Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

For Construction: Abbreviations Reference Drawings List (Standard Drawings) Legend Abbreviations Legend Legend 0

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

LEGEND LEGEND LEGEND ABBREVIATIONS ABBREVIATIONS REFERENCE DRAWINGS LIST (STANDARD DRAWINGS)
0
EARTH/GRADE AB ANCHOR BOLT OC ON CENTER D-000-5310-203 STANDARD DRAWING FOR OPEN DITCH
FENCE
AOC ACCIDENTAL OIL OD OUTSIDE DIAMETER D-000-5310-204 STANDARD DRAWING - TYPICAL DETAIL OF ROADS AND ASPHALT PAVING
HANDRAIL CONTAMINATED SEWER OPN`G OPENING
CONCRETE FILL D-000-5310-205 STANDARD DRAWING TYPICAL DETAIL OF FENCE & GATES
A APPROX APPROXIMATELY OPP OPPOSITE A
ANCHOR BOLT ARR ARRANGEMENT OWS CONTINUES OIL D-000-5310-206 STANDARD DRAWING TYPICAL DETAIL OF FENCE & GATES

PLASTER, SAND & CEMENT ALT ALTERNATE CONTAMINATED SEWER D-000-5310-207 STANDARD DRAWING FOR ANCHOR BOLT DETAILS
BCD BOLT CIRCLE DIAMETER PLTF PLATFORM D-000-5310-208 STANDARD DRAWING FOR ANCHOR BOLT DETAILS
PIPE OR SLEEVE BOB BOTTOM OF BASE PLATE PROJ PROJECTION
D-000-5310-209 STANDARD DRAWING DETAILS OF INSERT PLATE
ROCK BOC BOTTOM OF CONCRETE P PEDESTAL
BOS BOTTOM OF STEEL PB PLINTH BEAM D-000-5310-210 CONCRETE GENERAL NOTES AND CONCRETE SURFACE PROTECTION DETAILS
B BC BOLTED CONNECTION PL PLATE D-000-5310-212 STANDARD DRAWING TYPICAL DETAIL OF LIFTING HOOK FOR PRECAST MISCELLANEOUS ELEMENT B
STONE FILL CONSTRUCTION JOINT BOQ BILL OF QUANTITY PS PIPE SUPPORT D-000-5310-213 STANDARD DRAWING TYPICAL DETAIL OF PILE CAP FOR CFA PILES (PC-1A/5 TO PC-2B/10)
BOTT BOTTOM PTFE POLY TETRA FLURO ETHYLENE
D-000-5310-214 STANDARD DRAWING TYPICAL DETAIL OF PILE CAP FOR CFA PILES (PC-3A/5 TO PC-4B/8)
BF BOTH FACES PVC POLY VINLY CHLORIDE
LOOSE FILL OR BATTS D-000-5310-215 STANDARD DRAWING TYPICAL DETAIL OF PILE CAP FOR CFA PILES (PC-5A/6 TO PC-6B/12)
(INSULATION) BLDG BUILDING QTY QUANTITY
B/W BOTHWAYS RC REINFORCED CONCRETE D-000-5310-216 STANDARD DRAWING RE-BAR ARRANGEMENT DETAILS - 1 OF 2
BOARDS OR QUILTS CONSTRUCTION JOINT BOD BOTTOM OF DITCH RAD RADIUS D-000-5310-217 STANDARD DRAWING RE-BAR ARRANGEMENT DETAILS - 2 OF 2
C WITH WATER STOP C
(INSULATION) BOP BOTTOM OF PIPE/PLATE RB ROOF BEAM D-000-5310-219 STANDARD DRAWING - FIRE PROOFING
BS BRITISH STANDARD RCP REINFORCED CONCRETE PIPE
D-000-5310-220 STRUCTURAL STEEL GENERAL NOTES
SOLID, CORK OR MAGNESIA CHQ`D PL CHEQUERD PLATE REINF REINFORCEMENT
(INSULATION) CONC CONCRETE
0 RGL ROUGH GROUND LEVEL D-000-5310-221 STANDARD DRAWING FOR FIXED LADDER AND CAGE DETAILS
RC DIKE WALL
CONN CONNECTION RWP RAIN WATER PIPE D-000-5310-222 STANDARD DRAWING FOR FIXED LADDER AND CAGE DETAILS
0 CONT CONTINUOUS SCHD SCHEDULE
GRATING D-000-5310-223 STANDARD DRAWING FOR STAIR CASE STANDARD DRAWING
D COL COLUMN SECT SECTION D
0 EARTHEN BUND WALL CORR CORRUGATED STIFF STIFFENER
D-000-5310-225 STANDARD DRAWING FOR HAND RAIL
CL CENTER SH/SHT SHEET D-000-5310-226 STANDARD DRAWING FOR GRATING DETAILS
BITUMINOUS CONCRETE PAVING
SPAN DIRECTION CTR'D CENTERED SIM SIMILAR D-000-5310-227 STANDARD DRAWING FOR CIRCULAR PLATFORM
CB CATCH BASIN SL PIPE SLEEPER D-000-5310-228 STANDARD DRAWING FOR CIRCULAR PLATFORM
PAVING SLAB FOOTPATH C/C CENTER TO CENTER SSL STRUCTURAL SLAB LEVEL
1 DETAIL MARK D-000-5310-229 STANDARD DRAWING FOR CIRCULAR PLATFORM
(IF DRAWN IN SAME DRG) CDL CLOSED DRAIN LINE SPEC SPECIFICATION
E CDS CLOSED DRAIN SYSTEM SP SLIDING POINT D-000-5310-230 STANDARD DRAWING - WALKWAYS AND CROSS OVERS E
INTERLOCKING TILES
(VEHICLE ACCESS AREAS) DETAIL No. (1, 2, 3, .....) CJ CONSTRUCTION JOINT SQUARE D-000-5310-234 STANDARD DRAWING FOR STRUCTURAL STEEL CONNECTIONS
CS CIVIL SUPPORT SQM SQUARE METER D-000-5310-402 STANDARD DETAILS FOR CONCRETE PAVING
CUM CUBIC METER SSS SANITARY SEWER SYSTEM
INTERLOCKING TILES 1 DETAIL MARK CSP CARBON STEEL PIPE STD STANDARD
D-000-5310-405 STANDARD DETAILS FOR FUNNEL, CLEAN OUT AND VENT SYSTEM
(WALKWAY AREAS)
5310-001 (IF DRAWN IN DIFFERENT DRG) D-000-5310-406 STANDARD DETAILS FOR MANHOLE
DN DOWN STGD STAGGERED
REFERENCE DRG No. DET DETAIL SYMM SYMMETRICAL/SYMMETRY D-000-5310-407 STANDARD DETAILS FOR WEIR MANHOLE
F GRAVEL FILLED AREA F
DIA DIAMETER SY SANITARY SEWER D-000-5310-408 STANDARD DETAILS FOR SANITARY MANHOLE
DETAIL 4 DEFORMED HIGH YIELD 0 SWD STORM WATER DRAIN D-000-5310-409 STANDARD DETAILS FOR CATCH BASIN
HEEL TITLE AT DETAIL STRENGTH REBAR TCT TELECOM CABLE TRENCH
- (IF DRAWN IN SAME DRG) D-000-5310-410 STANDARD DETAILS FOR VALVE PIT
EARTH WORK EMBANKMENT DIM DIMENSION TDB TELECOM DUCT BANK
THK THICKNESS D-000-5310-411 STANDARD DETAILS FOR LEAK DETECTION PIT
TOE
DETAIL 0 DP DRAIN PIT
1 TITLE AT DETAIL DRG/DWG DRAWING TOG TOP OF GROUT D-000-5310-413 STANDARD DETAILS FOR UNDERGROUND PIPE TRENCH DETAILS
5310-001 TOGR TOP OF GRATING
HOLLOW CONCRETE BLOCK (IF DRAWN IN DIFFERENT DRG) DW DRINKING WATER D-000-5310-415 STANDARD DETAILS FOR ELEC. & INST. CABLE TRENCH
G G
D/S DOWN STREAM TOC TOP OF CONCRETE
D-000-5310-416 STANDARD DETAILS FOR ELEC. & INST. DUCT BANK
EL ELEVATION (HEIGHT) TOF TOP OF FINISH
D-000-5310-420 STANDARD DETAILS FOR C.F.A PILE
ELECTRICAL/ INSTRUMENT CABLE DUCT BANK A SECTION/ VIEW MARK ELEV ELEVATION (VIEW) TYP TYPICAL
- (IF DRAWN IN SAME DRG) EQ EQUAL TOS TOP OF STEEL
T&B TOP & BOTTOM
SECTION No. (A, B, C, .....)
EQUIP EQUIPMENT 0
ELECTRICAL CABLE TRENCH (CONCRETE) EXT EXTERIOR TB TIE BEAM
H (ECT) EXP EXPANSION TEMP TEMPORARY H
EJ EXPANSION JOINT UNO UNLESS NOTED OTHERWISE
ELECTRICAL CABLES TRENCH (BURIED) A SECTION/ VIEW MARK EB EARTHING BOSS U/G UNDERGROUND
(ECT) 5310-001 (IF DRAWN IN DIFFERENT DRG) EDB ELECTRICAL DUCT BANK U/S UNDERSIDE
EF EACH FACE VERT VERTICAL
INSTRUMENT CABLE TRENCH (CONCRETE) EGL EXISTING GROUND LEVEL 0 VP VALVE PIT
(ICT) SECTION A TITLE AT SECTION/ VIEW EP EARTH PIT WF WELDED FRAME
J - (IF DRAWN IN SAME DRG) WP WORKING POINT J
ECT ELECTRICAL CABLE TRENCH
INSTRUMENT CABLE TRENCH (BURIED) FDN FOUNDATION WWF WELDED WIRE FABRIC
(ICT) WL WATER LEVEL
FIN FINISH
SECTION A TITLE AT SECTION/ VIEW FFL FINISHED FLOOR LEVEL
TELECOM CABLES TRENCH DETAIL-001 (IF DRAWN IN DIFFERENT DRG) FL FLOOR LEVEL
(TCT) 0 F FOOTING
K FT FLOOR TRAP K
CHEQUERED PLATE
SANITARY SEWER LINE FGL FINISHED GRADE LEVEL
FB FLOOR BEAM
FD FLOOR DRAIN
HOLE / CUTOUT / OPENING FS FAR SIDE
PIPE SLEEPER
0 FW FIRE WATER
FP FIXED POINT
L GL GRADE LEVEL L
POCKET OR RECESS / SUMP
OILY WATER SYSTEM GRTG GRATING
GA GENERAL ARRANGEMENT

MANHOLE EL------
ELEVATION MKD / PLAN ELEV.
GALV
HPFG
GALVANIZED
HIGH POINT FINISHED GRADE
FOR CONSTRUCTION
HPP HIGH POINT PAVING
HSB HIGH STRENGTH BOLT
M NEUTRALISATION PIT HDPE HIGH DENSITY POLY ETHYLENE M
REVISION MARK HP HIGH POINT
D-000-5310-220 STRUCTURAL STEEL GENERAL NOTES
HR HANDRAIL D-000-5310-210 CONCRETE GENERAL NOTES AND CONCRETE SURFACE
CATCH BASIN/ PIT REVISION No. HOR HORIZONTAL PROTECTION DETAILS
ICT INSTRUMENT CABLE TRENCH DRAWING NO. TITLE
ID INSIDE DIAMETER REFERENCE DRAWINGS
MANHOLE WITH WEIR HOLD No. INT INTERIOR
N HOLD MARK N
IDB INSTRUMENT DUCT BANK
HOLD- 1 IJ ISOLATION JOINT
FOUNDATION LOCATION FOR LIGHTING POLE 0 ISSUED FOR CONSTRUCTION HIM ASC/SMR PK/SM SL/MKG 27/08/2014
PAL PAL - PLANT AREA LIGHTING IL INVERT LEVEL
A ISSUED FOR APPROVAL HIM ASC/SMR PK/SM SL/MKG 19/03/2014
SFL - SECURITY FENCE LIGHTING IP INSERT PLATE
ENGG. PROJ.
LPP LOW POINT PAVING REV DESCRIPTION DRAWN CK'D APPD. APPD. DATE
ALL RIGHT RESERVED THIS DOCUMENT IS THE PROPERTY OF OMAN REFINERIES AND PETROCHEMICALS COMPANY LLC
LG LENGTH / LONG AND CONTAINS INFORMATION WHICH IS PROPRIETARY, THIS INFORMATION IS TO BE HELD IN CONFIDENCE.
P ROAD AND CENTRE LINE LP LOW POINT NO DISCLOSURE OR OTHER USE OF THIS DOCUMENT IS TO BE MADE P
WITHOUT THE PRIOR WRITTEN CONSENT OF OMAN REFINERIES AND PETROCHEMICALS COMPANY LLC
LTP LIGHT POLE
MAX MAXIMUM Oman Refineries and Petrochemicals Company LLC
WATERPROOFING,FELT MIN MINIMUM
FLASHING, ETC.
MISC MISCELLANEOUS
M OR m METER
RESILIENT TILE MH MAN HOLE
Q MHW MAN HOLE WITH WEIR
SOHAR REFINERY IMPROVEMENT PROJECT Q
MKD MARKED TITLE :

mm MILLIMETER ABBREVIATIONS AND LEGEND FOR


MS MILD STEEL CIVIL AND STRUCTURAL STEEL WORK
D-000-5310-224

MSL MEAN SEA LEVEL


ND NON CONTAMINATED DRAIN
DATE: PREP'D: CK'D: APP'D:
NTS NOT TO SCALE
R 19/03/2014 HIM ASC/SMR PK/SM R
N NORTH UNIT NAME & UNIT NUMBER: JOB NUMBER: SCALE: SH'T NO:
NS NEAR SIDE COMMON-0000 120476/JI-2022 NTS 1 OF 1
No NUMBER PCWBS: DRAWING NUMBER: SIZE REV:
0000 D-000-5310-224 A1 0
SIZE
A1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24