MP3A
MP3A
MP3A
13. Any suitable opening Air test for a plumbing drainage and vent
system shall be made by attaching the air
compressor or other test apparatus to
20. Height of building Vertical distance from the "grade line" to the
highest point of the coping of a flat roof or
to the top line of a mansard roof or to the
average height of the highest gable of a pitch
or hip-roof
22. Dearerator
2 / 29
Master Plumber Reviewer
Study online at https://quizlet.com/_eavrci
To receive the discharge from aeration, what
is installed at the bottom portion of the soil
stack where the house drain is connected?
24. equal to the required Inlet and outlet pipe fittings or baffles, and
cross-sectional area compartment partitions shall have a free vent
area ______ of the house sewer or private
sewer discharging therein to provide free
ventilation above the water surface from the
disposal field or seepage pit through the sep-
tic tank, house sewer, and stack to the outer
air.
26. Welded joint & Seam Any joint or seam obtained by the joining of
metal parts in a plastic molten state.
28. Regulating Equipment include all valves and controls used in plumb-
ing systems which are required to be acces-
sible.
30. President of the Philippines Who shall appoint the Board of Examiners for
Master Plumber?
31. considered equivalent to When provided with water outlets for such
one lavatory space, a 610 mm width of was sink or 457
mm diameter of a circular basin, shall be
3 / 29
Master Plumber Reviewer
Study online at https://quizlet.com/_eavrci
32. Normal Pressure pressure range measured over a period of 24
hours
38. for each 150 persons there- Where food is consumed indoors, water sta-
after tions may be substituted for drinking foun-
tains. Offices, or public buildings for use by
more than six persons shall have one drink-
ing fountain for the first 75 persons and one
additional fountain_____
4 / 29
Master Plumber Reviewer
Study online at https://quizlet.com/_eavrci
43. Insanitary a condition contrary to sanitary principles OR
INJURIOUS TO HEALTH.
44. Combination Waste and Vent A specially designed system of waste piping
system embodying the horizontal wet venting of one
or more sinks or floor drains by means of
a common waste and vent pipe adequately
sized to provide free movement of air above
the flow line of the drain.
46. Citizen and resident of the Section 6 of RA 1378 states that each mem-
Philippines, at least 30 years ber of the Board shall, at the time of this
of age and of good moral appointment be:
character, has been actively
engaged in the trade of mas-
ter plumber for at least five
years
49. Secondary Branch Any branch in a building drain other than the
primary branch
51. 3 inches Minimum size of the drain pipe for the water
closet to discharge into?
5 / 29
Master Plumber Reviewer
Study online at https://quizlet.com/_eavrci
55. Commissioner of Civil Ser- Under Section 9 of RA 1378 who shall be the
vice executive officer of the Board, and shall con-
duct the examination given by the board and
shall designate any subordinate officer of the
Bureau of Civil Service to act as secretary of
the Board
57. not less than 14.4 kPa Each such tank shall be structurally designed
to withstand all anticipated earth or other
loads. All septic tank covers shall be capable
of supporting an earth load of _____ when
the maximum coverage does not exceed 9m.
58. Hubless It is a cast iron soil pipe with plain ends con-
nected together with bolted stainless steel
bands and neoprene gaskets
59. full way gate valve A valve used for controlling two or more out-
lets in a cold water supply line
64. Faucets and Diverters ______ shall be connected to the hot and
cold water distribution supplies so that the
hot water supply is located at left side of the
combination fittings.
65. No. 12 U.S. gauge The minimum wall thickness of any steel sep-
tic tank shall be ____
66. Mobile Home Park Sewer That part of the horizontal piping of sani-
tary drainage system which measures 0.6
m downstream from the last mobile home
site and conveys sewage to a public sew-
er, private sewer, individual sewage disposal
system and other points of disposal
67. Aluminum What is the material not listed in the code for
use in water piping?
8 / 29
Master Plumber Reviewer
Study online at https://quizlet.com/_eavrci
82. Corporation Stop Type of valve found in the service main, used
as a control of the water service and shut off
valve when service is disconnected.
84. Cast Iron Bell and Spigot A joint made by firmly packing with oakum
Soil Pipe and filled with molten lead to a depth of not
less than one inch.
86. Public or Private sewer Every building in which plumbing fixtures are
installed shall have connection to a _______
89. An air gap Assume you are installing a waste pipe for a
culinary sink. The pipe is a 1-1/2 inch copper
pipe. The code requires that the sink be pro-
tected from backflow. In order to pass inspec-
tion, you must provide ______
90. Open Floor Sink The drain pipe from a refrigerator must drain
into an ___
96. Hot Water Recirculating What do you call to this device that is being
Pump used to circulate hot water to the plumbing
system?
99. Distribution Box Where two or more drain lines are installed,
an approved ______ of sufficient size to re-
ceive lateral lines shall be install at the head
of each disposal field
103. 1/4 inch per foot Slope of a waste pipe with a minimum size of
3" horizontal pipe?
105. It has been approved The drainage system or any part thereof shall
not be covered until
106. Approved air-gap fitting The waste pipe from a domestic dishwashing
machine connected to a food-waste disposer
unit mush have a/an
110. the circulation pump shall All whirlpool bathtubs shall comply with the
be located above the crown following requirements, except
weir of the trap
11 / 29
Master Plumber Reviewer
Study online at https://quizlet.com/_eavrci
112. 101.6mm The inlet and outlet pipe or baffle shall extend
____ above and at least 304.8 mm below the
water surface.
114. Less than 76mm diameter The size of a trap arm may change direction
without the use of a cleanout when such di-
rection does not exceed 90º
115. 1 per 150 What is the urinal per male ratio for principal
worship places?
122. Ferrule
12 / 29
Master Plumber Reviewer
Study online at https://quizlet.com/_eavrci
a metallic sleeve caulked or joined to an
opening in a pipe into which a plug is
screwed that can be removed for cleaning or
examining the interior of the pipe
124. Storm Sewer Drainage Pip- A piping system designed to control and con-
ing vey excess ground water to a suitable loca-
tion
129. The inlet connection of the The size of supply piping outlet for any gas
appliance appliance shall not be less than _____
130. Prevent sewer gases from A trap is a fitting or a device designed to:
entering the building
131. Crow Weir to the top of the The trap seal is being measured from the
dip of a trap _____
13 / 29
Master Plumber Reviewer
Study online at https://quizlet.com/_eavrci
134. May issue a Partial Permit The Administrative Authority _____ for the
construction of a part of a large and/or com-
plicated plumbing system before the entire
plans and specifications for the whole system
have been submitted or approved, provid-
ed adequate information and detailed state-
ments have been filed, complying with all
pertinent requirements of this Code.
136. The discharge side of the Inlets to Tanks, Vats, Sumps, Swimming
last valve with the critical Pools and other receptors when protected by
level of not less than 152mm a listed atmospheric vacuum breaker shall
have such atmospheric vacuum breaker in-
stalled in
144. Vent pipe A pipe or opening used for ensuring the cir-
culation of air in a plumbing system and for
relieving the negative pressure exerted on
trap seals
151. Foot Valve A valve located at the lower end of the pump
and used mainly to prevent loss of priming of
the pump
153. Full Gate Valve The valve for controlling two or more outlets
in a cold water supply line.
155. Molded Rubber Coupling What is the approved method to use to make
Joints a bell-and-spigot joint between cast-iron pipe
and vitrified clay pipe?
156. Allowing for movement of Horizontal swing joints or pipe loops on long
pipe due to temperature runs of hot water piping are generally in-
changes stalled for the purpose of ______
157. 2 and 4 inches Except when deeper seals are required for
interceptors, a fixture trap must have a water
seal of between:
158. A trap with interior partitions Which of the following is a prohibited trap?
16 / 29
Master Plumber Reviewer
Study online at https://quizlet.com/_eavrci
161. Discharge capacity of fixture Fixture unit equivalents not commonly listed
in fixture unit tables must be based on _____
163. above the flood level of the When listed air-gap fittings are required for
sink or above the sink drain- sinks receiving the wastes from dish-washing
board, whichever is higher machines, where shall the plumber install the
flood level marking?
166. equivalent to half of the orig- What amount of a free shall be paid for the
inal free renewal of a plumbing permit?
167. Issued in error, on the ba- The Administrative Authority may, in writing,
sis of incorrect information suspend or revoke a permit issued under the
supplied, in violation of per- provisions of this Code whenever
tinent ordinances, rules and
regulations
168. Listed construction and ma- Heat exchangers, and other assemblies or
terials method of constructions using potable water
shall be of
169. A minimum of two separate Potable water shall be separated from the
walls, with a positive, vented fluids or gasses by
leak detection path
171. 101.9 li/m^2 - sandy loam - What is the maximum absorption capacity of
sandy clay a leaching area for a 24-hour period if the soil
has a sandy clay characteristic?
18 / 29
Master Plumber Reviewer
Study online at https://quizlet.com/_eavrci
179. Service pipe It is a pipe from the street water main to the
building served
187. Exposed Fixture Supply In the water supply piping slip joints may be
used only on the _____.
188. DPWH, DILG or City Mayor's Permit required under this jurisdiction
Office
19 / 29
Master Plumber Reviewer
Study online at https://quizlet.com/_eavrci
The inlet compartment of any septic tank
shall be ___ of the total capacity of the tank,
nor less than 2.0 m^3 liquid capacity.
197. Plumbing System all water, supply, drainage and venting sys-
tems with all their fixtures and traps.
207. Not be used under any cir- A trap depending on movable parts to retains
cumstances its seal may
208. Stall shower traps Cleanouts on the seal of a trap are prohibited
on
21 / 29
Master Plumber Reviewer
Study online at https://quizlet.com/_eavrci
stack, with or without lateral or vertical exten-
sions, on two or more floors.
212. Gauge No. 24 B & S or 0.5 What is the minimum thickness of copper
mm THK pans or liners?
218. Ball cock a valve opened and closed by the fall and
rise, respectively, of an attached ball
floating on a surface of the liquid
228. lowest to the highest point Building sewer shall be tested by completely
filling the sewer with water from the _____.
238. Pressure Relief Valve A water system that has water heater would
require a ____.
24 / 29
Master Plumber Reviewer
Study online at https://quizlet.com/_eavrci
241. 3 inches Minimum allowable size of any drain, hor-
izontal branch, vertical soil or waste stack
serving one or more water closets.
244. Bed-pan washer The term "liquid waste", is waste that is dis-
charged into the plumbing system from all but
one of the following fixtures.
250.
25 / 29
Master Plumber Reviewer
Study online at https://quizlet.com/_eavrci
Approves stainless steel For jointing of hub less cast-iron soil pipes
bands with neoprene gas- are acceptable to use
kets
251. All valves, pipes and fittings Prohibited fitting and practices, except
shall be installed in correct
relationship to the direction
of flow
252. 19.56 kg/m^3 and 1.6 mm weight and thickness of sheet lead shall not
thick be less than ____ for safe pans.
253. 14.63 kg/m^3 and 1.2 mm Weight and thickness of sheet lead shall not
thick be less than _____ for flashings or vent ter-
minals.
254. 56.8 li/day What is the estimated sewage flow rate for
day camp per person?
256. 18 .9 li/day what is the estimated flow rate for airports per
passenger?
260. Scupper
26 / 29
Master Plumber Reviewer
Study online at https://quizlet.com/_eavrci
It is a box like collection device which is locat-
ed on the exterior of the building and receives
storm water on one side.
261. Fire Hose Always located near the stairs for use by
firemen in case of fire.
262. Neoprene Rubber Sleeves The hubless is used in lieu of the pipe when
caulking and jointing of the pipe is quite dif-
ficult. The hubless pipe (cast iron_ is easily
joined by use of _____.
265. Cast-iron soil pipe Vertical _____ must be supported at the base
and at each story level at interval not exceed-
ing 15 feet.
268. Male threads only When joining threaded piping and fittings to-
gether, an approved joints compound must
be applied to ____ .
269. run parallel and dose to the Plumbing fixture shall be installed in a man-
nearest wall or building line. ner to provide easy access for repair and
cleaning. Where practical, all pipes from fix-
tures shall be
27 / 29
Master Plumber Reviewer
Study online at https://quizlet.com/_eavrci
272. DANGER- UNSAFE WATER Each outlet on the non-potable water line,
which
may be used for drinking or domestic purpos-
es, shall be posted: ____.
273. Yoke Vent The pipe connection upward for the soil or
waste stack to a vent stack for the purpose
of preventing pressure changes in the vent
stack is
274. Asbestos Cement Pipe Joints between ____ and other approved
pipe shall be made by means of an approved
adapter coupling.
28 / 29
Master Plumber Reviewer
Study online at https://quizlet.com/_eavrci
278. 1. Any public nuisance Nuisance means:
known in common law or in
equity jurisprudence.
2. Whenever any work regu-
lated by this Code is danger-
ous to human life or detri-
mental to health and proper-
ty
3. Inadequate or unsafe wa-
ter supply and or sewage
disposal system.
283. 3-1/2 inches Minimum pipe size of the vent pipe serving a
combination waste and vent system with a 4"
drain pipe
29 / 29