Automated Distillation Tester

ad-7
Ergonomic , Robust and Versatile
ad-7 automatically performs distillation test of petroleum products as well as narrow boiling range samples.
10.4 inch LCD with touch panel has been adopted for easy and intuitive operation.
Peltier system is employed for cooling/ heating of the condenser and receiver cylinder compartment.
Robust design for continuous use.

User-friendliness
● 10.4 inch(*) Color LCD.* 4 times larger than previous model.
● Intuitive operation by Touch Panel.
● Advanced data management software; tdas ( Tanaka Data Acquisition System ).

Safety
● Fire Containment system: Heater shuts down when ultraviolet sensor detects a fire,
and CO2 gas flows into the heater compartment (if connected to CO2 source).
● Flask Catcher reduces the risk of breaking vapor tube of flask.
● Overheat protection: Heater shuts down automatically at the upper end of the temperature scale.

Versatility
● 200 test modes
● 5,000 test results
● RS-232C, USB port, Ethernet
Automated Distillation Tester

Specifications
ad-7
Standard JIS K 2254, JIS K 0066, JIS K 5601-2-3, JIS K 2435-1/2/3 ASTM D86-12, ASTM D850, ASTM D1078,
ISO 3405, ISO 918, IP123, IP195, GOST2177

Test ranges Selectable from 0 ℃ to 300/450 ℃ (fuel oil) or 0 ℃ to 200/450 ℃ (ASTM D850,
D1078 with optional accessories)

Program control Sequence control by microcomputer

Display TFT-LCD 10.4 color touch-screen with universal design GUI

Printer Built-in, thermal type (Paper width:80 mm, Print width:72 mm)

Barometric correction Automatic correction by barometric pressure sensor or manually input

Temperature unit 0.1 ℃ or 0.2 ̊F

Temperature sensor Vapor: Pt100


Condenser: Pt100
Receiver room: Pt100

Heater 24 V 600 W low mass and low voltage heater, spiral type

Heater cooling system Forced air cooling by propeller fan

Condenser Brass made tube


Note: Stainless tube for corrosive sample (special order)

Condenser temperature control Electronic cooling & heating by Peltier coolers : 0 ∼ 69.9 ℃

Receiver temperature control Electronic cooling & heating by Peltier coolers : 10 ∼ 50 ℃

IBP detection Photoelectric detection by Infrared LED and phototransistor

Liquid level detection Photoelectric detection by Infrared LED and phototransistor


Distillation rate: 4.5 % /min at factory (Selectable from 2 to 9 % with 0.5 % increment)
Control method : PID Control

Test mode Up to 200 test modes can be recorded

Dry point detection Manual detection by visual confirmation


Note: Or automatic detection by dry point sensor (Option)

Safety features (1) Overheat protection activates at the upper end of the temperature scale.
(2) Self-diagnosis for sensor break, test condition and incorrect operations.
(3) Automatic fire detection system
Note: Heater shuts down, activates audible alarm and displays notice.
Note: CO2 gas flows into the heater compartment if connected to CO2 line.

Communication port RS-232C x 1ch:for LIMS


Ethernet x 1ch:for tdas or LIMS
USB x 1ch:for Flash Memory or firmware update

Data storage Up to 5,000 test results can be stored.

Power source AC 100V - 240 V 50 / 60 Hz 15 A

Size ( W x D x H ) 430 x 520 x 710 mm (16.9 x 20.5 x 28 )

Weight 55 kg (121.25 lb)

Specifications subject to change without prior notice.


201608P

Distributed in North America by:


CANNON Instrument Company®
2139 High Tech Rd. State College, PA 16803 USA
Phone: 814-353-8000 fax: 814-353-8007