Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

MHP 02 SD Ulr 04 15 369 375

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

REV / IND DATE PREPARED CHECKED ENDORSED DESCRIPTION

SECTION A
ULR-04-15-373

CL DT-3

CF
RD
KEY PLAN

DA
M
10 288 Ø13@150
N
T-3
E LD
U NN
230 IO NT
8 9 Ø36@225(Alt.) 5(Ty RS

)
p.) E
DIV
700

0
70
p.)

)
5(Ty 9 8 Ø36@225(Alt.)

0+
230

50
-1

6
DT UG

0+
0
PL

00

60
0+1

0+
50

0
0+1

55
2 2 Ø36@225(Alt.)

3.7
0
00

68.9

0+
43
0+2

0
50

0+

50
R65
0+ 3
NCT

0+2

0+
2

00

0
1.0
0+3

50

45
0+400
0+3

0+
LINING TYPE DT3-E1

3068000
7500

1124500

R8
200
R7
500 NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.
2 1 Ø36@225(Alt.) 1 2 Ø36@225(Alt.) 2. THE DRAWING IS APPLICABLE TO DIVERSION TUNNEL DT-3.
4. LINING TYPE DT3-E1 AND DT3-E2 DIFFER FROM EACH OTHER IN TERMS OF EXCAVATION
15000 PROFILE AND INSTALLED ROCK SUPPORT.
5. LINING TYPE DT3-E1 SHALL BE INSTALLED IN REACHES WHERE ROCK SUPPORT
700 3250 4250 7500 700 TYPE RS-I, RS-II, OR RS-III HAS BEEN PROVIDED.
7 6 Ø36@225(Alt.) 6. FOR LINING PLAN & PROFILE REFER TO DWG. NO. MHP-02-SD-ULR-04-13-011~012.
16400

7. THE CONCRETE USED FOR CONSTRUCTION OF CONCRETE LINING SHALL BE


CLASS 'D' CONCRETE WITH MINIMUM COMPRESSIVE STRENGTH OF 25MPa AT 28 DAYS.
8. THE CLEAR COVER TO REINFORCEMENT SHALL BE 100mm.
°
41.2
6 7 Ø36@225(Alt.) 9. ALL REINFORCEMENT SHALL BE STAGGER SPLICED UNLESS DIRECTED
OTHERWISE BY THE ENGINEER.
R1245 10. STEEL REINFORCEMENT SHALL BE DEFORMED HIGH YIELD STEEL BARS CONFORMING
0 TO ASTM A615M, GRADE 60 [420] HAVING A MINIMUM YIELD POINT STRESS OF 420MPa.
11. CONCRETE PLACEMENT OF WALLS AND CROWN MUST BE COMPLETED WITHOUT
4820

PRESENCE OF COLD JOINTS.


12. THE SPACING OF CONSTRUCTION JOINTS IN LONGITUDINAL DIRECTION
SHALL NOT EXCEED 12m.
13. TRANSVERSE JOINTS BETWEEN ADJACENT LINING SECTIONS ARE STANDARD
CONSTRUCTION JOINTS.
14. SCALE:
CONSTRUCTION JOINT
7500

2 2 Ø36@225(Alt.) 0 500 1000 1500 2000 2500 mm

2 2 Ø36@225(Alt.)
4 3 Ø36@225(Alt.)
MDCG-IFC-DIV-2011-R3 DIVERSION TUNNEL DT-1/DT-3 TUNNEL LINING LAYOUT PLAN & PROFILE
DIVERSION TUNNEL DT-3 OUTLINE OF CONCRETE LINING
MHP-02-SD-ULR-04-14-221~226
(CH0+063.58 TO CHO+451.00)

p.)
) DIVERSION TUNNEL DT-3 CONCRETE LINING TYPE DT3-E1

(Ty
10 318 Ø13@150 MDCG-IFC-DIV-2018B-R0

05
3 4 Ø36@225(Alt.) (FOR RS-I, RS-II & RS-III) CONCRETE OUTLINE & REINFORCEMENT

23
Dwg. No. DRAWING TITLE
2305(Typ.) 2305(T REFERENCE DRAWINGS
)

yp.)
700

EMPLOYER:
PAKISTAN
5 5 Ø36@225(Alt.) WATER AND POWER DEVELOPMENT AUTHORITY
10 68 Ø13@150 CONSULTANT:
5118 5118
10236

CONTRACTOR:

CGGC-DESCON Joint Venture DESCON

MOHMAND HYDROPOWER PROJECT


DESIGNED Song Jian 2023.11.24
DIVERSION TUNNEL-3
CHECKED Peng Xiaochuan 2023.11.24
REINFORCEMENT OF CONCRETE LINING
EXAMINED Wu Jinxu 2023.11.24
CH0+368.90 TO CH0+451.00 (1/7)
VERIFIED Yang Hai 2023.11.24
APPROVED He Zhoushi 2023.11.24 SHOP DRAWING DESIGN CIVIL WORKS SECTION
SCALE SEE DRAWING DRAWING No. MHP-02-SD-ULR-04-15-369-D1
REV / IND DATE PREPARED CHECKED ENDORSED DESCRIPTION

SECTION B
ULR-04-15-373

CL DT-3

11 11a 144+144 Ø13@150(Alt.)

8 9 Ø36@225(Alt.) 230
5(Ty

)
p.)
700
yp.)

)
5(T 9 8 Ø36@225(Alt.)
230

2 2 Ø36@225(Alt.)

NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.
2. THE DRAWING IS APPLICABLE TO DIVERSION TUNNEL DT-3.
4. LINING TYPE DT3-E1 AND DT3-E2 DIFFER FROM EACH OTHER IN TERMS OF EXCAVATION
PROFILE AND INSTALLED ROCK SUPPORT.
5. LINING TYPE DT3-E1 SHALL BE INSTALLED IN REACHES WHERE ROCK SUPPORT
7500

TYPE RS-I, RS-II, OR RS-III HAS BEEN PROVIDED.


6. FOR LINING PLAN & PROFILE REFER TO DWG. NO. MHP-02-SD-ULR-04-13-011~012.
7. THE CONCRETE USED FOR CONSTRUCTION OF CONCRETE LINING SHALL BE

R8
200
CLASS 'D' CONCRETE WITH MINIMUM COMPRESSIVE STRENGTH OF 25MPa AT 28 DAYS.
R7 8. THE CLEAR COVER TO REINFORCEMENT SHALL BE 100mm.
50 9. ALL REINFORCEMENT SHALL BE STAGGER SPLICED UNLESS DIRECTED
0
OTHERWISE BY THE ENGINEER.
2 1 Ø36@225(Alt.) 1 2 Ø36@225(Alt.)
10. STEEL REINFORCEMENT SHALL BE DEFORMED HIGH YIELD STEEL BARS CONFORMING
TO ASTM A615M, GRADE 60 [420] HAVING A MINIMUM YIELD POINT STRESS OF 420MPa.
15000 11. CONCRETE PLACEMENT OF WALLS AND CROWN MUST BE COMPLETED WITHOUT
PRESENCE OF COLD JOINTS.
700 3250 4250 7500 700
7 6 Ø36@225(Alt.) 12. THE SPACING OF CONSTRUCTION JOINTS IN LONGITUDINAL DIRECTION
SHALL NOT EXCEED 12m.
16400

13. TRANSVERSE JOINTS BETWEEN ADJACENT LINING SECTIONS ARE STANDARD


CONSTRUCTION JOINTS.
° 14. SCALE:
41.2

6 7 Ø36@225(Alt.)
0 500 1000 1500 2000 2500 mm

R1245
0
4820

CONSTRUCTION JOINT
7500

2 2 Ø36@225(Alt.)

2 2 Ø36@225(Alt.)
4 3 Ø36@225(Alt.) MDCG-IFC-DIV-2011-R3 DIVERSION TUNNEL DT-1/DT-3 TUNNEL LINING LAYOUT PLAN & PROFILE
DIVERSION TUNNEL DT-3 OUTLINE OF CONCRETE LINING
MHP-02-SD-ULR-04-14-221~226
(CH0+063.58 TO CHO+451.00)
DIVERSION TUNNEL DT-3 CONCRETE LINING TYPE DT3-E1
MDCG-IFC-DIV-2018B-R0

p.)
) (FOR RS-I, RS-II & RS-III) CONCRETE OUTLINE & REINFORCEMENT

(Ty
11 11a 159+159 Ø13@150(Alt.) Dwg. No. DRAWING TITLE

05
3 4 Ø36@225(Alt.)

23
REFERENCE DRAWINGS
EMPLOYER:
2305(Typ.) 2305(T
)

yp.) PAKISTAN
700

WATER AND POWER DEVELOPMENT AUTHORITY


5 5 Ø36@225(Alt.)
CONSULTANT:
11 11a 34+34 Ø13@150(Alt.)
5118 5118
10236
CONTRACTOR:

CGGC-DESCON Joint Venture DESCON

MOHMAND HYDROPOWER PROJECT


DESIGNED Song Jian 2023.11.24
DIVERSION TUNNEL-3
CHECKED Peng Xiaochuan 2023.11.24
REINFORCEMENT OF CONCRETE LINING
EXAMINED Wu Jinxu 2023.11.24
CH0+368.90 TO CH0+451.00 (2/7)
VERIFIED Yang Hai 2023.11.24
APPROVED He Zhoushi 2023.11.24 SHOP DRAWING DESIGN CIVIL WORKS SECTION
SCALE SEE DRAWING DRAWING No. MHP-02-SD-ULR-04-15-370-D1
REV / IND DATE PREPARED CHECKED ENDORSED DESCRIPTION

SECTION C
ULR-04-15-373

CL DT-3

12 288 Ø13@150

8 9 Ø36@225(Alt.) 230
5(Ty

)
p.)
700

p.)

)
5(Ty 9 8 Ø36@225(Alt.)
230

2 2 Ø36@225(Alt.)
NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.
2. THE DRAWING IS APPLICABLE TO DIVERSION TUNNEL DT-3.
4. LINING TYPE DT3-E1 AND DT3-E2 DIFFER FROM EACH OTHER IN TERMS OF EXCAVATION
PROFILE AND INSTALLED ROCK SUPPORT.
5. LINING TYPE DT3-E1 SHALL BE INSTALLED IN REACHES WHERE ROCK SUPPORT
TYPE RS-I, RS-II, OR RS-III HAS BEEN PROVIDED.
7500

6. FOR LINING PLAN & PROFILE REFER TO DWG. NO. MHP-02-SD-ULR-04-13-011~012.


7. THE CONCRETE USED FOR CONSTRUCTION OF CONCRETE LINING SHALL BE
CLASS 'D' CONCRETE WITH MINIMUM COMPRESSIVE STRENGTH OF 25MPa AT 28 DAYS.

R8
8. THE CLEAR COVER TO REINFORCEMENT SHALL BE 100mm.

200
R7 9. ALL REINFORCEMENT SHALL BE STAGGER SPLICED UNLESS DIRECTED
50 OTHERWISE BY THE ENGINEER.
0
10. STEEL REINFORCEMENT SHALL BE DEFORMED HIGH YIELD STEEL BARS CONFORMING
2 1 Ø36@225(Alt.) 1 2 Ø36@225(Alt.) TO ASTM A615M, GRADE 60 [420] HAVING A MINIMUM YIELD POINT STRESS OF 420MPa.
11. CONCRETE PLACEMENT OF WALLS AND CROWN MUST BE COMPLETED WITHOUT
15000 PRESENCE OF COLD JOINTS.
12. THE SPACING OF CONSTRUCTION JOINTS IN LONGITUDINAL DIRECTION
700 3250 4250 7500 700 SHALL NOT EXCEED 12m.
7 6 Ø36@225(Alt.) 13. TRANSVERSE JOINTS BETWEEN ADJACENT LINING SECTIONS ARE STANDARD
16400

CONSTRUCTION JOINTS.
14. SCALE:
°
41.2

0 500 1000 1500 2000 2500 mm


6 7 Ø36@225(Alt.)

R1245
0
4820

CONSTRUCTION JOINT
7500

2 2 Ø36@225(Alt.)

2 2 Ø36@225(Alt.) MDCG-IFC-DIV-2011-R3 DIVERSION TUNNEL DT-1/DT-3 TUNNEL LINING LAYOUT PLAN & PROFILE
DIVERSION TUNNEL DT-3 OUTLINE OF CONCRETE LINING
4 3 Ø36@225(Alt.) MHP-02-SD-ULR-04-14-221~226
(CH0+063.58 TO CHO+451.00)
DIVERSION TUNNEL DT-3 CONCRETE LINING TYPE DT3-E1
MDCG-IFC-DIV-2018B-R0
(FOR RS-I, RS-II & RS-III) CONCRETE OUTLINE & REINFORCEMENT
Dwg. No.

p.)
) DRAWING TITLE

(Ty
12 318 Ø13@150 REFERENCE DRAWINGS
3 4 Ø36@225(Alt.) 05
23
EMPLOYER:
PAKISTAN
2305(Typ.) 2305(T
)

yp.)
WATER AND POWER DEVELOPMENT AUTHORITY
700

CONSULTANT:
5 5 Ø36@225(Alt.)
12 68 Ø13@150
5118 5118
10236 CONTRACTOR:

CGGC-DESCON Joint Venture DESCON

MOHMAND HYDROPOWER PROJECT


DESIGNED Song Jian 2023.11.24
DIVERSION TUNNEL-3
CHECKED Peng Xiaochuan 2023.11.24
REINFORCEMENT OF CONCRETE LINING
EXAMINED Wu Jinxu 2023.11.24
CH0+368.90 TO CH0+451.00 (3/7)
VERIFIED Yang Hai 2023.11.24
APPROVED He Zhoushi 2023.11.24 SHOP DRAWING DESIGN CIVIL WORKS SECTION
SCALE SEE DRAWING DRAWING No. MHP-02-SD-ULR-04-15-371-D1
REV / IND DATE PREPARED CHECKED ENDORSED DESCRIPTION

SECTION D
ULR-04-15-375

CL DT-3

8 9 Ø36@225(Alt.) 230
5(Ty

)
p.)

700
p.)

)
5(Ty 9 8 Ø36@225(Alt.)
230

2 2 Ø36@225(Alt.)

14
144
150

Ø1
3@

3@
15
Ø1

150
NOTES:

13
144


1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.

15
13

2. THE DRAWING IS APPLICABLE TO DIVERSION TUNNEL DT-3.

13
7500

4. LINING TYPE DT3-E1 AND DT3-E2 DIFFER FROM EACH OTHER IN TERMS OF EXCAVATION
PROFILE AND INSTALLED ROCK SUPPORT.

R8200
5. LINING TYPE DT3-E1 SHALL BE INSTALLED IN REACHES WHERE ROCK SUPPORT

14
TYPE RS-I, RS-II, OR RS-III HAS BEEN PROVIDED.

159 Ø
R7
6. FOR LINING PLAN & PROFILE REFER TO DWG. NO. MHP-02-SD-ULR-04-13-011~012.

50
7. THE CONCRETE USED FOR CONSTRUCTION OF CONCRETE LINING SHALL BE

13@
CLASS 'D' CONCRETE WITH MINIMUM COMPRESSIVE STRENGTH OF 25MPa AT 28 DAYS.

150
2 1 Ø36@225(Alt.) 8. THE CLEAR COVER TO REINFORCEMENT SHALL BE 100mm.
9. ALL REINFORCEMENT SHALL BE STAGGER SPLICED UNLESS DIRECTED
15000 OTHERWISE BY THE ENGINEER.
10. STEEL REINFORCEMENT SHALL BE DEFORMED HIGH YIELD STEEL BARS CONFORMING
700 3250 4250 7500 700 TO ASTM A615M, GRADE 60 [420] HAVING A MINIMUM YIELD POINT STRESS OF 420MPa.
7 6 Ø36@225(Alt.) 11. CONCRETE PLACEMENT OF WALLS AND CROWN MUST BE COMPLETED WITHOUT
16400

PRESENCE OF COLD JOINTS.


12. THE SPACING OF CONSTRUCTION JOINTS IN LONGITUDINAL DIRECTION
SHALL NOT EXCEED 12m.

°
41.2
6 7 Ø36@225(Alt.) 13. TRANSVERSE JOINTS BETWEEN ADJACENT LINING SECTIONS ARE STANDARD
CONSTRUCTION JOINTS.
1 2 Ø36@225(Alt.) 14. SCALE:
R124 0 500 1000 1500 2000 2500 mm
50
4820

CONSTRUCTION JOINT
7500

2 2 Ø36@225(Alt.)

2 2 Ø36@225(Alt.)
4 3 Ø36@225(Alt.)
MDCG-IFC-DIV-2011-R3 DIVERSION TUNNEL DT-1/DT-3 TUNNEL LINING LAYOUT PLAN & PROFILE
DIVERSION TUNNEL DT-3 OUTLINE OF CONCRETE LINING
MHP-02-SD-ULR-04-14-221~226
(CH0+063.58 TO CHO+451.00)

p.)
) DIVERSION TUNNEL DT-3 CONCRETE LINING TYPE DT3-E1

(Ty
MDCG-IFC-DIV-2018B-R0

05
3 4 Ø36@225(Alt.) (FOR RS-I, RS-II & RS-III) CONCRETE OUTLINE & REINFORCEMENT

23
Dwg. No. DRAWING TITLE
2305(T REFERENCE DRAWINGS
2305(Typ.)
)

yp.)
700

EMPLOYER:
PAKISTAN
5 5 Ø36@225(Alt.) WATER AND POWER DEVELOPMENT AUTHORITY
13 34 Ø13@150 14 34 Ø13@150 CONSULTANT:

5118 5118
10236

CONTRACTOR:

CGGC-DESCON Joint Venture DESCON

MOHMAND HYDROPOWER PROJECT


DESIGNED Song Jian 2023.11.24
DIVERSION TUNNEL-3
CHECKED Peng Xiaochuan 2023.11.24
REINFORCEMENT OF CONCRETE LINING
EXAMINED Wu Jinxu 2023.11.24
CH0+368.90 TO CH0+451.00 (4/7)
VERIFIED Yang Hai 2023.11.24
APPROVED He Zhoushi 2023.11.24 SHOP DRAWING DESIGN CIVIL WORKS SECTION
SCALE SEE DRAWING DRAWING No. MHP-02-SD-ULR-04-15-372-D1
REV / IND DATE PREPARED CHECKED ENDORSED DESCRIPTION
13 Ø
36@
2
PROFILE OF CONCRETE LINING FROM CH 0+415.77 TO CH 0+451.00 (INSIDE FACE)
2 25(A
14 Ø lt.)
36@
225(

ULR-04-15-369
Alt.)

A
ULR-04-15-370
B
1 1
4 Ø36
C.J @225
2 1 (Alt.)

0+433.77

0+451.00
3 Ø36
@225
(Alt.) 1 13 Ø
670 36@225
(Alt.)
(TY 5
P.)
230

700
2 14 Ø
(TYP C.J 36@225 1 14 Ø36@22
.) (Alt.) 5(A lt.)
1 13 Ø36@225(Alt.) 1 12 Ø36@225(Alt.) 1 14 Ø36@225(Alt.) 1 13 Ø36@225(Alt.)
2 2 13 Ø36@22
26 Ø 5(A lt.)
36@ C.J 2 14 Ø36@225(Alt.) 2 12 Ø36@225(Alt.) 2 13 Ø36@225(Alt.) 2 14 Ø36@225(Alt.)
225(

2305
.)
Alt.)

(TYP
670
)
(Alt.

C.J
0

(TYP.) C.J C.J C.J CJ


@15

2 2 670

2305
(TYP.)
7 Ø36
Ø13

@ 225(A
lt.) (TYP.)

7500
159

(TYP.)
2305

(TYP.)
2 27 Ø 670

(TYP.)

(TYP.)

(TYP.)
2305
6000

2305

2305

2305
36@2
0(Alt.) 25(Alt.) (TYP.) 670 1130 670
2 27 Ø36@22
3@15

5(A lt.)
2 27 Ø36@225(Alt.) 2 24 Ø36@225(Alt.) 2 27 Ø36@225(Alt.) 2 27 Ø36@225(Alt.)
6000
.)

5 9 Ø1
2305
(TYP

670

11a 159 Ø13@150(Alt.)


0(Alt.)
12 1

10 159 Ø13@150(Alt.)
(TYP
.) 6000 NOTES:

@15
6000 1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.

12 159 Ø13
5230 6000 6000
2. THE DRAWING IS APPLICABLE TO DIVERSION TUNNEL DT-3.
(TYP.)
2305

4. LINING TYPE DT3-E1 AND DT3-E2 DIFFER FROM EACH OTHER IN TERMS OF EXCAVATION
PROFILE AND INSTALLED ROCK SUPPORT.

(TYP.)
2305
2 1 5. LINING TYPE DT3-E1 SHALL BE INSTALLED IN REACHES WHERE ROCK SUPPORT
4 Ø36 670

(TYP.)

(TYP.)

(TYP.)
(TYP.)
@225 TYPE RS-I, RS-II, OR RS-III HAS BEEN PROVIDED.

2305

2305

2305

2305
1 1 (Alt.)

11
3 Ø36 (TYP.) 6. FOR LINING PLAN & PROFILE REFER TO DWG. NO. MHP-02-SD-ULR-04-13-011~012.
@225
(Alt.) 7. THE CONCRETE USED FOR CONSTRUCTION OF CONCRETE LINING SHALL BE

7500
670 670
2 13 Ø CLASS 'D' CONCRETE WITH MINIMUM COMPRESSIVE STRENGTH OF 25MPa AT 28 DAYS.
36@ 225(Alt.) (TYP.) 670 1130 670
(TYP.) 8. THE CLEAR COVER TO REINFORCEMENT SHALL BE 100mm.
1 14 Ø
36@ 225(Alt.) 9. ALL REINFORCEMENT SHALL BE STAGGER SPLICED UNLESS DIRECTED
2 14 Ø36@22 OTHERWISE BY THE ENGINEER.
5(Alt.)
1 13 Ø36@22 2 13 Ø36@225(Alt.) 2 12 Ø36@225(Alt.) 2 14 Ø36@225(Alt.) 2 13 Ø36@225(Alt.) 10. STEEL REINFORCEMENT SHALL BE DEFORMED HIGH YIELD STEEL BARS CONFORMING
5(Alt.)
.77

TO ASTM A615M, GRADE 60 [420] HAVING A MINIMUM YIELD POINT STRESS OF 420MPa.
1 14 Ø36@225(Alt.) 1 12 Ø36@225(Alt.) 1 13 Ø36@225(Alt.) 1 14 Ø36@225(Alt.)
0+415

11. CONCRETE PLACEMENT OF WALLS AND CROWN MUST BE COMPLETED WITHOUT


PRESENCE OF COLD JOINTS.
12. THE SPACING OF CONSTRUCTION JOINTS IN LONGITUDINAL DIRECTION

700
SHALL NOT EXCEED 12m.
13. TRANSVERSE JOINTS BETWEEN ADJACENT LINING SECTIONS ARE STANDARD

A
B
CONSTRUCTION JOINTS.
14. SCALE:

11 Ø 0 750 1500 2250 3000 3750 mm


36@
2 25(A
PROFILE OF CONCRETE LINING FROM CH 0+379.77 TO CH 0+415.77 (INSIDE FACE)
lt .)
1 1 lt.)
4 Ø3 25(A
C.J 6@2 6@2

ULR-04-15-371
2 1 25(A 3 Ø3

C
3 Ø3 lt.) 1 Alt.)
6@2 1 225(
25(A Ø 36@
lt.) 1 13 0+397.77 lt.) 2 1
4
700

Ø36@2 225(A
25(Alt.) Ø36@
C.J 2 14 1 14 lt.)
Ø36@ 225(A C.J
225(Alt 1 14 Ø36@
@225(Alt.
) Ø36@
670 .) 225(Al t.) 1 13 Ø36 2 13 670
22 Ø
36@
(TYP
.) 2 13 Ø36@ 1 13 Ø36@225(Alt.) 1 14 Ø36@225(Alt.) @225(Alt.
) .)
225 C.J 22 5(Alt.) 2 14 Ø36 (TYP
(TYP 5

(Alt. C.J
.)
230

)
670
2 14 Ø36@225(Alt.) 2 13 Ø36@225(Alt.)

.)
(TYP
2305
(TYP.) C.J C.J 670
2305
(TYP.)

2 2
7 Ø3 C.J C.J lt.)
7500

6@2 (TYP.) 25(A


25(A 6@2 MDCG-IFC-DIV-2011-R3 DIVERSION TUNNEL DT-1/DT-3 TUNNEL LINING LAYOUT PLAN & PROFILE
.)

670 3
lt.) 27 Ø
0(Alt

670

(TYP.)
DIVERSION TUNNEL DT-3 OUTLINE OF CONCRETE LINING

2305
(TYP.) 2 MHP-02-SD-ULR-04-14-221~226
@15

(TYP.) (CH0+063.58 TO CHO+451.00)


(TYP.)
2305

6000 2 27 DIVERSION TUNNEL DT-3 CONCRETE LINING TYPE DT3-E1

(TYP.)
(Alt.)

2305
Ø36@
Ø13

225 MDCG-IFC-DIV-2018B-R0
(TYP.)

225(Alt Ø36@
2305

(FOR RS-I, RS-II & RS-III) CONCRETE OUTLINE & REINFORCEMENT


(TYP.)
2305

.)
2 27
159

Dwg. No. DRAWING TITLE

50(Alt.)
6000 2 27 Ø36@
22 5(Alt.) @ 225(Alt.) 6000 REFERENCE DRAWINGS
2 26 Ø36
12

lt.)

13@1
150(A

EMPLOYER:
2 27 Ø36@225(Alt.) 2 27 Ø36@225(Alt.) PAKISTAN
.)
2305
(TYP

0(Alt.)

150(Alt.)


@

6000 WATER AND POWER DEVELOPMENT AUTHORITY


0 Ø13

12 159 Ø13@150(Alt.)

6000

.)
12 15
13@15

(TYP
2305
(TYP.)
2305

13@
12 8

6000 6000 CONSULTANT:


6000
12 159 Ø

670 12 159 Ø
670
(TYP

(TYP.)
2 1 .) 670 (TYP.)

2305

(TYP.)
2305

36@
1 1 2 25(A (TYP.) 670
(TYP.)

3Ø lt.)
2305
7500

(TYP.)

36@
2305

(TYP.)

225(A 2 CONTRACTOR:
(TYP.)
2305

lt.)
2 13
Ø36@2 lt.) CGGC-DESCON Joint Venture DESCON
25(Alt.) 670 225(A
1 14 Ø36@
Ø36@2 (TYP.) 2 14 (A lt.)
25(Alt.) 225
Ø36@
2 14 Ø36@
22
5(Alt.) @225(Alt.
) 1 13
2 13 Ø36 MOHMAND HYDROPOWER PROJECT
.77

1 13 Ø36@ 2 13 Ø36@225(Alt.) lt. )


2 14 Ø36@225(Alt.) A
0+379

225(Alt.) @22 5(
1 14 Ø36
1 14 Ø36@225(Alt.) 1 13 Ø36@225(Alt.)
DESIGNED Song Jian 2023.11.24
DIVERSION TUNNEL-3

7
700

0+415.7
CHECKED Peng Xiaochuan 2023.11.24
REINFORCEMENT OF CONCRETE LINING
EXAMINED Wu Jinxu 2023.11.24
CH0+368.90 TO CH0+451.00 (5/7)
VERIFIED Yang Hai 2023.11.24
C

APPROVED He Zhoushi 2023.11.24 SHOP DRAWING DESIGN CIVIL WORKS SECTION


SCALE SEE DRAWING DRAWING No. MHP-02-SD-ULR-04-15-373-D1
13 Ø REV / IND DATE PREPARED CHECKED ENDORSED DESCRIPTION
36@

P.)
225 PROFILE OF CONCRETE LINING FROM CH 0+415.77 TO CH 0+451.00 (OUTSIDE FACE)
(TY
(A lt.)
6
14 Ø

ULR-04-15-369
A
36@

ULR-04-15-370
B
225 7 1
(Alt. 3Ø 36@
) 2

(TYP 5
25(A

.)
230
lt.)

0+433.77

0+451.00
6 1 7 13
4 Ø3 Ø36
6@2 @225(A
13 Ø 25(A lt.)

700
lt.)

.)
2305
36@

(TYP
225 7 13 Ø36
27 Ø (Alt. @225(Alt.)
36@ ) 6 14 7 13 Ø36@225(Alt.)
225 Ø36 @225(A 7 12 Ø36@225(Alt.) 7 13 Ø36@225(Alt.) 7 13 Ø36@225(Alt.)

(TYP.)
2305
(Alt. lt.)
)
9 1

(TYP.)
6 14 Ø36

2305
3Ø C.J C.J C.J C.J

(TYP.)

(TYP.)

(TYP.)
36@ @22 5(Alt.)

2305

2305

2305
670
225( 6 14 Ø36@225(Alt.)
8 2 Alt.) 6 12 Ø36@225(Alt.) 6 14 Ø36@225(Alt.) 6 14 Ø36@225(Alt.)
7 Ø3 (TYP.)
6@2
25(A 670 670
lt.) 9 13
Ø36@ 9 13 Ø36@225(Alt.)
225(Alt (TYP.)

7500
.) (TYP.)
8 27
Ø36@ 9 13 Ø36
225(Alt @22
6000 .) 5(Alt.)

(Alt.)
9 13 Ø36@225(Alt.) 9 12 Ø36@225(Alt.) 9 14 Ø36@225(Alt.) 670 1130 670
8 27 Ø36
@150 @225(Alt.)
8 27 Ø36@225(Alt.)
8 24 Ø36@225(Alt.) 8 27 Ø36@225Alt.) 8 27 Ø36@225Alt.)
3

6000
70 Ø1

11a 170 Ø13@150(Alt.)


670

0(Alt.)
12 1

(TYP
.) 6000

@15

10 170 Ø13@150(Alt.)
9 1 NOTES:
4Ø 36@ 6000 1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.

12 170 Ø13
225( 5230 6000 6000
A
(TYP 5

2. THE DRAWING IS APPLICABLE TO DIVERSION TUNNEL DT-3.


.)

lt.)
230

4. LINING TYPE DT3-E1 AND DT3-E2 DIFFER FROM EACH OTHER IN TERMS OF EXCAVATION
PROFILE AND INSTALLED ROCK SUPPORT.
6 1 9 14 670
3 Ø3 Ø36 @225(A 670 670 5. LINING TYPE DT3-E1 SHALL BE INSTALLED IN REACHES WHERE ROCK SUPPORT
6@2 lt.)
25(A TYPE RS-I, RS-II, OR RS-III HAS BEEN PROVIDED.

11
7 1 lt.) (TYP.)
2305
(TYP.)

4 Ø3 (TYP.) (TYP.)
6@2 6. FOR LINING PLAN & PROFILE REFER TO DWG. NO. MHP-02-SD-ULR-04-13-011~012.
25(A 9 14 Ø36
@225( Alt.) 7. THE CONCRETE USED FOR CONSTRUCTION OF CONCRETE LINING SHALL BE

7500
lt.)
6 13 9 14 Ø36@225(Alt.) 670 1130 670 CLASS 'D' CONCRETE WITH MINIMUM COMPRESSIVE STRENGTH OF 25MPa AT 28 DAYS.
Ø36@ 9 12 Ø36@225(Alt.) 9 13 Ø36@225(Alt.)
(TYP.)
2305

225(Alt 8. THE CLEAR COVER TO REINFORCEMENT SHALL BE 100mm.


.)
7 14 9. ALL REINFORCEMENT SHALL BE STAGGER SPLICED UNLESS DIRECTED
Ø36@ 9 14 Ø36@225(Alt.)

(TYP.)
2305
225(Alt OTHERWISE BY THE ENGINEER.

(TYP.)

(TYP.)

(TYP.)
.) 6 13 Ø36

2305

2305

2305
@225(A lt.) 10. STEEL REINFORCEMENT SHALL BE DEFORMED HIGH YIELD STEEL BARS CONFORMING
7

6 13 Ø36@225(Alt.)
0+415.7

7 14 Ø36 TO ASTM A615M, GRADE 60 [420] HAVING A MINIMUM YIELD POINT STRESS OF 420MPa.
@22 5(Alt.) 6 12 Ø36@225(Alt.) 6 13 Ø36@225(Alt.) 6 13 Ø36@225(Alt.)
11. CONCRETE PLACEMENT OF WALLS AND CROWN MUST BE COMPLETED WITHOUT
7 14 Ø36@225(Alt.) PRESENCE OF COLD JOINTS.
7 12 Ø36@225(Alt.) 7 14 Ø36@225(Alt.) 7 14 Ø36@225(Alt.)
12. THE SPACING OF CONSTRUCTION JOINTS IN LONGITUDINAL DIRECTION

600
SHALL NOT EXCEED 12m.
13. TRANSVERSE JOINTS BETWEEN ADJACENT LINING SECTIONS ARE STANDARD

A
B
CONSTRUCTION JOINTS.
14. SCALE:
0 750 1500 2250 3000 3750 mm
PROFILE OF CONCRETE LINING FROM CH 0+379.77 TO CH 0+415.77 (OUTSIDE FACE)
11 Ø 7 1 7
36@ 3 Ø3
450 6 @22
(TY 5

(Alt.
P.)
230

5(Alt

ULR-04-15-371
)
5(Alt.)

C
.)
6@22

2305 .)
6 1 3 Ø3

(TYP
7 1
0+397.77
4Ø 36@ 7 13
225( Ø36@
11 Ø Alt.) 225 (Alt.) lt.)
2305
.)

36@ @225(A 5(Alt.)


(TYP

Ø36 6@22
450 7 13
700

7 13 Ø 4 Ø3

(TYP.)
(Alt. 670 6 1
36@2 670

2305
) 6 14 25(Alt.)
Ø3 225( Alt.)
(TYP 6@22
5(Alt.) 7 13 Ø36@225(Al 7 13 Ø36@ .)
(TYP.)

.)
2305

t.) 7 13 Ø36@225(Alt.) lt.) (TYP


9 1 @225(A

(TYP.)
3 Ø3 Ø36

2305
6 @22 670 6 14 Ø 6 14
(TYP.)

36@
2305

5(Alt 225(Alt.)

(TYP.)
8 2

2305
(TYP.)

7Ø .) 225(Alt.)
2305

6 14 Ø36@ .)
36@ (TYP.) 6 14 Ø36@225(Al 25(Alt
225(
Alt.)
t.) 6 14 Ø36@225(Alt.) 3Ø 36@2
9 13 9 1 5(Alt.) MDCG-IFC-DIV-2011-R3 DIVERSION TUNNEL DT-1/DT-3 TUNNEL LINING LAYOUT PLAN & PROFILE
Ø36@
225(A 670 670 7 Ø3 6@22 DIVERSION TUNNEL DT-3 OUTLINE OF CONCRETE LINING
lt.) 8 2
lt.)

8 27 .) MHP-02-SD-ULR-04-14-221~226
(TYP.) 225(Alt (CH0+063.58 TO CHO+451.00)
150(A

7500

6000
Ø36@
225(A 9 13 Ø (TYP.) 9 1 3 Ø36@ DIVERSION TUNNEL DT-3 CONCRETE LINING TYPE DT3-E1
lt.) 36@22 lt.) MDCG-IFC-DIV-2018B-R0
5(Alt.) @225(A (FOR RS-I, RS-II & RS-III) CONCRETE OUTLINE & REINFORCEMENT
13@

8 27 Ø 9 13 Ø36@225(Al 9 13 Ø36@225(Alt.) 8 27
Ø36 Dwg. No. DRAWING TITLE
36@ t.) 9 13 Ø36@225(Alt.)

50(Alt.)
70 Ø

225(Alt.) REFERENCE DRAWINGS


6000 8 27 Ø36@
225( Alt.) 6000
0(Alt.)

8 27 Ø36@225(Al
12 1

t.) 8 27 Ø36@225(Alt.) EMPLOYER:

13@1
PAKISTAN
3@15

150(Alt.)

150(Alt.)

70 Ø
6000 WATER AND POWER DEVELOPMENT AUTHORITY
12 170 Ø13@150(Alt.)
5 Ø1

14 Ø 6000

12 1
36@
13@

225(
12 8

12 170 Ø13@

Alt.) 6000 6000 CONSULTANT:


6000
12 170 Ø

670
670 lt.)
(TYP 36@ 225(A
13 Ø .) 9 14 (TYP.) 4Ø
3
6@2 Ø36@ 670 9 1
25(A 225(A 670
14 Ø lt.) lt.) (TYP.)
2305
.)

36@ 670 CONTRACTOR:


(TYP

(TYP.) lt.)
225(
Alt.) (TYP.) Ø36 @225(A
9 14 Ø 9 14 5(Alt.)

(TYP.)
36@ 225(Alt.) 6@22 CGGC-DESCON Joint Venture DESCON

2305
6 13 3Ø 3
6 1
7500

Ø36@ 225( Alt.) lt.)


225 9 14 Ø36@225(Al 9 14 Ø36@ 5(A
(TYP.)

6@22
2305

(Alt.) t.) 9 14 Ø36@225(Alt.)


7 14 4 Ø3
7 1
(TYP.)

Ø36@
2305

225(A 25(Alt.)
lt.) Ø36@2
(TYP.)

6 13 Ø MOHMAND HYDROPOWER PROJECT


2305

6 13
(TYP.)

36@ 225(Alt.)
2305
(TYP.)
.77

25(Alt.)
2305

Ø36@2
0+379

7 14 Ø 225(Alt.) 7 14
36@ 225(Alt.) 6 13 Ø36@225(Al
t.) 6 13 Ø36@ DESIGNED Song Jian 2023.11.24
6 13 Ø36@225(Alt.) DIVERSION TUNNEL-3

7
0+415.7
225(Alt.) CHECKED Peng Xiaochuan 2023.11.24
7 14 Ø36@225(Al
t.) 7 14 Ø36@ EXAMINED Wu Jinxu
REINFORCEMENT OF CONCRETE LINING
7 14 Ø36@225(Alt.) 2023.11.24
CH0+368.90 TO CH0+451.00 (6/7)
VERIFIED Yang Hai 2023.11.24
700

APPROVED He Zhoushi 2023.11.24 SHOP DRAWING DESIGN CIVIL WORKS SECTION


C

SCALE SEE DRAWING DRAWING No. MHP-02-SD-ULR-04-15-374-D1


REV / IND DATE PREPARED CHECKED ENDORSED DESCRIPTION

PROFILE OF CONCRETE LINING FROM CH 0+368.90 TO CH 0+379.77 (INSIDE FACE) PROFILE OF CONCRETE LINING FROM CH 0+368.90 TO CH 0+379.77 (OUTSIDE FACE)

ULR-04-15-372
D
ULR-04-15-372
D

0+368.90
0+368.90

700
(Alt.)
36@225
1 13 Ø @22 5(Alt.)
5(Alt.) (Alt.) 7 13 Ø36
1 11 Ø36@225(Alt.) 1 14 Ø36@22 36@225 7 13 Ø36@225(Alt.)
NOTES:

(TYP.)
2 14 Ø 7 11 Ø36@450(Alt.)

2305
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.
5(Alt.)
2 11 Ø36@225(Alt.) 2 13 Ø36@22 2. THE DRAWING IS APPLICABLE TO DIVERSION TUNNEL DT-3.

(TYP.)
5(Alt.)

2305
C.J @22

(TYP.)
6 14 Ø36

2305

(TYP.)
4. LINING TYPE DT3-E1 AND DT3-E2 DIFFER FROM EACH OTHER IN TERMS OF EXCAVATION

2305
670 6 11 Ø36@450(Alt.) 6 14 Ø36@225(Alt.) 670 PROFILE AND INSTALLED ROCK SUPPORT.
C.J C.J 5. LINING TYPE DT3-E1 SHALL BE INSTALLED IN REACHES WHERE ROCK SUPPORT
(TYP.) (TYP.)
TYPE RS-I, RS-II, OR RS-III HAS BEEN PROVIDED.
670 670
6. FOR LINING PLAN & PROFILE REFER TO DWG. NO. MHP-02-SD-ULR-04-13-011~012.
7. THE CONCRETE USED FOR CONSTRUCTION OF CONCRETE LINING SHALL BE

(TYP.)
5(Alt.)

2305
2340 2340 @22
9 13 Ø36 CLASS 'D' CONCRETE WITH MINIMUM COMPRESSIVE STRENGTH OF 25MPa AT 28 DAYS.

(TYP.)
(TYP.)

670

2305
2305

670 8. THE CLEAR COVER TO REINFORCEMENT SHALL BE 100mm.


9 11 Ø36@450(Alt.) 9 13 Ø36@225(Alt.) @22 5(Alt.)
(Alt.) (TYP.) 8 27 Ø36

0(Alt.)
9. ALL REINFORCEMENT SHALL BE STAGGER SPLICED UNLESS DIRECTED
(TYP.) 36@225
2 27 Ø 8 27 Ø36@225(Alt.)
lt.)

8 22 Ø36@225(Alt.) OTHERWISE BY THE ENGINEER.


5(Alt.)
0(A

2 27 Ø36@22

14 85 Ø13@15
2 22 Ø36@225(Alt.) 10. STEEL REINFORCEMENT SHALL BE DEFORMED HIGH YIELD STEEL BARS CONFORMING

0(Alt.)
14 79 Ø13@15

TO ASTM A615M, GRADE 60 [420] HAVING A MINIMUM YIELD POINT STRESS OF 420MPa.

lt.)
11. CONCRETE PLACEMENT OF WALLS AND CROWN MUST BE COMPLETED WITHOUT

12 170 Ø13@15
150(Alt.)

13@150(A
6000 PRESENCE OF COLD JOINTS.
12 159 Ø13@150(Alt.)
6000
4870 6000 12. THE SPACING OF CONSTRUCTION JOINTS IN LONGITUDINAL DIRECTION
4870 6000

13@
SHALL NOT EXCEED 12m.

12 85 Ø
13. TRANSVERSE JOINTS BETWEEN ADJACENT LINING SECTIONS ARE STANDARD

12 80 Ø
2340 CONSTRUCTION JOINTS.
2340

(TYP.)
670 14. SCALE:

2305
670
(TYP.)
(TYP.)

670
2305

0 750 1500 2250 3000 3750 mm


2305

(TYP.)
5(Alt.)
670 670 9 14 Ø36@22
670

lt.)
9 11 Ø36@450(Alt.) 9 14 Ø36@225(Alt.) (TYP.)
0(Alt.)

(TYP.)

0(A
(TYP.)
(Alt.)

13 85 Ø13@15
36@225
13 80 Ø13@15

(TYP.)
2 13 Ø

2305
(TYP.)
2305
(Alt.)

(TYP.)
36@225 5(Alt.)

2305
5(Alt.) @22
2 11 Ø36@225(Alt.) 2 14 Ø36@22 1 14 Ø 6 13 Ø36
1 13 Ø36@ 22 5(Alt.) 6 11 Ø36@450(Alt.) 6 13 Ø36@225(Alt.) @22 5(Alt.)
1 11 Ø36@225(Alt.) 7 14 Ø36
7 11 Ø36@450(Alt.) 7 14 Ø36@225(Alt.)

MATERIAL SCHEDULE
0+379.77

0+379.77
D
BAR TOTAL LENGTH UNIT WEIGHT TOTAL WEIGHT
D

REINFORCEMENT SIZE
REMARK
(m) (kg/m) (t)

Ø13 58857.050 2.235 131.546


DEFORMED GRADE
60 Ø36 47486.610 7.907 375.477

TOTAL 507.0221

REINFORCEMENT BENDING SCHEDULE ( FOR CH 0+368.90 ~ CH 0+451.00)


CUT CUT
TOTAL TOTAL
BENDING DIAGRAM LENGTH BENDING DIAGRAM LENGTH
BAR LENGTH BAR LENGTH MDCG-IFC-DIV-2011-R3 DIVERSION TUNNEL DT-1/DT-3 TUNNEL LINING LAYOUT PLAN & PROFILE
No. PER PIECE PCS. REMARK No. PER PIECE PCS. REMARK
SIZE SIZE DIVERSION TUNNEL DT-3 OUTLINE OF CONCRETE LINING
MHP-02-SD-ULR-04-14-221~226
(dimensions are out to out in mm) Li(i=1,2...)mm (CH0+063.58 TO CHO+451.00)
mm m (dimensions are out to out in mm) Li(i=1,2...)mm mm m
DIVERSION TUNNEL DT-3 CONCRETE LINING TYPE DT3-E1
MDCG-IFC-DIV-2018B-R0
11280 12000
11280 (FOR RS-I, RS-II & RS-III) CONCRETE OUTLINE & REINFORCEMENT
1 Ø36 11280 369 4162.32 8 Ø36 12000 369 4428.00 Dwg. No. DRAWING TITLE
81
76

00
00

REFERENCE DRAWINGS
12000 9000
Ø36 12000 1476 17712.00 9 Ø36 9000 369 3321.00 EMPLOYER:
2
PAKISTAN
76

81
00

00

0
23
1 11
5
10 Ø13 12000 12000 674 8088.00 WATER AND POWER DEVELOPMENT AUTHORITY
3 Ø36 5° 9530 369 3516.57
67

R
70

2760 CONSULTANT:
11 Ø13 8 ° 9000 337 3033.00 R=56900~3100
8660 17
60
42

4 Ø36 8660 369 3195.54


12

4740
35

R
0

3 50 °
12 126° 11a Ø13 26 9000 337 3033.00 R=56900~3100
10

5 Ø36 12000 369 4428.00 1 CONTRACTOR:


23
23

9690
10

9690
12 Ø13
9000
9000 4381 39429.00 R=56900~3100
CGGC-DESCON Joint Venture DESCON
00
123

81
R

6 Ø36 12000 369 4428.00


50

143°
L
76

4380
20

13 Ø13 L=11750~3650 7700 337 2594.90 R=56900~3100


50
R

23 MOHMAND HYDROPOWER PROJECT


810

7 Ø36 1 161° 6220 369 2295.18 L


0

14 Ø13 L=12000~3900 7950 337 2679.15 R=56900~3100


24

3740
80

DESIGNED Song Jian 2023.11.24


DIVERSION TUNNEL-3
CHECKED Peng Xiaochuan 2023.11.24
REINFORCEMENT OF CONCRETE LINING
EXAMINED Wu Jinxu 2023.11.24
CH0+368.90 TO CH0+451.00 (7/7)
VERIFIED Yang Hai 2023.11.24
APPROVED He Zhoushi 2023.11.24 SHOP DRAWING DESIGN CIVIL WORKS SECTION
SCALE SEE DRAWING DRAWING No. MHP-02-SD-ULR-04-15-375-D1