c) 10% of all aggregate used for structural purposes is recycled (Class 1 recycled concrete aggregate
in accordance with Australian standard HB155-2002 [10] or slag aggregate); and
d) No virgin aggregates are used in non-structural concrete uses (e.g. building base course, sub-grade
to any car parks and footpaths, backfilling to service trenches, kerb and gutter).
Steel
The use of virgin steel is kept to a minimum so as to reduce the embodied energy and resource
lessening associated with its use. Points are awarded if in a predominantly structural steel building, the
average post-consumer recycled content of the structural steel, by mass, is at least 24% (60% of the
structural steel has a recycled content of 40%).
If the building is predominantly a reinforced concrete building, the average post-consumer recycled
content of the steel reinforcing, by mass, must be at least 54% for the point to be achieved (60% of the
steel reinforcing by mass has a recycled content of 90%).
Additional points are awarded where the average post-consumer recycled content of all major steel
applications, (total of structural steel, steel reinforcing, and building envelope), by mass is at least 54%
(60% of the total steel has a recycled content of 90%).
PVC Minimisation
This refers to the use of Poly Vinyl Chloride (PVC) products in buildings, considering points awarded
where 30% of the total cost of PVC content is reduced through replacement with alternative materials.
Sustainable Timber
This credit aims to encourage and recognise the specification of reused timber products or timber that
has certified environmentally-responsible forest management practices.
Dematerialisation
This credit considers the design process such that the structural systems of the buildings produce a net
reduction in the total amount of material used. Points are awarded where it is demonstrated that when
compared to a structure with conventional steel, concrete or timber framing:
The building’s structural requirements and integrity have been achieved using 20% less structural steel
(by mass), or
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 36 of 39
The above is achieved without changing the load path to other structural components.
Local Sourcing
Environmental advantages are gained, in the form of reduced transportation emissions, by using
materials and products that are sourced within close proximity to the site. Points are awarded as follows:
a) where 20% of the total contract value is represented by materials or products (used in the
construction of the project) that have been sourced from within 400 km of the site; or
b) where 10% of the total contract value is represented by materials or products (used in the
construction of the project) that have been sourced from within 50 km of the site.
Only materials or products that are permanently installed in the building are eligible and must have been
extracted, harvested, recovered, as well as manufactured within the above noted radii of the site in order
to qualify for the credit.
Mechanical, electrical and plumbing components and specialty items such as elevators and equipment
are to be excluded from the calculations of both local materials and total contract value.
Topsoil
Points are awarded where all topsoil impacted by the construction works is separated and protected from
degradation, erosion or mixing with fill or waste. The following criteria must be met:
a) Protected topsoil is spread over the relevant impacted areas to a minimum depth of 200 mm and a
maximum depth of 600 mm;
b) At least 75% of all protected topsoil ('free air' volume) remains on site. Any remaining protected
topsoil is transported to the nearest land holding of the same soil classification that requires
rehabilitation and is deposited under the supervision of an ecologist; and
c) Where protected topsoil remaining on site is used productively.
Re-Use of Land
Points are awarded as follows:
a) If the project is a refurbishment or a building extension; or
b) If at the time of the site purchase, 75% of the site had been previously built on.
An additional point is awarded if the site is located within a municipally approved urban edge.
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 37 of 39
This credit is ‘Not Applicable’ for projects that are refurbishments or building extensions, and is excluded
from the Points Available, used to calculate the Land Use & Ecology Category Score.
4.2.2.8 Innovation
This credit recognises the building for exceeding GBCSA practices. Points are available in the following
3 categories:
d) Innovative strategies and technologies;
e) Exceeding GBCSA benchmarks; and
f) Environmental initiatives.
5. AUTHORISATION
This document has been seen and accepted by:
Name & Surname Designation
Dawie Naude Substation Engineering
Denise Govender Structural and Civil Design CoE, Civil Engineer
Francisco De Freitas Control and Instrumentation CoE
Galia Dudenska Structural and Civil Design CoE, Senior Manager
Justin Varden Chemical CoE
Kamir Lala Structural and Civil Design CoE, Civil Engineer
Navash Brigman Electrical CoE
Phera Rakeketsi Electrical CoE
Sibonelo Sibiya Architect Structural Design CoE
Mapula Majola Manager: Engineering
Dieter Huppe Manager: Engineering
Mbali Mtshali LPS CoE
Anasen Pillay; LPS CoE
Zama Luswazi Manager: LPS CoE
Marlize Andre; LPS CoE
Justin Padiachy Engineering Structural Design CoE
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 38 of 39
6. REVISIONS
Date Rev. Compiler Remarks
November 2012 0 CS Pretorius Draft Document for review created from 200-26680
June 2013 1 CS Pretorius Final document for Publication
August 2014 1.1 D Govender & K Lala Revision of document by the assigned Work Group:
Conversion of standard into design manual and addition of
green building compliance requirements
October 2014 1.2 D Govender & K Lala Draft Document for Comments Review (Rev 1.2)
October 2014 1.2 D Govender Comments incorporated
October 2014 2 D Govender Final Document for Authorisation and Publication (Rev 2)
March 2018 2.1 K Lala Draft Document for Comments Review process in SC
March 2018 2.2 K Lala Final Draft for Business Review Process
March 2018 2.3 K Lala Final Draft after Business Review Comments concluded
April 2018 3 K Lala Final Rev 3 Document for Authorisation and Publication
7. DEVELOPMENT TEAM
The following people were involved in the development of this document:
Kamir Lala
8. ACKNOWLEDGEMENTS
None
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.
Architectural Design and Green Building Compliance Manual Unique Identifier: 240-56364535
Revision: 3
Page: 39 of 39
APPENDIX A
CONTROLLED DISCLOSURE
When downloaded from the EDMS, this document is uncontrolled and the responsibility rests with the user to ensure it is in line
with the authorised version on the system.