Vishay BLH
Transducers
Precision Force and Weight
Measurement Transducers
FEATURES
• Capacity range: 500 to 100K lb (227 to 45K kg)
• Compact - rugged
• Operational: -30° to +175°F
• Low deflection
• Environmentally sealed
• FM and CSA approved
DESCRIPTION APPLICATIONS
T3 type load cells, developed by Vishay second bridge. The second bridge can be • Dynamometers
BLH, are designed for various types of used simultaneously with the first bridge for
weighing and force measurement. Con- dual output or be reserved as a backup in • Tensile testing
struction of the U3 and T3 load cell utilizes case of failure. • Tension and
all of the advantages of SR-4® strain gag- compression weighing
es. All cells are fabricated with high
strength ‘ring’ type elements to provide an
output signal of 3 mV/V at rated capacity.
Each cell is designed for minimum deflec-
tion and 150% safe overload without dam-
age. U3G1 and U3G2 universal load cells
are shipped with calibration data verifying
accuracy in both tension and compression
modes. U3G2 and T3P2 cells contain a
CONFIGURATION
DIMENSIONS
SPECIFICATIONS
Performance Temperature U3 T3
Capacity 500, 1K, 2K, 3K, 5K, 10K, 20K, Safe Range -30 to +175°F -30 to +175°F
30K, 50K, and 100K lb (227, Compensated Range +30 to +130°F +30 to +130°F
454, 907, 1.4K, 2.3K, 4.5K, 9.1K, Effect on Zero Balance 0.0015% 0.0015%
13.6K, 22.7K, and 45.4K kg) RO/°F RO/°F
Performance (cont) U3 T3 Effect on Rated Output 0.005% 0.0008%
Rated Output (RO) 3mV/V - 0.25% 3mV/V ± 0.1% load/°F load /°F
Non-Linearity - % RO 0.10 0.05 Adverse Load Ratings
Hysteresis - % RO 0.02%1-100K 0.02%1-50K Safe Overload - % RO 150 150
0.05% 500lb 0.05% 500lb Max Overload - % RO 300 300
Repeatability - % RO 0.02 0.02 APPROVALS
Creep - % RO (20 min.) 0.03 0.03 FM (Factory Mutual) 3611 (Class l, ll, III; Div.1,2;
Variance Ten. - Cmp 0.015mV/V max. NA Groups A-G)
Electrical CSA C22.2 (Class l, lI,III; Div.1,2;
Recommended Excitation 10Vac - dc 10Vac - dc Groups A-G)
Zero Balance - % RO 1.0 1.0
Input Resistance (Ohms) 350 ± 3.5 350 ± 3.5
Output Resistance (Ohms) 350 ± 3.5 350 ± 3.5
Number of Bridges single/double single/double
Min. Insulation Resistance-megohms (@ 50Vdc)
Bridge to Ground 5000 5000
Shield to Ground 2000 2000
Electrical Connection 35 foot cable 35 foot cable
Vishay BLH is continually seeking to improve product quality and performance. Specifications may change accordingly.