DPV Foundation HB50
DPV Foundation HB50
DPV Foundation HB50
H 500 NOMINAL H
BED
G G
759
F F
450 100
GND LEVEL
E E
100 FLOORS.
250
D D
295
100
335 DETAIL A
C DIMENSIONS ARE INDICATIVE ONLY. MATCH WITH PHYSICAL BED.
M.S PLATE C
FOR LEVEL/SHIM
400
PLACE ANCHOR BOLTS TO SUIT MOUNTING HOLES. GIVE ABOUT 100-200MM ALL ROUND.
CONCRETE BASE 1000MM IN FRONT AND BACK OF MACHINE CLEARANCE FROM WALL FOR DRIVE ASSEMBLY.
PHYSICAL ISOLATION FROM VIBRATION IN THE FORM OF SAND-MOAT AROUND
FOUNDATION REQUIRED IF OPERATING NEAR HEAVY MACHINERY.
GIVE SUITABLE PLACE AROUND FOR WORKING, CRANE ACCESS, LOADING AND
B UNLOADING, TOOLS, INVENTORY BASED SITE CONDITION.
200 200 B
12 11 10 9 8 7 6 5 4 3 2 1